• Title/Summary/Keyword: Diff

Search Result 327, Processing Time 0.026 seconds

Comparison treatment planning with the measured change the dose of each Junction section according to the error of setup CSI Treatment with Conventional, IMRT, VMAT (Conventional, IMRT, VMAT을 이용한 CSI 치료시, Setup 오차에 따른 각 Junction부의 선량변화측정을 통한 치료계획 비교)

  • Lee, Ho Jin;Jeon, Chang Woo;Ahn, Bum Suk;Yu, Sook Hyeon;Park, So Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.217-224
    • /
    • 2014
  • Purpose : Conventional, IMRT, at CSI treatment with VMAT, this study compare the treatment plan with dose changes measured at Junction field according to the error of Setup. Materials and Methods : This study established Conventional, the IMRT, VMAT treatment planning for CSI therapy using the Eclipse 10.0 (Eclipse10.0, Varian, USA) and chose person in Seoul National University Hospital. Verification plan was also created to apply IMRT QA phantom for each treatment plan to the film measurements. At this time, the error of Setup was applied to the 2, 4, 6mm respectively with the head and foot direction. ("+" direction of the head, "-" means that the foot direction.) Using IMRT QA Phantom and EBT2 film, was investigated by placing the error of Setup for each Junction. We check the consistency of the measured Film and plan dose distribution by gamma index (Gamma index, ${\gamma}$). In addition, we compared the error of Setup by the dose distribution, and analyzing the uniformity of the dose distribution within the target by calculating the Homogeneity Index (HI). Results : It was figured out that 90.49%-gamma index we obtained with film is agreement with film scan score and dose distribution of treatment plan. Also, depend on the dose distribution on distance, if we make the error of Setup 2, 4, 6mm in the head direction, it showed that 3.1, 4.5, 8.1 at $^*Diff$(%) of Conventional, 1.1, 3.5, 6.3 at IMRT, and 1.6, 2.5, 5.7 at VMAT. In the same way, if we make the error of Setup 2, 4, 6mm in the foot direction, it showed that -1.6, -2.8, -4.4 at $^*Diff$(%) of Conventional, -0.9, -1.6, -2.9 at IMRT, and -0.5, -2.2, -2.5 at VMAT. Homogeneity Index(HI)s are 1.216 at Conventional, 1.095 at IMRT and 1.069 at VMAT. Discussion and Conclusion : The dose-change depend on the error of Setup at the CSI RT(radiation therapy) using IMRT and VMAT which have advantages, Dose homogeneity and the gradual dose gradients on the Junction part is lower than that of Conventional CSI RT. This a little change of dose means that there is less danger on patients despite of the error of Setup generated at the CSI RT.

Une étude pour la critique de théâtre avec la sémiotique ouverte -avec par Jean Genet- (열린 기호학을 활용한 연극비평 연구 -장 주네의 <하녀들> 공연을 중심으로-)

