• Title/Summary/Keyword: Digital Application

Search Result 4,110, Processing Time 0.032 seconds

The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy (용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가)

  • Lee, Dong Hyung;Bae, Sun Myung;Kwak, Jung Won;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • Purpose: The accurate movement of gantry rotation, collimator and correct application of dose rate are very important to approach the successful performance of Volumetric Modulated Arc Therapy (VMAT), because it is tightly interlocked with a complex treatment plan. The interruption and restart of dose delivery, however, are able to occur on treatment by various factors of a treatment machine and treatment plan. If unexpected problems of a treat machine or a patient interrupt the VMAT, the movement of treatment machine for delivering the remaining dose will be restarted at the start point. In this investigation, We would like to know the effect of interruptions and restart regarding dose delivery at VMAT. Materials and Methods: Treatment plans of 10 patients who had been treated at our center were used to measure and compare the dose distribution of each VMAT after converting to a form of digital image and communications in Medicine (DICOM) with treatment planning system (Eclipse V 10.0, Varian, USA). We selected the 6 MV photon energy of Trilogy (Varian, USA) and used OmniPro I'mRT system (V 1.7b, IBA dosimetry, Germany) to analyze the data that were acquired through this measurement with two types of interruptions four times for each case. The door interlock and the beam-off were used to stop and then to restart the dose delivery of VMAT. The gamma index in OmniPro I'mRT system and T-test in Microsoft Excel 2007 were used to evaluate the result of this investigation. Results: The deviations of average gamma index in cases with door interlock, beam-off and without interruption on VMAT are 0.141, 0.128 and 0.1. The standard deviations of acquired gamma values are 0.099, 0.091, 0.071 and The maximum gamma value in each case is 0.413, 0.379, 0.286, respectively. This analysis has a 95-percent confidence level and the P-value of T-test is under 0.05. Gamma pass rate (3%, 3 mm) is acceptable in all of measurements. Conclusion: As a result, We could make sure that the interruption of this investgation are not enough to seriously affect dose delivery of VMAT by analyzing the measured data. But this investigation did not reflect all cases about interruptions and errors regarding the movement of a gantry rotation, collimator and patient So, We should continuously maintain a treatment machine and program to deliver the accurate dose when we perform the VMAT for the many kinds of cancer patients.

  • PDF

Development and Application of an After-school Program for an Astronomy Observation Club in a Highschool: Standardized Coefficient Decision Program in Consideration of the Observation Site's Environment (고등학교 천체 관측 동아리를 위한 방과 후 학교 프로그램 개발 및 적용: 관측지 주변 환경을 고려한 표준화 계수 결정 프로그램)

  • Kim, Seung-Hwan;Lee, Hyo-Nyong;Lee, Hyun-Dong;Jeong, Jae-Hwa
    • Journal of the Korean earth science society
    • /
    • v.29 no.6
    • /
    • pp.495-505
    • /
    • 2008
  • The main purposes of this study are to: (1) to develop astronomy observation program based on a standardized coefficient decision program; and (2) to apply the developed program to after-school or club activities. As a first step, we analyzed activities related to astronomy in the authorized textbooks that are currently adopted in high schools. based on the analysis, we developed an astronomy observation program according to the standardized coefficient decision program, and the program was applied to students' astronomical observations as part of the club activities. Specifically, this program used a 102 mm refracting telescope and digital camera. we took into account the observation site's environment of the urban areas in which many school were located and then developed a the computer program for observation activities. The results of this study are as follows. First, the current astronomical education in schools was based off of the textbooks. Specifically, it was mostly about analyzing the materials and making simulated experiments. Second, most schools participated in this study were located in urban areas where students had more difficulty in observation than in rural areas. Third, an exemplary method was investigated in order to make an astronomical observation efficiently in urban areas with the existing devices. In addition, the standardized coefficient decision program was developed to standardize the magnitude of stars according to the observed value. Finally, based on the students' observations, we found that there was no difference between the magnitude of a star in urban sites and in rural sites. The current astronomical education in schools lacks an activity of practical experiments, and many schools have not good observational sites because they are located in urban areas. However, use of this program makes it possible to collect significant data after a series of standardized corrections. In conclusion, this program not only helps schools to create an active astronomy observation activity in fields, but also promotes students to be more interested in astronomical observation through a series of field-based activities.

