• Title/Summary/Keyword: Difference coefficient (D)

Search Result 327, Processing Time 0.028 seconds

Optimal Threshold Setting Method for R Wave Detection According to The Sampling Frequency of ECG Signals (심전도신호 샘플링 주파수에 따른 R파 검출 최적 문턱치 설정)

  • Cho, Ik-sung;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.7
    • /
    • pp.1420-1428
    • /
    • 2017
  • It is difficult to guarantee the reliability of the algorithm due to the difference of the sampling frequency among the various ECG databases used for the R wave detection in case of applying to different environments. In this study, we propose an optimal threshold setting method for R wave detection according to the sampling frequency of ECG signals. For this purpose, preprocessing process was performed using moving average and the squaring function based the derivative. The optimal value for the peak threshold was then detected according to the sampling frequency by changing the threshold value according to the variation of the signal and the previously detected peak value. The performance of R wave detection is evaluated by using 48 record of MIT-BIH arrhythmia database. When the optimal values of the differential section, window size, and threshold coefficient for the MIT-BIH sampling frequency of 360 Hz were 7, 8, and 6.6, respectively, the R wave detection rate was 99.758%.

The Depression in Middle-aged Women in Kwangwondo (일부지역 중년여성의 우울 정도와 영향 요인에 관한 연구)

  • Lee, Kyu-Eun;Choi, Euy-Soon
    • Women's Health Nursing
    • /
    • v.5 no.3
    • /
    • pp.299-312
    • /
    • 1999
  • The purpose of this study was to analyze the depression in middle-aged women. The subjects for this study were 246 middle-aged women in Kangwondo, the northeastern part of Korea. Data were collected from February 22 to April 24, 1999 by a structured questionnaire. The instruments for this study were CES-D (Radloff, 1977), somatic discomfort scale (Wittenborn, 1979), self-esteem scale (Rosenburg, 1971) and life satisfaction Index-Z (Wood et al. 1969). The data were analyzed by SAS/PC+ program using ANOVA, Pearson Correlation Coefficient. The results of the study were as follows : 1. Of 246 middle-aged women, 91 women (37%) revealed depression. The percentage of mild, moderate, severe depression were 17.78%, 11.28%, 7.72% respectively. 2. The statistically significant difference in the score of the depression according to the age (F=3.46, p=.0001)was obtained. 3. There were significant differences between depression and somatic discomfort (F=15.71, p=.0001). 4. The significant differences between depression and life satisfaction (F=23.89, p=.0001) was obtained. 5. The data shows the positive correlations between depression and somatic discomfort (r=.4856, p=.0001), between self-esteem and life-satisfaction(r=.2727, p=.0001), but we found negative correlations between depression and self-esteem(r=-4200, p=.0001), between depression and life-satisfaction(r=-.4409, p=.0001), between somatic discomfort and self-esteem(r=-.2275, p=.0015), between somatic discomfort and life-satisfaction(r=-.2695, p=.0002).

  • PDF

Effects of Cognitive Task on Stride Rate Variability by Walking Speeds (보행속도변화에 따른 인지 과제 수행이 보행수 변동성에 미치는 영향)

  • Choi, Jin-Seung;Yoo, Ji-Hye;Kim, Hyung-Shik;Chung, Soon-Cheol;Yi, Jeong-Han;Lee, Bong-Soo;Tack, Gye-Rae
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.323-331
    • /
    • 2006
  • The purpose of this study was to investigate the effect of performing a cognitive task during treadmill walking on the stride rate variability. Ten university students(age $24.0{\pm}0.25$, height $172{\pm}3.1cm$, weight $66{\pm}5.3kg$) were participated in dual task experiments which consist of both walking alone and walking with a cognitive task. Two-back task was selected for the cognitive task since it did not have learning effect during the experimental procedure.3D motion analysis system was used to measure subject's position data by changing walking speed with 4.8, 5.6, 6.4, 6.8, and 7.2 km/hr. Stride rate was calculated by the time between heel contact and heel contact. Accuracy rate of a cognitive task during walking, coefficient of variance, allometric scaling methods and Fano factor were used to estimated the stride rate variability. As the walking speed increased, accuracy rate decreased and the logarithmic value of Fano factor increased which showed the statistical difference. Thus it can be concluded that the gait control mechanism is distracted by the secondary attention focus which is the cognitive task ie. two-back task. Further study is needed to clarify this by increasing the number of subject and experiment time.

