• Title/Summary/Keyword: Dielectrophoresis (DEP)

Search Result 24, Processing Time 0.027 seconds

ZnO NW-based ultraviolet photodiodes fabricated by dielectrophoresis technique (교류 전기장 배열 기법에 의해 제작된 ZnO 나노선 기반의 자외선 광다이오드)

  • Kim, Kwang-Eun;Kang, Jeong-Min;Lee, Myeong-Won;Yoon, Chang-Joon;Jeon, Young-In;Kim, Sang-Sig
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.259-259
    • /
    • 2010
  • 교류 전기장에 의해 배열된 ZnO 나노선 기반의 광다이오드를 제작하고 자외선 광특성을 조사하였다. ZnO 나노선은 dielectrophoresis (DEP) force와 토크 (T)에 의하여 두 전극사이에 배열되며, silicon (Si)나노선과 접합을 하여 p-n 접합을 형성한다. 형성된 p-n 접합은 정류작용을 하는 다이오드 특성을 보이며, 자외선 입사시 전류 점멸비 (on/off ratio) $10^1{\sim}10^2$을 보이는 광다이오드(photodiode)로서 동작한다.

  • PDF

A p-n Heterojunction Diode Constructed with A p-Si Nanowire and An n-ZnO Nanoparticle Thin-Film by Dielectrophoresis (Dielectrophoresis 방법으로 제작한 Si 나노선과 ZnO 나노입자 필름 기반 p-n 이종접합 다이오드)

  • Kim, Kwang-Eun;Lee, Myeong-Won;Yun, Jung-Gwon;Kim, Sang-Sig
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.105-108
    • /
    • 2011
  • Newly-developed fabrication of a p-n heterojunction diode constructed with a p-Si nanowire (NW) and an n-ZnO nanoparticle (NP) thin-film by the dielectrophoresis (DEP) technique is demonstrated in this study. With the bias of 20 Vp-p at the input frequency of 1 MHz, the most efficient assembly of the n-ZnO NPs is shown for the fabrication of the p-n heterojunction diode with a p-Si NW. The p-n heterojunction diode fabricated in this study represents current rectifying characteristics with the turn on voltage of 1.1 V. The diode can be applied to the fabrication of optoelectrical devices such as photodetectors, light-emitting diodes (LEDs), or solar cells based on the high conductivity of the NW and the high surface to volume ratio of the NP thin film.

Analysis of Particle Motion in Quadrupole Dielectrophoretic Trap with Emphasis on Its Dynamics Properties (사중극자 유전영동 트랩에서의 입자의 동특성에 관한 연구)

  • Chandrasekaran, Nichith;Yi, Eunhui;Park, Jae Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.10
    • /
    • pp.845-851
    • /
    • 2014
  • Dielectrophoresis (DEP) is defined as the motion of suspended particles in solvent resulting from polarization forces induced by an inhomogeneous electric field. DEP has been utilized for various biological applications such as trapping, sorting, separation of cells, viruses, nanoparticles. However, the analysis of DEP trapping has mostly employed the period-averaged ponderomotive forces while the dynamic features of DEP trapping have not been attracted because the target object is relatively large. Such approach is not appropriate for the nanoscale analysis in which the size of object is considerably small. In this study, we thoroughly investigate the dynamic response of trapping to various system parameters and its influence on the trapping stability. The effects of particle conductivity on its motion are also focused.

Estimation of Dielectric Constant of Small Particles Using Negative Dielectrophoresis (Negative Dielectrophoresis를 이용한 미세 입자의 유전율 측정)

  • Lee, Sang-Wook;Kim, Yong-Wook;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.422-424
    • /
    • 1996
  • The dielectric constants of small particles are estimated using negative dielectrophoresis(DEP). A pair of cylindrical electrodes is proposed to produce a non-uniform electric field that levitates a dielectric particle. Measuring the height of the levitated particle, we can calculate the effective polarizability, and estimate the dielectric constant of the particle using a nonlinear regression method. By determining dielectric constant of polystyrene and polychloromethylstyrene particle, the proposed electrode structure and method show the possibility to measure the dielectric constants of dielectric particles.

  • PDF

Analysis of Particles Motion in Liquid Flow in Non-uniform Electric Field (불평등 전계 하 액체유동 내 입자 운동 해석)

  • Chung, Han-Baek;Seo, Kyung-Sik;Choi, Chan-Young;Park, Il-Han
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.3
    • /
    • pp.139-143
    • /
    • 2017
  • In this paper, we propose a separation method of the dielectric particles in the liquid flow. Since particles are dielectric in most cases, they experience dielectrophoretic(DEP) force under non-uniform electric field. The field characteristics in the electromagnetic and fluid dynamic systems are solved by using the finite element method. The motional equation of the particles is calculated by the Runge-Kutta method. The field analysis shows the feasibility of the proposed method. The particle separation model with large DEP force exerting on particles is designed by analyzing field characteristics.

