• Title/Summary/Keyword: Difference expansion

검색결과 963건 처리시간 0.152초

New reversible data hiding algorithm based on difference expansion method

  • Kim, Hyoung-Joong;Sachnev, Vasiliy;Kim, Dong-Hoi
    • 방송공학회논문지
    • /
    • 제12권2호
    • /
    • pp.112-119
    • /
    • 2007
  • Reversible data embedding theory has marked a new epoch for data hiding and information security. Being reversible, the original data and the embedded data as well should be completely restored. Difference expansion transform is a remarkable breakthrough in reversible data hiding scheme. The difference expansion method achieves high embedding capacity and keeps the distortion low. This paper shows that the difference expansion method with simplified location map, and new expandability and changeability can achieve more embedding capacity while keeping the distortion almost the same as the original expansion method.

라텍스개질 콘크리트의 열팽창 특성 분석 (Analysis of Thermal Expansion of Latex-Modified Concrete)

  • 최성용;이주형;임홍범;윤경구
    • 산업기술연구
    • /
    • 제23권A호
    • /
    • pp.157-163
    • /
    • 2003
  • The properties of mechanics and durability of LMC have been performed actively. However, little studies on analysis and properties of thermal expansion has been on the temperature variation. Especially, the low of bonding strength and tensile cracking are caused by difference of thermal expansion between LMC and the substrate concrete. Therefore, this study focused on effect of thermal expansion behavior and properties of LMC according to temperature variation. To identify the property of thermal expansion of LMC, tests of modulus of thermal expansion were carried out at 28 days after casting specimen, subjected to temperature variation between $10^{\circ}C$ and $60^{\circ}C$. The results of this study showed the modulus of elastic of LMC was similar to that of ordinary portland concrete(OPC). It means that stresses caused by difference of modulus of elastic did not occur on interface between LMC and existing concrete. The modulus of thermal expansion of LMC had a little smaller than that of OPC. The modulus of thermal expansion of polymer modified concrete is generally larger than OPC, but the result of this test is disagree with the fact, which may be due to the humidity evaporation difference and aggregate properties.

  • PDF

The Effect of 3-Dimensional Posture Correction Exercise Program Incorporating PNF Respiratory Muscle Strengthening Exercise on the Spinal Alignment and the Trunk Expansion in Patients with Idiopathic Scoliosis

  • Yoon, Sungyoung;Seok, Him;Heo, Jaeseok;Lee, Sangyeol
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권4호
    • /
    • pp.430-437
    • /
    • 2021
  • Objective: The purpose of this study was to investigate the effect of 3-dimensional posture correction(3DPC) exercise program incorporating PNF respiratory muscle strengthening(RMS) exercise on spinal alignment and trunk expansion in patients with idiopathic scoliosis and the difference in intervention effect by type of idiopathic scoliosis. Design: Comparative study using paired t-test and analysis of variance measures. Methods: The subjects of this study were 5 men and 24 women diagnosed with idiopathic scoliosis with a Cobb angle greater than 10 degrees and less than 45 degrees. A 3DPC exercise program incorporating PNF RMS exercise was conducted twice a week for 1 hour per session for 6 weeks, and Cobb angle, Angle of trunk rotation, and trunk expansion were measured before and after the intervention. Results: After the intervention, Cobb angle and trunk rotation angle showed a statistically significant decrease, and trunk expansion showed a statistically significant increase. In the effect difference by type, there was a statistically significant difference in the angle of trunk rotation of the thoracic in 3C and Single Lumbar. Conclusions: In conclusion, it is thought that a 3DPC exercise program incorporating PNF RMS exercise can be effectively used in clinical practice to improve spinal alignment and trunk expansion in patients with idiopathic scoliosis.

히스토그램 이동과 차분을 이용한 가역 비밀 이미지 공유 기법 (Reversible Secret Image Sharing Scheme Using Histogram Shifting and Difference Expansion)

  • 전병현;이길제;정기현;유기영
    • 한국멀티미디어학회논문지
    • /
    • 제17권7호
    • /
    • pp.849-857
    • /
    • 2014
  • In this paper, we propose a (2,2)-reversible secret image sharing scheme using histogram shifting and difference expansion. Two techniques are widely used in information hiding. Advantages of them are the low distortion between cover and stego images, and high embedding capacity. In secret image sharing procedure, unlike Shamir's secret sharing, a histogram generate that the difference value between the original image and copy image is computed by difference expansion. And then, the secret image is embedded into original and copy images by using histogram shifting. Lastly, two generated shadow images are distributed to each participant by the dealer. In the experimental results, we measure a capacity of a secret image and a distortion ratio between original image and shadow image. The results show that the embedding capacity and image distortion ratio of the proposed scheme are superior to the previous schemes.

