• Title/Summary/Keyword: Diffusion imaging

Search Result 443, Processing Time 0.028 seconds

Engraftment of Human Mesenchymal Stem Cells in a Rat Photothrombotic Cerebral Infarction Model : Comparison of Intra-Arterial and Intravenous Infusion Using MRI and Histological Analysis

  • Byun, Jun Soo;Kwak, Byung Kook;Kim, Jae Kyun;Jung, Jisung;Ha, Bon Chul;Park, Serah
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.6
    • /
    • pp.467-476
    • /
    • 2013
  • Objective : This study aimed to evaluate the hypotheses that administration routes [intra-arterial (IA) vs. intravenous (IV)] affect the early stage migration of transplanted human bone marrow-derived mesenchymal stem cells (hBM-MSCs) in acute brain infarction. Methods : Male Sprague-Dawley rats (n=40) were subjected to photothrombotic infarction. Three days after photothrombotic infarction, rats were randomly allocated to one of four experimental groups [IA group : n=12, IV group : n=12, superparamagnetic iron oxide (SPIO) group : n=8, control group : n=8]. All groups were subdivided into 1, 6, 24, and 48 hours groups according to time point of sacrifice. Magnetic resonance imaging (MRI) consisting of T2 weighted image (T2WI), $T2^*$ weighted image ($T2^*WI$), susceptibility weighted image (SWI), and diffusion weighted image of rat brain were obtained prior to and at 1, 6, 24, and 48 hours post-implantation. After final MRI, rats were sacrificed and grafted cells were analyzed in brain and lung specimen using Prussian blue and immunohistochemical staining. Results : Grafted cells appeared as dark signal intensity regions at the peri-lesional zone. In IA group, dark signals in peri-lesional zone were more prominent compared with IV group. SWI showed largest dark signal followed by $T2^*WI$ and T2WI in both IA and IV groups. On Prussian blue staining, IA administration showed substantially increased migration and a large number of transplanted hBM-MSCs in the target brain than IV administration. The Prussian blue-positive cells were not detected in SPIO and control groups. Conclusion : In a rat photothrombotic model of ischemic stroke, selective IA administration of human mesenchymal stem cells is more effective than IV administration. MRI and histological analyses revealed the time course of cell migration, and the numbers and distribution of hBM-MSCs delivered into the brain.

Anatomical Brain Connectivity Map of Korean Children (한국 아동 집단의 구조 뇌연결지도)

  • Um, Min-Hee;Park, Bum-Hee;Park, Hae-Jeong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.110-122
    • /
    • 2011
  • Purpose : The purpose of this study is to establish the method generating human brain anatomical connectivity from Korean children and evaluating the network topological properties using small-world network analysis. Materials and Methods : Using diffusion tensor images (DTI) and parcellation maps of structural MRIs acquired from twelve healthy Korean children, we generated a brain structural connectivity matrix for individual. We applied one sample t-test to the connectivity maps to derive a representative anatomical connectivity for the group. By spatially normalizing the white matter bundles of participants into a template standard space, we obtained the anatomical brain network model. Network properties including clustering coefficient, characteristic path length, and global/local efficiency were also calculated. Results : We found that the structural connectivity of Korean children group preserves the small-world properties. The anatomical connectivity map obtained in this study showed that children group had higher intra-hemispheric connectivity than inter-hemispheric connectivity. We also observed that the neural connectivity of the group is high between brain stem and motorsensory areas. Conclusion : We suggested a method to examine the anatomical brain network of Korean children group. The proposed method can be used to evaluate the efficiency of anatomical brain networks in people with disease.

Impact of Time Interval between Index Event and Stenting on Periprocedural Risk in Patients with Symptomatic Carotid Stenosis

