• Title/Summary/Keyword: Dielectric breakdown characteristics

Search Result 328, Processing Time 0.024 seconds

Humidity Absorbing Deterioration Characteristics of Modified Epoxy Resin System with SN (SN으로 개질된 에폭시 수지 계의 흡습열화 특성)

  • 조영신;심미자;박수길;김상욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.421-424
    • /
    • 1996
  • Effects of humidity absorbing deterioration on AC dielectric breakdown characteristics of modified epoxy resin system with SN(succinonitrile) were investigated. As the forced humidity absorbing deterioration proceeded under high temperature and humidify, glass transition temperature increased. The dielectric breakdown strength increased and then decreased at deterioration cycles higher than 2. Not only, the increment of thermal stability but also, the physical detects such as Internal cracks and voids occurred during the humidity absorbing deterioration cycle were the main causes of the change in dielectric properties.

  • PDF

The Characteristics of Dielectric Breakdown for Epoxy Resin irradiated Electron Beam (전자선 조사된 에폭시 수지의 절연파괴 특성)

  • Hong, Nung-Pyo;Cho, Dong-Chan;Park, Heung-Kyu;So, Byung-Mun;Kim, Wang-Kon;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.430-432
    • /
    • 1995
  • In this paper, the electron beam with 1[Mrad], 2[Mrad], 4[Mrad], 8[Mrad] and 24[Mrad] is irradiated for specimen experiments on physical properties which is investigated by FTIR, and dielectric breakdown among the electrical characteristics of specimen are carried out. For the dielectric breakdown experiment, external 60 [Hz] AC voltage is applied to specimen with the rising voltage of 3[kV/cm] until dielectric breakdown occured. We made a breakdown experiment under the temperature condition of 50[$^{\circ}C$], 100[$^{\circ}C$], 150[$^{\circ}C$] in the silicone oils of dynamic viscosity of 100[cSt].

  • PDF

Investigation on DC Breakdown Strength Characteristics of Power Cable Insulation (전력 케이블 절연재에 대한 DC절연파괴강도특성 고찰)

  • Lee, Han-Joo;Jung, Eui-Hwan;Joe, Sung-Hoon;Yoon, Jae-Hoon;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.86-86
    • /
    • 2010
  • Recently, CV, CNCV, CNCV-W cable are used to transmit and distribute electric power. And a lot of researchers put more effort to realize high performance. The dielectric breakdown strength characteristic is a standard to design insulators. Examination of that is a main factor to determine long term insulation performance, which is used to diagnose Insulation deterioration. In this paper, we prepared XLPE, XLPE/nano-filler, LDPE/nano-filler for comparing each of the dielectric breakdown strength characteristics.

  • PDF

An Analysis of Insulating Reliability in Polyethylene for High Frequency Molding Materials (고주파 성형 재료용 폴리에칠렌의 절연 신뢰도 분석)

  • Park, Geon-Ho;Kim, Ki-Joon;Wang, Jong-Bae;Shin, Chul-Ki;Kim, Jin-Sa;Lee, Joon-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.64-67
    • /
    • 2000
  • In this study, the DC dielectric breakdown of polyethylene used for clothing material of cable was experimented and then its data were simulated by Weibull distribution probability. The dielectric breakdown characteristics in polyethylene were examined and various effects of the DC dielectric breakdown on polyethylene were also discussed.

  • PDF

Electrical Characteristic Assessment of Nomex Paper for Distribution Transformers

  • Song, Il-Keun;Jung, Jong-Wook;Lee, Byung-Sung;Kwak, Hee-Ro
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.3
    • /
    • pp.86-90
    • /
    • 2003
  • This paper describes the electrical characteristics of Nomex paper employed as an insulating material for distribution transformers. The relative permittivities (dielectric constants) and tan$\delta$ (dielectric dissipation factors) were measured as dielectric characteristics and the partial discharge inception voltages (PDIVs) and breakdown voltages were also measured as electrical strength characteristics of Nomex paper. As a result, the permittivity and tan $\delta$ of Nomex paper demonstrated both temperature and frequency dependency. Of particular note, the permittivity of 0.18 mm Nomex paper was 2.4 according to the ASTM condition, The PDIVs and breakdown voltages were almost linearly increased with the thickness of Nomex paper. Furthermore, its electrical strength was superior to conventional Kraft paper.

