• Title/Summary/Keyword: Difference-In-Difference

Search Result 72,519, Processing Time 0.113 seconds

Effect of working time on the film thickness of dental resin cements (레진 시멘트의 혼합 후 시간에 따른 피막도의 변화)

  • Yi, Yu-Seung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung;Ha, Seung-Ryong;Kim, Hee-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.325-329
    • /
    • 2015
  • Purpose: The aim of this study was to compare the film thicknesses of several resin cements as a function of time after mixing and to examine the effect of working time on the film thicknesses. Materials and methods: The film thickness (${\mu}m$) of 4 resin cements (n=10), 1 composite resin (Panavia F 2.0), 3 self-adhesive resin (Clearfil SA luting, Zirconite, RelyX U200) cements was measured at 20-second intervals after mixing of the cements up to 200 seconds under a load of 50 N. Linear regression was fitted to verify the effect of working time on the film thickness of each cement. Data were compared to the working time recommended by manufacturers using Wilcoxon test ($\alpha$=.05). Results: All of the materials showed a positive linear correlation between the film thickness and working time. There was no statistically significant difference between the working time based on our results and the values recommended by the manufacturers even though there was a discrepancy between those two values. Conclusion: The film thickness of resin cements could increase with the increase of working time. Working time to meet the ISO standard of $50-{\mu}m$ maximum film thickness could be different from the manufacturer's recommended value.

Surface roughness and $Candida$ $albicans$ adhesion to flexible denture base according to various polishing methods (연마방법에 따른 탄성의치의 표면거칠기와 $Candida$ $albicans$의 부착율 변화)

  • Oh, Ju-Won;Seo, Jae-Min;Ahn, Seung-Keun;Park, Ju-Mi;Kang, Cheol-Kyun;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.106-111
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the effect of 3 chairside polishing methods and laboratory polishing methods on surface roughness and $C.$ $albicans$ adhesion of polyamide denture base. Materials and methods: Using contact profilometer, the surface of polyamide specimens ($25{\times}15{\times}2mm$) was studied after conventional polishing without finishing and after chiarside polishing with 2 chiarside polishing kits and chairside-pumice polishing following finishing with tungsten carbide bur. To evaluate the adhesion of $C.$ $albicans$, $C.$ $albicans$ suspension was overlayed on the test specimen. And the specimens were incubated for 2 hours. Imprint culture method was achieved and counted the colony on the agar plate. Polished polyamide were evaluated using a scanning electron microscope. The statistics were conducted using one-way ANOVA and in case of difference, Scheffe test and Tamhane's T2 test were used. Results: Surface roughness (Ra) of surfaces polished with 2 chairside polishing kits had higher than conventional polishing and pumice polishing. The highest roughness value was $0.32{\pm}0.10{\mu}m$, and the lowest was $0.02{\pm}0.00{\mu}m$. The adhesion of $C.$ $albicans$ on the specimens polished with chairside polishing group and pumice polishing group were increased than conventional polishing group ($P$<.01). Conclusion: Conventional laboratory polishing was found to produce the smoothest surface and the lowest adhesion of $C.$ $albicans$. Two groups polished with Chairside polishing kits were similar with respect to surface roughness. Surface of the specimen polished with pumice is significantly smoother than 2 chairside polishing groups, but the result of $C.$ $albicans$ adhesion is that group polished with pumice was similar with 2 chairside polishing groups ($P$>.01).

Characterization and Conversion Electron Mössbauer Spectroscopy of HoMn1-x-FexO3 Thin Films by Pulsed Laser Deposition (PLD를 이용한 HoMn1-x-FexO3 박막 제조 및 후방 산란형 뫼스바우어 분광 연구)