  • Han, Wonsuck;Hwang, Gyojun;Oh, Sung Han;Lee, Jong Joo;Kim, Mi Kyung;Chung, Bong Sub;Rhim, Jong Kook;Sheen, Seung Hun;Kim, Taehyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.5
    • /
    • pp.598-606
    • /
    • 2020
  • Objective : The purpose of this study was to evaluate the impact of time interval between index event and stenting on the periprocedural risk of stenting for symptomatic carotid stenosis and to determine the optimal timing of stenting. Methods : This retrospective study included 491 (322 symptomatic [65.6%] and 169 asymptomatic [34.4%]) patients undergoing carotid stenting. The symptomatic patients were categorized into Day 0-3, 4-7, 8-10, 11-14, 15-21, and >21 groups according to the time interval between index event and stenting. Periprocedural (≤30 days) risk for clinical (any neurological deterioration) and radiological (new infarction on postprocedural diffusion-weighted imaging) events of stenting in each time interval versus asymptomatic stenosis was calculated with logistic regression analysis adjusted for confounders, and provided as odds ratio (OR) and 95% confidence interval (CI). Results : Overall clinical event rate (4.3%) of stenting for symptomatic carotid stenosis was higher than that for asymptomatic stenosis (1.2%; OR, 3.979 [95% CI, 1.093-14.489]; p=0.036). Stenting in Day 0-3 (13.2%; OR, 10.997 [95% CI, 2.333-51.826]; p=0.002) and Day 4-7 (8.3%; OR, 6.775 [95% CI, 1.382-33.227]; p=0.018) was associated with high risk for clinical events. However, the clinical event rates in stenting after 7 days from index event (Day 8-10, 1.8%; Day 11-14, 2.5%; Day 15-21, 0%; Day >21, 2.9%) were not different from that in stenting for asymptomatic stenosis. Overall radiological event rate (55.6%) in symptomatic stenosis was also higher than that in asymptomatic stenosis (35.5%; OR, 2.274 [95% CI, 1.553-3.352]; p<0.001). The high risk for radiological events was maintained in all time intervals (Day 0-3 : 55.3%; OR, 2.224 [95% CI, 1.103-4.627]; p=0.026; Day 4-7 : 58.3%; OR, 2.543 [95% CI, 1.329-4.949]; p=0.005; Day 8-10 : 53.6%; OR, 2.096 [95% CI, 1.138-3.889]; p=0.018; Day 11-14 : 57.5%; OR, 2.458 [95% CI, 1.225-5.021]; p=0.012; Day 15-21 : 55.6%; OR, 2.271 [95% CI, 1.099-4.764]; p=0.028; Day >21 : 54.8%; OR, 2.203 [95% CI, 1.342-3.641]; p=0.002). Conclusion : This study showed that as stenting was delayed, the periprocedural risk for clinical events decreased. The clinical event risk was high only in stenting within 7 days and comparable with that for asymptomatic stenosis in stenting after 7 days from index event, although the radiological event risk was not affected by stenting timing. Therefore, our results suggest that delayed stenting after 7 days from symptom onset is a safe strategy for symptomatic stenosis.

Implementation about measurement of the head SAR and variable parameter according to operation control mode in brain MR study with 1.5Tesia (1.57 BRAIN MRI검사에서의 작동제어모드를 통한 두부 SAR측정과 변화인자에 관한 고찰)

  • Lee, Kyu-Su;Sim, Hyun;Moon, Ji-Hoon;Oh, Jae-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.58-60
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has become a very widely used medical procedur e. Clo.sed and open systems are typically used with static magnetic fields at or below 2 Tesla. BWhole body SAR(specific absorbsion rate) is the value of SAR averaged over the entire body of the patient over any period of 15 minutes. Head SAR is the value of SAR averaged over the head of the patient for any period of 10 minutes. SAR is a measure of the absorption of electromagnetic energy in the body' (typically in watts per kilogram (W/kg)). The normal operating mode comprises values of head SAR not higher than 3 W/kg. The second level controlled operating mode comprises values higher than 3 W/kg. Current FDA guidance limits the SAR in the whole body. including the head to a range of 1.5 to 4.0 W/kg, depending on the patient's clinical condition. SAR, limit restrictions are incorporated in all MRI systems. and domestic' s guidance limits the SAR in a part body. including the head to 3.2w/kg and less. The purpose of this study is to evaluate on change of head SAR in using MRI pulse sequence and to check if exceed 3.2(w/kg) level in domestic a part exposure through measured head SAR. 23 patient's the average head SAR of pulse sequence is that T2WI sagittal is 0.5375. T2WI axial(FSE) is 0.4817, T1WI axial(SE) is, 0.8179. FLAIR axial is 0.4580. GRE axial is 0.0077, Diffusion is 0.0824w/kg. The head SAR exposed per patient was proved 2.3845w/kg less than the international standard. Coefficient of correlation for the relations body weight and SAR or for the relations ETL(echo train length) and SAR is 1 value. Coefficient of correlation for the relations between TR(time to repeat) and SAR is -0.602 value. so SAR increased relative to weight body and ETL. But the relations between TR and SAR is negative definite.

  • PDF

Evaluation of MR-SENSE Reconstruction by Filtering Effect and Spatial Resolution of the Sensitivity Map for the Simulation-Based Linear Coil Array (선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가)

  • Lee, D.H.;Hong, C.P.;Han, B.S.;Kim, H.J.;Suh, J.J.;Kim, S.H.;Lee, C.H.;Lee, M.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.245-250
    • /
    • 2011
  • Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{\times}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.

