• Title/Summary/Keyword: Digital artery

Search Result 147, Processing Time 0.037 seconds

Use of Human Placentas for Practice of Microvascular Surgery (미세수술 술기 습득을 위한 태반의 사용)

  • Kang, Min-Gu;Yoon, Sang-Yup;Chang, Hak
    • Archives of Reconstructive Microsurgery
    • /
    • v.16 no.2
    • /
    • pp.53-56
    • /
    • 2007
  • Purpose: Microsurgical exercise has been performed with rat femoral vessels. But, it needs animal laboratory, anesthesia and its keeping facilities. Materials and Methods: Ten human placentas were studied for suitability in a microvascular exercise. The size and useful length of vessels were measured, and various microvascular anastomoses were performed. Result: The human placenta has many vessels traversing its fetal surface. A variety of sizes are available down to vessels of diameter 1 mm and up to vessels of diameter 6.5 mm (1.0

  • PDF

A Study on Pulse Wave Measurement System Based on USB Driver Transmission System (USB Driver 전송시스템 기반의 맥파 측정 시스템에 관한 연구)

  • Kim, E.G.;Park, M.K.;Han, S.S.;Huh, Y.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1914-1915
    • /
    • 2007
  • The period and strength of the pulse on the radial artery are important physiological factors, and they have been used to diagnosis in both Western and Eastern countries for a long time and has been developed as a unique method of diagnosis at each countries. Recently, there are a lot of systems which can give diagnosis information by recording the pulse wave and analyzing the characteristics of the pulse shape. This study describes the Pulse-Wave Measurement System which is able to measure the pulse wave signal using piezoresistive sensor and the pulse wave signal measured by the developed system is transmitted to a computer on the basis of the USB Driver. It has finally shown the the pulse wave signal measured by the sender is appeared to the host PC in real time. The Pulse-Wave Measurement System used the piezoresistive sensor to measure the pulse wave signal and the differential amplifier(AD620) to amplify the pulse wave signal which is small signal. And it used the ADC to convert analog to digital for the measured analog signal and the interface with a computer. It transmitted the measured pulse signal through USB transmission module to the host computer and Labview tool shows it. This Pulse-Wave measurement system will afford comvenience of detecting pulse wave to user related to oriental medicine.

  • PDF

Simultaneous Estimation of Spatial Frequency and Phase Based on an Improved Component Cross-Correlation Algorithm for Structured Illumination Microscopy

  • Zhang, Yinxin;Deng, Jiajun;Liu, Guoxuan;Fei, Jianyang;Yang, Huaidong
    • Current Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.317-325
    • /
    • 2020
  • Accurate estimation of spatial frequencies and phases for illumination patterns are essential to reconstructing super-resolution images in structured illumination microscopy (SIM). In this manuscript, we propose the improved component cross-correlation (ICC) algorithm, which is based on optimization of the cross-correlation values of the overlapping information between various spectral components. Compared to other algorithms for spatial-frequency and phase determination, the results calculated by the ICC algorithm are more accurate when the modulation depths of the illumination patterns are low. Moreover, the ICC algorithm is able to calculate the spatial frequencies and phases simultaneously. Simulation results indicate that even if the modulation depth is lower than 0.1, the ICC algorithm still estimates the parameters precisely; the images reconstructed by the ICC algorithm are much clearer than those reconstructed by other algorithms. In experiments, our home-built SIM system was used to image bovine pulmonary artery endothelial (BPAE) cells. Drawing support from the ICC algorithm, super-resolution images were reconstructed without artifacts.