  • Choi, Dong-Hyeok;Shim, In-Bo;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.1
    • /
    • pp.18-21
    • /
    • 2007
  • The hexagonal $HoMn_{1-x}-Fe_xO_3$(x=0.00, 0.05) thin films were prepared using pulsed laser deposition(PLD) method on $Pt/Ti/SiO_2/Si$ substrate. The microstructure and magnetic properties have been studied by x-ray diffraction(XRD), atomic force microscopy (AFH), scanning electron microscope(SEM:), x-ray photoelectron spectroscopy(XPS), and conversion electron $M\"{o}ssbauer$ spectroscopy(CEMS). From the analysis of the x-ray diffraction patterns, the crystal structure for all films was found to be a hexagonal($P6_3cm$), which was preferentially grown along(110) direction. The lattice constant $c_0$ of the film with x=0.05 was close to that of single crystal, whereas lattice constant $a_0$ with respect to single crystal shows a slight decrease. This difference of lattice parameters between film and single crystal was caused by the lattice mismatch between the film and $Pt/Ti/SiO_2/Si$ substrate. Conversion electron $M\"{o}ssbauer$ spectrum of $HoMn_{0.95}Fe_{0.05}O_3$ thin film shows an asymmetry doublet absorption ratio at room temperature, which is due to the oriented direction of crystallographic domains. This is corresponding with analysis of x-ray diffraction. The quadrupole splitting(${\Delta}E_Q$) at room temperature is found to be $1.62{\pm}0.01mm/s$. This large ${\Delta}E_Q$ was caused by asymmetry environment surrounding Fe ion.

Effect of Light Quality during $GA_3$ Imbibition and Germination Temperature on Pepper Seed Germinability (파종 전 $GA_3$와 광질 처리, 발아온도에 따른 고추종자의 발아율)

  • 강진호;심영도;강신윤;조영욱;박아정
    • Korean Journal of Plant Resources
    • /
    • v.12 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • Higher and uniform germination should be necessary because many commercial pepper (Capsicum annum L.) seedlings were nowadays sold to farmer. The experiment was carried out to determine the effect of its cultivars (Daemyung; Wanggochu), GA$_3$ (concentration; period), light quality (red; far-red; blue; dark) during GA$_3$imbibition, and germination temperature (GT: 25 or 15$^{\circ}C$ constant; 25/15$^{\circ}C$ alternating) on the rate of germination done under incandescent lamps until 9 days after sowing. Final seed germination was not different between GA$_3$0 to 1.0 mM concentrations but the elapsed days to 50% germination $(T_{50})$ were more reduced by GA$_3$ treatment than water imbibition. Under $25^{\circ}C$ constant germination temperature, earlier germination was enhanced by GA$_3$treatment showing the lowest rate at darkness, although the final germination rates of water imbibition and GA$_3$ treatments were same. The final germination rates of alternating and 25 $^{\circ}C$ constant GT in cv. Daemyng was also equal, while the germination rates of $25^{\circ}C$ and 15$^{\circ}C$ constant GT were the highest and the lowest regardless of cultivars. There was no difference between light quality treatments impelled during GA$_3$ imbibition when light treated seeds were germinated at alternating and $25^{\circ}C$ constant GT. At 15$^{\circ}C$ constant GT, however, red light or dark treatment during GA$_3$imbibition increased the germination rate since 5 days after sowing.

  • PDF

Characteristics of Maize Line Treated with Mutagen of γ-Ray at M1 Generation (돌연변이원(突然變異原) γ-선(線)을 처리(處理)한 M1 세대(世代) 옥수수 계통(系統)의 특성(特性))

  • Lee, Hee Bong
    • Korean Journal of Agricultural Science
    • /
    • v.22 no.2
    • /
    • pp.156-162
    • /
    • 1995
  • This study was carried out to select the useful mutants among 20 lines treated with mutagen, gamma ray. These materials were treated with 15, 20, 25 and 30Krads, respectively and sowed at experimental field of College of Agriculture on 27th May, 1995. Items surveyed were germination rate and loss of chlorophyll at seedling stages, abnormal reproductive organs, discordance of flowering times and stem and ear height at ripening stages. The germination rate of lines treated with 15 Krad was different. The germination rate of the IK1, IK2 and Sinki lines were high, while the IK3, A632 and FR140 lines were very low. At same dose level, the germination rate of both IK1/H26 and Puyo synthetic variety were different; the germination rate of the IK1/H26 was high as above 70% at all treatments, while that of the Puyo synthetic variety was very poor at above 20 Krad. Generally stem adn ear height of the IK1/H26 were gradually decreased as the dose of mutagen increased, but there was no difference in stem and ear height of the IK1/H26 when this line was treated with 20Krad. The stem and ear height of lines treated with 15 Krad were shown to be decreased than those of check with non-treatment. The number of tiller of tillering lines were not greatly affected by ${\gamma}$-ray treatment.