The Properties of Beam Intensity Scanner (BInS) for Dose Verification in Intensity Modulated Radiation Therapy (방사선 세기 조절 치료에서 선량을 규명하는 데 사용된 BlnS System의 특성)

  • 박영우;박광열;박경란;권오현;이명희;이병용;지영훈;김근묵
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Patient dose verification is one of the most Important responsibilities of the physician in the treatment delivery of radiation therapy. For the task, it is necessary to use an accurate dosimeter that can verify the patient dose profile, and it is also necessary to determine the physical characteristics of beams used in intensity modulated radiation therapy (IMRT) The Beam Intensity Scanner (BInS) System is presented for the dosimetric verification of the two dimensional photon beam. The BInS has a scintillator, made of phosphor Terbium-doped Gadolinium Oxysulphide (Gd$_2$O$_2$S:Tb), to produce fluorescence from the irradiation of photon and electron beams. These fluoroscopic signals are collected and digitized by a digital video camera (DVC) and then processed by custom made software to express the relative dose profile in a 3 dimensional (3D) plot. As an application of the BInS, measurements related to IWRT are made and presented in this work. Using a static multileaf collimator (SMLC) technique, the intensity modulated beam (IMB) is delivered via a sequence of static portals made by controlled leaves. Thus, when static subfields are generated by a sequence of abutting portals, the penumbras and scattered photons of the delivered beams overlap in abutting field regions and this results in the creation of “hot spots”. Using the BInS, inter-step “hot spots” inherent in SMLC are measured and an empirical method to remove them is proposed. Another major MLC technique in IMRT, the dynamic multileaf collimator (DMLC) technique, has different characteristics from SMLC due to a different leaf operation mechanism during the irradiation of photon and electron beams. By using the BInS, the actual delivered doses by SMLC and DMLC techniques are measured and compared. Even if the planned dose to a target volume is equal in our experimental setting, the actual delivered dose by DMLC technique is measured to be larger by 14.8% than that by SMLC, and this is due to scattered photons and contaminant electrons at d$_{max}$.

  • PDF

Study of the UAV for Application Plans and Landscape Analysis (UAV를 이용한 경관분석 및 활용방안에 관한 기초연구)

  • Kim, Seung-Min
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.3
    • /
    • pp.213-220
    • /
    • 2014
  • This is the study to conduct the topographical analysis using the orthophotographic data from the waypoint flight using the UAV and constructed the system required for the automatic waypoint flight using the multicopter.. The results of the waypoint photographing are as follows. First, result of the waypoint flight over the area of 9.3ha, take time photogrammetry took 40 minutes in total. The multicopter have maintained the certain flight altitude and a constant speed that the accurate photographing was conducted over the waypoint determined by the ground station. Then, the effect of the photogrammetry was checked. Second, attached a digital camera to the multicopter which is lightweight and low in cost compared to the general photogrammetric unmanned airplane and then used it to check its mobility and economy. In addition, the matching of the photo data, and production of DEM and DXF files made it possible to analyze the topography. Third, produced the high resolution orthophoto(2cm) for the inside of the river and found out that the analysis is possible for the changes in vegetation and topography around the river. Fourth, It would be used for the more in-depth research on landscape analysis such as terrain analysis and visibility analysis. This method may be widely used to analyze the various terrains in cities and rivers. It can also be used for the landscape control such as cultural remains and tourist sites as well as the control of the cultural and historical resources such as the visibility analysis for the construction of DSM.

