• 제목/요약/키워드: Digital Radiography Test

검색결과 84건 처리시간 0.022초

디지털 방사선투과영상의 정밀성 평가에 관한 연구 (An Assessment of the Accuracy for Digital Radiography Image)

  • 박상기;안연식;길두송
    • Journal of Welding and Joining
    • /
    • 제27권2호
    • /
    • pp.51-56
    • /
    • 2009
  • Film based radiography imaging technique has been applied to the non-destructive test in medical, aircraft, and power industries contributing to the development of the industries. However, the complex process for imaging and analysis has increasingly demanded the reformation of the radiography test. A digital radiography imaging technologies has been com out from the demand. This study was mainly focused on the assessment on the accuracy for the each image from digital radiography test and film radiography test was proven to crate a better image in sensitivity than film radiography test. In the IQI(Image quality indicator) transmission test, one or two more line can be seen in digital image than in film image. When applying to the boiler tube weld, film image is detectable to the 1.0mm depth flaw; and digital image to the 0.5mm depth flaw. As a result of this study, digital radiography technology is determined to enhance the image quality, compared to film radiography technologies

디지털 방사선 투과영상의 식별도 평가 연구 (The Study on Image Sensitivity Evaluation For Digital Radiography Image)

  • 박상기;이영호
    • 동력기계공학회지
    • /
    • 제12권6호
    • /
    • pp.70-77
    • /
    • 2008
  • The purpose of this study is to compare the quality of digital radiography image with that of classical film images for welded structure in power plants. The CMOS(Complementary Metal Oxide Semiconductor) flat panel detecter and Agfa D5 film are used to image flaw specimens respectively. In the test, CMOS flat panel detector has been determined to have a better image than that of film image. In the IQI(Image Quality Indicator) transmission test, one or two more line can be seen in digital image than in film image. Digital Radiography Test enabled to successfully detect all defects on the weld specimens fabricated with real reheat stem pipe and boiler tube as well. In the specific comparison test, Digital radiography test detected micro flaws in the size of 0.5 mm in length by 0.5 mm in depth. However, film test has limited it to 1.0 mm in length by 1.0 mm in depth. As a result of this study, digital radiography technology is estimated well enough to perform the inspection in the industry with far more cost effective way, compared to the classical film test.

  • PDF

CCD 디지털 방사선사진촬영법의 초기 치아우식증의 진단능 평가에 대한 연구 (Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries)

  • 이완;이병도
    • Imaging Science in Dentistry
    • /
    • 제33권1호
    • /
    • pp.27-33
    • /
    • 2003
  • Purpose : The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. Materials and Methods : 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOV A test. Results: The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p > 0.05). Coclusion : These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  • PDF

Direct digital radiography versus conventional radiography for estimation of canal length in curved canals

  • Mohtavipour, Seiedeh Tahereh;Dalili, Zahra;Azar, Nasim Gheshlaghi
    • Imaging Science in Dentistry
    • /
    • 제41권1호
    • /
    • pp.7-10
    • /
    • 2011
  • Purpose : The purpose of this study was to compare the conventional and digital radiography in the estimation of working length in mandibular molars. Materials and Methods : Sixty molar teeth were selected and divided into three groups in the basis of canal curves (0-$15^{\circ}$, 15-$30^{\circ}$, > $30^{\circ}$). After the placement of a 15 K-file, radiographs were taken with a conventional film (Fspeed) and a digital sensor. Canal lengths were measured in these images by two observers. Statistical analysis was performed with repeated measures of ANOVA and paired sample t-test with 95% confidence. Results : There was a high inter-observer agreement on the measurements of working length in conventional and digital radiographs. There was no significant difference between the mean values of measurements in conventional and digital radiography. Moreover, there was no significant difference between conventional and digital radiography with the actual values in the basis of canal curves. Conclusion : The accuracy of conventional and digital radiography in the determination of the working length was in an acceptable range.

