An Investigation into the Actual Condition of Electrical Equipments Installation for the Inspection Method Development Based on IEC 60364 (IEC 60364기반 건축전기설비 점검기법 개발을 위한 현장실태 조사)

  • Jung, Jin-Soo;Han, Woon-Ki;Lee, Han-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.36-41
    • /
    • 2009
  • In this paper an Investigation into the actual condition of electrical equipment installation for the inspection method development based on IEC 60364. The analysis objects are the difference between electrical equipments installation in korea & electrical equipments installation based on the IEC 60364. The measurement elements are loop impedance, operating characteristic of circuit breaker and protective conductor continuance. As a result, the korea electrical equipments installation was almost same the TT system but some different of protective conductor continuance. Electrical equipments installed TN-C-S has noting problem about installation but manager dose not understand about IEC 60364.

Postbuckling Analysis of Thin Plates under Impact Loading (충격하중을 받는 박판의 후좌굴 해석)

  • Kim, Hyeong-Yeol;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.3
    • /
    • pp.139-149
    • /
    • 2002
  • An explicit direct time integration method based solution algorithm is proposed to predict dynamic postbuckling response of thin plates. Based on the von Karman's plate equations and Marquerre's shallow shell theory, a rectangular plate finite element is formulated and utilized in this study. The element formulation takes into account geometrical nonlinearity and initial deflection of plates. The solution algorithm employs the central difference method. Using the computer program developed by the authors, dynamic postbuckling behavior of elastic thin plates under impact loading is investigated by considering the time variation of load and load duration. The efficiency of the proposed solution algorithm is examined through illustrative numerical examples.

A Study on the On-site Flame Resistant Inspection Method by X-ray Fluorescence Spectrometer (X-선 형광분석기를 이용한 현장방염검사방법에 관한 연구)

  • Kim, Hwang-Jin;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.124-129
    • /
    • 2016
  • According to the current law, on-site flame resistant-treated interior decorations should pass the flame resistant performance test through a 45 degree combustion test from the district fire department. Although a 45 degree combustion test is the most accurate method for determining the flame resistant performance, it can be unreliable when tested on unauthorized samples. To avoid unauthorized sampling, this study suggests on-site flame resistant inspection by X-ray fluorescence spectrometer. Ten types of flame resistant paint were spread on plywoods and MDFs and the components were analyzed by X-ray fluorescence spectrometer. As a result, due to a difference amounts of substances in each paint, each flame resistant paints showed its own characteristic spectrum and the contents of each substance could be determined. On-site flame resistant inspections can be used efficiently when institutional procedures are created.

Pattern Elimination Method Based on Perspective Transform for Defect Detection of TFT-LCD (TFT-LCD의 결함 검출을 위한 원근 변환 기반의 패턴 제거 방법)

  • Lee, Joon-Jae;Lee, Kwang-Ho;Chung, Chang-Do;Park, Kil-Houm;Park, Yun-Beom;Lee, Byung-Gook
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.6
    • /
    • pp.784-793
    • /
    • 2012
  • Defects of TFT-LCD is detected by thresholding the difference image between the input image and template one because LCD panel has its inherent patterns. However, the pitch corresponding to pattern period is gradually changed according to the distance from the center of camera due to geometric distortion of camera characteristics. This paper presents a method to detect defects through comparing the pitch area with neighbor pitch areas where the perspective transform is performed with the extracted features to correct the distortion. The experimental results show that the performance of the proposed method is very effective for real data.

Assessment of Shear Strength Parameter for Weathered Soils Using Artificial Neural Network (인공신경망을 이용한 풍화토의 강도정수 산정)

  • Lee, Moo-Cheol;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.147-154
    • /
    • 2008
  • Weathered soil slope loses its shear strength if it is exposed in the air for a long time or in contact with water. And this kind of strength loss is remarkable in dam slope which has very big difference in water level according to the season. In this study, shear strength loss of weathered soil due to saturation had been found out through dryness and wetness repetition direct shear test. Also relation between penetration blow number(Nc) and shear strength parameter had been found out through small sized dynamic cone penetration test device and the correlation equation of Nc had been proposed through artificial neural network analysis to estimate shear strength parameter easily.