The application of photographs resources for constructive social studies (구성주의적 사회과 교육을 위한 사진자료 활용방안)

  • Lee, Ki-Bok;Hwang, Hong-Seop
    • Journal of the Korean association of regional geographers
    • /
    • v.6 no.3
    • /
    • pp.117-138
    • /
    • 2000
  • This study is, from the view point of constructive social studies which is the foundation of the 7th curriculum, to explore whether there is any viable program and to investigate it by which students, using photo resources in social studies, can organize their knowledge in the way of self-directed thinking. The main results are as follows: If it is a principle of knowledge construction process of constructive social studies that individual construction (cognitive construction) develops into communal construction(social construction) and yet communal construction develops itself, interacting with individual construction, it will be meet the objectives of social studies. In social studies, photos are a powerful communication tool. communicating with photos enables to invoke not only the visual aspects but also invisible aspects of social phenomena from photos. It, therefore, can help develop thinking power through inquiry learning, which is one of the emphasis of the 7th curriculum. Having analyzed photo resources appeared on the regional textbooks in elementary social studies, they have been appeared that even though the importance and amount of space photo resources occupy per page is big with regard to total resources, most of the photos failed to lad to self-directed thinking but just assistant material in stead. Besides, there appeared some problems with the title, variety, size, position, tone of color, visibility of the photos, and further with the combination of the photos. Developing of photo resources for constructive social studies is to overcome some problems inherent in current text books and to reflect the theoretical background of the 7th curriculum. To develop the sort of photo that can realize the point just mentioned, it would be highly preferable to provide photo database to facilitate study with homepage through web-based interaction. To take advantage of constructive photo resources, the instruction is strategized in four stages, intuition, conflict, accommodation, and equilibration stage. With the advancement of the era of image culture, curriculum developers are required to develop dynamic, multidimensional digital photos rather than static photos when develop text books.

  • PDF

The Evaluation of Reconstructed Images in 3D OSEM According to Iteration and Subset Number (3D OSEM 재구성 법에서 반복연산(Iteration) 횟수와 부분집합(Subset) 개수 변경에 따른 영상의 질 평가)

  • Kim, Dong-Seok;Kim, Seong-Hwan;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2011
  • Purpose: Presently in the nuclear medicine field, the high-speed image reconstruction algorithm like the OSEM algorithm is widely used as the alternative of the filtered back projection method due to the rapid development and application of the digital computer. There is no to relate and if it applies the optimal parameter be clearly determined. In this research, the quality change of the Jaszczak phantom experiment and brain SPECT patient data according to the iteration times and subset number change try to be been put through and analyzed in 3D OSEM reconstruction method of applying 3D beam modeling. Materials and Methods: Patient data from August, 2010 studied and analyzed against 5 patients implementing the brain SPECT until september, 2010 in the nuclear medicine department of ASAN medical center. The phantom image used the mixed Jaszczak phantom equally and obtained the water and 99mTc (500 MBq) in the dual head gamma camera Symbia T2 of Siemens. When reconstructing each image altogether with patient data and phantom data, we changed iteration number as 1, 4, 8, 12, 24 and 30 times and subset number as 2, 4, 8, 16 and 32 times. We reconstructed in reconstructed each image, the variation coefficient for guessing about noise of images and image contrast, FWHM were produced and compared. Results: In patients and phantom experiment data, a contrast and spatial resolution of an image showed the tendency to increase linearly altogether according to the increment of the iteration times and subset number but the variation coefficient did not show the tendency to be improved according to the increase of two parameters. In the comparison according to the scan time, the image contrast and FWHM showed altogether the result of being linearly improved according to the iteration times and subset number increase in projection per 10, 20 and 30 second image but the variation coefficient did not show the tendency to be improved. Conclusion: The linear relationship of the image contrast improved in 3D OSEM reconstruction method image of applying 3D beam modeling through this experiment like the existing 1D and 2D OSEM reconfiguration method according to the iteration times and subset number increase could be confirmed. However, this is simple phantom experiment and the result of obtaining by the some patients limited range and the various variables can be existed. So for generalizing this based on this results of this experiment, there is the excessiveness and the evaluation about 3D OSEM reconfiguration method should be additionally made through experiments after this.