  • PDF

Experimental Model of Cardiac Xenograft, Mouse Heart to Rat. (이종이형의 심장이식의 실험적 모델)

  • Kim, Byung-Il;Sohn, Sang-Tae;Shin, Sung-Ho;Chung, Won-Sang;Kim, Hyuk;Kim, Young-Hak;Kang, Jung-Ho;Jee, Heng-Ok;Lee, Chul-Burm;Seo, Jung-Kuk
    • Journal of Chest Surgery
    • /
    • v.32 no.1
    • /
    • pp.1-4
    • /
    • 1999
  • Background: The transplantation of organs between phylogenetically disparate or harmonious species has invariably failed due to the occurrence of hyperacute rejection or accerelated acute rejection. But, concordant cardiac xenograft offer us an opportunity to study xenotransplantation in the absence of hyperacute rejection. Current therapeutics for the prolongation of survival of rodent concordant xenotransplantation are not ideal with many regimens having a high mortality rate. Cyclosporine A & Mycophenolate Mofetil are new immunosuppresive agent which has been shown to be effective at prolonging survival of allograft, as purine synthesis inhibitor. Material and Method: We used white mongrel rats as recipient and mice as donor, divided 4 groups(n=6), control group(Group 1) has no medication or pretreatment, Group 2 has splenectomy as pretreatment 7∼10 days before transplantation, Group 3 has Cyclosporine A treatment group, Group 4 has combined treatment of Cyclosporine A & Mycophenolate Mofetil(RS 61443). We compared survival time. Reuslt: We can't find significant difference of survival time between each groups. Conclusion: We concluded that rejection of cardiac xenograft was different from rejection of allograft, and new immunossuppresive Agent(Mycophenolate Mofetil, Cyclosporine A) was not effective for prolongation of survival time after cardiac xenograft.

  • PDF

Effect of Water Stress on Growth of Ligusticum chuanxiong $H_{ORT}$ (토양수분(土壤水分) 불족(不足)이 토천궁(土川芎)의 생육(生育)에 미치는 영향(影響))

  • Kim, Chung-Guk;Kang, Byeung-Hoa;Koh, Mun-Hwan;Jung, Dong-Hee;Seo, Jong-Ho
    • Korean Journal of Medicinal Crop Science
    • /
    • v.4 no.4
    • /
    • pp.301-307
    • /
    • 1996
  • The experiment was conducted to clarify the effect of water stress treatment on growth character of Ligusticum chuanxiong Hort. The water stress treatment was imposed artificially on seedling, flowering and rhizome enlargement stage of the plant. The decrease ratio of leaf area compare with control decreased to 24.4% by water stress treatment at seedling stage and to 41.6% at rhizome enlargement stage. The reduction rate of chlorophyll content at the end of water stress treatment was 41.2% at the see­dling stage and no difference at the flowering stage. The chlorophyll content of water stress treatment on seedling and flowering stage was recovered to 95% at harvest time. The ratio of rootlet distribution from top soil to l0cm depth showed maximum to 90% at the seedling stage and to 20cm depth showed max­imum to 6.4% at the rhizome enlargement stage. The dry weight of rootlet was decreased to $19.3{\sim}40.3%$ by water stress treatment. Dry weight of aerial part and underground part of the plant decreased in the order of seedling, flowering, rhizome enlargement and control and the dry weight of aerial part decrease more severely than underground part.

  • PDF

Study on the beam properties of small field sizes (소조사면 전량분포의 특성에 관한 고찰)

  • Cho JeongHee;Lee SangKyu;An SeungKwon;Park Jell
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • Purpose : The aim of this study is to investigate the properties of small field size and to measure the penumbra and central axis depth dose varying to the jaw setting and off axis distance for indicate this data to small field sizes radiation therapy. Material and methods : The percentage depth dose, beam profile and central axis output dose was measured by farmer type ion chamber and pinpoint chamber using Primart linac with 6MV energy. Beam quality and penumbra variations according to the central axis shift, from center to every 2cm outside increment, and field size, from $1{\times}1cm$ to $10{\times}10cm$ was investigated and compared with that of the standard geometrical condition's results Results : The differences of measured values between two ion chamber was about $37\%$ at 10cm depth with $1{\times}1cm$ field sizes but as field size increased this differences was diminished gradually. Measured data from various off axis distance with the different asymmetric collimations are not changed significantly but as size decreased the dose variation was increased and at $1{\times}1cm$ field size dose difference among off axis distance was as much as $13\%$, and as shallower the measured depth the central axis dose variations among the OAD was increased, penumbra was not changed noticeably depending on off axis distance but the percentage of penumbra from its initial field sizes was strongly dependant on field sizes and penumbra occupation rates of its own field sizes ranging from $6\%$ at $10{\times}10cm$ to $50\%$ at $1{\times}1cm$ field size. Conclusion : For imrt treatment, there are several numbers of different gentry angles with beams of nonuniform fluences are required and several complex factors involved. Among them the characteristics of beam output varying to the geometrical setting and design of collimators are of important to attaining a good treatment results. As mentioned in results the differences of measured values are changed significantly depends on ion chamber volume, depths and field size. For providing quality radiation treatment, especially at small field size, those factor's should have considering deliberately.

