• Title/Summary/Keyword: Differential operation

Search Result 454, Processing Time 0.036 seconds

The Research on Location Monitoring Device using Exploratory Spatial Data Analysis (공간종속성 분석기반 모니터링 장비위치결정 기법)

  • Kim, Joo Hwan;Nam, Doohee;Jung, Jum Lae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.4
    • /
    • pp.124-137
    • /
    • 2018
  • The main purpose of this study is to find the hotspots of crimes that occur frequently in the space and to derive the appropriate CCTV installation location. One of the characteristics of crime is clustered around past occurrence area, and these crimes are strongly correlated. It is also possible to find the cause of the clusters and the variables that affect the crime through the history of the crime. In addition to the traditional OLS model, spatial differential model including spatial autocorrelation and spatial error model were used to select the variables influencing the five major crime rate, the theft rate and the foreign resident rate. The variables affecting the Five major crimes were positive (+) sign for the welfare and the rate of the bar cluster rate, and negative (-) for the street density. The CCTV area occupies 46% of the hotspots based on the overlapping of the areas where the elderly people are crowded, the bar cluster, many multicultural families, and the areas with low density of street lamps. It turned out. Taking into account the current CCTV operation, the total number of new cases to cover the risk point was 89.

Design of a 2.5V 300MHz 80dB CMOS VGA Using a New Variable Degeneration Resistor (새로운 가변 Degeneration 저항을 사용한 2.5V 300MHz 80dB CMOS VGA 설계)

  • 권덕기;문요섭;김거성;박종태;유종근
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.9
    • /
    • pp.673-684
    • /
    • 2003
  • A degenerated differential pair has been widely used as a standard topology for digitally programmable CMOS VGAs. A variable degeneration resistor has been implemented using a resistor string or R-2R ladder with MOSFET switches. However, in the VGAs using these conventional methods, low-voltage and high-speed operation is very hard to achieve due to the dc voltage drop over the degeneration resistor. To overcome this problem a new variable degeneration resistor is proposed where the dc voltage drop is almost removed. Using the proposed gain control scheme, a low-voltage and high-speed CMOS VGA is designed. HSPICE simulation results using a 0.25${\mu}{\textrm}{m}$ CMOS process parameters show that the designed VGA provides a 3dB bandwidth of 360MHz and a 80dB gain control range in 2dB step. Gain errors are less than 0.4dB at 200MHz and less than l.4dB at 300MHz. The designed circuit consumes 10.8mA from a 2.5V supply and its die area is 1190${\mu}{\textrm}{m}$${\times}$360${\mu}{\textrm}{m}$.

A Study on Electrical Characteristics for Coil Winding Number Changes of Eddy Current Bobbin Coil for Steam Generator Tubes in NPPs (원전 증기발생기 전열관 와전류검사용 보빈코일의 권선 수 변화에 대한 전기적 특성 연구)

  • Nam, Min-Woo;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.64-70
    • /
    • 2012
  • Two kinds of eddy current probes are mainly used to perform the steam generator tube integrity assesment in NPPs. The first one is the bobbin probe using for inspection of volumetric defect like a fretting wear. The second one is the rotating probe using for inspection of non-volumetric defect like a crack. The eddy current probe is one of the essential components which consist of the whole eddy current examination system, and provides a decisive data for the tube integrity in accordance with acceptance criteria described in specific procedures. The design of ECT probe is especially important to improve examination results because the quality of acquired ECT data is depended on the probe design characteristics, such as coil geometry, electrical properties, operation frequency. In this study, it is analyzed that the coil winding number of differential bobbin probe affects the electrical properties of the probe. Eddy current bobbin probes for the steam generator tubes in NPPs are designed and fabricated according to the results. Experiment shows that the change in coil winding number has much effects on the optimum inspection frequency determined by the tube geometry and material. Therefore, the coil winding number in bobbin probe is very important in the probe design. In this study, a basis of the coil winding number for the eddy current bobbin probe design for steam generator tubes in NPPs is established.

A New Variable Degeneration Resistor for Digitally Programmable CMOS VGA (디지털 방식의 이득조절 기능을 갖는 CMOS VGA를 위한 새로운 가변 축퇴 저항)

  • Kwon, Duck-Ki;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.43-55
    • /
    • 2003
  • A degenerated differential pair has been widely used as a standard topology for digitally programmable CMOS VGAs. A variable degeneration resistor has been implemented using a resistor string or R-2R ladder with MOSFET switches. However, in the VGAs using these conventional methods, low-voltage and high-speed operation is very hard to achieve due to the dc voltage drop over the degeneration resistor. To overcome the problem a new variable degeneration resistor is proposed where the dc voltage drop is almost removed. The proposed gain control scheme makes it easy to implement a low-voltage and high-speed VGA. This paper describes the problems existed in conventional methods, the principle and advantages of the proposed scheme, and their performance comparison in detail. A CMOS VGA cell is designed using the proposed degeneration resistor. The 3dB bandwidths are greater than 650㎒ and the gain errors are less than 0.3dB in a gain control range from -12dB to +12dB in 6dB steps. It consumes 3.1㎃ from a 2.5V supply voltage.