Study on the interrelationship between the PWV and the temperature difference (맥파전달속도(PWV)와 말초체열분포(DITI)와의 관계 연구)

  • Lee, Yoon-Jae;Cho, Jung-Hoon;Lee, Chang-Hoon;Lee, Jin-Moo;Jang, Jun-Bock;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.6 no.1
    • /
    • pp.23-31
    • /
    • 2008
  • Objective: The purpose of this study is to identify relationship between the PWV and the temperature difference. Methods: When it comes to senile patients who suffer from cold limbs, there is need to see whether or not the patient's low temperature of the limbs is do to arteriosclerosis. The Pulse Wave Velocity(PWV) is a non-invasive method measuring the artery's rigidness. And the Digital Infrared Thermal Imaging(D.I.T.I) is a non-invasive method to see the body's thermal change. Research on the interrelationship of the artery's rigidness and body's thermal distribution was done by using these two tests. The subjects of this research were patients between the age 40~65 who have done both the D.I.T.I and PWV in March 2005~ September 2005. They had to have no history of diabetes, coronary illnesses or cerebrovascular diseases which are diseases that can effect the outcome of the PVW, nor history of spondylopathy or dermatosis which can effect the outcome of the D.I.T.I. Results: The results were as follows. 1. There was a significant interrelationship between the right wrist-ankle PWV and the temperature difference of the right wrist-palm. 2. There was a significant interrelationship between the left wrist-ankle PWV and the temperature difference of the left wrist-palm. 3. There was no significant interrelationship between the right wrist-ankle PWV and the temperature difference of the right thigh-dorsum of foot. 4. There was no significant interrelationship between the left wrist-ankle PWV and the temperature difference of the left thigh-dorsum of foot. 5. The right ABI showed no significant interrelationship between the temperature difference of the right wrist-palm and the right thigh-dorsum of foot. 6. The left ABI showed no significant interrelationship between the temperature difference of the left wrist-palm and the left thigh-dorsum of foot. Conclusion: The study shows that there was a significant interrelationship between wrist-ankle PWV and the temperature difference of wrist-palm.

  • PDF

Reconstruction of Electrical Burned Hand by Posterior Tibial Arterial Free Flap (후경골 동맥 유리 피판에 의한 수부 전기 화상의 재건)

  • Choi, Soo-Joong;Seo, Eun Min;Lee, Chang Ju;Chang, Jun Dong;Kim, Suk Wu;Lee, Sang Hun;Lee, Dong Hun;Seo, Young jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.14-23
    • /
    • 2004
  • Introduction: The hand and wrist are particularly susceptible to electrical burn. Skin defect with damage or exposure of underlying vital structure requires coverage by skin flap especially in case of the need for late reconstruction. We are reporting 4 cases of electrical burned hand treated by posterior tibial arterial free flap. The commonly used skin flaps such as scapular flap or groin flap are too bulky so that they are not satisfactory in function and cosmetic appearance. So we tried to cover them with a more thin skin flap. Materials and Method: From January 2002 to June 2003, four cases of hand and wrist electrical burn were covered using posterior tibial arterial free flap. All the cases were due to high voltage electrical burn. Age ranged from 31 years to 38 years old and all the cases were male patients. Recipient sites were 2 wrist, one thenar area and one knuckle of 2.3rd MP joint. Additional procedures were flexor tenolysis (simultaneous), FPL tenolysis and digital nerve graft (later) and extensor tendon reconstruction (later). Result: All the flap have survived totally without any complication including circulatory concern about the donar foot. Posterior tibail arterial free flap was so thin that debulking procedure was not required. Conclusion: For skin coverage of the hand & wrist region, posterior tibial arterial free flap have many advantages such as reliable anatomy, easy dissection and easy anastmosis with radial or ulnar artery and possibility of sensory flap. The most helpful advantage for hand coverage is its thinness. So we think this flap is one of the very useful armamentarium for reconstructive hand surgery.

