• Title/Summary/Keyword: Difference Values

Search Result 6,830, Processing Time 0.033 seconds

An Efficient Multi-level Successive Elimination Algorithm using the Locality in Block (동영상의 블록내 지역성을 이용하는 효율적인 다단계 연속 제거알고리즘)

  • Jung, Soo Mok
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.4
    • /
    • pp.179-187
    • /
    • 2009
  • In this paper, an efficient multi-level successive elimination algorithm using the locality in block was proposed for motion estimation. If SAD(sum of absolute difference) is calculated from large absolute difference values to small absolute difference values, SAD is increased rapidly. So, partial distortion elimination in SAD calculation can be done very early. Hence, the computations of SAD calculation can be reduced. In this paper, an efficient algorithm to calculate SAD from large absolute difference values to small absolute difference values by using the locality in block. Experimental results show that the proposed algorithm is an efficient algorithm with 100% motion estimation accuracy for the motion estimation of motion vectors.

Acoustic Features of Oral Vowels in the Esophagus Speakers (식도음성의 모음종류에 따른 음향학적 특성)

  • Yun, Eunmi;Mok, Eunhee;Minh, Phan huu Ngoc;Hong, Kihwan
    • Phonetics and Speech Sciences
    • /
    • v.7 no.4
    • /
    • pp.85-92
    • /
    • 2015
  • This study aimed to establish characteristics related to voice and speech through the natural base frequency analysis of esophagus vocalization. In the study, 8 subjects were selected for esophagus vocals, and 10 other subjects were selected for a control group. MDVP(Multi-dimensional Voice Program, Model 4800, USA, 2001), Multi Speech(Model 3700, Kaypantax, USA, 2008) were used as experiment equipment. The speech samples selected for evaluation were vowels and sentences (both declarative and interrogative). For acoustic analysis, the intonation form of fo, jitter, energy, shimmer, HNR, and intonation patterns of the speech sample were measured. The results were as follows: First, the natural intrinsic frequency of extended vowels in the esophagus vocal group was lower than the frequency in the normal vocal group. In particular, the intrinsic frequency difference for high vowel /i/ was much greater than the frequency difference for low vowel /a/. Second, the jitter values of the esophagus vocal group were higher than the control group. In particular, there was a large difference between the jitter values for /a/ and /i/, with the jitter values being highest for /i/. Third, there was no significant difference in vocal strength between the esophagus vocal patient group and the control group. Fourth, the shimmer values of the voices in the esophagus vocal group were higher than shimmer values in the control group. In particular, there was a large difference in shimmer values for low vowel /a/. Fifth, the HNR values of the esophagus vocal group were showed significantly lower than the control group. In particular, the largest difference in HNR values between the two groups was for high vowel /i/. Sixth, the pitch contours of interrogative and declarative sentences of the esophagus vocal patient group showed a different form or only had with small differences compared to the pitch contours of the normal vocal group, thus presenting an inconsistent pattern.

A comparative study on the accuracy of the devices for measuring the implant stability

