• 제목/요약/키워드: Diameter of mass

검색결과 1,236건 처리시간 0.028초

R-22 및 R-134a의 세관 내 유동 특성에 관한 연구 (Study on the Flow Characteristics of R-22, R-l34a in Small Diameter Tubes)

  • 홍진우;정재천;장승환;권옥배;오후규
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.756-765
    • /
    • 2002
  • Experimental work was performed on the flow characteristics of R-22 and R-l34a in small diameter tubes. The experimental apparatus was made up of liquid pump, pre-heater, sight-glass, condenser and measurement instruments. The sight-glass for flow pattern observations was located at the outlet of the pre-heater. The experiment was carried out to show the flow characteristics of R-22 and R-l34a. Data were taken with test conditions in the following ranges; the mass flux was ranged from 100 to 1,000 kg/$m^2s$, the saturation temperature was $30^{\circ}C$ and the vapor quality was ranged from 0.1 to 0.9. The main results were summarized as follows; In the flow patterns during evaporation, the annular flow in a 2 mm inner diameter tube occurred at a relatively lower quality and mass velocity, compared to the flow in a 8mm inner diameter tube. The evaporation flow in small diameter tubes has been shown major deviations with the Mandhane, Taitel-Dukler's and Wambs-ganss' flow pattern maps but it was similar to the Dobson's flow pattern map.

액주형 동축노즐 분무의 무화특성에 관한 실험적 연구 (An experimental study on the atomizing characteristics of liquid column type coaxial sprays)

  • 노병준;강신재;오제하
    • 오토저널
    • /
    • 제14권5호
    • /
    • pp.41-53
    • /
    • 1992
  • The main purpose of this study is to investigate the atomizing characteristics of a two phase spray by using a liquid column type coaxial nozzle. The experiments have been carried out to analyze the atomization behavior, the droplet size distributions, and the statistical properties of droplet size distributions. Immersion sampling method and the image processing technique were adapted for the measurements of particles, and the distributions of the droplet sizes were statistically analyzed. In the experiments, the mass ratio defined as Mr= $M_{\sigma}$/ $M_{1}$ has been changed from 1.0 to 3.4 and the measurements have been performed along the axis of the spray. As a result of this experimental study, the distributions of droplet size were satisfied with the Log-Normal distributions and arithmetic mean diameter and deviation of mass ratio. Droplet volume-surface mean diameter was denoted by a exponential function of mass-ratio and the exponent was denoted by linear relation according to the central axis from the nozzle. Dispersions, skewness factors and flatness factors had comparatively constant values regardless of mass ratio and location.

  • PDF

DISTRIBUTION OF FUEL MASS AFTER WALL IMPINGEMENT OF DIESEL SPRAY

  • Ko, K.N.;Huh, J.C.;Arai, M.
    • International Journal of Automotive Technology
    • /
    • 제7권4호
    • /
    • pp.493-500
    • /
    • 2006
  • Investigation on the fuel adhering on a wall was carried out experimentally to clarify the characteristics of impinging diesel sprays. Diesel sprays were injected into a high-pressure chamber of cold state and impinged to a wall having various impingement distances and ambient pressures. Photographs of both the fuel film and the post-impingement spray were taken through a transparent wall. Adhered fuel mass on a wall was measured by means of dividing into two types of fuel state: the fuel film itself; and sparsely adhered fuel droplets. Adhering fuel ratio was predicted and further the distribution of fuel mass for impinging diesel spray was analyzed as a function of time. As result, with an increase of the ambient pressure, both the maximum fuel film diameter and the adhered fuel ratio decreased. Based on some assumptions, the adhering fuel mass increased rapidly until the fuel film diameter approached the maximum value, and then increased comparatively gradually.

FUNDAMENTAL PARAMETERS OF NGC 2509 BASED ON 2MASS DATA

  • Tadross, A.L.
    • 천문학회지
    • /
    • 제38권3호
    • /
    • pp.357-363
    • /
    • 2005
  • A deep stellar analysis is introduced for the poorly studied open cluster NGC 2509. The Near-IR database of the digital Two Micron All Sky Survey (2MASS) has been used to re-estimate and refine the fundamental parameters of the cluster, i.e. age, reddening, distance, and diameter. As well as, luminosity function, mass function, total mass, relaxation time, and mass segregation of NGC 2509 have been estimated here for the first time..

