• 제목/요약/키워드: Die Materials

검색결과 1,275건 처리시간 0.026초

Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems

  • Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.439-448
    • /
    • 2016
  • PURPOSE. The purposes of this study are to evaluate the internal and marginal adaptation of two widely used CAD/CAM systems and to study the effect of porcelain press veneering process on the prosthesis adaptation. MATERIALS AND METHODS. Molar of a lower jaw typodont resin model was prepared by adjusting a 1.0 mm circumferential chamfer, an occlusal reduction of 2.0 mm, and a $5^{\circ}$ convergence angle and was duplicated as an abrasion-resistant master die. The monolithic crowns and copings were fabricated with two different CAD/CAM system-Ceramil and Zirkonzahn systems. Two kinds of non-destructive analysis methods are used in this study. First, weight technique was used to determine the overall fitting accuracy. And, to evaluate internal and marginal fit of specific part, replica technique procedures were performed. RESULTS. The silicone weight for the cement space of monolithic crowns and copings manufactured with Ceramil system was significantly higher than that from Zirkonzahn system. This gap might cause the differences in the silicone weight because the prostheses were manufactured according to the recommendation of each system. Marginal discrepancies of copings made with Ceramil system were between 106 and $117{\mu}m$ and those from Zirkonzahn system were between 111 and $115{\mu}m$. Marginal discrepancies of copings made with Ceramil system were between 101 and $131{\mu}m$ and those from Zirkonzahn system were between 116 and $131{\mu}m$. CONCLUSION. Marginal discrepancy was relatively lower in Ceramil system and internal gap was smaller in Zirkonzahn system. There were significant differences in the internal gap of monolithic crown and coping among the 2 CAD/CAM systems. Marginal discrepancy produced from the 2 CAD/CAM systems were within a reported clinically acceptable range of marginal discrepancy.

텅스텐 중합금의 부피분율, 입자형상에 따른 단열전단밴드 형성 연구 (The Effects of Volume Ratio and Shape on the Formation of Adiabatic Shear Band in WHA)

  • 이승우;송흥섭;문갑태
    • 소성∙가공
    • /
    • 제11권8호
    • /
    • pp.682-690
    • /
    • 2002
  • The formation of adiabatic shearband in tungsten heavy alloys(WHA) was studied in this investigation. Five prismatic specimens were loaded by high velocity impacts and treated as plane strain problems. To find out the effect of particle's volume ratio, specimens containing 81%, 93% and 97% volume percents of tungsten particles were used. Also the effects of particle's geometry and size on the formation of shearband were studied for 81% volume percent alloys by small size particle model, large size particle model and undulated particle models, and the results were discussed.be used to diagnose the causes of necking and fracture in industrial practice and to investigate whether these defects were caused by material property variation, changes in lubrication, or incorrect press settings. In non-axisymmetric deep drawing, three modes of forming regimes are found: draw, stretch, plane strain. The stretch mode for non-axisymmetric deep drawing could be defined when the major and minor strains are positive. The draw mode could be defined when the major strain is positive and minor strain is negative, and plane strain mode could be defined when the major strain is positive and minor strain is zero. Through experiments the draw mode was shown on the wall and flange are one of a drawn cup, while the plane strain and the stretch mode were on the punch head and the punch corner area respectively, We observed that the punch load of elliptical deep drawing was decreased according to increase of die corner radius and the thickness deformation of minor side was more large than major side.

