• Title/Summary/Keyword: Diffusion weighted magnetic resonance imaging

Search Result 191, Processing Time 0.03 seconds

Diffusion Weighted Imaging Can Distinguish Benign from Malignant Mediastinal Tumors and Mass Lesions: Comparison with Positron Emission Tomography

  • Usuda, Katsuo;Maeda, Sumiko;Motono, Nozomu;Ueno, Masakatsu;Tanaka, Makoto;Machida, Yuichiro;Matoba, Munetaka;Watanabe, Naoto;Tonami, Hisao;Ueda, Yoshimichi;Sagawa, Motoyasu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6469-6475
    • /
    • 2015
  • Background: Diffusion-weighted magnetic resonance imaging (DWI) makes it possible to detect malignant tumors based on the diffusion of water molecules. It is uncertain whether DWI is more useful than positron emission tomography-computed tomography (PET-CT) for distinguishing benign from malignant mediastinal tumors and mass lesions. Materials and Methods: Sixteen malignant mediastinal tumors (thymomas 7, thymic cancers 3, malignant lymphomas 3, malignant germ cell tumors 2, and thymic carcinoid 1) and 12 benign mediastinal tumors or mass lesions were assessed in this study. DWI and PET-CT were performed before biopsy or surgery. Results: The apparent diffusion coefficient (ADC) value ($1.51{\pm}0.46{\times}10^{-3}mm^2/sec$) of malignant mediastinal tumors was significantly lower than that ($2.96{\pm}0.86{\times}10^{-3}mm^2/sec$) of benign mediastinal tumors and mass lesions (P<0.0001). Maximum standardized uptake value (SUVmax) ($11.30{\pm}11.22$) of malignant mediastinal tumors was significantly higher than that ($2.53{\pm}3.92$) of benign mediastinal tumors and mass lesions (P=0.0159). Using the optimal cutoff value (OCV) $2.21{\times}10^{-3}mm^2/sec$ for ADC and 2.93 for SUVmax, the sensitivity (100%) by DWI was not significantly higher than that (93.8%) by PET-CT for malignant mediastinal tumors. The specificity (83.3%) by DWI was not significantly higher than that (66.7%) for benign mediastinal tumors and mass lesions. The accuracy (92.9%) by DWI was not significantly higher than that (82.1%) by PET-CT for mediastinal tumors and mass lesions. Conclusions: There was no significant difference between diagnostic capability of DWI and that of PET-CT for distinguishing mediastinal tumors and mass lesions. DWI is useful in distinguishing benign from malignant mediastinal tumors and mass lesions.

Preoperative Prediction of Ductal Carcinoma in situ Underestimation of the Breast using Dynamic Contrast Enhanced and Diffusion-weighted Imaging (역동적 유방 자기공명 영상 및 확산 강조영상을 이용한 관상피내암종 저평가 수술전 예측)

  • Park, Mina;Kim, Eun-Kyung;Kim, Min Jung;Moon, Hee Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.101-109
    • /
    • 2013
  • Objective: To investigate roles of dynamic contrast enhanced magnetic resonance (DCE MR) and diffusion-weighted (DW) imaging in preoperative prediction of underestimation of ductal carcinoma in situ (DCIS) ${\geq}2cm$ on US guided core needle biopsy. Materials and Methods: Twenty two patients with DCIS on US-guided 14 gauge core needle biopsy were included. Patients were divided into a group with and without DCIS underestimation based on histopathology. MR images including DCE and DW imaging were obtained with a 3.0-T MR. The lesion type (mass or non-mass), enhancement pattern, peak enhancement, and apparent diffusion coefficient (ADC) values of proven malignant masses were generated using software of CADstream and compared between two groups using Fisher's exact test and Mann Whitney test. Results: Eight patients were in the group with underestimation and 14 patients were in the group without underestimation. The lesion type and enhancement pattern were not different between two groups (P values = 1.000 and 0.613, respectively). The median peak enhancement of lesions with underestimation was 159.5%, higher than 133.5% of those without underestimation, but not significant (P value = 0.413). The median ADC value of lesions with underestimation was $1.26{\times}10^{-3}mm^2/sec$, substantially lower than $1.35{\times}10^{-3}mm^2/sec$ of those without underestimation (P value = 0.094). Conclusion: ADC values had the potential to preoperatively predict DCIS underestimation on US-guided core needle biopsy, although a large prospective series study should be conducted to confirm these results.