초기 횡방향 유동이 존재하는 충돌제트/유출냉각에서 요철이 설치된 유출면에서의 열/물질전달 특성 (Heat/Mass Transfer Characteristics on Rib-roughened Surface for Impingement/Effusion Cooling System with Initial Crossflow)

  • 이동호;남용우;조형희
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.338-348
    • /
    • 2004
  • The present study is conducted to investigate the effect of rib arrangements on an impingement/effusion cooling system with initial crossflow. To simulate the impingement/effusion cooling system, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of tile hole diameter. Initial crossflow passes between the injection and effusion plates, and the square ribs (3mm) are installed on the effusion plate. Both the injection and effusion hole diameters are 10mmand Reynolds number based on the hole diameter and hole-to-hole pitch are fixed to 10,000 and 6 times of the hole diameter, respectively. To investigate the effects of rib arrangements, various rib arrangements, such as 90$^{\circ}$transverse and 45$^{\circ}$angled rib arrangements, are used. Also, the effects of flow rate ratio of crossflow to impinging jets are investigated. With the initial crossflow, locally low transfer regions are formed because the wall jets are swept away, and level of heat transfer rate get decreased with increasing flow rate of crossflow. When the ribs are installed on the effusion plate, the local distributions of heat/mass transfer coefficients around the effusion holes are changed. The local heat/mass transfer around the stagnation regions and the effusion holes are affected by the rib positions, angle of attack and rib spacing. For low blowing ratio, the ribs have adverse effects on heat/mass transfer, but for higher blowing ratios, higher and more uniform heat transfer coefficient distributions are obtained than the case without ribs because the ribs prevent the wall jets from being swept away by the crossflow and increase local turbulence of the flow near the surface. Average heat transfer coefficients with rib turbulators are approximately 10% higher than that without ribs, and the higher values are obtained with small pitch of ribs. However, the attack angle of the rib has little influence on the average heat/mass transfer.

회전하는 사각덕트 유로에서 벽면 유출홀에 따른 열전달 특성 변화( ll ) -유출유량 변화에 따른 영향 - (Change of Heat Transfer Characteristics in a Rotating Channel of . Square Duct at Wall with Bleed Holes ( II ) - Effects of Exit Mass Flow Rate -)

  • 김상인;김경민;이동현;전윤흥;조형희
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.907-913
    • /
    • 2005
  • The present study has been conducted to investigate convective heat/mass transfer in the cooling passage with bleed holes. The rotating square channel has 40.0 mm hydraulic diameter and the bleed holes on the leading surface of the channel. The hole diameter of bleed hole is 4.5mm and its spacing is ( p/d:4.9) about five times of hole diameter. Exit mass flow rate through bleed holes is $0\%,\;10\%\;and\;20\%$ of the main mass flow rate respectively. rotation number is fixed 0.2. A naphthalene sublimation technique is employed to determine the detailed local heat transfer coefficients using the heat and mass transfer analogy. The cooling performance is influenced by exit mass flow rate through bleed holes and Coriolis force of rotating channel for fixed Reynolds number. The heat transfer on the leading surface is decreased due to Coriolis force. However the total heat transfer is enhanced around holes on the leading surface because of trapping flow by bleeding.

공기운반분무기용 세라믹 노즐의 미립화 성능 (The Atomization Performance of Ceramic Nozzles in Air Carrier Sprayer)

  • 박석호;노수영
    • Journal of Biosystems Engineering
    • /
    • 제20권3호
    • /
    • pp.236-244
    • /
    • 1995
  • Droplet size is one of the important factors in the deposition and drift of agrichemical application. In this study, droplet size and its distribution of the three different sizes of ceramic hollow cone nozzles being used in the air carrier sprayer for apple production were investigated at the various nozzle pressures and the three air velocities. The Malvern particle size analyzer were used for the measurement of droplet size and its distribution. The important results emerged from th is study can be summarized as follows. 1. Discharged rate was increase with the increase of the nozzle diameter and pressure, amount of the difference was remarkable between the nozzle diameter of 1.0, 1.2 and 1.5 mm, but no difference were found between the diameter of 1.0 and 1.2 mm in the same nozzle pressure. 2. Mass median diameter were varied as 40~160 ${mu}m$ at the air velocity of 0 m/s, 70~140 ${mu}m$ of 15 m/s and 100~160 ${mu}m$ of 20 m/s 3. It appeared that the air velocity range of 15~20 m/s was desirable for both drift and deposition control in the given experimental conditions.