NCP 적용 COB 플립칩 패키지의 신뢰성에 미치는 실리카 필러의 영향 (Effects of silica fillers on the reliability of COB flip chip package using NCP)

  • 이소정;김준기;이창우;김정한;이지환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.158-158
    • /
    • 2008
  • 모바일 정보통신기기를 중심으로 실장모듈의 초소형화, 고집적화로 인해 접속단자의 피치가 점점 미세화 됨에 따라 플립칩 본딩용 접착제에 함유되는 무기충전제인 실리카 필러의 크기도 미세화되고 있다. 본 연구에서는 NCP (non-conductive paste)의 실리카 필러의 크기가 COB(chip-on-board) 플립칩 패키지의 신뢰성에 미치는 영향을 조사하였다. 실험에 사용된 실리카 필러는 Fused silica 3 종과 Fumed silica 3종이며 response surface 실험계획법에 따라 혼합하여 최적의 혼합비를 정하였다. 테스트베드로 사용된 실리콘 다이는 투께 $700{\mu}m$, 면적 5.2$\times$7.2mm로 $50\times50{\mu}m$ 크기의 Au 도금범프를 $100{\mu}m$ 피치, peripheral 방식으로 형성시켰으며, 기판은 패드를 Sn으로 finish 하였다. 기판을 플라즈마 전처리 후 Panasonic FCB-3 플립칩 본더를 이용하여 플립칩 본딩을 수행하였다. 패키지의 신뢰성 평가를 위해 $-40^{\circ}C{\sim}80^{\circ}C$의 열충격시험과 $85^{\circ}C$/85%R.H.의 고온고습시험을 수행하였으며 Die shear를 통한 접합 강도와 4-point probe를 통한 접속저항을 측정하였다.

  • PDF

The effect of zirconia framework design on the failure of all-ceramic crown under static loading

  • Urapepon, Somchai;Taenguthai, Pakamard
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.146-150
    • /
    • 2015
  • PURPOSE. This in vitro study aimed to compare the failure load and failure characteristics of two different zirconia framework designs of premolar crowns when subjected to static loading. MATERIALS AND METHODS. Two types of zirconia frameworks, conventional 0.5 mm even thickness framework design (EV) and 0.8 mm cutback of full contour crown anatomy design (CB), were made for 10 samples each. The veneer porcelain was added on under polycarbonate shell crown made by vacuum of full contour crown to obtain the same total thickness of the experiment crowns. The crowns were cemented onto the Cobalt-Chromium die. The dies were tilted 45 degrees from the vertical plane to obtain the shear force to the cusp when loading. All crowns were loaded at the lingual incline of the buccal cusp until fracture using a universal testing machine with cross-head speed 0.5 mm/min. The load to fracture values (N) was recorded and statistically analyzed by independent sample t-test. RESULTS. The mean and standard deviations of the failure load were $1,170.1{\pm}90.9$ N for EV design and $1,450.4{\pm}175.7$ N for CB design. A significant difference in the compressive failure load was found (P<.05). For the failure characteristic, the EV design was found only cohesive failures within veneering porcelain, while the CB design found more failures through the zirconia framework (8 from 10 samples). CONCLUSION. There was a significant difference in the failure load between two designs, and the design of the framework influences failure characteristic of zirconia crown.

Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns

  • Kwon, Taek-Ka;Pak, Hyun-Soon;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.92-97
    • /
    • 2013
  • PURPOSE. All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. MATERIALS AND METHODS. Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. RESULTS. The mean fracture strengths were as follows: $54.9{\pm}15.6$ N for the Lava CAD/CAM zirconia crowns and $87.0{\pm}16.0$ N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. CONCLUSION. The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain.

Thoracic Irradiation Recruit M2 Macrophage into the Lung, Leading to Pneumonitis and Pulmonary Fibrosis

