• 제목/요약/키워드: Digital Power

검색결과 4,120건 처리시간 0.028초

대형 동기 발전기 계자제어를 위한 PWM 인버터에 관한 연구 (A Study of PWM Inverter for Field Control on Large Synchronous Generator)

  • 류호선;이주현;임익헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.958-959
    • /
    • 2006
  • For the life extension of Jeju thermal power plant, digital PWM excitation system was replaced by KEPRI. This system consist of TMR(Triple Modular Redundant) controller, dual PWM power inverter for field current control and MMI etc. The Performance test during the commissioning verified the reliability of digital PWM excitation system and recently, this system has been operated successfully.

  • PDF

Digital Control of Phase-Shifted Full-Bridge PWM Converter

  • Lim, Jeong-Gyu;Chung, Se-Kyo
    • Journal of Power Electronics
    • /
    • 제8권3호
    • /
    • pp.201-209
    • /
    • 2008
  • This paper presents the modeling and design of a digital controller for a phase-shifted full-bridge converter (PSFBC) in a discrete-time domain. The discretized PSFBC model is first derived and then analyzed considering the sampling effect and the system parameters. Based on this model, the digital controller is directly designed in a discrete-time domain. The simulation and experimental results are provided to show the validity of the proposed modeling and controller design.

CMOS Image Sensor에 사용 가능한 아날로그/디지탈 변환 (Analog to Digital Converter for CMOS Image Sensor)

  • 노주영;윤진한;장철상;손상희
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(2)
    • /
    • pp.137-140
    • /
    • 2002
  • This paper is proposed a 8-bit anolog to digital converter for CMOS image sensor. A anolog to digital converter for CMOS image sensor is required function to control gain. Proposed anolog to digital converter is used frequency divider to control gain. At 3.3 Volt power supply, total static power dissipation is 8mW and programmable gain control range is 30dB. The gain control range can be easily increased with insertion of additional flip-flop at divided-by-N frequency divider circuit.

  • PDF

DIGITAL CONTROL OF SINGLE PHASE BUCK-BOOST CONVERTER BY PULSE AREA MODULATION

  • Kim, T.J.;Byun, Y.B.;Joe, K.Y.;Kim, C.U.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.654-657
    • /
    • 1998
  • This paper is described a digital implementation of a pulse area modulation (PAM) method for a unity-power-factor buck-boost converter. A digital controller is designed and implemented by a Digital Signal Processor(DSP) to replace the analog control circuit for PAM. Experimental results are presented and compared with simulations.

  • PDF

PAM방식을 적용한 단상 승강압형 정류기의 디지탈제어 (Digital Control of Single Phase Buck-Boost Converter by Pulse Amplitude Modulation Mehtod)

  • 김태진;변영복;조기연;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.54-57
    • /
    • 1998
  • This paper describes a digital implementation of a pulse amplitude modulation(PAM) method for a unity-power-factor buck-booster converter. A digital controller is designed and implemented by a Digital Signal Processor(DSP) to replace the analog control circuit for PAM. Experimental results are presented and compared with simulations.

  • PDF

칼만필터링에 의한 디지털 거리계전 기법에 관한 연구 (A Study on the Digital Distance Relaying Techniques Using Kalman Filtering)

  • 김철환;박남옥;신명철
    • 대한전기학회논문지
    • /
    • 제41권3호
    • /
    • pp.219-226
    • /
    • 1992
  • In this study, Kalman filtering theory is applied to the estimation of symmetrical components from fault voltage and current signal when it comes to faults with the power system. An algorithm for estimating fault location accurately and quickly by calculating the symmetrical components from the extracted fundamental voltage phasor and current phasor is presented. Also, to confirm the validity of digital distance relaying techniques using Kalman filtering, the experimental results obtained by using the digital simulation of power system is shown.