Imaging Findings of Renal Cell Carcinoma Associated with Xp11.2 Translocation/TFE3 Gene Fusion in a 4-Year-Old Male: Case Report and Review of Literature (4세 남아에서 발견된 Xp11.2 염색체 재배열/TFE3 유전자 융합 연관 신세포 암의 영상 소견: 증례보고 및 문헌고찰)

  • Kim, Hyun Gi;Lee, Mi-Jung;Lee, Sarah;Kim, Myung-Joon;Hong, Chang Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.1
    • /
    • pp.41-46
    • /
    • 2013
  • We represent a pathologically proven case of a four-year-old male patient with renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusion, which is rare but more frequent in children or young adults. Computed tomography showed about 2.5 cm size ill-defined mass in the right kidney. The mass was hyperechoic on ultrasound. Magnetic resonance imaging demonstrated a mass with capsular enhancement and diffusion restriction. We present a case of Xp11.2 renal cell carcinoma and provide review of the literature.

Diagnostic Yield of Diffusion-Weighted Brain Magnetic Resonance Imaging in Patients with Transient Global Amnesia: A Systematic Review and Meta-Analysis

  • Su Jin Lim;Minjae Kim;Chong Hyun Suh;Sang Yeong Kim;Woo Hyun Shim;Sang Joon Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.10
    • /
    • pp.1680-1689
    • /
    • 2021
  • Objective: To investigate the diagnostic yield of diffusion-weighted imaging (DWI) in patients with transient global amnesia (TGA) and identify significant parameters affecting diagnostic yield. Materials and Methods: A systematic literature search of the MEDLINE and EMBASE databases was conducted to identify studies that assessed the diagnostic yield of DWI in patients with TGA. The pooled diagnostic yield of DWI in patients with TGA was calculated using the DerSimonian-Laird random-effects model. Subgroup analyses were also performed of slice thickness, magnetic field strength, and interval between symptom onset and DWI. Results: Twenty-two original articles (1732 patients) were included. The pooled incidence of right, left, and bilateral hippocampal lesions was 37% (95% confidence interval [CI], 30-44%), 42% (95% CI, 39-46%), and 25% (95% CI, 20-30%) of all lesions, respectively. The pooled diagnostic yield of DWI in patients with TGA was 39% (95% CI, 27-52%). The Higgins I2 statistic showed significant heterogeneity (I2 = 95%). DWI with a slice thickness ≤ 3 mm showed a higher diagnostic yield than DWI with a slice thickness > 3 mm (pooled diagnostic yield: 63% [95% CI, 53-72%] vs. 26% [95% CI, 16-40%], p < 0.01). DWI performed at an interval between 24 and 96 hours after symptom onset showed a higher diagnostic yield (68% [95% CI, 57-78%], p < 0.01) than DWI performed within 24 hours (16% [95% CI, 7-34%]) or later than 96 hours (15% [95% CI, 8-26%]). There was no difference in the diagnostic yield between DWI performed using 3T vs. 1.5T (pooled diagnostic yield, 31% [95% CI, 25-38%] vs. 24% [95% CI, 14-37%], p = 0.31). Conclusion: The pooled diagnostic yield of DWI in TGA patients was 39%. DWI obtained with a slice thickness ≤ 3 mm or an interval between symptom onset and DWI of > 24 to 96 hours could increase the diagnostic yield.

The Role of $^{18}F$-Fluorodeoxyglucose Positron Emission Tomography in the Treatment of Brain Abscess

