• 제목/요약/키워드: Dielectric Strength

검색결과 577건 처리시간 0.027초

대용량 변압기유의 전기적특성에 관한 연구 (A Study on the Electrical Properties of Transformer Oils for Large Power)

  • 이용우;김왕곤;홍진웅
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.81-88
    • /
    • 1996
  • In order to investigate the electrical properties of transformer oils for large power, the characteristics of AC and Impulse breakdown in gap length of 1.0~2.5mm and that of volume resistivity were researched in temperature range of 20~$100^{\circ}C$. An geometrical capacitance of electrode with coaxial cylindrical shape for measuring the volume resistivity was 16pF, and highmegohm meter with model no. VMG-1000 was used, and also the applied voltage were DC 100, 250 and 500V. In the dependance of breakdown characteristics due to electrode gap length, it was confirmed that breakdown voltage was nearly uniform by volume effect according to the increase of gap. In the characteristics for AC breakdown, the dielectric strength was increased to $90^{\circ}C$ but decreased over $90^{\circ}C$, and also in case of impulse breakdown, it was increased to 7$0^{\circ}C$ and at dated $70^{\circ}C$ over in temperature range. The calculated mobility of oils in the characteristics for impulse breakdown were about $10^{-5}$~$10^{-4}cm^2/V{\cdot}S$, and the value of volume resistivity was almost invariable in low temperature range, regardless of voltage by the stable thermal properties, and it indicated a peak at $50^{\circ}C$ and had a sudden change to decrease over that temperature, and also the value of volume resistivity in 250V/mm at $80^{\circ}C$ is suitable for the International electrical standards, it was confirmed.

  • PDF

고 전력 DMOSFET 응용을 위한 트렌치 게이트 형성에 관한 연구 (A Study on the Formation of Trench Gate for High Power DMOSFET Applications)

  • 박훈수;구진근;이영기
    • 한국전기전자재료학회논문지
    • /
    • 제17권7호
    • /
    • pp.713-717
    • /
    • 2004
  • In this study, the etched trench properties including cross-sectional profile, surface roughness, and crystalline defects were investigated depending on the various silicon etching and additive gases, For the case of HBr$He-O_2SiF_4$ trench etching gas mixtures, the excellent trench profile and minimum defects in the silicon trench were achieved. Due to the residual oxide film grown by the additive oxygen gas, which acts as a protective layer during trench etching, the undercut and defects generation in the trench were suppressed. To improve the electrical characteristics of trench gate, the hydrogen annealing process after trench etching was also adopted. Through the hydrogen annealing, the trench corners might be rounded by the silicon atomic migration at the trench corners having high potential. The rounded trench corner can afford to reduce the gate electric field and grow a uniform gate oxide. As a result, dielectric strength and TDDB characteristics of the hydrogen annealed trench gate oxide were remarkably increased compared to the non-hydrogen annealed one.

실리콘 고무의 플라즈마 표면처리된 반도전-절연계면 처리에 따른 접착특성과 절연성능 (Adhesion and Electrical Performance by Plasma Treatment on Semiconductive-Insulation Interface Layer of Silicone Rubber)

  • 황선묵;이기택;홍주일;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper, the effect of adhesion properties of semiconductive-insulating interface layer of silicone rubber on electrical properties was investigated. The modifications produced on the silicone surface by oxygen plasma were accessed using ATR-FTIR, contact angle and AFM. Adhesion was obtained from T-peel tests of semiconductive layer having different treatment durations. In addition, ac breakdown test was carried out for elucidating the change of electrical property with duration of plasma treatment. From the results, the treatment in the oxygen plasma produced a noticeable increase in surface energy, which can be mainly ascribed to the the creation of O-H and C=O. It is observed that adhesion performance was determined by not surface energy but roughness level of silicone surface. It is found that ac dielectric strength was increased with improving the adhesion between the semiconductive and insulating interface.