  • Cho, In-Ho;Lee, Young-Il;Kim, Young-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.3
    • /
    • pp.124-128
    • /
    • 2009
  • STATEMENT OF PROBLEM. How the ISQ values measured by $Osstell^{TM}$ and $Osstell^{TM}$ Mentor are related, and whether the ISQ values acquired from the two machines changes in accordance with changes in implant stability are not yet fully understood. PURPOSE. The aim of this study was to find out correlation between the ISQ values acquired from $Osstell^{TM}$ and $Osstell^{TM}$ Mentor, and to evaluate the clinical effectiveness and accuracy of two devices. MATERIAL AND METHODS. Sixty two implants were inserted into 47 patients, and their ISQ values were measured using $Osstell^{TM}$ and $Osstell^{TM}$ Mentor. In the first stage surgery, the ISQ values of forty four implants inserted into thirty five patients were measured. In the second stage surgery, the values of fifty implants inserted into thirty seven patients were measured. The values were analyzed to determine the difference between the mean ISQ values of $Osstell^{TM}$ and $Osstell^{TM}$ Mentor. In addition, the correlation between implants used in the first and second stage of surgery with regard to their types and areas of insertion were analyzed. The difference between the ISQ values of 32 implants in each patient during the first and second stage was analyzed. The statistical assessment was carried out using SPSS V. 12.0 for Win. (SPSS Inc., Chicago, USA). The Pearson correlation coefficient was used to examine the correlation between $Osstell^{TM}$ and $Osstell^{TM}$ Mentor in the first and second stages of surgery, whereas the difference between their ISQ values was evaluated using a paired t-test. RESULTS. In the first stage, the mean ISQ value for $Osstell^{TM}$ and $Osstell^{TM}$ Mentor was 70.84 and 75.09, respectively, showing a significant difference (P < .01). In the second stage, the mean ISQ value of $Osstell^{TM}$ and $Osstell^{TM}$ Mentor was 71.76 and 75.94, respectively, also showing a significant difference (P < .01). The difference between the ISQ values in patients in the first and the second stages was significant with both instruments. CONCLUSION. The significant difference in the values obtained using the $Osstell^{TM}$ and $Osstell^{TM}$ Mentor between the first and second stages of implant surgery indicates that these values can be a convenient and precise way for evaluating the implant stability in clinical practice.

Automatic Threshold-decision Algorithm using the Average and Standard Deviation (평균과 표준편차를 이용한 자동 임계치-결정 알고리즘)

  • Ko, Kyong-Cheol;Rhee, Yang-Won
    • The Journal of Korean Association of Computer Education
    • /
    • v.8 no.6
    • /
    • pp.103-111
    • /
    • 2005
  • This paper presents a novel automated threshold-decision algorithm that uses the mean and standard-deviation values obtained from the difference values of consecutive frames. At first, the calculation of difference values is obtained by the weighted ${\chi}^2$-test algorithm which was modified by joining color histogram to ${\chi}^2$-test algorithm. The weighted ${\chi}^2$-test algorithm can subdivide the difference values by imposing weights according to NTSC standard. In the first step, the proposed automatic threshold-decision algorithm calculates the mean and standard-deviation value from the total difference values, and then subtracts the mean value from the each difference values. In the next step, the same process is performed on the remained difference values, and lastly, the threshold is detected from the mean when the standard deviation has a maximum value. The proposed method is tested on various video sources and, in the experimental results, it is shown that the proposed method efficiently estimates the thresholds and reliably detects scene changes.

  • PDF

Development of Method for Deciding Automatically Parameters of Water Quality Simulation Models (수질모형의 매개변수 자동보정 프로그램 개발에 관한 연구)

  • Song, Kwang-Duck;Paik, Do Hyeon;Lee, Yong Woon
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.2
    • /
    • pp.101-109
    • /
    • 2006
  • Water quality simulation models include the difference between the measured and estimated values as an inevitable consequence because they represent the complicated natural phenomena as simplified mathematical equations. The major reason of the difference occurrence is due to the use of the imprecise values of the model parameters, but the parameter values are currently determined by the try and error method directly performed by humans. However, the use of this method requires many time and endeavor of humans, and generally does not obtain the most suitable parameter values. A method for deciding model parameter values is, therefore, developed in this study. The method minimizes the difference between the measured and estimated values and also distributes uniformly the measured values on the upper and lower sides of the line representing the estimated values. A user interface based on this method is also developed by using the Visual Basic 6.0 of Microsoft, and it can be operated in the environment of Windows 98/2000. In this study, the method for deciding model parameter values is applied for estimating the water quality of the stream Ko-heung. The results of the application show that the method, including its computer program, can effectively obtain the most suitable parameter values and also save many working time in comparison with the existing method directly performed by humans.