  • LIM, Seon-Ok
    • Journal of Korean Theatre Studies Association
    • /
    • no.40
    • /
    • pp.239-275
    • /
    • 2010
  • Cette ${\acute{e}}tude$ a pour but de proposer une $m{\acute{e}}thodologie$ de critique avec la $s{\acute{e}}miotique$ ouverte. La critique de $th{\acute{e}}{\hat{a}}tre$ commence ${\grave{a}}$ lire le $th{\acute{e}}{\hat{a}}tre$, l'analyse et juge son valeur. Il arrive souvent qu'on juge avec intutition. On dit que c'est une critique d'impressionnisme. Cette critique est subjective, mais pas objective. La $s{\acute{e}}miotique$ de Saussure offre la $m{\acute{e}}thodologie$ scientifique ${\grave{a}}$ la critique. A $c{\hat{o}}t{\acute{e}}$ de la critique d'impressionnisme qui est subjective, la $s{\acute{e}}miotique$ peut expliciter la raison objective. On ${\acute{e}}tait$ admiratif devant sa scientisme, pourtant $apr{\grave{e}}s$ quoi on critique sa non-$subjectivit{\acute{e}}$ et sa non-$historicit{\acute{e}}$. Dans l'opposition de $l^{\prime}objectivit{\acute{e}}$ et de la $subjectivit{\acute{e}}$, on tente de rechercher un model $int{\acute{e}}gr{\acute{e}}$ dialectiquement entre l'impressionisme(subjective) et la scientisme(objective). Pour cela, on doit aux Ecrits de linguistique $g{\acute{e}}n{\acute{e}}rale$ ($publi{\acute{e}}$ en 2002 chez Gallimard). Ces Ecrits nous aident ${\grave{a}}$ amener la $s{\acute{e}}miotique$ $ferm{\acute{e}}e$ sur la $s{\acute{e}}miotique$ ouverte et ${\grave{a}}$ $red{\acute{e}}couvrir$ la $pens{\acute{e}}e$ de Saussure. Ils nous font ouvrir un nouveau champ de recherche pour la $s{\acute{e}}miotique$ ouverte. L'essentiel de la $th{\acute{e}}orie$ saussurienne du signe $d{\acute{e}}pend$ de l'arbitraire et du circulaire du signe. On $red{\acute{e}}couvre$ la notion ${\acute{e}}largie$ du signe, dans Ecrits de linguistique $g{\acute{e}}n{\acute{e}}rale$, contre le courant majeur de linguistique et de structuralisme. Cette notion s'y focalise, ${\grave{a}}$ la valeur, ${\grave{a}}$ la $relativit{\acute{e}}$, ${\grave{a}}$ la $diff{\acute{e}}rence$ et au $syst{\grave{e}}me$. Avec elle, on tente d'adopter la $s{\acute{e}}miotique$ ouverte pour rechercher une $m{\acute{e}}thodologie$ de critique qui se veut objective et ${\grave{a}}$ la fois subjective. Il s'agit d'une difficile combinaison de l'impressionisme et de la scienticisme. Pour cela, la $m{\acute{e}}thodologie$ se $d{\acute{e}}veloppera$ en trois ${\acute{e}}tapes$. $1{\grave{e}}re$ ${\acute{e}}tape$: c'est lire le $th{\acute{e}}{\hat{a}}tre$ comme un signe total pour 1er jugement d'impressionnisme. $2{\grave{e}}me$ ${\acute{e}}tape$: c'est retrouver sa structure invisible dans la $relativit{\acute{e}}$ des signes. $3{\grave{e}}me$ ${\acute{e}}tape$: c'est juger, dans leur $relativit{\acute{e}}$, comment les $d{\acute{e}}tails$ de signes se fonctionnent. C'est lire les $d{\acute{e}}tails$ de signes et puis $r{\acute{e}}affirmer$ le jugement en $1{\grave{e}}re$ ${\acute{e}}tape$. Selon les $derni{\grave{e}}res$ deux ${\acute{e}}tapes$, on pourra comparer le premier jugement (impressif) et le dernier jugement (objectif), et enfin s'assumer comme critique. Selon la $m{\acute{e}}thodologie$ $propos{\acute{e}}e$, on pratique la critique sur ${\acute{e}}crit$ par Jean Genet, et mise en $sc{\grave{e}}ne$ par Lee Youn-Taek et par Park Jung-Hee. Pour la critique intertextuelle, on la fera en comparant les deux spectacles avec la $pi{\grave{e}}ce$ de Jean Genet. $D^{\prime}apr{\grave{e}}s$ la comparaison, Lee Youn-Taek met en $sc{\grave{e}}ne$ avec $fid{\acute{e}}lit{\acute{e}}$ la structre et les signes de $d{\acute{e}}tail$ de l'auteur, Park Jung-Hee change sa structre et ses signes pour mettre en $sc{\grave{e}}ne$ la $pi{\grave{e}}ce$ de Genet. Ils se $diff{\grave{e}}rent$ l'un et l'autre: Lee incite le discours de la classe sociale dans le spectacle, et Park y incite le discours du $d{\acute{e}}sir$. La $diff{\acute{e}}rence$ des signes dans la $relativit{\acute{e}}$ apporte la $diff{\acute{e}}rence$ de la signification de discours $th{\acute{e}}{\hat{a}}tral$, et enfin se font changer les significations de deux spectacles.