  • PDF

ACL reconstruction with autologous hamstring tendon - Short term clinical result using new femoral suspensory fixation device 'Cross Pin' and graft tensioner for maintaining a constant tension- (자가 슬괵건을 이용한 전방 십자 인대 재건술 - 새로운 대퇴부 현수고정법인 Cross Pin과 일정한 긴장력 유지를 위한 Graft Tensioner 사용의 단기 추시 결과 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Kim, Jin-Seok;Choi, Sang-Yeong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: To evaluate the short term clinical result of ACL reconstruction with autologous hamstring tendon using Cross pin and Graft Tensioner and to seek way to resolve the experienced technical problems. Materials and Methods: From January 2008 to March 2009, 35 patients who had been treated arthroscopic ACL reconstruction were enrolled. The femoral side of ACL graft was fixed with Cross pin. The tibial side of graft was fixed with Intrafix and post-tie. The graft was tensioned with Graft Tensioner at 80N. We analyzed the clinical, radiographic results and complications. Results: IKDC subjective score and Lysholm score improved to 89.1 and 91.4 points. Also, Pivot shift test and One-leg hop test showed good results postoperatively. Side to side difference using KT-1000 arthrometer and Telos stress radiography improved compared with normal limb to $2.8{\pm}1.6$ mm and $2.6{\pm}1.3$ mm, respectively. The femoral tunnel enlarged to $2.3{\pm}1.1$ mm. Soft tissue irritation and femoral tunnel-graft harness length mismatch, femoral tunnel-cross pin tunnel mismatch were happened as peri-operative complications. Conclusion: Using of Cross pin and Graft Tensioner for ACL reconstruction with hamstring tendon is one of the good method for obtaining stability in short-term clinical result. But to reduce femoral tunnel-cross pin mismatch, it needs to shorten femoral bone tunnel and to create cross pin tunnel as vertical as possible. And to reduce femoral tunnel-graft harness mismatch, it needs to advance position rod further 3 mm when to create femoral tunnel.

  • PDF

Preparation of Edible Films from Soybean Meal (대두박을 이용한 가식성 필름의 제조에 관한 연구)

  • Yang, Sung-Bum;Cho, Seung-Yong;Rhee, Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.452-459
    • /
    • 1997
  • Effect of extraction pH on mechanical properties such as tensile strength (TS) and elongation (E) and on water vapor permeability (WVP) of soybean protein isolate (SPI) edible films extracted from soybean meal was investigated. Five pHs, acidic range (pH 2.0 and pH 3.0), neutral range (pH 7.0) and alkalic range (pH 10.0 and 12.0), were used to extract SPI. TS of the film extracted at pH 7.0 was the lowest, and WVP of $SPI_3$ (SPI extracted at pH 3) film was the lowest value among the films. The WVP of $SPI_3$ films was $3.349\;{\times}\;10^{-10}\;g{\cdot}m/m^2{\cdot}s{\cdot}Pa$ and increased to $3.871\;{\times}\;10^{-10}\;g{\cdot}m/m^2{\cdot}s{\cdot}Pa$ as film thickness increased from $55\;{\mu}m$ to $72\;{\mu}m$ thickness. Three different plasticizers (glycerol, polyethylene glycol and propylene glycol) were used for $SPI_2$ (SPI extracted at pH 2) film. TS of $SPI_2$ films was 12.297 MPa and decreased to 1.356 MPa for glycerol and showed the same trend in other two plasticizers. The SPI films extracted at acidic range were shown higher mechanical properties and lower water vapor permeabilities than those of extracted at neutral and alkalic ranges. The difference of SPI film properties seemed to be attributed by 11S/7S ratio as well as protein content.

  • PDF