디지털방사선사진과 구내방사선사진의 인접면 인공우식진단능에 관한 비교연구 (COMPARATIVE STUDY OF DIGITAL AND CONVENTIONAL RADIOGRAPHY FOR THE DIAGNOSTIC ABILITY OF ARTIFICIAL PROXIMAL SURFACE CARIES)

  • 조영곤;박시승
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.113-121
    • /
    • 2002
  • Conventional intraoral radiography continues to be the most widely used image modality for the diagnosis of dental caries. But, conventional intraoral radiography has several shortcomings, including the difficulty of exposing and processing intraoral film of consistently acceptable quality. In addition, radiographic retaking that was the result of processing errors, may result in increased discomfort and radiation dose to the patient. Recently, various digital radiographies substitute for conventional intraoral radiography to overcome these disadvantages. The advantages of digital radiography are numerous. One of advantages Is the elimination of processing errors. In addition, the radiation dose for digital system is approximately 20% to 25% of that required for conventional intraoral radiography Another potential advantage of digital imaging is the ability to perform image quality enhancements such as contrast and density modulation, which may increase diagnostic accuracy. The purpose of this study was to compare the diagnostic ability of artificial proximal defects to conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). Artificial defects were made in proximal surfaces of 60 extracted human molars using #1/2, #1, #2 round bur. Five dentists assessed proximal defects on conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). ROC(Receiver Operating Characteristic) analysis and Two-way ANOVA test were used for the evaluation of detectability, and following results were acquired. 1. The mean ROC area of conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital Image(Digora$^{\circledR}$) were 0.6766, 0.7538, 0.6791(Grade I), 0.7176, 0.7594, 0.7361(Grade II), and 0.7449, 0.7608, 0.7414(Grade III), respectively. 2. Diagnostic ability of direct digital image was higher than other image modalities. But, there was no statistically significant difference among other imaging modalities for Grade I, II, III lesion(p>0.05). In conclusion, when direct and indirect digital system are comparable with conventional intraoral radiography. these systems may be considered an alternative of conventional intraoral radiography for the diagnosis of proximal surface caries.

Digital radiography를 이용한 치근단 X선 사진의 판독능에 관한 실험적 연구 (A STUDY ON THE READABILITY OF PERIAPICAL RADIOGRAPH WITH THE DIGITAL RADIOGRAPHY)

  • 이곤;이상래
    • 치과방사선
    • /
    • 제22권1호
    • /
    • pp.117-127
    • /
    • 1992
  • This investigation was performed to test the readability of the video based digital radiography, that can be applied clinically, compared with the periapical radiograph. The experiments were performed with IBM-PC/AT compatible, video camera and ADC (analog-digital converter). And spatial resolution was 512 X 480 with 256 (8 bit) gray levels. The radiographs obtained by using variable steps of exposure time were digitized. and then the digital images were analyzed. The obtained results were as follows: 1. There was no remarkable difference in readability between the radiographs and their digital images. However, under over exposure the digital images were superior to the radiographs in readability and vice versa. 2. As the exposure time was increased, the gray level of the digital image was decreased proportionally. 3. The correlation beween the regions of interest and the aluminum step wedges were relatively close; R=0.9965 (p <0.001).

  • PDF

$CaWO_4/a-Se$ 구조의 X선 변환센서에서 a-Se의 Arsenic 첨가량에 따른 반응 특성 (The Response Characteristics of as Addition Ratio of Arsenic in $CaWO_4/a-Se$ based X-ray Conversion Sensor)

  • 강상식;석대우;조성호;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.416-419
    • /
    • 2002
  • There are being two prominent studying for Digital Radiography. Direct and Indirect method of Digital Radiography are announced for producing high quality digital image. The one is using amorphous selenium as photoconductor and the other is using phosphor layer as a light conversion. But each two systems have strength and weakness such as high voltage and blurring effect. In this study, we investigated the electrical characteristic of $multi-layer\left(CaWO_{4}+a-Se \right)$ as a photoconductor according to the changing arsenic composition ratio. This is a basic research for developing of Hybrid digital radiography which is a new type X-ray detector. The arsenic composition ratio of a-Se compound is classified into 7 different kinds which have 0.1%, 0.3%, 0.5%, 1%, 1.5%, 5%, 10% and were made test sample throught thermo-evaporation. The phosphor layer of $CaWO_4$ was overlapped on a-Se using EFIRON optical adhesives. We measured the dark and photo current about the test sample and compared the electrical characteristic of the net charge and signal-to-noise ratio. Among other things, test sample of compound material of 0.3% arsenic showed good characteristic of $2.45nA/cm^2$ dark current and $357.19pC/cm^2/mR$ net charge at $3V/{\mu}m$.