  • Park, Seong-Hyun;Lee, Sang-Woo;Kang, Dong-Hun;Hwang, Jeong-Hyun;Sung, Joo-Kyung;Hwang, Sung-Kyoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.5
    • /
    • pp.278-283
    • /
    • 2011
  • Objective : The purpose of this study was to evaluate whether $^{18}F$-fluorodeoxyglucose positron emission tomography (FOG-PET) can be used to assess the therapeutic response of brain abscess. Methods : A study was conducted on 10 consecutive patients with brain abscess, Magnetic resonance imaging (MRI) with diffuse-weighted imaging (DWI) was performed at 3 and 6 weeks after surgical treatment and intravenous antibiotics therapy and FOG-PET at 6 weeks after treatment. The extent of the abscess, signal changes on MRI, and FOG-PET standardized uptake values were analyzed and correlated with the response to therapy. Results : Aspiration or craniotomy with excision of the abscess followed by intravenous antibiotics for 6-8 weeks resulted in good recovery with no recurrence. In 10 patients, two had low signal intensity on the DWI; one had no uptake on FOG-PET imaging after 6 weeks antibiotics and discontinued intravenous treatment, but the other patient had diffuse, increased uptake on FOG-PET imaging after 6 weeks antibiotics and underwent an additional 2 weeks of intravenous antibiotics. The remaining eight patients had high signals on the DWI. Four had no uptake on FOG-PET imaging and the treatment period varied from 6 to 8 weeks (mean, 6.75 weeks). Among the other four patients, FOG was accumulated in a diffuse or local area corresponding to a high signal area within the DWI and 2 weeks of intravenous antibiotics was added. Conclusion : MRI plus FOG-PET improved the accuracy of assessing therapeutic responses to antibiotics treatment of brain abscess and aided in optimizing therapy.

Analysis of Magnetic Resonance Signals from Diffusion Weighted Imaging using Compressed Sensitivity Encoding Technique (압축감도 부호화를 사용한 확산강조영상에서의 자기공명신호 분석)

  • Jang, ji-sung;Choi, kwan-woo;Jeong, mi-ae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2019.05a
    • /
    • pp.231-232
    • /
    • 2019
  • 최근 압축감도 부호화라는 새로운 기술의 개발로 인하여 기존보다 더 빠른 검사시간에 자기공명영상 검사가 가능하게 되었다. 감도 부호화를 이용한 터보 스핀 에코 확산강조 자기공명영상과 비교하였을 때, 압축감도 부호화를 사용한 확산강조영상에서 영상평가와 자기공명 신호 분석을 통해 적절한 영상품질을 유지하면서, 검사시간을 줄 일수 있어 확산강조영상에서에 유용하게 사용되리라 사료된다.

  • PDF

Diffus ion-Weighted MR Imaging of Spinal Cord Infarction (척수경색의 확산강조자기공명영상)

  • 김윤정;서정진;임남열;정태웅;김윤현;박진균;정광우;강형근
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.166-172
    • /
    • 2002
  • Purpose : To evaluate the usefulness of diffusion-weighted imaging(DWI) and quantitative apparent diffusion coefficient (ADC) maps in the patients with spinal cord infarction. Materials and methods : We studied 6 patients presented symptoms with spinal cord infarction, retrospectively (3 men and 3 women). We obtained multi-shot echo planar-based, DWI using 1.5T MR scanner at 5.4 mean days after the onset of ischemic symptoms. In six patients, signal intensity was acquired at conventional b value $1000s/\textrm{mm}^2$). The ADC value for the normal spinal cord and for infarcted lesions was measured from the trace ADC maps by using regions of interest positioned over the spinal cord. We analyzed signal intensity of lesion on MRI and DWI, and compared with ADC values in infarcted lesions and normal site. Results : T1-weighted MR image showed isosignal intensity in four of six patients and low signal intensity in two of six. T2-weighted MR image demonstrated high signal intensity in all of six. All DWI were considered to be diagnostic. All of six depicted a bright signal intensity on DWI. ADC values of infarcted lesion were measured lower than that of normal spinal cord on ADC map. The differences in ADC values between infarcted and normal spinal cord were significantly different (p<0.05). Conclusion : It is possible to obtain DWI and ADC map of the spinal cord and DWI may be useful in the early diagnosis and localization of lesion site in patients with spinal cord infarction.

  • PDF

MR Neurography: Current Several Issues for Novice Radiologists (자기공명영상 신경조영술: 경험이 적은 영상의학과 의사가 이해해야 할 몇 가지 쟁점들)

  • Dong-ho Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.81-100
    • /
    • 2020
  • Magnetic resonance neurography (MRN) has been increasingly used in recent years for the assessment of peripheral neuropathies. Fat suppression T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) have typically been used to provide high contrast MRN. Isotropic 3-dimensional (3D) sequences with fast spin echo, post-processing imaging techniques, and fast imaging methods, among others, allow good visualization of peripheral nerves that have a small diameter, complex anatomy, and oblique course within a reasonable scan time. However, there are still several issues when performing high contrast and high resolution MRN including standard sequence; fat saturation techniques; balance between resolution, field of view, and slice thickness; post-processing techniques; 2D vs. 3D image acquisition; different T2 contrasts between proximal and distal nerves; high T2 signal intensity of adjacent veins or joint fluid; geometric distortion; and appropriate p-values on DWI. The proper understanding of these issues will help novice radiologists evaluate peripheral neuropathies using MRN.