Low Thermal Expansion of $Al_2TiO_5$ Ceramics Prepared from Electrofused Powders

  • Kim, Ik-Jin;Kwak, Hyo-Sup
    • The Korean Journal of Ceramics
    • /
    • 제5권4호
    • /
    • pp.414-418
    • /
    • 1999
  • The synthesis of polycrystalline $Al_2TiO_5$ ceramics with low thermal expansion by fusion in an electric arc furnance was investigated. The thermal expansion curves of $Al_2TiO_5$ ceramics were lowered because of microcracks caused by the strong thermal expansion anisotropy of the crystal axes and were accompanied by hysteresis curves. These phenomena are explained by the opening and closing of microcracks. The difference in microcracking temperatures of dilatometric cooling curves in the range of 400~$620^{\circ}C$ is caused by the difference in sintering temperature, grain size and stabilization status.

  • PDF

도재소부전장금관용 Opaque 분말과 도재전장관용 core 분말의 물리화학적 성질 및 금속과의 결합력에 대한 비교연구 (A COMPARATIVE STUDY OF THE PHYSICOCHEMICAL PROPER TIES AND BOND STRENGTH TO METAL BETWEEN THE REGULAR OPAQUE POWDER AND CORE POWDER)

  • 임장섭;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제35권1호
    • /
    • pp.144-164
    • /
    • 1997
  • The purpose of this study were to investigate the chemical composition, mean particle size, linear thermal expansion coefficient and metal-bonding strength of the regular opaque powder and core powder. In this study, 4 types of ceramic powders, namely Duceram Jacket Opaque powder, Duceram Opaque powder, Vita Hi-Ceram powder, Vita VMK Paint On-88 powder were used. Chemical composition was evaluated by EDS(Energy Dispersive X-ray Spectrophotometer, Oxford QX-2000, England), particle size was measured by MALVERN Instruments(MALVERN Instruments SB. OC., U.S.A.. ad linear thermal expansion coefficient was measured by dilatometer(Motoyama, Japan). Bond strength was measured by the Universal tsting machine(Istron Co., Ltd., U.S.A.). The Results were as follows : 1. Through recognition of the relative difference in chemical composition between the core powder and the regular opaque powder, the difference in the proportion of $Al_2O_3$ in each type of material is demonstrated ; Duceram Jaket Opaque powder : 30.16%, Duceram Opaque powder : 16.60%, Vita Hi-Ceram : 63.64%, Vita VMK Paint-On 88 : 16.16%. 2. There was no significant difference in the proportion of metal-bonding materials between the core powder and the regular opaque powder. 3. In the regular opaque powder, alkaline materials were incoporated in order to increase the coefficient of thermal expansion. 4. In the particle size analysis, there was no significant difference in mean particle size or in the particle size distribution between the core powder and the regular opaque powder. 5. In the thermal expansion test for temperature range of $25-600^{\circ}C$, the regular opaque powder had higher coefficient of thermal expansion than that of core powder. 6. In the 4 point flexural bending test, there was no statistically significant difference in the mean bond strength between the core powder and the opaque powder among the Duceram products.

  • PDF

Comparison of changes in the nasal cavity, pharyngeal airway, and maxillary sinus volumes after expansion and maxillary protraction with two protocols: Rapid palatal expansion versus alternate rapid maxillary expansion and constriction