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

Performance Management and Analysis for Guaranteed End-to-End QoS Provisioning on MPLS-based Virtual Private LAN Service(VPLS)

  • Kim, Seong-Woo;Kim, Chul;Kim, Young-Tak
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.2B
    • /
    • pp.144-156
    • /
    • 2003
  • Internet/Intranet has been continuously enhanced by new emerging IP technologies such as differentiate service(DiffServ), IPSec(IP Security) and MPLS(Multi-protocol Label Switching) traffic engineering. According to the increased demands of various real-time multimedia services, ISP(Internet Service Provider) should provide enhanced end-to-end QoS(quality of service) and security features. Therefore, Internet and Intranet need the management functionality of sophisticated traffic engineering functions. In this paper, we design and implement the performance management functionality for the guaranteed end-to-end QoS provisioning on MPLS-based VPLS(Virtual Private LAN Service). We propose VPLS OAM(Operation, Administration and Maintenance) for efficient performance management. We focus on a scheme of QoS management and measurement of QoS parameters(such as delay, jitter, loss, etc.) using VPLS OAM functions. The proposed performance management system also supports performance tuning to enhance the provided QoS by re-adjusting the bandwidth of LSPs for VPLS. We present the experimental results of performance monitoring and analysis using a network simulator.

Rule set of object-oriented classification using Landsat imagery in Donganh, Hanoi, Vietnam

  • Thu, Trinh Thi Hoai;Lan, Pham Thi;Ai, Tong Thi Huyen
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.6_2
    • /
    • pp.521-527
    • /
    • 2013
  • Rule set is an important step which impacts significantly on accuracy of object-oriented classification result. Therefore, this paper proposes a rule set to extract land cover from Landsat Thematic Mapper (TM) imagery acquired in Donganh, Hanoi, Vietnam. The rules were generated to distinguish five classes, namely river, pond, residential areas, vegetation and paddy. These classes were classified not only based on spectral characteristics of features, but also indices of water, soil, vegetation, and urban. The study selected five indices, including largest difference index max.diff; length/width; hue, saturation and intensity (HSI); normalized difference vegetation index (NDVI) and ratio vegetation index (RVI) based on membership functions of objects. Overall accuracy of classification result is 0.84% as the rule set is used in classification process.

A modified RIO for Improving Assured Service Performance (대역폭 보장 서비스를 위한 개선된 RIO 알고리듬)

  • Kim, Hyo-Gon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.11S
    • /
    • pp.3320-3331
    • /
    • 1999
  • In this paper, we explore two ways to improve the bandwidth assurance performance of Assured Service(AS). It is well known that AS fails to meet the bandwidth assurance target for large-profile TCP flows competing with many small-profile flows. This flows after the back-offs induced by packet drops. Thus currently proposed solution to this problem naturally focus on modifying TCP's behavior to counter the unfairness in the TCP dynamics. Unfortunately, these proposals lack practicability in terms of the required changes in the incumbent Internet infrastructure. Admitting this difficulty, we instead look to not yet deployed Diff-Serv mechanisms for practical solutions. In particular, we investigate the role of RIO, RED with IN(in-profile) and OUT(out-profile), queue management scheme in the assurance failure for As. Specifically, we identify the inadequacy of RIO that aggravates the bandwidth assurance failure. Then we alleviates the bandwidth assurance failure problem by separately controlling the out-of-profile packet queue length. Through extensive simulations we demonstrate that RI+O extends the regime where AS consistently provides the bandwidth assurance.