  • PDF

Long-Term Outcomes of Stenting on Non-Acute Phase Extracranial Supra-Aortic Dissections

  • Jiang, Yeqing;Di, Ruoyu;Lu, Gang;Huang, Lei;Wan, Hailin;Ge, Liang;Zhang, Xiaolong
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.3
    • /
    • pp.422-429
    • /
    • 2022
  • Objective : Extracranial supra-aortic dissections (ESADs) with severe stenosis, occlusion and/or pseudoaneurysm presents potential risk of stroke. Endovascular stenting to reconstruct non acute phase ESADs (NAP-ESADs) is an alternative to anticoagulant or antiplatelet therapy. However, its feasibility, safety and efficacy of stenting in NAP-ESADs is unclear. This study aims to investigate the long-term outcomes of the feasibility, safety and efficacy of stenting in NAP-ESADs. Methods : Seventy-four patients with 91 NAP-ESAD vessels with severe stenosis, occlusion and/or pseudoaneurysm presents potential risk of stroke who underwent stent remodeling were enrolled into this respective study from December 2008 to March 2020. Technical success rate, complications, clinical and angiographic results were harvested and analyzed. Results : Success rate of stent deployment was 99% (90/91) with no procedural mortality or morbidity. Transient ischemic attack occurred in three patients during operation (4.1%, 3/74). Asymptomatic embolisms of distal intracranial vessels were found in two patients (2.7%, 2/74). One hundred and forty-two stents deployed at 85 carotid (135 stents) and six vertebral (seven stents) vessels. Six stent types (Wingspan, 28/135, 20.7%; Solitaire, 10/135, 7.4%; Neuroform, 8/135, 5.9%; LVIS, 2/135, 1.5%; Precise, 75/135, 55.6%; Acculink, 12/135, 8.9%) were deployed at carotid arterial dissection while two types (Wingspan, 5/7, 71.4%; Solitaire 2/7, 28.6%) at vertebral arterial dissection. Digital subtracted angiography (56%, 51/91), computational tomography angiography (41.8%, 38/91) and high resolution magnetic resonance imaging (2.2%, 2/91) were adopted for follow up, with a mean time of 17.2±15.4 months (5-77). All patient modified Rankin Scale scores showed no increase at discharge or follow-up. Angiographically, dissections in 86 vessels in 69 patients (94.5%, 86/91) were completely reconstructed with only minor remnant dissections in four vessels in four patients (4.4%, 4/91). Severe re-stenosis in the stented segment required re-stenting in one patient (1.1%, 1/91). Conclusion : Stent remodeling technique provides feasible, safe and efficacious treatment of ESADs patients with severe stenosis, occlusion and/or pseudoaneurysm.

The First Web Space Free Flap of the Foot to Reconstruct the Pulp of Fingers (수지 수질부 재건을 위한 족부의 제 1물갈퀴부 유리 피판술)

  • Kong, Byeong Seon;Kim, Yun Seok;Lee, Hyeong Seok;Jung, Dae Won;Kwak, Jae Yong;Lee, Hyun Suk
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.2
    • /
    • pp.153-158
    • /
    • 2012
  • Purpose: The first web space of the foot has a similar thickness and skin texture of the pulp of the fingers. Moreover, it has a reliable blood vessel and sensory nerve. The purpose of this study was to evaluate the clinical results of the first web space free flap to reconstruct the pulp of fingers. Materials and Methods: Authors have performed 23 cases of first web space free flap to reconstruct the pulp defect of the fingers between June 2004 and May 2009. The age of the patients ranged from 20 years old to 55 years old. The size of the flap ranged from $1{\times}1.5cm$ to $8.5{\times}2.5cm$. The mean flap area was 5.4 cm2. In 4 cases, we elevated the flap including lateral aspect of the big toe and medial aspect of the second toe. And then we made an artificial syndactyly to reconstruct the pulps on two fingers at the same time. In all cases, we performed 1 digital artery and 1 dorsal vein anastomosis. Every donor site that had a small defect healed spontaneously without any additional operations to cover it. Results: Of this type of surgery 21 flaps (91.3%) survived, 2 flaps (8.7%) failed. There was no severe complication in the donor sites. There was no walking disturbance due to the skin defect of the donor site. The static 2 point discrimination in 11 cases that we could check ranged from 3 mm to 15 mm. Conclusion: The authors believe that the first web space free flap of the foot is a good option for the reconstruction of the pulp of the fingers and it has a minimal donor site morbidity.

