• 제목/요약/키워드: Digital Imaging Sensor

검색결과 85건 처리시간 0.024초

Diagnostic accuracy of artificially induced vertical root fractures: a comparison of direct digital periapical images with conventional periapical images

  • Lee Ji-Un;Kwon Ki-Jeong;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • 제34권4호
    • /
    • pp.185-190
    • /
    • 2004
  • Purpose: To compare the diagnostic accuracy for the detection of root fractures in CMOS-based digital periapical images with conventional film-based periapical images. Materials and Methods: Sixty extracted single-root human teeth with closed apices were prepared endodontically and divided into two groups; artificially induced vertical root fracture group and control group. All radiographs were obtained using the paralleling technique. The radiographs were examined by 4 observers three times within a 4 week interval. Receiver operating characteristic (ROC) analysis was carried out using data obtained from four observers. Intra- and inter-examiner agreements were computed using kappa analysis. Results: The area under the ROC curve (Az) was used as an indicator of the diagnostic accuracy of the imaging system. Az values were as follows: direct-digital images; 0.93, film-based images; 0.92, and inverted digital images; 0.91. There was no significant difference between imaging modalities (P<0.05). The kappa value of inter-observer agreement was 0.42 (range: 0.28-0.60) and intra-observer agreement was 0.57 (range: 0.44-0.75). Conclusion : There is no statistical difference in diagnostic accuracy for the detection of vertical root fractures between digital periapical images and conventional periapical images. The results indicate that the CMOS sensor is a good image detector for the evaluation of vertical root fractures.

  • PDF

a-Se을 이용한 디지털 X-선 검출기의 Discharge Erasing Method에 관한 연구 (Study of Discharge Erasing Method of a-Se based Digital X-ray Detector)

  • 이동길;박지군;최장용;강상식;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.395-398
    • /
    • 2002
  • Many research group started study to develope x-ray detector using thin film transistor from 1970. But realization of TFT based x-ray detector development was caused by progress of thin film transistor liquid crystal display(TFTLCD) device technology in 1990. The main current of TFT technology is display device. Research results expend TFT technology field from display device to sensor manufacture technology. These days many research group in the world realize various digital x-ray detector. In this study, We compare discharge erasing method to visible light erasing method in a-Se based digital x-ray detector. Visible light erasing method is known reset process in direct conversion x-ray detector. Digital x-ray detector using visible light erasing method is not adaptive for conventional x-ray device, because of its thickness. And it is not avaliable for real-time imaging for digital fluoroscopy, because of its long reset time. In this study we overcome these limitations and show new idea for real-time imaging method.

  • PDF

Bar 타겟을 이용한 DMC 영상의 공간해상력 검증 (Verification of Spatial Resolution in DMC Imagery using Bar Target)

  • 이태윤;이재원;윤부열
    • 한국측량학회지
    • /
    • 제30권5호
    • /
    • pp.485-492
    • /
    • 2012
  • 최근 디지털 항공영상 센서는 다양한 국가 공간정보기반구축에 큰 역할을 하고 있다. 하지만 고정밀의 신뢰성 있는 자료를 확보하기 위해서는 취득된 디지털영상에 대한 적절한 품질 평가 작업이 선행되어야 한다. 따라서 현재 관련분야의 연구가 국내외적으로 크게 주목을 받고 있다. 디지털카메라의 성능을 테스트하기 위한 영상해상력 검증용 테스트필드가 유럽과 미국 등에서 이미 설치 및 활용되고 있다. 이러한 테스트필드에는 카메라의 기하학적 성능분석을 위한 대공표지를 비롯하여 공간해상력 및 방사해상력 분석을 위한 다양한 형태의 타겟 역시 설치되어 있다. 본 연구에서는DMC 카메라의 공간해상력을 검증하기 위하여 영상에서 인식 가능한 크기의 바 타겟(bar target)을 제작 설치 후 항공촬영을 수행하였다. 연구에 사용된 DMC 영상의 이론적인 지상표본거리(GSD ; Ground Sample Distance)는 12cm 급으로, 촬영 비행방향과 비행방향의 직각방향에 대하여 보조영상과 집성영상에 대하여 각각 실제 해상력을 분석하였다. 연구결과 이론적인 해상력과 영상의 실제 해상력간의 차이는 약 0.6cm로 나타났으며, 블록의 가장자리에 위치한 영상에서 최대 1.5cm 정도로 나타났다.