  • PDF

Multiple Virtual Networking on IP/MPLS Network for QoS-guaranteed DiffServ provisioning (QoS 보장형 차별화 서비스 제공을 위한 IP/MPLS 망에서의 Multiple Virtual Network 구성)

  • 김해선;김영탁
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10c
    • /
    • pp.547-549
    • /
    • 2004
  • 본 논문에서는 IP/MPLS 망에서 QoS 보장형 차별화 서비스 제공을 위한 Virtual Networking 구조를 제안한다. 제안한 구조에서는 멀티미디어 단말장치와 PE(Provider Edge) 사이에서 RSVP-TE를 이용한 signalling을 통해 연결설정을 요청하고 PE에서 CAC(Call Admission Control)가 이루어질 수 있도록 한다. 또한 provider network에서 일반 가입자에게 QoS 보장형 차별화 서비스를 제공해줄 수 있도록 Multiple Virtual Network을 구성하며, class-type별로 차별화된 virtual network을 구성하기 위해서 L-LSP를 PE간에 full-mesh 형태로 설정한다 본 논문에서 제안한 Virtual Networking을 통하며 망 사업자는 보다 효율적으로 망을 관리하며, 통신망 자원의 이용율을 극대화시키고 사용자들에게 QoS 보장형 차별화 서비스를 제공해주는 것이 가능하다.

  • PDF

Differentiated Quality of Service Model in the Internet (인터넷에서의 차별화된 서비스품질 제공 방안)

  • Kim, Dong-Chul;Jang, Hee-Seon
    • IE interfaces
    • /
    • v.23 no.2
    • /
    • pp.193-202
    • /
    • 2010
  • The quality of service(QoS) model should be presented with the optimal network design to effectively provide the multimedia data services between users and converged services with mobile or TV in the next-generation Internet. In specific, the method to provide differentiated services for each user is needed in the given Internet node to offer the previously negotiated QoS with the user. In this paper, the performance of the QoS enabling technologies in the differentiated services(DiffServ) network domain is analyzed. The QoS offering model and QoS metrics are presented to analyze the performance of the major scheduling algorithms. Under the real network topology and virtual service scenarios in the university, the NS-2 network simulation based on the discrete-event is performed. The results show that the ratio-based scheduling method is more effective rather than the bandwidth-assignment method.

Design and Implementation of MPLS based VPN with DiffServ Capabilities (차별화 된 서비스를 제공하는 MPLS 기반의 VPN 구조 설계 및 구현)

  • 오홍석;오영선;이현태
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2003.11a
    • /
    • pp.227-233
    • /
    • 2003
  • In paper, we present design and implementation of MPLS based VPN with QoS capabilities. We propose a design architecture of an edge router for MPLS based VPN with QoS capabilities in backbone network. We design functional blocks, interface specifications, detail routing and forwarding information based structure, and packet forwarding engine for the purpose of implementation of an edge router, We extend bgp-4 software for implementation differentiated service packet forwarding schemes in MPLS based VPN.

  • PDF

Network Management Model for QoS-enabled Internet (QoS 인터넷 망에서의 망관리 모델)

  • 권영미;이극
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2002.11b
    • /
    • pp.549-552
    • /
    • 2002
  • 복잡하고 거대한 통신망을 효율적으로 구성하고 운용 관리하기 위해 ITU-T에서는 TMN 망관리 국제표준을 정하고 있다. 그러나 TCP/IP 기반의 인터넷 망에서는 TMN보다 간단하게 정의되어 있는 SNMP를 이용해 MIB를 기반으로 망 요소(network element) 제어만을 하고 있다. 인터넷 망에서 멀티미디어 데이터 교환 서비스를 수용하면서, IP 망 설계 초기에 고려하지 않았던 서비스품질(QoS)을 제공하기 위해 IntServ, DiffServ 프로토콜 등을 정의하고 있다. 이렇게 QoS를 제공하기 위한 인터넷 망은 단순한 SNMP 만으로는 관리될 수 없다. 그러나 아직까지 이에 적합한 망관리 모델이 정립되지 못한 상태인 바, 본 논문에서는 정책을 기반(policy-based)으로 하여 QoS 서비스를 위한 자원 할당을 dynamic하게 제공할 수 있도록 하는 QoS 인터넷 망관리 모델을 제안한다. 이 모델은 TMN의 관리계층 구조에 맞도록 구성되어 있다.

  • PDF