Study on the Color Changing of Pine by Accelerated Weathering Test (소나무재의 촉진열화실험에 따른 재색변화에 대한 연구)

  • Kim, Gwang-Chul
    • Journal of the Korea Furniture Society
    • /
    • v.23 no.2
    • /
    • pp.152-162
    • /
    • 2012
  • The color changing of the wood surface was tested by accelerated weathering test that can simulate the outdoor condition with short period. In early parts of accelerated weathering test, weight and volume of specimen all were increased due to the moisture evaporation by its high temperature and illumination level, but weight and volume of specimen all were decreased from middle parts to last. However, significancy showed between control group and accelerated weathering test group in terms of weight and volume. According to the results of color-difference meter, in the early parts of the accelerated weathering test lightness, redness and yellowness all showed a clear increasing or decreasing trend. However, after three weeks all values were almost never change. Until the early parts of the test, lightness was decreased and there was not a considerable change after three weeks in the test. Redness showed a some change in early parts of the test, but this also showed not great change after middle parts of the test as like lightness. Yellowness also showed same pattern. These results could be verified through the visual inspection. As like weight and volume, significancy showed between control group and accelerated weathering test group in terms of color-difference test. In all accelerated weathering test group, color-differences of after test was lower than that of before test. To correctly analyze this cause, more additional research will be need on each of temperature, humidity and illumination factors.

  • PDF

Effect of Gym-ball Exercise Program to Pelvis and Spine of the 20's Woman

  • Oh, Seung-Hyean;Yoo, Kyung-Tae
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.4
    • /
    • pp.339-345
    • /
    • 2014
  • PURPOSE: This study is to investigate the effect of 4 weeks of gym ball exercise on the pelvis and spine of women in 20s. METHODS: Randomly selected 10 of 20 subjects are allocated to experimental group who will practice gym-ball exercise while the rest 10 subjects are allocated to control group. Values for pelvic obliquity DL-DR, pelvic torsion DL-DR, pelvic rotation, kyphotic angle ICT-ITL (max), and lordotic angle ITL-ILS (max) were measured through recording using 3-dimensional image analyzer as a preliminary inspection. Gym-ball exercise was implemented 3 sessions a week for 4 weeks. Each session consisted of 10 minutes of warm up exercise, 30 minutes of main exercise, and 10 minutes of cool down exercise totaling 50 minutes. Post inspections were measured after exercise. RESULTS: Experimental group showed statistically significant difference in pelvic obliquity DL-DR, pelvic torsion DL-DR, and kyphotic angle ICT-ITL (max) (p<.05) and values of pelvic obliquity DL-DR showed statistically significant difference between two groups (p<.05). However pelvic rotation, lordotic angle ITL-ILS (max) did not show a significant difference. CONCLUSION: These results showed that gym-ball exercise has positive effect in the pelvic obliquity, torsion and spine kyphotic angle and expected to have positive effect on the body balance, body lineup, and coordination.

The Effects of Individualized Cognitive Program on LOTCA-G and ADL in Elderly with Dementia and Mild Cognitive Impairment (맞춤형 인지프로그램이 치매와 경도인지손상노인의 LOTCA-G 및 일상생활동작에 미치는 영향)

  • Lee, Hyojeong
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.1
    • /
    • pp.21-29
    • /
    • 2016
  • Purpose : The purpose of this study was to evaluate the influence of LOTCA-G and ADL by individualized cognitive program in elderly with vascular dementia, alzheimer dementia and mild cognitive impairment. Method : The subjects of this study, old man and woman diagnosed with vascular dementia, alzheimer dementia and mild cognitive impairment, 24 patients were picked up, who were agreed with this research and were having hospital care for 3weeks at nursing care centers. Individualized cognitive program was applied to 8 patients of vascular dementia, 8 patients of alzheimer dementia and 8 patients of mild cognitive impairment. Cognitive function measured by LOTCA-G and performance measured by FIM. The SPSS Ver. 22.0 statistical program was used for data processing. The significance level for statistical inspection was set as 0.05. Result : In comparison of LOTCA-G was significant increased after intervention and among three groups were significant difference. But FIM was no significant difference after intervention and among three groups were no significant difference. Conclusion : Therefore, the individualized cognitive program is useful to improve the cognitive function in elderly with dementia and mild cognitive impairment.