A Study on the Evaluation of Analytical Performance for Industrial Hygiene Laboratory in Korea (우리나라 작업환경측정기관 분석능력에 관한 고찰)

  • Park, D.W.;Shin, Y.C.;Lee, N.R.;Yi, G.Y.;Oh, S.M.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.2
    • /
    • pp.194-203
    • /
    • 1993
  • Quality Control programs for industrial hygiene laboratory have successfully been operated since the 1st round was initiated in April 1992. Three rounds have been completed. Overall analytical performance of participants was improved through a subsquent round. The first round had a large variation among analytical results of all participants, 26.34%~504.22% of coefficient of variation. But the variation of analytical performance in the 2nd and 3rd rounds decreased to 40.42%~52.55% and 10.74%~20.98%, respectively. The difference of analytical performance among participants was decreased by operation of subsquent round. By distribution of Running Performance Index (RPI), over 50% of participants belongs to Category 3 in the first round. The average percentage of participants assigned to Category 3 in the 2nd and 3rd round was decreased to 37.2%. A definite analytical performance improvement of participants seems to be obtained. "A" and "B" group have more participants assigned to Category 3 than those of "C" group through the distribution of RPI by group divided to similar participant. By the distribution of RPI all participants, the percent of participant being over 200 RPI in the 1st round was 43%~52%, but decreased to 9%~29% and 9%~27%, in the 2nd and 3rd round, respectively. These results mentioned above indicate that the analytical performance of all participants have been improved by subsquent Quality Control Program although newcomers joined and a few participants droped out. But, there are some participants with poor analytical performance. Industrial Health Research Institute (IHRI) will offer service such as education, communication and visitation to them, and improve quality of their analytical performance in the future.

  • PDF

A Study on the Analytical Errors of Non-proficient Laboratories Participated in Quality Control Program (작업환경측정기관의 정도관리를 통한 분석능력이 미흡한 기관들의 분석오차 유발요인에 관한 고찰)

  • Park, D.W.;Shin, Y.C.;Park, S.H.;Lee, N.R.;Oh, S.M.;Yoon, C.S.;Paik, N.W.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.96-102
    • /
    • 1994
  • Factors affecting non-proficient analytical ability were compared and evaluated by rating of laboratories and round. Analyst Indices between proficient and non-proficient participants were different. Coefficients of determination($R^2$) for standard of toluene, xylene and trichloroethylene of the 4th round between some proficient and non-proficient participants were significantly different(p<0.05). But, there was no difference in the 5th round. Average desorption efficiency of non-proficient participants was 88%-98%, which was lower than 96%-100% of some randomly selected proficient participants. Also non-proficient participants have a large variance of desorption efficiency, 11.79-19.69%. In the 5th round, desorption efficiency of metyl iso-butyl ketone(MIBK) reported by all participants was lower than 90% tested by NIOSH and especially low compared to other analytes. Participants evaluated to be non-proficient in the metal part have 85%-100.84% of average recovery, which was larger variance than 98% of some proficient participants. Although it is difficult to find quantitatively factors causing non-proficiency in analytical ability, pretreatement techniques and experience of analyst seems to be more important factors to produce accurate analytical result.

  • PDF

Comparison of LDL-Cholesterol direct measurement with the estimate using various formula

  • Kwon, Se Young;Na, Young-Ak
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.3
    • /
    • pp.103-111
    • /
    • 2012
  • Low-Density Lipoprotein cholesterol (LDLC) is the most important marker for the treatment of hyperlipidemia in NCEP-ATP III(National Cholesterol Education Program-Adult Treatment Panel III) guideline. Therefore, LDL cholesterol is pathologically meaningful, accurate measurement should be a top priority. Currently, LDLC is directly measured in most cases, but, the estimate is still used in mass health examination or screening test. This study is about the comparison of LDL-Cholesterol direct measurement with the estimate using various formula (Friedewald: [LDL-F=TC-HDL-TG/5], Nakajima: [LDL-N=TC-HDL-TG/4], Hattori: [LDL-H =0.94TC-0.94HDL-0.19TG], Puavilai: [LDL-P=TC-HDL-TG/6], Carvalho: [LDL-C=3(TC-HDL)/4]) for calculating more accurate value. We analyzed total cholesterol (TC), try-glyceride (TG), high-density lipoprotein cholesterol (HDLC), and LDLC levels of 210 subjects between June and November in 2011. Until now, the Friedewald formula is the most commonly used estimate for the LDLC. When Friedewald formula was applied, the correlation coefficient (r) was 0.940, showing high correlation. But, the result of the direct method was significantly different, compared with those of the Friedewald formula in triglyceride levels ${\geq}400mg/dL$(p<0.05). There was the highest correlation when we used LDL-P formula(r=0.947) in triglyceride levels <400 mg/dl. Also there was the lowest mean difference regardless of triglyceride level. Therefore, the study showed that TG/6 is more precise means of calculation than TG/5. On the other hand, the calculation of LDL-Cholesterol was underestimated, compared with direct measurement. It is necessary to have more data and modified Friedewald formula should be used for the accurate calculation.

  • PDF

Elasticity of the Funnel Ribs and Hydrodynamic Characteristics on the Sea Eel Pots (장어통발의 깔대기 탄성과 유체역학적 특성)

  • Kim, Yong-Hae;Ha, Jeong-Sik
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.4
    • /
    • pp.157-162
    • /
    • 1987
  • The basic experiments on the plastic sea eel pots used in fishing were carried out in order to investigate the elasticity of the funnel ribs, hydrodynamic resistance, sinking time and diffusion of the bait from June to October, 1987. The elasticity of the bamboo funnel ribs was higher than that of the polypropylene ribs up to the load 150g. The hydrodynamic resistance R (kg) of the pots towing to the head direction horizontally in relation to towing velocity V (m/sec) was expressed as following formula; R=0.36V super(2.01) and coefficient of drag C sub(D) was 0.52. The sinking times of the covered pots by tape fully or partially were late 1-2 second than the typical pots within the water depth 7.5m. The diffusion tendency through the covered pots using dye and sardine extracts solution was concentrated to the entrance more than the typical pots. However, fishing efficiency as number and weight of fish per pots for nine times fishing operation was revealed no difference between the covered pots and the typical pots.