High throughput sorting(HTS) system using a cantilever-type electrode array (캔틸레버(Cantilever) 형태의 전극 어레이(array)를 이용한고속 분리 시스템)

  • Lee, Jung-Hun;Kim, Young-Ho;Kim, Young-Geun;Kim, Byung-Kyu
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.112-117
    • /
    • 2010
  • A high-throughput sorting (HTS) system has been designed to separate target particles using a negative dielectrophoretic (n-DEP) force. The system consists of a meso-sized channel and a cantilever-type electrode(CE) array designed to separate a large number of target particles by discerning subtle difference of weight and dielectric material property of the particles. Using the polystyrene beads with various sizes of 10, 25 and $50{\mu}m$, the developed system exhibits high-throughput sorting of about 200 beads/sec and more than 80 % of separation efficiency.

Using Focus Ion Beam Carbon Nanotube Tip Manipulation (Focus Ion Beam을 이용한 탄소나노튜브 팁의 조작)

  • Yoon Y.H.;Han C.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.461-462
    • /
    • 2006
  • This paper reports on the development of a scanning probe microscopy(SPM) tip with caborn nanotubes. We used an electric field which causes dielectrophoresis(DEP), to align and deposit CNTs on a metal-coated SPM tip. Using the CNT attached SPM tip, we have obtained an enhanced resolution and wear property compared to that from the bare silicon tip through the scanning of the surface of the bio materials. The carbon nanotube tip align toward the source of the ion beam allowing their orientation to be changed at precise angles. By this technique, metal coated carbon nanotube tips that are several micrometer in length are prepared for scanning probe microscopy.

  • PDF

Particle Loss Reduction Technique Using Dielectrophoresis in Microfluidic Channel (유전영동을 이용한 미세유체채널 내부의 입자 손실 저감 기술)

  • Kang, Dong-Hyun;Kim, Min-Gu;Kim, Yong-Jun
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.357-362
    • /
    • 2011
  • This paper demonstrates a novel electrodynamic technique to remove particles from the wall of microchannels. Dielectrohporesis(DEP) is generated by applying alternating electric potentials to the interdigitated electrodes integrated at the bottom of the micro-channel. The proposed technique is applied to a general microfluidic channel as a feasibility test. To examine the wall loss reduction efficiency, 10 ${\mu}m$ diameter Polystyrene latexes(PSL) were supplied to the inlet of the device. Then, the concentration of collected particles through devices was measured. In the experiment for 10 ${\mu}m$ diameter PSL particles, the concentration of the injected particles was $174.25{\times}10^4$ particles/ml. However, the concentration of collected particles at the outlet was $52.25{\times}10^4$ particles/ml. Only 30 % of particles had arrived at the outlet and 70 % of particles had adhered to the wall of the microfluidic channel. By applying alternating electric potentials from 0 to 20 $V_{pp}$ at 3 MHz, the concentration of injected particles was 135.00${\times}10^4$ particles/ml, the concentration of collected particles was increased as $105.25{\times}10^4$ particles/ml at 20 $V_{pp}$ at the outlet. When the electric potential was 20 $V_{pp}$, the particle loss was decreased by 39 % (initial loss: 70 %, loss at 20 Vpp: 31 %) with 10 ${\mu}m$ particle. The particle loss was decreased along to the incensement of electric potentials and the enlargement of the diameter of particles. According to these measured results, it was confirmed that the proposal of using DEP technique could be a good candidate for particle loss reduction in micro-particle processing chip application. Moreover, it is expected that the proposed technique could enhance performance of microfluidic and biochip devices.

Shape Design Optimization of Electrode for Maximal Dielectrophoresis Forces (최대 유전영동력을 위한 전극의 형상 최적설계)

  • Jeong, Hong-Yeon;Cho, Seonho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.4
    • /
    • pp.223-231
    • /
    • 2019
  • A continuum-based design sensitivity analysis(DSA) method is developed for electrostatic problems. To consider high order objective functions, we use 9-node finite element basis functions for analysis and DSA methods. As the design variables are parameterized with B-spline functions, smooth boundary variations are naturally obtained. To solve mesh entanglement problems during the optimization process, a mesh regularization scheme is employed. By minimizing the Dirichlet energy functional, mesh uniformity can be automatically achieved. In numerical examples for maximizing dielectrophoresis forces, the numerical results are compared with well-known electrode geometries and the obtained characteristics are discussed.

Investigation of the Binding Force between Protein A and Immunoglobulin G Using Dielectrophoretic(DEP) Tweezers Inside a Microfluidic Chip (미세유체 칩 내에서 유전영동 집게(Dielectrophoretic Tweezers) 를 이용한 단백질A와 면역 글로불린 G의 결합에 관한 연구)

  • Kwak, Tae Joon;Lee, Jae Woo;Yoon, Dae Sung;Lee, Sang Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.123-128
    • /
    • 2013
  • The 'Dielectrophoretic Tweezers(DEP Tweezers)' can be used as a facile, economical toolkit for quantitative measurement of chemical and biological binding forces related to many biological interactions within a microfluidic device. Our experimental setup can probe the interaction between a single receptor molecule and its specific ligand. Immunoglobulin G(IgG) functionalized on polystyrene microspheres has been used to detect individual surface linked Staphylococcus protein A(SpA) molecules and to characterize the strength of the noncovalent IgG-SpA bond. It was measured and compared with the existing measurements. Measured single binding force of between Goat, Rabbit IgG and SpA were $17{\pm}7pN$, $74{\pm}16pN$. This work can be used to investigate several different ligand-receptor interactions and antigen-antibody interactions.