대칭형 공차를 갖는 플로팅 광학계의 상면 변화 보정 방법에 대한 통계적 해석 (Statistical Analysis of Focus Adjustment Method for a Floating Imaging System with Symmetric Error Factors)

  • 류재명;김용수;조재흥;강건모;이해진;이혁기
    • 한국광학회지
    • /
    • 제23권5호
    • /
    • pp.189-196
    • /
    • 2012
  • 플로팅 광학계는 초점 맞춤 시, 2개 이상의 군이 움직이는 광학계를 의미한다. 카메라 광학계에서는 매크로 렌즈와 같이 배율 변화가 큰 광학계에 주로 채용된다. 플로팅 광학계도 가공 및 조립 오차로 인해 무한대단 및 매크로단의 초점위치가 촬상소자의 결상면과 일치하지 않는다. 그러므로 제조공정상에서 이러한 BWD(Back Working Distance) 차이를 최소화하는 초점 조정을 해야 한다. 본 논문에서는 플로팅 광학계의 각 군들의 이동량을 결정하기 위하여 초점 조정에 필요한 캠 회전각을 계산하고, 초점조정에 따른 플로팅 광학계의 최대 배율도 보정하는 수치해석 방법을 제안하였다. 그리고 이를 이용하여 대칭형 공차를 갖는 플로팅 광학계의 제조 오차를 고려한 초점 조정에 필요한 캠 회전각의 분포를 통계학적으로 계산하여 캠 회전각의 허용 범위를 결정하는 방법도 제안하였다.

적외선 영상기법에 의한 CCD 센서의 스펙트럼 응답 특성 분석 기법 (Apparatus and method for analysing spectral response of a CCD optical sensor using an infrared imaging technique)

  • 강성준;나철훈;박순영
    • 전자공학회논문지SC
    • /
    • 제43권3호
    • /
    • pp.25-30
    • /
    • 2006
  • 디지털 영상처리를 이용해 CCD 센서의 스펙트럼 응답특성을 직접 측정할 수 있는 적외선 영상기법을 제안하고 있다. 이 방법은 쉽고 경제적인 방법으로 상용 CCD 센서의 스펙트럼 감도를 검출할 수 있도록 한다. 본 장치의 핵심 부품은 단색광원기, CCD 지지대, 디지털 영상처리 시스템이 내장된 컴퓨터이다. 방법의 타당성을 증명하기 위해 상용 CCD 카메라에 대해 시험적으로 행한 실험은 이론적인 모델과 잘 일치함을 보여 주었다.

비정질 실리콘 디지털 방사선 촬영기의 개발 (Development of Amorphous Silicon Based Digital Radiography System)

  • 이형구;서태석;최보영;신경섭;김홍권
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.94-95
    • /
    • 1998
  • We developed a digital x-ray medical imaging system using commercially available amorphous silicon image sensor plate. The image readout could be accomplished within 3.5 sec after radiation exposure and be displayed on a monitor through computer interface. This system needs not the conventional x-ray films and film processors, and also provides digital radiographic images. This system is the fastest digital radiography system developed so far, and expected to replace many of the conventional x-ray film systems or digital radiography systems.