  • PDF

A Study on Protection Performance of Radiation Protective Aprons classified by Manufacturers and Lead Equivalent using Over Tube Type Fluoroscopy (Over Tube Type의 투시촬영장치를 이용한 제조사별, 납당량별 엑스선방어 앞치마의 Protection 성능 평가에 관한 연구)

  • Song, Jong-Nam;Seol, Gwang-Wook;Hong, Seong-Il;Choi, Jeong-Gu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.135-141
    • /
    • 2011
  • If protective performance of apron cannot be good, radiation exposure of an guardian or a patient, a person engaged in radiation related industry cannot rise. Therefore, It will be evaluated protection performance to radiation protection aprons by manufacturers and lead equivalent more than 0.25mm lead equivalent. And, will show in the direction of application to clinic. The new aprons by manufacturers(H, X, I, J company) and lead equivalent(0.50mmPb, 0.35mmPb, 0.25mmPb) measured transmitted dose rate and shielding rate, uniformity under fluoroscopy and general radiography using to fluoroscopy system and digital radiography system, x-ray multifunction meter. The shielding rate measurement results, 0.5mmPb apron was Shielding rate of apron of a I company(fluoroscopy : 97.96%) was the best under six companies, and shielding rate of apron of a J company(fluoroscopy : 96.25%) was worst. 0.35mmPb Apron was Shielding rate of a I company(fluoroscopy : 96.79%) was the best under the three companies, and shielding rate of an H company(fluoroscopy : 95.81%) was the worst. 0.25mmPb Apron was Shielding rate of X company apron(fluoroscopy : 90.908%) was better than H company apron(fluoroscopy : 88.82%) than two companies. The uniformity measurement results, 0.5mmPb Aprons of X company(fluoroscopy : 0.13) and I company(fluoroscopy : 0.19) was the best under the six companies, and J company apron(fluoroscopy : 0.45) was the worst. 0.35mmPb. Along a manufacturer and lead equivalent performance of apron protection is distinguished certainly. Therefore, a patient, guardian or a person engaged in radiation related industry shall enforce experiment of a lot of ways defined or evaluation so that the maximum reduces radiation exposure. Buy the apron that protective performance is good, It will be performed through experiment and evaluation.

Suitability Classes for Italian Ryegrass (Lolium multiflorum Lam.) Using Soil and Climate Digital Database in Gangwon Province (강원도에서 토양과 기후 데이터베이스를 이용한 이탈리안 라이그라스의 재배 적지 구분)

  • Kim, Kyung-Dae;Sung, Kyung-Il;Jung, Yeong-Sang;Lee, Hyun-Il;Kim, Eun-Jeong;Nejad, Jalil Ghassemi;Jo, Mu-Hwan;Lim, Young-Chul
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.32 no.4
    • /
    • pp.437-446
    • /
    • 2012
  • As a part of establishing suitability classification for forage production, use of the national soil and climate database was attempted for Italian ryegrass (Lolium multiflorum Lam., IRG) in Gangwon Province. The soil data base were from Heugtoram of the National Academy of Agricultural Science, and the climate data base were from the National Center for Agro-Meteorology, respectively. Soil physical properties including soil texture, drainage, slope available depth and surface rock contents, and soil chemical properties including soil acidity and salinity, organic matter content were selected as soil factors. The crieria and weighting factors of these elements were scored. Climate factors including average daily minimum temperature, average temperature from March to May, the number of days of which average temperature was higher than $5^{\circ}C$ from September to December, the number of days of precipitation and its amount from October to May of the following year were selected, and criteria and weighting factors were scored. The electronic maps were developed with these scores using the national data base of soil and climate. Based on soil scores, the area of Goseong, Sogcho, Gangreung, and Samcheog in east coastal region with gentle slope were classified as the possible and/or the proper area for IRG cultivation in Gangwon Province. The lands with gentle or moderate slope of Cheolwon, Yanggu, Chuncheon, Hweongseong, Pyungchang and Jeongsun in west side slope of Taebaeg mountains were classified as the possible and/or proper area as well. Based on climate score, the east coastal area of Goseong, Sogcho, Yangyang, Gangreung and Samcheog could be classified as the possible or proper area. Most area located on west side of the Taebaeg mountains were classified as not suitable for IRG production. In scattered area in Chuncheon and Weonju, where the scores exceeded 60, the IRG cultivation should be carefully managed for good production. For better application of electronic maps.