  • PDF

변압기에 용존된 Furan계 물질 분석 (Analysis of Furanic Compounds Dissolved in Transformer Oil)

  • 김재훈;이병성;이세현;구경완;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.1909-1911
    • /
    • 2005
  • The electrical and chemical characteristics in transformer insulations are changed due to thermal stress. In the chemical property, as the Kraft paper ages, the cellulose polymer chains breakdown into shorter lengths with a corresponding decrease in both tensile strength and degree of polymerization(DP). Furthermore, cellulous chains breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furan products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. In this paper the accelerated aging process of oil--paper samples have been investigated at a temperature up to $140^{\circ}C$ for 500 hours. The oil-paper insulation samples have been measured at intervals of 100 hours. For analysis we used high performance liquid chromatography(HPLC) in accordance with IEC 61198 method.

  • PDF

기능성 경사 재료의 적용을 통한 진공 인터럽터의 삼중점 전계 완화 (Reduction of the Electric Field Concentration at the Triple Junction of the Vacuum Interrupter by Using the Application of Functionally Graded Material)

  • 최승길;구치욱;주흥진
    • 한국전기전자재료학회논문지
    • /
    • 제28권10호
    • /
    • pp.630-635
    • /
    • 2015
  • A vacuum Interrupter (VI), a core part that composes the breaking part of medium-voltage vacuum circuit breaker (VCB), has the excellent insulation performance and arc-extinguishing capability. $SF_6$ gas had been used for the external insulation of VIs since the dielectric strength of $SF_6$ gas is superior to that of other insulation gases. However, because of environmental problems related with global warming, a solid-insulated technology was recently researched. The functionally graded material (FGM), as changing spatially the distribution of the relative permittivity inside an insulator, can reduce the electric field stress at the specific region. Especially, the external insulation performance of the VI with the molded FGM insulator is greatly improved as compared with that of the existing VI or the VI with a new external shield. In this paper, the effectiveness of this FGM insulator is verified by the numerical simulation.

불평등 전계에서 표준 뇌 임펄스 전압의 $SF_6/CF_4$ 혼합 가스의 절연 내력 (Dielectric Strength of $SF_6/CF_4$ Mixture Under Standard Lightning Impulse Voltages in Non-Uniform Field)

  • 허창수;성허경;박신우;황청호;김남렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.165-166
    • /
    • 2007
  • In these days $SF_6$ mixtures and alternative gas have been studied because of global warming and liquefying at low temperature and high pressure. At present work the breakdown characteristics of $SF_6/CF_4$ mixture in non-uniform field was performed. The experiments were carried out under positive and negative standard lightning impulse (SLT) voltages. The point-plane electrode was used with 3 mm gap distance in the test chamber. The $SF_6/CF_4$ mixture which contain 20% of $SF_6$ was compared with pure $SF_6$ and $CF_4$ gas. Experimental gas pressure ranged from 0.1 to 0.4 MPa. The breakdown voltage under negative SLI is higher than the breakdown voltage under positive voltage. And the breakdown voltage of $SF_6$ 20%, $CF_4$ 80% mixture is similar to that of pure $SF_6$.

  • PDF

부분방전검출 신뢰도 향상을 위한 UHF 센서개선 및 성능검증 (Performance Verification and Improvement of UHF Sensor for the Increasement of the Partial Discharge Detection Reliability)

  • 김원규;김민수;백영식
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1461-1466
    • /
    • 2014
  • GIS(Gas Insulated Switchgear) is important power apparatus which have strong dielectric strength, supply electric power and is a part of the power system. Most substation type is configured as GIS. Recently, because of continuous increasement of GIS demand resulted from high quality & big capacity of electric power, the necessity of the preventive & diagnosis system is being expanded gradually. GIS partial discharge occurred on the UHF band is detected effectively by the method to IEC 60270 that recommend to be able to detect the apparent minimum discharge, 5 pC. Additionally, the UHF sensor should be installed to detect PD signal if Partial discharge signal, 5 pC occur in every part of GIS. Currently PD diagnosis system applying UHF sensor for GIS with various voltage level like 154 kV, 345 kV, 765 kV have been operated. And it is necessary to measure and analyze insulation breakdown phenomenon of inside GIS exactly. In this paper, we proposed Fat-dipole patch UHF sensor that is developed and more sensitive, excellent wide-range characteristic than the exising UHF sensor. And we performed KERI (Korea Electrotechnology Research Institute) reference test, which showed the excellent result for the all tests.