  • PDF

A Systemic Review of Pulse Contour Analysis and Fourier Spectrum Analysis on the Photoplethysmography of Digit (지첨용적맥파의 파형분석과 주파수분석에 대한 문헌적 연구)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.1
    • /
    • pp.48-60
    • /
    • 2007
  • Palpation of the pulse has been used in Korean traditional medicine since ancient times to assess physical health. Pulse wave contour may be obtained by measuring arterial pressure or blood volume change of skin. The latter is called as Photoplethysmography(PPG) or digital volume pulse(DVP). The PPG signal is measured by a device comprising an infrared light sourece and a photodetector. Although less widely used, this technique deserves further consideration because of its simplicity and ease of use. The contour of the PPG is formed as a result of a complex interaction between the left ventricle and the systemic circulation. It usually exhibits an early systolic peak and an early diastolic peak. the first peak is formed mainly by pressure trasmitted along a direct path from the left ventricle to the finger. The second peak is formed in part by pressure transmitted along the aorta and large arteries to sites of impedance mismatch in the lower body. The contour of the PPG is sensitive to changes in arterial tone and is influenced by ageing and large artery stiffness. Measurements taken directly from the PPG or from its second derivative can be used to assess these properties. In some mathematical approaches, the extraction of periodic components using frequency analysis was tried to analysis of the PPG. But we don't understand yet what kind of factor in the cardiovascular system or human body is related with the respective specific Fourier components of PPG. This review describes the background to measurement principles, representative contour, contour analysis and frequency domain analysis of PPG, and current and future.

  • PDF

Measurement of Cardiac Pulse Transit Time using Photoplethysmography Sensor (광전용적맥파 센서를 이용한 맥파전달시간의 측정)

  • Choi, Byeong-Cheol;Jung, Dong-Keun;Jeong, Do-Un;Ro, Jung-Hun;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.383-391
    • /
    • 2004
  • In this study, we implemented the pulse transit time (PTT) system to examine usefulness of the monitoring method of distensibility and elasticity using photoplethysmography sensor in vivo. PTT is defined as the time interval between the peak of QRS complex in ECG signal and the maximum slope point of photoplethysmography. these two signals were converted to digital data by means of AID converter, then PTT was evaluated by heartbeat using PC. Results of analysis were displayed as a graph using spline interpolation method. The variance of PTT was measured repetitiously to verify efficiency of PTT system in resting state and hyperemic state. Repeated measurement of PTT was not same value but showed that coefficients of correlation were related with each other as 0.8302 (P<0.01) in resting state. And also repeated measurement of PTT showed significant correlation as 0.868 (P<0.01) in the hyperemic state. These result showed that PTT is reflect on transient pressure variance in the artery and is very useful method for the evaluation of prognosis of the hypertension and arteriosclerosis.

Treatment of Primary Hypertension by Oryung-san Monotherapy: a Case Report (오령산 단일 투여를 통한 일차성 고혈압 치험례)

  • Jang, In-Soo;Kim, Min-Ji;Han, Hyun-Jin;Jeong, Min-Jeong;Kang, Sei-Young
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.1
    • /
    • pp.106-110
    • /
    • 2014
  • Objectives : To report a case of the treatment of primary hypertension by Oryung-san (五苓散: Wulingsan in Chinese, Goreisan in Japanese) monotherapy. Methods : The blood pressure (BP) fluctuation was checked of a woman who had sudden BP elevation without a history of hypertension treatment. There were no specific history of disease and results for the laboratory examination and image diagnosis including MRI. The woman was diagnosed with primary hypertension and she was given supple of Oryung-san extract (Hanpoong Pharm Co.) 3 g, three times a day for three months. The BP has been checked with digital sphygmomanometer (HEM-7111, Omron Japan) in brachial artery at home. Results and Conclusions : The patient had had stable BP since three weeks after Oryung-san treatment was initiated. There were no subjective symptoms, then Oryung-san medication also had quit after three months treatments. This shows some possibility to control hypertension using Oryung-san, which resembles thiazide that acts on the distal convoluted tubule and inhibit sodium-chloride reabsorption. For further evaluation of the effectiveness, well-designed randomized controlled trials should be undertaken.