  • Weitao Liu;Shaonan Zhou;Edwin Yen;Bingshuang Zou
    • 대한치과교정학회지
    • /
    • 제53권3호
    • /
    • pp.175-184
    • /
    • 2023
  • Objective: To evaluate and compare a series of volume changes in the nasal cavity (NC), nasopharynx, oropharynx, and maxillary sinuses (MS) in growing Class III patients after either rapid palatal expansion (RPE) or alternate rapid maxillary expansion and constriction (Alt-RAMEC) followed by facemask (FM) therapy, by using cone-beam computed tomography (CBCT). Methods: Forty growing Class III patients were retrospectively selected and divided into two matched groups: RPE/FM (14 females, 6 males; mean age, 9.66 ± 1.23 years) and Alt-RAMEC/FM groups (14 females, 6 males; mean age, 10.28 ± 1.45 years). The anteroposterior and vertical displacements of Point A, the volumes of the NC, nasopharyngeal, oropharyngeal, and MS were measured at different time points: pretreatment (T1), postexpansion (T2), and postprotraction (T3). Results: Both groups demonstrated significant maxilla advancement (by 1.3 mm) during expansion, with a statistically significant intergroup difference during protraction (RPE/FM, 1.1 mm; Alt-RAMEC/FM, 2.4 mm; p < 0.05) and throughout the treatment (RPE/FM, 2.4 mm; Alt-RAMEC/FM, 3.7 mm; p < 0.05). NC and nasopharyngeal airway volumes increased significantly in both groups after expansion, protraction, and treatment. The oropharyngeal and MS volumes increased in both groups after protraction and post-treatment. However, no volumetric differences were observed between the two groups. Conclusions: There was no significant difference in airway volume changes, including NC, nasopharyngeal, oropharyngeal airway, and MS, between RPE/FM and Alt-RAMEC/FM groups at different time points. Although there was significantly more forward movement after protraction in the Alt-RAMEC/FM group, the difference was deemed too small to be clinically relevant.

병렬팽창 냉동시스템의 성능실험에 관한 실험적 연구 (An Experimental Study on the Performance Testing of Parallel Expansion Refrigeration System)

  • 구창대
    • 한국산업융합학회 논문집
    • /
    • 제14권2호
    • /
    • pp.79-85
    • /
    • 2011
  • This study has been experimented about refrigeration capacity difference. It has been used 3 method, Manual expansion valve, thermostatic expansion valve and capillary expansion valve, and tested under the same condition by using the performance testing of parallel expansion. In temperature change of the temperature room, thermostatic expansion valve method displayed the most lower temperature, $-18^{\circ}C$. In addition, the temperature, just before the expansion, also displayed the best result which was $4^{\circ}C$ lower than other expansion valve. In these results, it can be used for performance testing of parallel expansion refrigeration system.

팽창재를 포함한 시멘트 모르터의 팽창 요인 (Expansion Factors of Cement Mortar Containing Expanding Admixture)

  • 황인동;염희남;정윤중
    • 한국세라믹학회지
    • /
    • 제37권6호
    • /
    • pp.576-582
    • /
    • 2000
  • Two type of expanding cement generally referred to as CSA with Hauyne(3CaO 3Al2O3 CaSO4) and Quick lime(CaO). Hauyne is formed to ettringite when there are presented with CaO and CaSO4, and CaO reacts wtih water to form Ca(OH)2. REcently, the mechanism of compensation and expand mortar or concrete tend to same and it has been used improving on its shrink property. The volume of cement paste varies with its water content shrink with drying and re-wetting. Concrete and mortar works are required shrinking compensation and expansion properties to reduce of potential crack. The use of expansion cement may improve on its shrinking volume changes. CSA dosages for shrinking compensation limited by cement weight, but obtained difference expansion rate with varied W/C or inorganic admixture. This paper studies expansion rate according to expansion cement dosages, water and inorganic admixtures as Silica fume. Therefor, the expansion factor has to considered before the application.

  • PDF

A Reversible Audio Watermarking Scheme

  • Kim, Hyoung-Joong;Sachnev, Vasiliy;Kim, Ki-Seob
    • 정보통신설비학회논문지
    • /
    • 제5권1호
    • /
    • pp.37-42
    • /
    • 2006
  • A reversible audio watermarking algorithm is presented in this paper. This algorithm transforms the audio signal with the integer wavelet transform first in order to enhance the correlation between neighbor audio samples. Audio signal has low correlation between neighbor samples, which makes it difficult to apply difference expansion scheme. Second, a novel difference expansion scheme is used to embed more data by reducing the size of location map. Therefore, the difference expansion scheme used in this paper theoretically secures high embedding capacity under low perceptual distortion. Experiments show that this scheme can hide large number of information bits and keeps high perceptual quality.

  • PDF