  • PDF

Development of a Human Error Hazard Identification Method for Introducing Smart Mobiles to Nuclear Power Plants

  • Lee, Yong-Hee;Yun, Jong-Hun;Lee, Yong-Hee
    • 대한인간공학회지
    • /
    • 제31권1호
    • /
    • pp.261-269
    • /
    • 2012
  • Objective: The aim of this study is to develop an analysis method to extract plausible types of errors when using a smart mobile in nuclear power plants. Background: Smart mobiles such as a smart-phone and a tablet computer(smart-pad) are to be introduced to the various industries. Nuclear power plant like APR1400 already adopted many up-to-date digital devices within its main control room. With this trend, various types of smart mobiles will be inevitably introduced to the nuclear field in the near future. However nuclear power plants(NPPs) should be managed considering a big risk as a result of the trend not only economically but also socially compared to the other industrial systems. It is formally required to make sure to reasonably prevent the all hazards due to the introduction of new technologies and devices before the application to the specific tasks in nuclear power plants. Method: We define interaction segments(IS) as a main architect of interaction description, and enumerate all plausible error segments(ES) for a part of design evaluation of digital devices. Results: We identify various types of interaction errors which are coped with reasonably by interaction design using smart mobiles. Conclusion: According to the application result of the proposed method, we conclude that the proposed method can be utilized to specify the requirements to the human error hazards in digital devices, and to conduct a human factors review during the design of digital devices. Application: The proposed method can be applied to predict the human errors of the tasks related to the digital devices; therefore we can ensure the safety to apply the digital devices to be introduced to NPPs.

500MW급 표준화력발전소 시뮬레이터 모델을 이용한 디지털 제어시스템 검증 (Digital Control System Validation using the Simulator Models for 500MW Standard Type Fossil Power Plant)

  • 서정관;이명수;홍진혁
    • 한국시뮬레이션학회논문지
    • /
    • 제19권3호
    • /
    • pp.71-79
    • /
    • 2010
  • 디지털 계측제어계통을 발전소에 적용하기 전에 시험 및 검증하기 위하여 500MW급 표준화력발전소 시뮬레이터 모델을 개발하고 터빈 제어시스템과 연계하였다. 선택된 디지털 계측제어계통의 성능시험 시, 해당되는 시뮬레이터 모델은 조정할 수 없는 발전소 디지털 계측제어계통과 교체된다. 시뮬레이터 모델 및 제어시스템의 입출력은 연계장치에 있는 LabView 프로그램을 사용하여 연결되었다. 본 논문에서는 시뮬레이터 모델 및 디지털 계측제어계통을 연계하는 방법론에 대하여 기술하고, 정상운전, 과도상태 및 고장인가 시 수행된 검증시험 결과를 제시하였다. 시뮬레이터 모델을 사용한 디지털 계측제어계통의 종합검증을 통하여 시뮬레이터가 디지털 제어시스템을 발전소에 적용하기 위한 시험장치로 사용될 수 있는 방법론을 개발하였다.

A GaAs Power MESFET Operating at 3.3V Drain Voltage for Digital Hand-Held Phone

  • Lee, Jong-Lam;Kim, Hae-Cheon;Mun, Jae-Kyung;Kwon, Oh-Seung;Lee, Jae-Jin;Hwang, In-Duk;Park, Hyung-Moo
    • ETRI Journal
    • /
    • 제16권4호
    • /
    • pp.1-11
    • /
    • 1995
  • A GaAs power metal semiconductor field effect transistor (MESFET) operating at a voltage as low as 3.3V has been developed with the best performance for digital handheld phone. The device has been fabricated on an epitaxial layer with a low-high doped structure grown by molecular beam epitaxy. The MESFET, fabricated using $0.8{\mu}m$ design rule, showed a maximum drain current density of 330 mA/mm at $V_{gs}$ =0.5V and a gate-to-drain breakdown volt-age of 28 V. The MESFET tested at a 3.3 V drain bias and a 900 MHz operation frequency displayed an output power of 32.5-dBm and a power added efficiency of 68%. The associate power gain at 20 dBm input power and the linear gain were 12.5dB and 16.5dB, respectively. Two tone testing measured at 900.00MHz and 900.03MHz showed that a third-order intercept point is 49.5 dBm. The power MESFET developed in this work is expected to be useful as a power amplifying device for digital hand-held phone because the high linear gain can deliver a high power added efficiency in the linear operation region of output power and the high third-order intercept point can reduce the third-order intermodulation.

  • PDF