3-D Analysis of Semiconductor Surface by Using Photoacoustic Microscopy (광음향 현미경법을 이용한 반도체 표면의 3차원적 구조 분석)

  • Lee, Eung-Joo;Choi, Ok-Lim;Lim, Jong-Tae;Kim, Ji-Woong;Choi, Joong-Gill
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.6
    • /
    • pp.553-560
    • /
    • 2004
  • In this experiment, a three dimensional structure analysis was carried out to examine the surface defects of semiconductor made artificially on known scale. It was investigated the three dimensional imaging according to the sample depth and the thermal diffusivity as well as the carrier transport properties. The thermal diffusivity measurement of the intrinsic GaAs semiconductor was also analyzed by the difference of frequency-dependence photoacoustic signals from the sample surface of different conditions. Thermal properties such as thermal diffusion length or thermal diffusivity of the Si wafer with and without defects on the surface were obtained by interpreting the frequency dependence of the PA signals. As a result, the photoacoustic signal is found to have the dependency on the shape and depth of the defects so that their structure of the defects can be analyzed. This method demonstrates the possibility of the application to the detection of the defects, cracks, and shortage of circuits on surface or sub-surface of the semiconductors and ceramic materials as a nondestructive testing(NDT) and a nondestructive evaluation(NDE) technique.

Comparison of Fornix and Stria Terminalis Connectivity among First-Episode Schizophrenia, Chronic Schizophrenia and Healthy Controls (초발 조현병, 만성 조현병과 건강 대조군의 뇌활과 분계섬유줄 연결성 비교)

  • Lee, Arira;Yun, Mirim;Yook, Ki Hwan;Choi, Tai Kiu;Lee, Kang Soo;Bang, Minji;Lee, Sang-Hyuk
    • Korean Journal of Biological Psychiatry
    • /
    • v.26 no.1
    • /
    • pp.8-13
    • /
    • 2019
  • Objectives Disrupted integrities of the fornix and stria terminalis have been suggested in schizophrenia. However, very few studies have focused on the fornix and stria terminalis comparing first-episode schizophrenia (FESZ), chronic schizophrenia (CS), and healthy controls (HCs) with the application of diffusion-tensor imaging (DTI) technique. The objective of this study is to compare the connectivity of the fornix and stria terminalis among FESZ, CS, and HCs. Methods We included the 44 FESZ patients, 39 CS patients and 20 HCs in this study. Voxel-wise statistical analysis of the fractional anisotropy (FA) data was performed using Tract-Based Spatial Statistics to analyze the connectivity of fornix and stria terminalis. In addition, the Scale for the Assessment of Positive Symptoms (SAPS) and the Scale for the Assessment of Negative Symptoms (SANS) were used to evaluate clinical symptom severities. Results There were no significant differences between the FESZ, CS, and HCs in age, sex, education years. The SAPS and SANS scores of the schizophrenia groups showed no significant differences. FA values of the right fornix cres/stria terminalis in the CS group were significantly lower than those in FESZ and HCs. There were no significant differences of FA values of the right fornix cres/stria terminalis between the FESZ and the HCs. Pearson correlation analyses revealed that significant correlation between FA values of the right fornix cres/stria terminalies of the the FESZ group and positive, negative symptom scales, and FA values of the right fornix cres/stria terminalis of the CS group and negative symptom scales. Conclusions This study shows that FA values of the fornix and stria terminalis in the CS were lower than in the FESZ and the HCs. These results suggest that the fornix and stria terminalis can play a role in pathophysiology of schizophrenia. Thus current study can broaden our understanding of the pathophysiology of schizophrenia.

MRI Findings of COVID-19 Associated Acute Necrotizing Encephalopathy in Two Pediatric Patients: Case Report and Literature Review (소아에서 발생한 COVID-19 연관 급성 괴사성 뇌병증의 MRI 소견: 2건의 증례 보고 및 문헌 고찰)

  • Yoon Yeong Choi;Ha Young Lee;Myung Kwan Lim;Young Hye Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.682-690
    • /
    • 2024
  • Acute necrotizing encephalopathy (ANE) is a rare immune-mediated complication of a viral infection commonly involving the bilateral thalamus and has been reported mainly in children. Here, we describe the MRI findings of coronavirus disease 2019 (COVID-19)-associated ANE in two pediatric patients, including a 7-year-old girl with fever and mental change, and a 6-year-old girl with fever and generalized seizures. Brain MRI revealed symmetrical T2 fluid attenuated inversion recovery high-signal intensity lesions in the bilateral thalamus with central hemorrhage. In one patient, the thalamic lesions showed a tri-laminar pattern on the apparent diffusion coefficient map. This report emphasizes the importance of creating awareness regarding these findings in patients with COVID-19, particularly in children with severe neurological symptoms. Furthermore, it provides a literature review of several documented cases of COVID-19 presenting with bilateral thalamic hemorrhagic necrosis, suggesting a diagnosis of ANE.