Impact location on a stiffened composite panel using improved linear array

  • Zhong, Yongteng;Xiang, Jiawei
    • Smart Structures and Systems
    • /
    • v.24 no.2
    • /
    • pp.173-182
    • /
    • 2019
  • Due to the degradation of beamforming properties at angles close to $0^{\circ}$ to $180^{\circ}$, linear array does not have a complete $180^{\circ}$ inspection range but a smaller one. This paper develops a improved sensor array with two additional sensors above and below the linear sensor array, and presents time difference and two dimensional multiple signal classification (2D-MUSIC) based impact localization for omni-directional localization on composite structures. Firstly, the arrival times of impact signal observed by two additional sensors are determined using the wavelet transform and compared, and the direction range of impact source can be decided in general, $0^{\circ}$ to $180^{\circ}$ or $180^{\circ}$ to $360^{\circ}$. And then, 2D-MUSIC based spatial spectrum formula using uniform linear array is applied for locate accurate position of impact source. When the arrival time of impact signal observed by two additional sensors is equal, the direction of impact source can be located at $0^{\circ}$ or $180^{\circ}$ by comparing the first and last sensor of linear array. And then the distance is estimated by time difference algorithm. To verify the proposed approach, it is applied to a quasi-isotropic epoxy laminate plate and a stiffened composite panel. The results are in good agreement with the actual impact occurring position.

Material Discrimination Using X-Ray and Neutron

  • Jaehyun Lee;Jinhyung Park;Jae Yeon Park;Moonsik Chae;Jungho Mun;Jong Hyun Jung
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.167-174
    • /
    • 2023
  • Background: A nondestructive test is commonly used to inspect the surface defects and internal structure of an object without any physical damage. X-rays generated from an electron accelerator or a tube are one of the methods used for nondestructive testing. The high penetration of X-rays through materials with low atomic numbers makes it difficult to discriminate between these materials using X-ray imaging. The interaction characteristics of neutrons with materials can supplement the limitations of X-ray imaging in material discrimination. Materials and Methods: The radiation image acquisition process for air-cargo security inspection equipment using X-rays and neutrons was simulated using a GEometry ANd Tracking (Geant4) simulation toolkit. Radiation images of phantoms composed of 13 materials were obtained, and the R-value, representing the attenuation ratio of neutrons and gamma rays in a material, was calculated from these images. Results and Discussion: The R-values were calculated from the simulated X-ray and neutron images for each phantom and compared with those obtained in the experiments. The R-values obtained from the experiments were higher than those obtained from the simulations. The difference can be due to the following two causes. The first reason is that there are various facilities or equipment in the experimental environment that scatter neutrons, unlike the simulation. The other is the difference in the neutron signal processing. In the simulation, the neutron signal is the sum of the number of neutrons entering the detector. However, in the experiment, the neutron signal was obtained by superimposing the intensities of the neutron signals. Neutron detectors also detect gamma rays, and the neutron signal cannot be clearly distinguished in the process of separating the two types of radiation. Despite these differences, the two results showed similar trends and the viability of using simulation-based radiation images, particularly in the field of security screening. With further research, the simulation-based radiation images can replace ones from experiments and be used in the related fields. Conclusion: The Korea Atomic Energy Research Institute has developed air-cargo security inspection equipment using neutrons and X-rays. Using this equipment, radiation images and R-values for various materials were obtained. The equipment was reconstructed, and the R-values were obtained for 13 materials using the Geant4 simulation toolkit. The R-values calculated by experiment and simulation show similar trends. Therefore, we confirmed the feasibility of using the simulation-based radiation image.