  • PDF

Acute Type A Aortic Dissection Mimicking Penetrating Atherosclerotic Ulcer (침투성 동맥경화성 궤양과 흡사한 급성 A형 대동맥 박리증 -1l례 보고 -)

  • Choi, jae-Sung;Kwak, Jae-Gun;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.36 no.1
    • /
    • pp.30-34
    • /
    • 2003
  • As classical acute aortic dissection, atherosclerotic penetrating ulcers and intramural hematoma have different pathophysiology and natural history, treatment strategy should be different and, therefore, accurate differential diagnosis is necessary. However, these three aortic diseases may be indistinguishable by clinical observation and even by various diagnostic modalities such as cardiac echocardiography, CT and MRI. The patients was a 71-year-old female with chief complaints of anterior chest pain, nausea and vomiting which occurred suddenly 3 days before admission. CT angiographic with 3 dimensional reconstruction shows intramural hematoma in ascending aorta, aortic arch, descending thoracic aorta and right brachiocephalic trunk, heompericardium, and blood in mediastinum and both pleural cavities. The CT angiographic finding of focal out-bulging in the ascending thoracic aorta was diagnosed as penetrating atherosclerotic ulcer. The patient underwent emergency operation under a preoperative diagnosis of penetrating atherosclerotic ulcer with a sign of aortic rupture. In the intraoperative findings, however, intimal tear was seen in the anterior portion of the ascending aorta about 1cm below the brachiocephalic trunk and falselumen appeared after hematoma was removed from the layer of tunica media. We report a case of type A aortic dissection which mimicked clinical and diagnostic features of penetrating atherosclerotic ulcer.

Study on Realistic Disaster Management Service Implementation Plan : Focusing on Differential Views in Public and Private Experts (실감형 재난대응 서비스 구현방안 연구 : 공공과 민간 분야 전문가 인식 차이를 중심으로)

  • Choi, Woo-Chul;Kim, Tae-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.625-633
    • /
    • 2020
  • this study, an expert AHP questionnaire analysis of public and private groups was conducted to take into consideration the requirements for realistic disaster services. Considered are public areas that manage disasters like fires and earthquakes that can be a major threat to national safety, as well as private areas that mainly develop disaster-related technologies. In the questionnaire, the public respondents valued accurate disaster situation information (ranked 4th and 6th) for citizens (1st), managers (3rd), and related organizations (2nd); the private sector highly valued the importance of three-dimensional (3D) control (ranked 1st, 3rd, and 5th) using future technologies. This study suggests the realization of a disaster-response service that meets the needs of public safety and technological innovation based on a 3D safety state information platform. We anticipate that this study will provide useful data for applying technology and for establishing detailed scenarios during the test bed and commercialization phases. We also expect that further studies will be conducted, such as the practical application and operation of realistic disaster response services, on the financial resources for the proliferation of local governments, and on policy support measures.

The Design of 10-bit 200MS/s CMOS Parallel Pipeline A/D Converter (10-비트 200MS/s CMOS 병렬 파이프라인 아날로그/디지털 변환기의 설계)

  • Chung, Kang-Min
    • The KIPS Transactions:PartA
    • /
    • v.11A no.2
    • /
    • pp.195-202
    • /
    • 2004
  • This paper introduces the design or parallel Pipeline high-speed analog-to-digital converter(ADC) for the high-resolution video applications which require very precise sampling. The overall architecture of the ADC consists of 4-channel parallel time-interleaved 10-bit pipeline ADC structure a]lowing 200MSample/s sampling speed which corresponds to 4-times improvement in sampling speed per channel. Key building blocks are composed of the front-end sample-and-hold amplifier(SHA), the dynamic comparator and the 2-stage full differential operational amplifier. The 1-bit DAC, comparator and gain-2 amplifier are used internally in each stage and they were integrated into single switched capacitor architecture allowing high speed operation as well as low power consumption. In this work, the gain of operational amplifier was enhanced significantly using negative resistance element. In the ADC, a delay line Is designed for each stage using D-flip flops to align the bit signals and minimize the timing error in the conversion. The converter has the power dissipation of 280㎽ at 3.3V power supply. Measured performance includes DNL and INL of +0.7/-0.6LSB, +0.9/-0.3LSB.