다중 분산부하 전압강하산정 프로그램 연구 (A Study of the Voltage drops computation program on multi-distributed random loads)

  • 강차녕;권세혁;조성필
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.37-42
    • /
    • 2006
  • 전선에서 전압강하는 열 손실을 의미한다. 이 열은 절연체의 특성을 변화시켜 절연성능을 저하시키게 되고 나아가 누전, 감전, 정전 및 화재 등의 사고를 일으키는 원인이 되기도 한다. 그러므로 전압강하에 대한 최적화 설계는 전기설비의 안전성과 경제성을 보장하는 중요한 요소가 되고 있다. 이에 저압의 전기설비인 가로등, 빌딩, 지하철역사 등 공공의 안전확보가 요구되는 다중 분산부하계통에서의 전압강하가 전기배선에 미치는 영향을 분석하고, 안전성 및 경제성 확보를 위한 전압강하산정 프로그램 및 최적화 방안을 연구 제시하고자 한다.

  • PDF

Effect of Nano/micro Silica on Electrical Property of Unsaturated Polyester Resin Composites

  • Sharma, Ram Avatar;D'Melo, Dawid;Bhattacharya, Subhendu;Chaudhari, Lokesh;Swain, Sarojini
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권1호
    • /
    • pp.31-34
    • /
    • 2012
  • The addition of nano/micro silica into unsaturated polyester resin (UPR) results in the improvement of the electrical properties of Silica-UPR composites. The surface, volume resistivity, dielectric strength, dissipation factor and dry arc resistivity of nano silica-UPR composites were found to improve significantly. The effects of the nano and micro fillers in UPR have been evaluated. They are presented in this paper. To evaluate the electrical properties of the nano & micro composites, all the measurements were done as per the prescribed methods in ASTM. It was observed that the addition of nano silica improves the electrical properties as compared to micro silica. The better dispersion of silica particles in unsaturated polyester resin enhances the electrical properties of silica-UPR composites.

시멘트 모르타르의 수분변화에 따른 평균화된 전자기 특성에 대한 실험적 연구 (An Experimental Study on Characteristics of Averaged Electromagnetic Properties considering Moisture Changes in Cement Mortar)

  • 권성준;;나웅진
    • 콘크리트학회논문집
    • /
    • 제21권2호
    • /
    • pp.199-207
    • /
    • 2009
  • 콘크리트 또는 시멘트 모르타르와 같은 비금속성 재료에서 유전상수와 전도율과 같은 전자기 평가는 특성화 될 수 있으므로 최근 들어 많은 연구가 수행되고 있다. 그러나 이러한 전자기 특성은 수분에 의하여 매우 큰 영향을 받으므로 이에 대한 전자기 거동이 명확하게 이해되어야 한다. 본 논문에서는 5가지 물-시멘트비를 가지는 시멘트모르타르에 대하여, 포화도 및 전자기 특성 측정이 압축강도와 공극률 평가와 함께 수행되었다. 각각의 포화된 시편은 실내상태에 존치되었으며, 포화도의 변화에 따른 전자기 특성이 분석되었다. 포화상태에서는, 공극률이 높은 시편에서 높은 전자기 특성이 평가되었지만, 이러한 관계는 건조가 진행됨에 따라 반대로 평가되었다. 공극수가 없는 공극에서 전자기 특성이 감소되므로, 물-시멘트비가 낮아질수록 안정적이고 선형적인 전자기 특성 증가를 나타내었다. 한편, 물-시멘트비에 따른 전자기 특성 증가율이 포화도와 함께 제시되었으며, 회귀분석을 통하여 그 상관관계가 도출되었다.