• Title/Summary/Keyword: Dielectric test

Search Result 415, Processing Time 0.021 seconds

A Study on Insulation Design of HTS Transformer (초전도 변압기의 절연 설계에 관한 연구)

  • 정종만;백승명;김영석;곽동순;김상현
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.232-235
    • /
    • 2003
  • To realize the development of HTS power apparatus, various breakdown test of L$N_2$ should be carried out and the mechanism should be understood more. Moreover the dielectric design technology that the basic dielectric experimental data applied to the HTS power system should be developed. In this paper, the electric fields for the insulation design were calculated for example with the analysis of Weibull distribution. And V-t characteristics of L$N_2$ were discussed. Around the breakdown voltage the n values were less than 1.

  • PDF

Electrical Properties and Interface Effects of 154kV XLPE sheet (154kV급 XLPE의 유전 특성과 계면효과)

  • Lee, Kwan-Woo;Lee, Jong-Bok;Yi, Dong-Young;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.431-433
    • /
    • 2000
  • In this paper, we evaluated the dielectric properties and thermal analysis on sliced XLPE sheet from 154kV power cable and compared with 22kV XLPE sheet. As the result, dielectric constant was not applied voltage dependance but trended to increase with temperature. Test result presented that tan$\delta$ of XLPE with Interface was trend to increased.

  • PDF

Analysis of Test Results for Small Dipstick-Gage-Type Engine-Oil-Deterioration-Detection Sensor (딥스틱게이지형 소형 엔진오일열화감지센서의 시험결과 분석)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.30 no.3
    • /
    • pp.156-167
    • /
    • 2014
  • This paper presents the test results of small dipstick-gage-type engine-oil-deterioration-detection sensor. The measured sensor signal characteristics for the capacitance and temperature are analyzed. The engine oil deterioration condition correlates with the electrical property of the dielectric constant that comprised with physical properties such as TAN (Total Acid Number), TBN (Total Base Number) and viscosity. Several problems encontered during the test of the sensor system are improved. The results of vehicle tests show that the capacitance signal is stable after the engine stops. Therefore, the sensor should start measuring the parameters for monitoring the engine oil condition after the engine stops. The engine is considered to be in a stopped state if the difference between the maximum and minimum values of the oil capacitance measured every 1 min is below 0.02 pF. The key test results in this paper will help in the development of an engine oil change warning algorithm.

The Design of a Power Supply for Planer Type of the Dielectric Barrier Discharge Ozone Reactor with Impedance Matching (유전체 장벽 방전을 이용한 오존 발생기의 전원장치 최적 설계 및 비교)

  • Kim, Bong-Seong;Shin, Young-Chul;Ko, Kwang-Cheol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.57-63
    • /
    • 2011
  • Dielectric Barrier Discharge (DBD) reactor with sinsodual AC type of power supply is very widely adopted for its compact size and effective discharging mechanism to generate high density of ozone radicals. However, at the aspect of design on power supply, its optimal switching conditions and topology is achieved by empirical test. Therefore, throughout this paper, it is proposed a design method of DBD power supply to guarantee a maximum ozone yield rate in accordance with DBD reactor modification and impedance variation when rapid gas discharging in the DBD reactor is proceeded.

A Study on the Styrofoaming Method by UHF Heating (초고주파 가열을 이용한 스티로폼 제조기술 연구)

  • Han Doo Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.1
    • /
    • pp.94-103
    • /
    • 2005
  • The low foamed high strengthen styrofoam samples made by dielectric heating are discussed. We used the oscillator which have the frequency of 13.6 MHz and the power of 7 kW. 3 times expanded beads by steaming method were used in our foam-molding test. Internal fusion properties and density of internal structure were improved by dielectric foaming process. At the temperature of $105-110^{\circ}C$, the internal fusion property was maximally improved.