  • PDF

영상의학 검사 판독용 모니터 정도관리 Guiding Instrument 제작과 유용성 고찰 (A Study on Production and Its Usefulness of AAPM TG18 Guiding Instrument for Diagnostic Monitor QC)

  • 손기경;성동욱;정재호;강희두;류경남
    • 대한디지털의료영상학회논문지
    • /
    • 제10권1호
    • /
    • pp.21-28
    • /
    • 2008
  • Diagnostic display monitor QA according to AAPM TG18 is usually performed by PACS administrator, product manager and reading doctor, and for acceptance testing and periodic quality control evaluation, a combination of visual and quantitative tests can be used, as outlined in sections 5 and 6 of 'assessment of display performance for medical imaging systems'. Although many display tests can be performed visually, a more objective and quantitative evaluation of display performance requires special test tools. The required instruments vary in their complexity and cost, depending on the context of the evaluation(research, acceptance testing, or quality control) and how thorough the evaluation needs to be. Objective and reliable assessment of many display characteristics can be performed with relatively inexpensive equipment, So, we made 'AAPM TG18 guiding instrument' to ues variable purpose of the evaluation of 'geometrical distortions(quantitative"', 'veiling glare(visual)' and 'sensor calibration'. The spatial measurements for the quantitative evaluation of geometric distortions, and the measurement of the veling-glare ring response function which provides information regarding the spatial extent of the luminance spread, can be performed using the TG18 guiding instrument can be used to sensor calibration to standardize the basic rate of 0% luminance when periodic calibration.

  • PDF

Sub-surface imaging and vector precision from high resolution down-hole TEM logging

  • Chull, James;Massie, Duncan
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2005년도 제7회 특별심포지움 논문집
    • /
    • pp.11-18
    • /
    • 2005
  • Filament inversion routines are highly effective for target definition whenever total-field DHTEM vectors can be obtained using three-component logging tools. However most cross-hole components contain significant noise related to sensor design and errors in observation of probe rotation. Standard stacking methods can be used to improve data quality but additional statistical methods based on cross-correlation and spatial averaging of orthogonal components may be required to ensure a consistent vector migration path. Apart from assisting with spatial averaging, multiple filaments generated for successive time-windows can provide additional imaging information relating to target geometry and current migration. New digital receiver systems provide additional time-windows to provide better tracking options necessary for high-resolution imaging of this type.

  • PDF

X-ray Sensitivity of Hybrid-type Sensor based on CaWO4-Selenium for Digital X-ray Imager

  • Park, Ji-Koon;Park, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Kim, Jae-Hyung;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제5권4호
    • /
    • pp.133-137
    • /
    • 2004
  • The development of digital x-ray detector has been extensively progressed for the application of various medical modalities. In this study, we introduce a new hybrid-type x-ray detector to improve problems of a conventional direct or indirect digital x-ray image technology, which composed of multi-layer structure using a CaWO$_4$ phosphor and amorphous selenium (a-Se) photoconductor. The leakage current of our detector was found to be ∼180 pA/cm$^2$ at 10 V/m, which was significantly reduced than that of a single a-Se detector. The x-ray sensitivity was measured as the value of 4230 pC/cm$^2$/mR at 10 V/m. We found that the parylene thin film between a CaWO$_4$ phosphor and an a-Se layer acts as an insulator to prevent charge injection from indium thin oxide (ITO) electrode into an a-Se layer under applied bias.

비행 드론을 위한 G-센서 기반의 직관적 제어기 (Intuitive Controller based on G-Sensor for Flying Drone)

  • 신판섭;김선경;김정민
    • 디지털융복합연구
    • /
    • 제12권1호
    • /
    • pp.319-324
    • /
    • 2014
  • 최근 들어 고성능 비행 드론이 주목받고 있다. 특히, 다중 로터를 장착한 헬기 형태의 비행 드론은 항공촬영, 방송영상제작, 항공구조, 물류배송, 감시, 측량, 방역 방제, 군사용 등으로 그 활용범위를 확장해가고 있다. 그러나 이를 조종하는 제어기의 형태는 매우 단순하다. 따라서 본 연구에서는 모바일 기기에 탑재된 G-센서를 이용하여 사용자의 직관적인 동작으로 비행 드론을 조종할 수 있는 향상된 제어기를 구현한다. 구현된 제어기는 신경망 알고리즘을 사용하여 동작 인식 성능을 향상시켰다.