  • Park, Hae-Ran;Jo, Sung-Kee;Jung, Uhee
    • Journal of Radiation Protection and Research
    • /
    • 제42권4호
    • /
    • pp.177-188
    • /
    • 2017
  • Background: Radiation-induced pneumonitis and pulmonary fibrosis are common dose-limiting complications in patients receiving radiotherapy for lung, breast, and lymphoid cancers. In this study, we investigated the characteristics of effective immune cells related to pneumonitis and fibrosis after irradiation. Materials and Methods: After anesthesia, the whole thorax of C57BL/6 mice was irradiated at 14 Gy. The lung tissue and bronchoalveolar lavage fluid were collected at defined time points post-irradiation for the determination of histological and immunohistochemical analysis and inflammatory cell population infiltrated into the lung. Results and Discussion: Whole thoracic irradiation increased the deposition of extracellular matrix (ECM), lung weight, and pleural effusions, which started to die from 4 months later. At 4 months after irradiation, the numbers of macrophages and lymphocytes as well as neutrophils were increased dramatically in the lung. Interestingly, the macrophages that were recruited into the lung after irradiation had an enlarged foamy morphology. In addition, the expressions of chemokines (CCL-2, CCL-3, CXCL-10) for the attraction of macrophages and T cells were higher in the lung of irradiated mice. The high expressions of these chemokines were sustained up to 6 months following irradiation. In thoracic irradiated mice, infiltrated macrophages into the lung had the high levels of Mac-3 antigens on their surface and upregulated the hallmarks of alternatively activated macrophages such as arginase-1 and CD206. Furthermore, the levels of IL-4 and IL-13 were higher in a BAL fluid of irradiated mice. Conclusion: All results show that thoracic irradiation induces to infiltrate various inflammation-related immune cells, especially alternatively activated macrophages, through enhancing the expression of chemokines, suggesting that alternatively activated macrophages are most likely important for leading to pulmonary fibrosis.

흡착재의 종류에 따른 경화체의 라돈가스흡착 특성 (Properties of Radon Gas Absorption of Matrix According to Types of Absorbent)

  • 권오한;임현웅;이상수
    • 한국건축시공학회지
    • /
    • 제17권1호
    • /
    • pp.15-21
    • /
    • 2017
  • 라돈은 토양이나 암석, 지하수 안에서 우라늄(U-238)이 핵분열 할 때 발생하는 무색, 무취, 무미의 반응성이 거의 없는 비활성 단원자 분자 기체로 반감기 동안 연쇄적으로 붕괴하는데 이때 방사성 핵종(Bi, Po, Pb)이 만들어 지며 이를 자손핵종이라 한다. 이는 공기 중의 먼지 등에 흡착하여 사람이 호흡할시 폐에 흡착하여 붕괴하는데 여기서 발생하는 알파선에 장기간 피폭하면 폐암을 유발하는 것으로 밝혀졌다. 이에 따라 실내공기질에 관한 기준과 연구가 지속적으로 시행되고 있는 실정이다. 본 연구는 실내 라돈가스를 최소화 하고 저감하기 위한 무시멘트계 흡착재를 연구개발 하기위한 기초실험으로 흡착재의 첨가량에 따라 유동성 및 강도는 저하되는 경향을 보였지만, 이는 흡착재의 밀도 및 공극에 의한 것으로 판단되며, 라돈가스 농도의 경우 첨가량 증가에 따라 감소하는 경향을 보였다. 향후 가장 적합한 흡착재를 활용하여 보다 세밀하고 다양한 실험이 이루어져야 할 것으로 판단되며, 경화체상의 기초실험을 통해 추후 건축 마감재에 관한 실험도 이루어져야 할 것이다.

유전 알고리즘-BP신경망을 이용한 Al3004 판재 점진성형 공정변수에 대한 최적화 연구 (Optimization of Process Parameters of Incremental Sheet Forming of Al3004 Sheet Using Genetic Algorithm-BP Neural Network)

  • 양센;김영석
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.560-567
    • /
    • 2020
  • 점진판재성형은 금형을 제작하지 않고 판재를 가공하는 방법으로서 빠른 시제품 제작과 소량 생산에 적합한 성형법이다. 이러한 점진판재성형의 공정 변수로 공구 직경, 매 스탭당 Z-방향 깊이, 공구 이송 속도, 공구 회전 속도 등은 성형품의 품질에 크게 영향을 미친다. 본 연구에서는 두께가 1.0mm인 Al3004판재를 사용하여 원뿔절두체(VWACF: Varying Wall Angle Conical Frustum) 모델의 점진성형을 실시하였으며, 각각의 변수들의 조합에서 성형성을 판단하였다. BP신경망 (BPNN: Back Propagation Neural Network)를 기반으로 Minitab 소프트웨어를 사용하여 성형 각도를 예측하는 2 차 수학적 모델을 구축하였다. 또한 이 모델을 유전 알고리즘의 목적함수로 사용하였으며 최대 성형 각도로 얻기 위한 최적의 변수 조합을 찾아내었다. 공구 직경은 6mm, 회전 속도는 180rpm, Z-방향 피치는 0.401mm, 이송 속도는 772.4mm/min일 경우 가장 큰 성형 각도인 87.071°를 갖는 컵을 성형할 수 있었다.

