• Title/Summary/Keyword: Diffusers

Search Result 159, Processing Time 0.051 seconds

An Experimental Study on the Rotating Stall in Vaneless Diffuser of Centrifugal Blower with Radial Type Impeller (반경류형 회전차를 가진 원심송풍기의 깃이 없는 디퓨저 내의 선회실속에 관한 실험적 연구)

  • Kim, Jin Hyoung;Cho, Kang Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.9
    • /
    • pp.1247-1254
    • /
    • 1998
  • The vaneless diffusers are widely used in industrial centrifugal compressors which are required to operate within a wide flow range. When very high pressure gases are handled by centrifugal compressor. rotating stall is a serious problem because of the occurance of large aerodynamic exciting forces. Rotating stall mostly often occurs in the impellers but it can occur in vaneless diffusers as well. In this experimental study, the rotating stall in vaneless diffuser with radial type centrifugal impeller was measured by changing the flow rate with I-type, X-type hotwire. As the result, it was cleared which type of rotating stall of the impeller stall would occur and how many stall cells would appear relating with the flow rate. As the flow rate reduced, the propagation speed of rotating stall was reduced. But the stall cell number unchanged with respect to the flow rate.

Topology Optimization of an Acoustic Diffuser Considering Reflected Sound Field (반사 음장을 고려한 음향 확산 구조의 위상 최적 설계)

  • Yang, Jieun;Lee, Joong Seok;Kim, Yoon Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.11
    • /
    • pp.973-981
    • /
    • 2013
  • The main role of an acoustic diffuser is to diffuse reflected sound field spatially. Since the pioneering work of Schroeder, there have been investigations to improve its performance by using shape/sizing optimization methods. In this paper, a gradient-based topology optimization algorithm is newly presented to find the optimal distribution of reflecting materials for maximizing diffuser performance. Time-harmonic acoustic analysis in a two-dimensional acoustic domain is carried out where the domain is discretized by finite elements. Perfectly matched layers are placed to surround the domain to simulate non-reflecting boundary conditions. Design variables are assigned to each element of which material properties are interpolated between those of air and those of a rigid body. An approach to extract the reflected field from the total acoustic field is employed. To validate the effectiveness of the proposed method, design problems are solved at different frequencies. The performance of the optimized diffusers obtained by the proposed method is compared against that of the conventional Schroeder diffusers.

Investigation of Off-Design Performance of Vaned Diffusers in Centrifugal Compressors - Part I : A Channel-Wedge Diffuser - (원심압축기용 베인디퓨져의 탈설계점 성능연구 - 제1부 : 채널디퓨져 -)

  • Oh, JongSik;Hyun, YongIk
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.83-90
    • /
    • 2001
  • Experimental and numerical investigations of the off·design performance of a simple channel-wedge diffuser in a small centrifugal compressor are presented. Surge and choke conditions as well as design point are considered using somewhat limited range of experimental data and also supplementary 3D CFD results. Some critical meanline design parameters' behavior is investigated numerically, to render the basis for improved modelings in the meanline performance prediction.

  • PDF

Aerodynamic Design Program for Centrifugal/Mixed-flow Compressors - Part I : Meanline Design and Performance Prediction - (원심/사류압축기의 공력설계 프로그램 개발 - 제1부 : 평균유선 설계/성능해석 -)

  • Oh, Jong-Sik
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.457-463
    • /
    • 2003
  • A general program of meanline design and/or performance prediction for centrifugal/mixed-flow compressors is successfully commercialized using various empirical loss models. 4 types of diffusers, 3 types of exit elements, shrouded/unshrouded impellers and real gas option are included in the program capabilities. Total 16 cases of benchmark test results proved its reliability to be effectively utilized in the development processes.

  • PDF

Expansion of Test Frequency Band and Improvements of Field Uniformity in a Reverberation Chamber by Using Dual-Band Diffusers (이중 대역 확산기를 이용한 전자파 잔향실 시험 주파수 대역 확장 및 전자기장 균일도 향상에 관한 연구)

  • Lim Wook-Chae;Rhee Joong-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.1 s.104
    • /
    • pp.74-80
    • /
    • 2006
  • This paper presents the characteristics of electromagnetic field uniformity in a reverberation chamber that can be used alternatively for the analysis, test and evaluation of electromagnetic interference and immunity. The dual-band diffuser, which can be used at two different frequency bands in a reverberation chamber, is applied, and it is made of two different single-band Schroeder's Quadratic Residue Diffusers. The FDTD method is used to analyze the field characteristics. Compared with single-band diffuser, the dual-band diffuser shows the improvement in not only expansion of test frequency band but also in characteristics of the field uniformity, polarity, power efficiency, and tolerance. Therefore, the reverberation chamber with the dual-band diffuser is a better facility, for the analysis and measurement of electromagnetic interference and immunity, than the reverberation chamber with a single-band diffuser.

A Study on The Performance of Ventilation and Maintaining Thermal Environment for a Combined Type Diffuser (급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.232-241
    • /
    • 2016
  • Installing a ventilator for an apartment house composed of over 100 dwelling units was mandated in 2006 to improve indoor air quality. In the case of mechanical ventilators, the air change rate is kept stable, however 68% of dwellers do not operate their ventilator because of an increased electrical bill and noise. In the case of natural ventilators, the former problems are settled, but there are concerns about cold draught and an increase of heating/cooling cost. Authors are developing a heat recovery type natural ventilator which is a natural ventilator equipped with total heat recovery element, and it is expected that those problems of mechanical ventilator and natural ventilator are resolved by this. The combined type diffuser of this study is an under developed fit to the heat recovery type natural ventilator above. There are no standards to evaluate the performance for this type of diffuser. Due to this issue this study investigated the performance of the ventilation and maintained a thermal environment for the combined type diffuser by comparing it with existing diffusers. The results revealed that the performances of the combined type of diffusers showed different features from the existing ones, and was estimated to be high enough in the performances above.

ADPI Characteristics of Line Diffuser in a Room with Perimetric Heating Load (측벽 부하가 존재하는 공간에 설치된 라인 디퓨져의 ADPI 특성에 관한 연구)

  • Cho Young-Jin;Kang Seok-Youn;Moon Jong -Sun;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1204-1211
    • /
    • 2004
  • It is difficult to apply a conventional selection guide for diffusers when the diffuser is installed in a perimeter zone, because the air diffusion performance index (ADPI) vs. throw/length (T/L) ratio curve listed in conventional guide does not consider the perimetric heating load through the walls. The objective of this study is to evaluate the effect of the perimetric heating load on the ADPI and propose a selection guide for a proper line diffuser when perimetric heating load exists. The velocity and temperature distributions and the ADPI values are obtained numerically with various heat load ratios and air flow rates. The velocity and temperature distributions and the ADPI values are analyzed by CFD in case of various heat load ratios and air flow rates. Also, ADPI was calculated by those results. The ADPI values by numerical results are compared with an existing experimental data to verify the method for the evaluation of ADPI proposed in a present study. In case of a line diffuser installed at the high side wall, the ADPI decreases according to the increases of the flow rate on every heat load ratio of the present study except 0.75. The ADPI vs. T/L ratio curves have been proposed for the heat load ratios of 0.25, 0.5, 0.75 to guarantee the comport thermal environment when diffusers are installed in perimeter zone.