• 제목/요약/키워드: Dielectric breakdown characteristics

검색결과 328건 처리시간 0.037초

다양한 첨가제에 따른 가교폴리에틸렌의 절연특성 분석 (A study on insulation Characteristics of XLPE by various additives)

  • 송상민;김규식;손원근;류부형;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.193-196
    • /
    • 2001
  • XLPE is occasionally happened to deteriorate cable insulation characteristics. It is happened to do a breakdown state by the degradation of electrical characteristic and electrical breakdown strength. I prepared TR-XLPE (Tree-Retardant XLPE) as adding various additives to prevent its states. Various additives are treeing retardants, anti-oxidants. Treeing retardants three kinds of aromatic compounds as adding each additive. Anti-oxidants use quinone compound and cresol compound as adding each additive. In order to observe each electrical characteristics, I measured breakdown strength, relative dielectric constant$({\varepsilon}_r)$, dielectric loss tangent$(tan{\delta})$. TR-XLPE specimens as adding treeing retardants and anti-oxidants enhance breakdown strength, ${\varepsilon}_r$, $tan{\delta}$ than pure XLPE.

  • PDF

불평등전계에서 $SF_6/CF_4$ 혼합 가스의 SLI, AC 절연내력 특성 (SLI, AC Breakdown Voltage Characteristics of $SF_6/CF_4$ Mixtures Gas in Nonuniform Field)

  • 황청호;성허경;허창수
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.245-251
    • /
    • 2008
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field was performed. The experiments were carried out under AC voltage and standard lightning impulse(SLI) voltage. Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltages and standard lighting impulse voltage was applied in a needle-plane. The needle-plane electrode whose gap distance was 3 mm were used in a test chamber. $SF_6/CF_4$ mixtures contained from 0 to 100% $SF_6$ and the experimental gas pressure ranged from 0.1 to 0.5 MPa. The breakdown characteristics of $SF_6/CF_4$ mixtures in non-uniform field may be influenced by defects like needle-shaped protrusions. In case of slowly rising SLI voltage and AC voltage it is enhanced by corona-stabilization. This phenomena caused by the ion drift during streamer development and the resulting space-charge is investigated. In non-uniform field under negative SLI voltage the breakdown voltage was increase linearly but under positive SLI voltage the breakdown voltage increase non-linearly. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at AC voltage. $SF_6/CF_4$ mixture has good dielectric strength and arc-extinguishing properties than pure SF6. This paper presents experimental results on breakdown characteristics for various mixtures of $SF_6/CF_4$ at practical pressures. We could make an environment friendly gas insulation material with maintaining dielectric strength by combing $SF_6\;and\;CF_4$ which generates a lower lever of the global warming effect.

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

강유전체에서의 전계분포 및 절연파괴 (Dielectric Breakdown and Electric Stress Distribution in Ferroelectrics)

  • 신병철;김호기
    • 한국세라믹학회지
    • /
    • 제24권4호
    • /
    • pp.392-396
    • /
    • 1987
  • Pure barium titanate was sintered at $1340^{\circ}C$ for 2, 4, 8, 16 hr to control their grain size. The measurements of breakdown strength and partial discharge characteristics were performed under rising AC voltage(60Hz). With increase of sintering time, the average grain size was increased and breakdown strength was slightly decreased. Partial discharge in pores was observed under high voltage, and a model of dielectric break down in barium titanate ceramics is proposed.

  • PDF

362 kV GIB 내에서 건조공기의 절연파괴 특성 (Breakdown Characteristics of Dry Air under 362 kV GIB)

  • 한기선;주형준;윤진열;유홍근
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.804-808
    • /
    • 2010
  • In this paper, we studied the dielectric breakdown voltage characteristics by the AC withstand voltage test on using green insulation dry air instead of $SF_6$ insulation gas used in the GIB (gas insulated bus) of 362 kV GIS (gas insulated switchgear). The AC withstand voltage test applied to the standard KEPCO's 362 kV GIB with dry air insulation, and the equivalence of dielectric breakdown voltage for dry air and $SF_6$ gas were examined, and the empirical formulas of dielectric breakdown voltage for dry air were calculated, and the criterion of AC withstand voltage test for dry air insulation was derived. Using the criterion, dry air can be used instead of $SF_6$ gas for 362 kV GIB in the factory acceptance test was confirmed.