Design and Implementation of Medical Information System using QR Code (QR 코드를 이용한 의료정보 시스템 설계 및 구현)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • The new medical device technologies for bio-signal information and medical information which developed in various forms have been increasing. Information gathering techniques and the increasing of the bio-signal information device are being used as the main information of the medical service in everyday life. Hence, there is increasing in utilization of the various bio-signals, but it has a problem that does not account for security reasons. Furthermore, the medical image information and bio-signal of the patient in medical field is generated by the individual device, that make the situation cannot be managed and integrated. In order to solve that problem, in this paper we integrated the QR code signal associated with the medial image information including the finding of the doctor and the bio-signal information. bio-signal. System implementation environment for medical imaging devices and bio-signal acquisition was configured through bio-signal measurement, smart device and PC. For the ROI extraction of bio-signal and the receiving of image information that transfer from the medical equipment or bio-signal measurement, .NET Framework was used to operate the QR server module on Window Server 2008 operating system. The main function of the QR server module is to parse the DICOM file generated from the medical imaging device and extract the identified ROI information to store and manage in the database. Additionally, EMR, patient health information such as OCS, extracted ROI information needed for basic information and emergency situation is managed by QR code. QR code and ROI management and the bio-signal information file also store and manage depending on the size of receiving the bio-singnal information case with a PID (patient identification) to be used by the bio-signal device. If the receiving of information is not less than the maximum size to be converted into a QR code, the QR code and the URL information can access the bio-signal information through the server. Likewise, .Net Framework is installed to provide the information in the form of the QR code, so the client can check and find the relevant information through PC and android-based smart device. Finally, the existing medical imaging information, bio-signal information and the health information of the patient are integrated over the result of executing the application service in order to provide a medical information service which is suitable in medical field.

Design of a Bit-Serial Divider in GF(2$^{m}$ ) for Elliptic Curve Cryptosystem (타원곡선 암호시스템을 위한 GF(2$^{m}$ )상의 비트-시리얼 나눗셈기 설계)

  • 김창훈;홍춘표;김남식;권순학
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.12C
    • /
    • pp.1288-1298
    • /
    • 2002
  • To implement elliptic curve cryptosystem in GF(2$\^$m/) at high speed, a fast divider is required. Although bit-parallel architecture is well suited for high speed division operations, elliptic curve cryptosystem requires large m(at least 163) to support a sufficient security. In other words, since the bit-parallel architecture has an area complexity of 0(m$\^$m/), it is not suited for this application. In this paper, we propose a new serial-in serial-out systolic array for computing division operations in GF(2$\^$m/) using the standard basis representation. Based on a modified version of tile binary extended greatest common divisor algorithm, we obtain a new data dependence graph and design an efficient bit-serial systolic divider. The proposed divider has 0(m) time complexity and 0(m) area complexity. If input data come in continuously, the proposed divider can produce division results at a rate of one per m clock cycles, after an initial delay of 5m-2 cycles. Analysis shows that the proposed divider provides a significant reduction in both chip area and computational delay time compared to previously proposed systolic dividers with the same I/O format. Since the proposed divider can perform division operations at high speed with the reduced chip area, it is well suited for division circuit of elliptic curve cryptosystem. Furthermore, since the proposed architecture does not restrict the choice of irreducible polynomial, and has a unidirectional data flow and regularity, it provides a high flexibility and scalability with respect to the field size m.