사각형 판재성형 시 벽두께 증육을 위한 금형 및 공정 설계 (Process and Die Design of Square Cup Drawing for Wall Thickening)

  • 김진호;홍석무
    • 한국산학기술학회논문지
    • /
    • 제16권9호
    • /
    • pp.5789-5794
    • /
    • 2015
  • 최근 스마트 폰, 모바일 PC 제품의 외관에 필요한 가벼운 금속제품으로 제조를 하기 위하여 알루미늄 압출 공정과 CNC 가공기법을 적용한 생산방식이 널리 사용되고 있다. 하지만, 알루미늄 압출법은 외관 디자인의 제약이 있으며, 특히 CNC 가공 프로세스가 상대적으로 높은 생산 비용 및 낮은 생산성으로 생산단가가 많이 높은 단점이 있다. 본 연구에서, 새로운 처리 방법을 순서 재료비를 대폭 감소시키고, 제조 속도를 향상시키기 위해 판재성형과 부피성형의 두가지 공정을 섞어 새로운 판단조 공정을 개발하였다. 새로운 판단조 공법(hybrid plate forging)이란 우선 일반적인 딥드로잉으로 중간 모양을 만든 후 원하는 벽 부위만 증육을 하는 방법을 의미한다. 이러한 판단조 공법을 활용하여 재료의 낭비와 제조 시간을 최소화하는 것이 가능하게 된다. 본 연구에서는 상용 유한 요소 프로그램 AFDEX-2D를 통해 판단조공정을 설계하였고 최적의 사용 가능한 소재의 두께와 초기 폭을 설계하였다. 최종적으로 실제 노트북 케이스 금형을 제작하여 제안한 방법의 타당성을 검증하였다.

다수 캐비티의 사출성형품에서 충전의 불균형과 성형품 치수 편차의 교찰 (Investigation of the Filling Unbalance and Dimensional Variations in Multi-Cavity Injection Molded Parts)

  • 강민아;류민영
    • 폴리머
    • /
    • 제32권6호
    • /
    • pp.501-508
    • /
    • 2008
  • 렌즈나 휴대폰 부품 같은 소형 플라스틱 부품들은 일반적으로 다수 캐비티 사출금형에서 성형된다. 이러한 다수 캐비티 금형에서의 사출성형은 캐비티간의 충전 불균형이 일어날 수 있다. 이러한 충전 불균형 현상은 제품의 치수 및 중량의 편차뿐 아니라 제품의 물리적 특성에도 영향을 미친다. 충전 불균형은 무엇보다도 기하학적으로 균형 잡히지 않은 delivery system의 설계에서 기인된다. 하지만 delivery system이 기하학적으로 균형 있게 설계가 되었다 하더라도 충전 불균형 현상은 여전히 발생된다. 이러한 현상은 런너 단면에서의 온도분포에 기인하며 사출성형 공정 중 사출속도에 크게 영향을 받는 것으로 본 연구에서 파악되었다. 즉 충전 불균형은 부적절한 사출 성형 공정에 의해 발생되며 성형 공정 조건 중 사출속도는 충전에 영향을 주는 매우 중요한 요소이다. 본 연구에서는 재료와 사출 속도에 따른 충전 불균형 현상을 실험과 CAE을 통하여 관찰하였다. 사출속도 변화에 따른 충전 불균형 때문에 시편의 치수 및 무게가 불균일함을 확인하였다.