Effects of White Noises on Gait Ability of Hemiplegic Patients during Circuit Balance Training

  • Jang, Na-Young;Kim, Gi-Do;Kim, Bo-Kyoung;Kim, Eun-Hee;Koo, Ja-Pung;Shin, Hee-Joon;Choi, Seok-Joo;Choi, Wan-Suk
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.3 no.1
    • /
    • pp.370-377
    • /
    • 2012
  • This study examines the effects of different environments on the application of hemiplegia patients circuit balance training. Group 1 performed circuit balance training without any auditory intervention Group 2 performed training in noiseless environments and Group 3 performed training in white noise environments. First, among lower extremity muscular strength evaluation items, maximum activity time(MAT) was not significantly different(p>.05). Maximum muscle strength(MMS) increased significantly in Group 3(p<.01), there was no significant difference in MMS among the groups. Average muscle strength(AMS) indexes also significantly increased in Group 3(p<.01), there was no significant difference in AMS among the groups. Second, among balancing ability evaluation items, Berg's balance scale(BBS) scores significantly increased in all groups(p<.05), BBS scores were significantly difference among the groups. Based on the results, Group 1, 2 and Group 1, 3 showed significant increases (p<.05). Functional reach test(FRT) values significantly increased in Group 2, 3(p<.05), and there was no significant difference in FRT values among the groups. Timed up and go(TUG) test values significantly decreased in Group 2, 3(p<.05), and there was no significant difference in TUG test values among the groups. Third, among walking speed evaluation items, the time required to walk 10m significantly decreased in all groups(p<.05), and there was no significant difference in the values among the groups. Average walking speeds showed significant increases in Group 1, 3(p<.05), and there was no significant difference in the values among the groups. Based on the results of this study, noise environments should be improved by either considering auditory interventions and noiseless environments, or by ensuring that white noise environments facilitate the enhancement of balancing ability.

UNIQUENESS OF A MEROMORPHIC FUNCTION WITH DIFFERENCE POLYNOMIAL OF DIFFERENCE OPERATOR SHARING TWO VALUES CM

  • H. R. Jayarama;H. Harish;S. H. Naveenkumar;C. N. Chaithra
    • Honam Mathematical Journal
    • /
    • v.46 no.2
    • /
    • pp.267-278
    • /
    • 2024
  • In this paper, we investigate the uniqueness of a meromorphic function f(z) and its difference polynomial of difference operator with two sharing values counting multiplicities. Our two results improve and generalize the recent results of Barki Mahesh, Dyavanal Renukadevi S and Bhoosnurmath Subhas S [4] and for the case q ≥ 2, this allows for a highly unique generalization. To further demonstrate the validity of our main result, we provide an example.

Comparative Analysis of Morphometric Characteristics of Scorpaenidae and Gobioninae

  • Park, In-Seok;Gil, Hyun Woo;Oh, Ji Su;Choi, Hui Jung;Kim, Chi Hong
    • Development and Reproduction
    • /
    • v.19 no.2
    • /
    • pp.85-96
    • /
    • 2015
  • Measurements of closely related sets of classical and truss dimensions were analyzed to discriminate species of scorpaenidae including the dark banded rockfish, Sebastes inermis, the black rockfish, S. schlegeli, and gobioninae including the striped shiner, Pungtungia herzi, and the slender shiner, Pseudopungtungia tenuicorpa. The measurements of the dimensions were arc sin square root transformed, and compared as a function of the standard length of each species for statistical analysis. For values of the classical dimensions of the rockfish, 6 were greater for the dark banded rockfish than for the black rockfish, 1 value was smaller for the former, and for 2 values there was no statistically significant difference (P > 0.05). For values of the classical dimensions of the shiners, 9 values were greater for the striped shiner than for the slender shiner, 2 values were smaller for the former, and for 1 value there was no statistically significant difference (P > 0.01). For values of the truss dimensions of the rockfish, 6 were greater for the dark banded rockfish than for the black rockfish, 1 was smaller for the former, and for 4 values there was no statistically significant difference (P > 0.05). For values of the truss dimensions of the shiners, 13 values were greater for the striped shiner than for the slender shiner, 3 values were smaller for the former, and for 6 values there was no statistically significant difference (P > 0.01). The dimension sets used in this study may be useful as taxonomic indicators for discriminating among fish species in Korea.