Electrical Breakdown Properties of Insulating Oils for oil-immersed transformer (유입변압기용 절연유의 절연파괴특성)

  • 이인성;신현택;이종필;이수원;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.605-608
    • /
    • 2001
  • With the intention of investigating the breakdown properties of oil-immersed transformer oils in temperature range of 20∼100[$^{\circ}C$], we are made researches AC breakdown in the gap of 500∼2,500[$\mu\textrm{m}$]. The classification for the physical properties of oil for oil-immersed transformer by FTH and $^1$H-NMR experiments was confirmed to type of mineral oils. As the dependance of breakdown properties due to electrode gap length variation, breakdown voltage was found increasing according to the increase of gap, while dielectric strength was decreasing. As a result the characteristics for AC breakdown, It goes to prove that the breakdown voltage was increased to 90[$^{\circ}C$] but decreased over 90[$^{\circ}C$] in the temperature range. Also, breakdown voltage was found increasing in the increase of gap and the rising of temperature according to Weibull distribution.

  • PDF

Dielectric Breakdown Characteristics Depending on The Nano Filler of Epoxy Nano-composites (나노 충진제에 따른 에폭시 나노 컴퍼지트의 절연파괴강도 특성)

  • Park, Tae-Hak;Back, Sung-Hak;Lee, Dong-Gun;Park, Hong-Kyu;Jeong, In-Bum;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.92-92
    • /
    • 2010
  • In this paper, the test is performed on MgO, which is used as a filler in epoxy additives, respectively (0, 1.0, 3.0, 5.0, 7.0, 10 [wt%]) for HVDC(high voltage direct current) submarine cable insulating material to improve electrical properties of epoxy resin in high temperature. The breakdown strength due to increasing amount of filler increased to 5.0 [wt%] by the effects of the Coulomb blockade. However, it is confirmed that strength of dielectric breakdown decreased because the filler functioned as impurities and affected the breakdown when filler additive exceeded by 5.0 [wt%] or more. We have found that the highest dielectric breakdown strength of specimen added 5.0 wt% at $25^{\circ}C$, and is more increased approximately 13.7 [%] than virgin specimen.

  • PDF

A Study on the Dielectric Breakdown Strength Characteristics of Epoxy-$SiO_2$ Compound Material for Electric Installation (전기설비용 에폭시-$SiO_2$ 복합재료의 절연파괴 특성에 관한 연구)

  • 김재환;박창옥
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.2
    • /
    • pp.77-83
    • /
    • 1991
  • In this study the investigation were carried out on short-term breakdown characteristics of the compound material dependent on change of filler quantity, ambient temperature(room temperature~[$190[^{\circ}C$]) and kinds of voltage sources for the compound materials of Bisphenol- A epoxy resins filled with $SiO_2$ particles. As the results, obtained the dielectric breakdown strength generally decrease as increasing the quantity of filler and the distance, spacing of each's particles, decrease as increasing the quantity of filler, when the distance is less than [$7.5\mu\textrm{m}$], dielectric breakdown strength is nearly constant. In the case on AC voltage dielectric strength of filled epoxy resins is stronger than nonfilled epoxy resins on temperature region more than $130[^{\circ}C$].

  • PDF

Breakdown and Surface Flashover Characteristics of FRP in $LN_2$ (액체질소 중 FRP의 절연파괴 및 연면방전 특성 연구)

  • 정종만;백승명;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.119-123
    • /
    • 2002
  • In this study, we discussed the characteristics of breakdown and surface flashover of FRP in L$N_2$ for applying it to spacer of a superconducting power equipment. Fiberglass reinforced plastic(FRP) has high breakdown puncture strength and has high mechanical strength. So the research of its dielectric properties have been conducted in liquid nitrogen($LN_2$). We measured breakdown voltage of FRP and distinguished four types of surface flashover along solid insulator with arrangement of electrodes and measured the surface flashover voltages of each types of electrode arrangement. The type of a electrode set at the back of the insulator showed the worst dielectric property. The property of surface flashover depending on pressure was tested.

Study On Mechanism of Dielectric Breakdown in Polyimide Film

  • Tong, Laisheng;Zhang, Xueqing;Wu, Guangning
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.3-8
    • /
    • 2004
  • The Pulse Width Modulation (PWM) Inverter plays an important role in express locomotive. Especially after traction motors are fed by fast switching inverters, the interturn insulation is destroyed more heavily. However, a new type of polyimide corona resistant film is developed and used in insulation of traction motors. In order to investigate the service life of this kind of traction motor, the mechanism and characteristics of dielectric breakdown of polyimide corona resistant are studied in the paper. Experiments have been carried out on specimen according to the condition of traction motor. The breakdown point of tested sample film is analyzed through energy spectrum analysis and electron microscopic photograph. At last, it is presented that the characteristics and mechanism of breakdown of polyimide corona resistance film.

  • PDF