  • PDF

Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구 (A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System)

  • 홍선숙;김호철
    • 전자공학회논문지
    • /
    • 제50권12호
    • /
    • pp.247-253
    • /
    • 2013
  • 본 연구의 목적은 Direct DR(Digital Radiography), Indirect DR, I.I(Image Intensifier) DR에서 X선 광자 검출 방식에 따른 선량측정 및 획득된 영상을 정량적이고 객관적인 측정을 통해 DR System을 비교 평가 하는 것이다. Rando phantom을 사용하여 입사표면선량을 측정하였으며, 측정된 입사표면선량 값을 통해 PCXMC 프로그램을 사용하여 유효선량과 방사선 조사로 인한 위험을 평가하였다. 21cm 아크릴 phantom을 사용하여 SNR(Signal to Noise Ratio), NPS(Noise Power Spectrum), CNR(Contrast to Noise Ratio)을 측정하였으며, 측정값은 통계학적 분석기법을 사용하여 유의성을 평가하였다. 입사표면선량, 주요장기선량, 유효선량 모두 direct DR이 가장 낮게 측정되었으며, direct DR 선량을 기준으로 I.I type DR은 약 1.3배, indirect DR은 약 2.4배 높은 선량 비율로 측정되었다. 방사선량에 따른 위험도 역시 동일한 비율로 측정되었다. SNR 측정 결과 direct DR측정값을 기준으로 I.I DR은 약 7.25배, indirect DR이 약 1.48배 낮은 비율로 측정되었다. CNR 측정 결과 direct DR 측정값을 기준으로 I.I DR은 약 1.16배 높고, indirect DR이 약 0.87배 낮은 비율로 측정되었다. 따라서 a-selenium 검출소자를 사용하여 X선 광자를 검출하는 방식인 direct DR은 적은 선량으로 우수한 화질의 영상을 구현함으로써 선량에 민감한 소아나 생식선이 포함된 검사 등에 유용할 것으로 사료된다. 또한 많은 진단 정보를 위한 영상 평가가 요구되는 경우에는 indirect DR이 유용할 것으로 판단된다.

중첩 불일치 평가기준으로서의 계수공제영상의 계조도 표준편차 연구 (The Study of Standard Deviation of Gray Scale Histogram in Digital Subtraction Radiography as a Test Parameter for SuperimpoSition Error)

  • 조봉혜
    • 치과방사선
    • /
    • 제29권2호
    • /
    • pp.417-422
    • /
    • 1999
  • Purpose : The aim of this study was to assess the validity of standard deviation of gray scale histogram in digital subtraction radiography as a test parameter for superimposition error. Materials and Methods : Twenty periapical radiographs were used as baseline images and they were copied to exclude the influence of exposure geomety and contrast differences. These subsequent images were linearly displaced by 0.1-0.5 mm in the x-. y- and xy-directions, rotated by 0.5-3° and distorted by angular contraction of 1-5° in x- and y-axis before subtraction. The standard deviations of gray levels in the subtraction images were obtained and paired t-tests were performed. Pearson correlation coefficients(r) were calculated between the standard deviations and the superimposition errors. Results : Linear displacement showed high correlation coefficients of 0.997, 0.997 and 0.995 in x-. y- and xy-axis respectively. Statistically significant different standard deviation existed among all linearly displaced groups(p<0.05). Distortion showed relatively low correlation coefficients of 0.982 and 0.959 in x- and y-axis. The standard deviations between the two distortion groups were statistically significant different(p<0.05). Conclusion : Standard deviation of gray level distribution in digital subtraction images is satisfactory but not perfect similarity measure to assess the superimposition errors.

  • PDF

용접부에 대한 디지털 방사선투과영상과 필름 방사선투과영상의 상질 비교에 관한 연구 (Study on the Image Quality Comparison between in Digital RT and Film RT)

  • 박상기;안연식;길두송
    • 비파괴검사학회지
    • /
    • 제31권4호
    • /
    • pp.391-397
    • /
    • 2011
  • 용접부에 대한 품질 확보를 위하여 방사선투과시험을 실시하고 있으나 기존의 방사선투과시험은 필름을 사용한 아날로그 방법을 적용하고 있는데 비용과 시간이 많이 소요되고 시험 공정이 복잡하여 개선이 요구되고 있다. 본 연구에서는 용접부에 대한 디지털 방사선투과영상과 아날로그 방사선투과영상의 상질을 비교한 결과, 디지털 방사선투과영상은 디지털 영상 개선 과정으로 인하여 필름 영상에 비해 보다 세밀한 관찰을 할 수 있었다. 따라서 디지털 방사선투과시험이 개선이 요구되고 있는 기존 필름에 의한 방사선투과시험을 대체할 수 있을 것으로 평가된다.