Bradykinesia, Rigidity and Gait Disturbance Due to "Possible" Normal Pressure Hydrocephalus in a Patient with Anxiety and Bipolar Disorder : A Case Report (불안, 기분장애로 치료 중 보행장애 외에 서동과 강직을 동반한 정상뇌압수두증 증례)

  • Jang, Sae Heon;Jae, Young Myo;Choi, Jin Hyuk;Bae, Jung Hoon;Seong, Sang Yoon;Cho, Se Hoon;Kim, Young Hoon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.23 no.1
    • /
    • pp.66-69
    • /
    • 2015
  • In addition to classical triad such as gait disturbance, urinary incontinence and dementia, parkinsonian extrapyramidal motor signs and neuropsychiatric symptoms can be observed in patients with normal pressure hydrocephalus (NPH). In our case, a 46 year old female patient showed extrapyramidal symptoms such as bradykinesia, rigidity and neuropsychiatric symptoms such as agitation, anxiety, restlessness and regressed behavior beside two(gait disturbance & urinary incontinence) symptoms of three classical triad. It was difficult to diagnose this patient as NPH from the beginning because of her relatively young age and previous psychiatric mediation history for controlling advanced anxiety and affective disorder. Antiparkinsonian agents and discontinuation of psychiatric medications did not work for this patient. Patient's brain computed tomographic finding showed enlarged ventricles. We suspected NPH and did empirical drainage of 30mL CSF. Finally, patient's pyramidal and neuropsychiatric symptoms as well as two of three classical triad of NPH were improved dramatically within several days. It is important to consider NPH as one of the differential diagnosis in patient with parkinsonian symptoms and various neuropsychiatric symptoms who did not respond to usual clinical management especially in case of ventricular enlargement in neuroimaging because of its treatable property by CSF shunt operation.

MILP-Aided Division Property and Integral Attack on Lightweight Block Cipher PIPO (경량 블록 암호 PIPO의 MILP-Aided 디비전 프로퍼티 분석 및 인테그랄 공격)

  • Kim, Jeseong;Kim, Seonggyeom;Kim, Sunyeop;Hong, Deukjo;Sung, Jaechul;Hong, Seokhie
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.31 no.5
    • /
    • pp.875-888
    • /
    • 2021
  • In this paper, we search integral distinguishers of lightweight block cipher PIPO and propose a key recovery attack on 8-round PIPO-64/128 with the obtained 6-round distinguishers. The lightweight block cipher PIPO proposed in ICISC 2020 is designed to provide the efficient implementation of high-order masking for side-channel attack resistance. In the proposal, various attacks such as differential and linear cryptanalyses were applied to show the sufficient security strength. However, the designers leave integral attack to be conducted and only show that it is unlikely for PIPO to have integral distinguishers longer than 5-round PIPO without further analysis on Division Property. In this paper, we search integral distinguishers of PIPO using a MILP-aided Division Property search method. Our search can show that there exist 6-round integral distinguishers, which is different from what the designers insist. We also consider linear operation on input and output of distinguisher, respectively, and manage to obtain totally 136 6-round integral distinguishers. Finally, we present an 8-round PIPO-64/128 key recovery attack with time complexity 2124.5849 and memory complexity of 293 with four 6-round integral distinguishers among the entire obtained distinguishers.

A Thoracolumbar Pure Spinal Epidural Cavernous Hemangioma - A Case Report - (흉요추부에서 발견된 경막외 해면상 혈관종 - 증례 보고 -)

  • Choi, Byeong Sam;Kim, Ju Yeon;Lee, Sungjoon
    • Journal of Korean Society of Spine Surgery
    • /
    • v.25 no.4
    • /
    • pp.169-174
    • /
    • 2018
  • Study Design: Case report. Objectives: We report a case of pure epidural cavernous hemangioma located at the thoracolumbar spine in a 53-year-old woman that mimicked a neurogenic tumor on magnetic resonance imaging (MRI). Summary of Literature Review: A pure spinal epidural cavernous hemangioma without bony involvement is a very rare lesion about which limited information is available in the literature. Materials and Methods: A 53-year-old woman visited our clinic for hypoesthesia with a tingling sensation in the left anterolateral thigh that had begun a month ago. No other neurologic symptoms or signs were present upon a neurologic examination. MRI from an outside hospital showed a $2.0{\times}0.5cm$ elongated mass at the T11-12 left neural foramen. The tumor was completely removed in piecemeal fashion. Results: The histopathologic examination revealed a cavernous hemangioma, which was the final diagnosis. The outcome was favorable in that only operation-related mild back pain remained, without any neurologic deficits, after a postoperative follow-up of 2 years and 3 months. No recurrence was observed on MRI at 2 years postoperatively. Conclusion: Pure epidural spinal cavernous hemangioma is very rare, and it is very difficult to differentiate from other epidural lesions. However, we believe that it should be included in the differential diagnosis of spinal epidural tumors due to its favorable prognosis.