Effect of Moxibution at the Kwanwon, Chung-wan and Chok-samni on the blood picture in Rat with transportation stress (관원(關元).중완(中脘).족삼리(足三里) 애구(艾灸)가 수송(輸送) Stress를 준 Rat의 혈액상(血液狀)에 미치는 영향(影響))

  • Yang, Seung-Hee;Lee, Joon-Moo
    • The Journal of Internal Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.165-175
    • /
    • 1994
  • Effects of moxibution at the Gwanweon, Jungwan and Joksamlee on the blood picture in rat with transportation stress were determined. Counts of RBC showed a tendency to increase from 6 hours to 12 hours after transportation stress, however in the moxibution group, showed no changes in counts of RBC after transportation stress and the tendency of fluctuation was similiar to those of none stress group. The changes in Hb after transportation stress showed no difference among moxibution group and none moxibution group, however the changes in PCV showed a tendency to increase from 3 hours to 6 hours after transportation stress in two stress group. In the mean values of erythrocytic blood during experimental times, counts of RBC showed a high values (P<.05) in the stress only group, however in the other groups, these values showed no difference (P>.05) among treatment and the values of Hb and PCV showed no difference among 4 treatment groups. In the two stress groups, counts of WBC and Neutrophils showed a tendency to decrease after transportation stress, however the moxibution group was recovered to normal Leukocytes condition on short time compared with those of none moxibution group. In the mean values of Leukocytes during experimental times, counts of WBC and Neutrophils showed a high values and Lymphocytes showed a low values in the stress only group compared with those of other groups, however the stress group with moxibution showed no difference in Leukocytes values compared with those of normal condition group. Monocytes, Basophils and Eosinophils showed no difference among 4 treatment groups(P>.05). Results from this study indicate that the moxibution can tolerate the effects of transportation stress in rat.

  • PDF

Effects of inclusion level and amino acid supplementation on energy values of soybean oil determined with difference or regression methods in growing pigs

  • Wang, Qiuyun;Huang, Chengfei;Liu, Mei;Liu, Ling;Zhang, Shuai
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.11
    • /
    • pp.1809-1816
    • /
    • 2020
  • Objective: This study was conducted to evaluate the effects of inclusion level and amino acid (AA) supplementation on energy values of soybean oil (SO) as determined by difference method or regression method when fed to growing pigs. Methods: Thirty-six barrows (initial body weight: 28.0±1.3 kg) were randomly assigned to one of 6 dietary treatments, which included 2 control diets formulated using a basal diet with or without AA supplementation, and 4 experimental diets with 5% or 10% SO addition in the 2 control diets, respectively. All pigs were individually housed in metabolism crates for 19 d, and during the last 5 d, total urine and feces production were collected. The nutrient digestibility in diets and the digestible energy (DE) and metabolizable energy (ME) values of SO were determined using the difference method and the regression method, respectively. Results: Our results showed that there were no interaction effects (p>0.05) between AA supplementation and SO inclusion levels on energy values of SO and dietary nutrient digestibility. The DE and ME values of SO determined by the difference method were not affected (p>0.05) by AA supplementation, however, the ME value of SO increased (p<0.05) as the inclusion level of SO increased. Moreover, the energy values of SO determined using the regression method were close to those determined using difference method with 10% SO inclusion, but were greater than those obtained using difference method with 5% SO inclusion. Conclusion: We concluded that the DE and ME values of SO increased with the inclusion level but were not affected by AA supplementation in the range of 0% to 10%. The difference method can substitute for the regression method to determine the DE and ME values of SO when the inclusion level is 10%, but not at 5% inclusion level.