Feasibility of Simultaneous Multislice Acceleration Technique in Diffusion-Weighted Magnetic Resonance Imaging of the Rectum

  • Jae Hyon Park;Nieun Seo;Joon Seok Lim;Jongmoon Hahm;Myeong-Jin Kim
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.77-87
    • /
    • 2020
  • Objective: To assess the feasibility of simultaneous multislice-accelerated diffusion-weighted imaging (SMS-DWI) of the rectum in comparison with conventional DWI (C-DWI) in rectal cancer patients. Materials and Methods: This study included 65 patients with initially-diagnosed rectal cancer. All patients underwent C-DWI and SMS-DWI with acceleration factors of 2 and 3 (SMS2-DWI and SMS3-DWI, respectively) using a 3T scanner. Acquisition times of the three DWI sequences were measured. Image quality in the three DWI sequences was reviewed by two independent radiologists using a 4-point Likert scale and subsequently compared using the Friedman test. Apparent diffusion coefficient (ADC) values for rectal cancer and the normal rectal wall were compared among the three sequences using repeated measures analysis of variance. Results: Acquisition times using C-DWI, SMS2-DWI, and SMS3-DWI were 173 seconds, 107 seconds, (38.2% shorter than C-DWI), and 77 seconds (55.5% shorter than C-DWI), respectively. For all image quality parameters other than distortion (margin sharpness, artifact, lesion conspicuity, and overall image quality), C-DWI and SMS2-DWI yielded better results than did SMS3-DWI (Ps < 0.001), with no significant differences observed between C-DWI and SMS2-DWI (Ps ≥ 0.054). ADC values of rectal cancer (p = 0.943) and normal rectal wall (p = 0.360) were not significantly different among C-DWI, SMS2-DWI, and SMS3-DWI. Conclusion: SMS-DWI using an acceleration factor of 2 is feasible for rectal MRI resulting in substantial reductions in acquisition time while maintaining diagnostic image quality and similar ADC values to those of C-DWI.

Comparison of Monoexponential, Biexponential, Stretched-Exponential, and Kurtosis Models of Diffusion-Weighted Imaging in Differentiation of Renal Solid Masses

  • Jianjian Zhang;Shiteng Suo;Guiqin Liu;Shan Zhang;Zizhou Zhao;Jianrong Xu;Guangyu Wu
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.791-800
    • /
    • 2019
  • Objective: To compare various models of diffusion-weighted imaging including monoexponential apparent diffusion coefficient (ADC), biexponential (fast diffusion coefficient [Df], slow diffusion coefficient [Ds], and fraction of fast diffusion), stretched-exponential (distributed diffusion coefficient and anomalous exponent term [α]), and kurtosis (mean diffusivity and mean kurtosis [MK]) models in the differentiation of renal solid masses. Materials and Methods: A total of 81 patients (56 men and 25 women; mean age, 57 years; age range, 30-69 years) with 18 benign and 63 malignant lesions were imaged using 3T diffusion-weighted MRI. Diffusion model selection was investigated in each lesion using the Akaike information criteria. Mann-Whitney U test and receiver operating characteristic (ROC) analysis were used for statistical evaluations. Results: Goodness-of-fit analysis showed that the stretched-exponential model had the highest voxel percentages in benign and malignant lesions (90.7% and 51.4%, respectively). ADC, Ds, and MK showed significant differences between benign and malignant lesions (p < 0.05) and between low- and high-grade clear cell renal cell carcinoma (ccRCC) (p < 0.05). α was significantly lower in the benign group than in the malignant group (p < 0.05). All diffusion measures showed significant differences between ccRCC and non-ccRCC (p < 0.05) except Df and α (p = 0.143 and 0.112, respectively). α showed the highest diagnostic accuracy in differentiating benign and malignant lesions with an area under the ROC curve of 0.923, but none of the parameters from these advanced models revealed significantly better performance over ADC in discriminating subtypes or grades of renal cell carcinoma (RCC) (p > 0.05). Conclusion: Compared with conventional diffusion parameters, α may provide additional information for differentiating benign and malignant renal masses, while ADC remains the most valuable parameter for differentiation of RCC subtypes and for ccRCC grading.