  • PDF

The Availability of Energy and Protein, with Respect to Uric Acid, of Yellow-seeded Rapeseed Meal in Broiler Diets

  • Saki, A.A.;Mahmoudi, H.;Tabatabaei, M.M.;Ahmadi, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.11
    • /
    • pp.1624-1628
    • /
    • 2008
  • Experiments were conducted to evaluate the nutritional value of yellow-seeded rapeseed meal (YRSM). In the first experiment nutrient retention was recorded by 48 Arbor Acres-broiler chickens (28-d old) to determine AMEn (nitrogen-corrected apparent metabolizable energy), coefficient of apparent protein digestibility based on ileal digesta nitrogen, excreta nitrogen and uric acid nitrogen. The second experiment was carried out with 304 Arbor Acres-broiler chickens to compare effects of SBM (soybean meal) and YRSM on performance, carcass and digestive tract status. In the control treatment, SBM was replaced by graded levels of YRSM at 15, 22.5 and 30% of diet. Digestibility of YRSM protein was significantly lower (p<0.001) than SBM protein. The protein digestibility based on ileal measurement was significantly higher (p<0.001) than protein digestibility from excreta samples. There was no significant difference (p>0.001) between ileal and excreta digestibility of protein based on uric acid. AMEn as a fraction of gross energy was 0.54 in SBM and 0.45 in YRSM. With the exception of 30% YRSM, other YRSM treatments resulted in major effects on length and weight of the gastrointestinal tract. The results of this study have shown no adverse effect on performance as well as protein digestibility and energy value in response to replacement of SBM by YRSM with the exception of 22.5 and 30% YRSM.

Clinical Study on the Floating and Sinking Pulse Detection with Piezoresistive Sensors and Contact Pressure Control Robot (압저항 센서와 가압조절 로봇을 이용한 부침맥 검출에 관한 임상연구)

  • Lee Si-Woo;Lee Yu-Jung;Lee Hae-Jung;Kang Hee-Jung;Kim Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.6
    • /
    • pp.1673-1675
    • /
    • 2005
  • The pulse diagnosis is an important and universal method in Oriental medicine. Nevertheless, because of characteristic that depends on subjective sense of Oriental medicine doctor (OMD), it is not recognized by objective basis. The Korean Institute of Oriental Medicine(KIOM) and Daeyo Medi. Co. Ltd. developed the 3-D Mac using arrey piezoresistive sensors and multi-axial robot. 133 healthy subjects participated in this study, 75 males and 58 females, between 20 and 70 years of age. All subjects were relaxed in a supine position on a comfortable chair for twenty minutes before the measurement was taken. The measured position is the radial artery of subject's left wrist and the position is called Chon, Kwan and Chuck in Oriental medicine. To detect floating and sinking pulse, we established coefficient of floating and sinking(CFS). CFS means relative position of maximum pulse pressure in PH curve. The lower CFS value means that the pulse has floating tendency. There was significant diffence between CFS and diagnosis of floating-sinking pulse by OMD(p=0.020). CFS value of over 40's group was significantly larger than those of 20's and 30's(p=0.000). There was no significant difference between male and female(p=0.061).

Influence of Current Density Application Time on the Corrosion Damage of Offshore Wind Steel Substructure in Galvanostatic Corrosion Experiment (해상풍력 하부 구조물용 강재의 정전류 부식 시험 시 전류밀도 인가 시간이 부식손상에 미치는 영향)

  • Lee, Jung-Hyung;Park, Jae-Cheul;Han, Min-Su;Jang, Seok-Ki;Kim, Seong-Jong
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.5
    • /
    • pp.431-438
    • /
    • 2016
  • This research investigated the relationship between the corrosion damage characteristics of offshore wind steel substructure and the time of current density application by electrochemical accelerated short-term corrosion test. The galvanostatic corrosion was conducted on the steel specimens in natural seawater with a constant current density ranging from $1mA/cm^2$ to $200mA/cm^2$ for 1 ~ 180 min. Macro and micro observation was carried out on the surface of the corrosion damaged area using SEM and 3-dimensional analysis microscope. The weight loss of the specimens before and after was calculated as the difference between the initial weight prior to corrosion and weight after removal of the corrosion product. It was shown that during galvanostaic corrosion process, the corrosion behavior could be characterized by the onset of pitting corrosion in the early stage and the uniform corrosion in the late stage, showing damage development in the depth direction with the time of current application. The result of the 3D analysis revealed that both damage depth and surface roughness increased with increasing time of current application. The weight loss curves with time showed that a coefficient of determination ($R^2$) was relatively high for the relationship between the time of current application and weight loss. As a result, the degree of corrosion can be controlled by simply varying the time of current application.