Usefulness of MRI Scoring System for Differential Diagnosis between Xanthogranulomatous Cholecystitis and Wall-Thickening Type Gallbladder Cancer (황색육아종성 담낭염과 벽비후형 담낭암의 감별진단을 위한 자기공명영상 점수체계의 유용성)

  • Soul Han;Young Hwan Lee;Youe Ree Kim;Eun Gyu Soh
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.147-160
    • /
    • 2024
  • Purpose To define an MRI scoring system for differentiating xanthogranulomatous cholecystitis (XGC) from wall-thickening type gallbladder cancer (GBC) and compare the diagnostic performance of the scoring system with the visual assessment of radiologists. Materials and Methods We retrospectively analyzed 23 and 35 patients who underwent abdominal MRI and were pathologically diagnosed with XGC and wall-thickening-type GBC after surgery, respectively. Three radiologists reviewed all MRI findings. We defined a scoring system using these MRI findings for differentiating XGC from wall-thickening type GBC and compared the area under the curve (AUC) of the scoring system with the visual assessment of radiologists. Results Nine MRI findings showed significant differences in differentiating the two diseases: diffuse gallbladder wall thickening (p < 0.001), mucosal uniformity (p = 0.002), intramural T2-high signal intensity (p < 0.001), mucosal retraction (p = 0.016), gallbladder stones (p < 0.001), T1-intermediate to high-signal intensity (p = 0.033), diffusion restriction (p = 0.005), enhancement pattern (p < 0.001), and phase of peak enhancement (p = 0.008). The MRI scoring system showed excellent diagnostic performance with an AUC of 0.972, which was significantly higher than the visual assessment of the reviewers. Conclusion The MRI scoring system showed better diagnostic performance than the visual assessment of radiologists to differentiate XGC from wall-thickening-type GBC.

Image Comparison of Heavily T2 FLAIR and DWI Method in Brain Magnetic Resonance Image (뇌 자기공명영상에서 Heavily T2 FLAIR와 DWI 기법의 영상비교)

  • EunHoe Goo
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.397-403
    • /
    • 2023
  • The purpose of this study is to obtain brain MRI images through Heavenly T2 FLAIR and DWI techniques to find out strengths and weaknesses of each image. Data were analyzed on 13 normal people and 17 brain tumor patients. Philips Ingenia 3.0TCX was used as the equipment used for the inspection, and 32 Channel Head Coil was used to acquire data. Using Image J and Infinity PACS Data, 3mm2 of gray matter, white matter, cerebellum, basal ganglia, and tumor areas were set and measured. Quantitative analysis measured SNR and CNR as an analysis method, and qualitative analysis evaluated overall image quality, lesion conspicuity, image distortion, susceptibility artifact and ghost artifact on a 5-point scale. The statistical significance of data analysis was that Wilcox-on Signed Rank Test and Paired t-test were executed, and the statistical program used was SPSS ver.22.0 and the p value was less than 0.05. In quantitative analysis, the SNR of gray matter, white matter, cerebellum, basal ganglia, and tumor of Heavily T2 FLAIR is 41.45±0.13, 40.52±0.45, 41.44±0.51, 40.96±0.09, 35.28±0.46 and the CNR is 15.24±0.13, 16.75±0.23, 16.28±0.41, 15.83±0.17, 16.63±0.51. In DWI, SNR is 32.58±0.22, 36.75±0.17, 30.21±0.19, 35.83±0.11, 43.29±0.08, and CNR is 13.14±0.63, 14.21±0.31, 12.95±0.32, 11.73±0.09, 17.56±0.52. In normal tissues, Heavenly T2 FLAIR obtained high results, but in disease evaluation, high results were obtained at DWI, b=1000 (p<0.05). In addition, in the qualitative analysis, overall image quality, lesion conspicuity, image distortion, susceptibility artifact and ghost artifact aspects of the Heavily T2 FLAIR were evaluated, and 3.75±0.28, 2.29±0.24, 3.86±0.23, 4.08±0.21, 3.79±0.22 values were found, respectively, and 2.53±0.39, 4.13±0.29, 1.90±0.20, 1.81±0.21, 1.52±0.45 in DWI. As a result of qualitative analysis, overall image quality, image distortion, susceptibility artifact and ghost artifact were rated higher than DWI. However, DWI was evaluated higher in lesion conspicuity (p<0.05). In normal tissues, the level of Heavenly T2 FLAIR was higher, but the DWI technique was higher in the evaluation of the disease (tumor). The two results were necessary techniques depending on the normal site and the location of the disease. In conclusion, statistically significant results were obtained from the two techniques. In quantitative and qualitative analysis, the two techniques had advantages and disadvantages, and in normal and disease evaluation, the two techniques produced useful results. These results are believed to be educational data for clinical basic evaluation and MRI in the future.