  • PDF

Decomposition of Acetonitrile Using a Planar Type Dielectric Barrier Discharge Reactor Packed with Adsorption and Catalyst Materials (평판형 유전체 장벽 방전 반응기에서 충진물질에 따른 아세토나이트릴의 분해 특성)

  • 김관태;송영훈;김석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.2
    • /
    • pp.157-165
    • /
    • 2003
  • A combined process of non-thermal plasma and catalytic technique has been investigated to treat $CH_3$CN gas in the atmosphere. A planar type dielectric barrier discharge (DBD) reactor has been used to generate the non-thermal plasma that produces various chemically active species, such as O, N, OH, $O_3$, ion, electrons, etc. Several different types of the beads. which are Molecular Sieve (MS) 5A, MS 13X, Pt/alumina beads, are packed into the DBD reactor, and have been tested to characterize the effects of adsorption and catalytic process on treating the $CH_3$CN gas in the DBD reactor. The test results showed that the operating power consumption and the amounts of the by-products of the non-thermal plasma process can be reduced by the assistance of the adsorption and catalytic process.

Design and Fabrication of a Phase Shifter RFIC using a Tunable Multi-layer Dielectric

  • Lee, Young Chul
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.2
    • /
    • pp.45-49
    • /
    • 2014
  • In this work, a phase shifter radio-frequency integrated chip (RFIC) using a simple all-pass network is presented. As a tuning element of the phase shifter RFIC, tunable capacitors with a multi-layer dielectric of a para-/ferro-/para-electrics using a high tunable BST ferroelectric and a low-loss BZN paraelectric thin film were utilized. In order to evaluate and analyze the fabricated phase shifter RFIC, the same elements such as an inductor and capacitor integrated into it are also fabricated and tested. The designed phase shifter RFIC was fabricated on a quartz substrate in the size of $1.16{\times}1.21mm^2$. As the test results, the maximum phase difference of $350^{\circ}$ is obtained at 15 V and its tuning frequency bandwidth is 90 MHz from 2.72 to 2.81GHz.

The Dielectric Characteristics of Turn-to-Turn Insulation for DC Reactor Type HTSFCL (DC reactor type 고온호전도 한류기의 턴간 절연 특성)

  • 백승명;정종만;이창화;류엔반둥;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1299-1304
    • /
    • 2003
  • Fault current limiters (FCL) are extensively needed to suppress fault currents, especially for trunk power systems heavily connected to high voltage/large current transmission lines. Due to its ideal electrical behavior, high-temperature superconductor fault current limiter (HTSFCL) becomes one of the most important developing trends of limiters in power system. This paper describes the result of an investigation of the dielectric characteristics of turn-to-turn insulation for pancake and solenoid type reactor coil in liquid nitrogen. The influence of thickness in a variety length, on AC, DC and impulse surface flashover has been investigated. Also, the relationships between the number of turn and breakdown characteristics were clarified. The information gathered in this test series should be helpful in the design of liquid nitrogen filled DC reactor type HTSFCL.

Evaluation Method II of the Small Current Breaking Performance of SF$_6$-Blown High-Voltage Gas Circuit Breakers (초고압 $SF_6$가스차단기의 소전류 차단성능 해석기술 II)

  • 송기동;이병윤;박경엽;박정후
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.384-391
    • /
    • 2001
  • The insulation strength between contacts after current interruption to the transient recovery voltage i.e., the dielectric recovery strength should be estimated for the evaluation of the small capacitive current interruption capability. Many authors have used theoretical and semi-experimental approaches to evaluate the transient breakdown voltage after the current interruption. Moreover, an empirical equation, which is obtained from a series of tests, has been used to estimated the dielectric recovery strength. Un this paper, the theoretical method which is generated from the streamer theory has been applied to real circuit breakers in order to evaluated the interruption capability. The results of analysis have been compared with the test results and the reliability has been investigated.

  • PDF

Material Properties Characterization Based on Measurements of Reflection Coefficient and Bandwidth

  • Nguyen, Phuong Minh;Chung, Jae-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.382-386
    • /
    • 2014
  • The knowledge of substrate material properties is important in antenna design. We present a technique to accurately characterize the dielectric constant and loss tangent of an antenna substrate based on the measurements of antenna's reflection coefficient and bandwidth. In this technique, an error function is formulated by combinations of the reflection coefficient and bandwidth of measured and simulated data, and then an optimization technique is used to efficiently search for the substrate properties that minimize the error function. The results show that the method is effective in retrieving the dielectric constant and loss tangent of the antenna substrate without the need of additional test fixtures as in conventional substrate characterization methods.