질화와 재산화 조건에 따른 모스 소자의 전기적 특성변화 (Electrical properties variations of nitrided, reoxided MOS devices by nitridation condition)

  • 이정석;이용재
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.343-346
    • /
    • 1998
  • Ultra-thin gate oxide in MOS devices are subjected to high-field stress during device operation, which degrades the oxide and exentually causes dielectric breakdown. In this paper, we investigate the electrical properties of ultra-thin nitrided oxide (NO) and reoxidized nitrided oxide(ONO) films that are considered to be promising candidates for replacing conventional silicon dioxide film in ULSI level integration. We study vriations of I-V characteristics due to F-N tunneling, and time-dependent dielectric breakdown (TDDB) of thin layer NO and ONO depending on nitridation and reoxidation condition, and compare with thermal $SiO_{2}$. From the measurement results, we find that these NO and ONO thin films are strongly depending on its condition and that optimized reoxided nitrided oxides (ONO) films show superior dielectric characteristics, and breakdown-to-change ( $Q_{bd}$ ) performance over the NO films, while maintaining a similar electric field dependence compared to NO layer.

  • PDF

Methacrylate/Polyurethane이 함유된 Epoxy 복합재료의 직류 절연 파괴 특성에 관한 연구 (A Study on the DC Dielectric Breakdown Properties of Epoxy Composites Containing Methacrylate/Polyurethane)

  • 김명호;김경환;이덕진;가출현;신성궝;김재환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1357-1359
    • /
    • 1994
  • In this study, in order to improve the problem that dielectric breakdown strength decrease remarkably at high temperature, simultaneous interpenetrating polymer networks method was Introduced so that epoxy insulating material could have stable temperature characteristics and stable dielectric breakdown characteristics at whole temperature range. So network structure of epoxy/$SiO_2$ composite material was changed by adding MA and MA/PU into epoxy resin. DC voltage is applied into the specimen fabricated by this method, and then the result was compared and investigated.

  • PDF

$Al_2O_3$가 충전된 DGEBA/MDA/SN 계의 절연열화 특성 (Dielectric Breakdown Characteristics of $Al_2O_3$ Filled DGEBA/MDA/SN System)

  • 조영신;심미자;김상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.209-211
    • /
    • 1996
  • The dielectric breakdown characteristics of DGEBA/MDA/SN system filled with $Al_2O_3$ under AC high electric field were investigated. As the filler content increased, the dielectric breakdown strength increased, but decreased at higher filler content than 5 phr. The probability of defects such as air bubbles, peel between filler and epoxy resin insulator, etc. increase proportionally to filler contents. Fillers blockade the treeing growth and relax the electric field at the tip of electrical tree and the treeing propagation rate decreases so that the strength showed higher strength at lower filler content than 5 phr.

  • PDF

혼합 에폭시 수지의 전기 절연특성 (Electrical Insulating Characteristics of Mixing Epoxy Resin)

  • 홍경진;정우성;이은학;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1990년도 추계학술대회 논문집
    • /
    • pp.95-97
    • /
    • 1990
  • This study investigated electrical characteristic of solids and liquid epoxy resins by measuring dielectric breakdown and dielectric loss when epoxy resins were exposed to a mixing cure. It was found that mixing epoxy resins were superior to dielectric breakdown and hardness and has shorter curing time compare with those of pure liquid epoxy resins.

Analysis of Dielectric Breakdown of Hot SF6 Gas in a Gas Circuit Breaker

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Song, Ki-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.264-269
    • /
    • 2010
  • This paper presents the analysis of the dielectric characteristics of a hot $SF_6$ gas in a gas circuit breaker. Hot gas flow is analyzed using the FVFLIC method considering the moving boundary, material properties of real $SF_6$ gas, and arc plasma. In the arc model, the re-absorption of the emitted radiation is approximated with the boundary source layer where the re-absorbed radiation energy is input as an energy source term in the energy conservation equation. The breakdown criterion of a hot gas is predicted using the critical electric field as a function of temperature and pressure. To validate the simulation method, breakdown voltage for a 145kV 40kA circuit breaker was measured for various conditions. Consistent results between the simulation and experiment were confirmed.