  • PDF

제주지역 미세먼지의 오염원 규명에 관한 연구 (A Study on the Source Apportionment of the Atmospheric Fine Particles in Jeju area)

  • Hu, Chul-Goo;Yang, Su-Mi;Lee, Ki-Ho
    • 한국환경과학회지
    • /
    • 제12권2호
    • /
    • pp.217-225
    • /
    • 2003
  • Samples of size-fractionated PM10 (airborne particulate matter with aerodynamic diameter less than $10\mu\textrm{m}$) were collected at an urban site in Jeju city from May to September 2002. The mass concentration and chemical composition of the samples were measured. The data sets were then applied to the CMB receptor model to estimate the source contribution of PM10 in Jeju area. The average PM10 mass concentration was 28.80$\mu\textrm{g}/m^3$ ($24.6~33.49\mu\textrm{g}/m^3$), and the FP (fine particle with aerodynamic diameter less than $2.l\mu\textrm{m}$ fraction in PM10 was approximately 8% higher than the CP (coarse particle with aerodynamic diameter greater than $2.l\mu\textrm{m}$ and less than $10\mu\textrm{m}$ fraction in PM10. The CP composition was obviously different from the FP composition, that is, the most abundant water soluble species was nitrate ion in the FP, but sulfate ion in the CP. Also sulfur was the most dominant element in the FP, however, sodium was that in the CP. From CMB receptor model results, it was found that road dust was the largest contributor to the CP mass concentration (45% of the CP) and ammonium nitrate, domestic boiler, and marine aerosol were major sources to the CP mass. However, the secondary aerosol was the most significant contributor to the FP mass concentration (45% of the FP). In this study, it was suggested that the contributions of soil dust and gasoline vehicle became very low due to collinearity with road dust and diesel vehicle, respectively.

Parametric study of a new tuned mass damper with pre-strained SMA helical springs for vibration reduction

  • Hongwang Lv;Bin Huang
    • Smart Structures and Systems
    • /
    • 제31권1호
    • /
    • pp.89-100
    • /
    • 2023
  • This paper conducts a parametric study of a new tuned mass damper with pre-strained superelastic SMA helical springs (SMAS-TMD) on the vibration reduction effect. First, a force-displacement relation model of superelastic SMA helical spring is presented based on the multilinear constitutive model of SMA material, and the tension tests of the six SMA springs fabricated are implemented to validate the mechanical model. Then, a dynamic model of a single floor steel frame with the SMAS-TMD damper is set up to simulate the seismic responses of the frame, which are testified by the shaking table tests. The wire diameter, initial coil diameter, number of coils and pre-strain length of SMA springs are extracted to investigate their influences on the seismic response reduction of the frame. The numerical and experimental results show that, under different earthquakes, when the wire diameter, initial coil diameter and number of coils are set to the appropriate values so that the initial elastic stiffness of the SMA spring is between 0.37 and 0.58 times of classic TMD stiffness, the maximum reduction ratios of the proposed damper can reach 40% as the mass ratio is 2.34%. Meanwhile, when the pre-strain length of SMA spring is in a suitable range, the SMAS-TMD damper can also achieve very good vibration reduction performance. The vibration reduction performance of the SMAS-TMD damper is generally equal to or better than that of the classic optimal TMD, and the proposed damper effectively suppresses the detuning phenomena that often occurs in the classic TMD.

정중선 이소성 갑상선에서 주사상의 변화 추적 - 증례보고 - (A Changing Pattern of Isotope Scan of the Midline Ectopic Thyroid - A Case Report -)

  • 김갑태;김완섭;정을삼
    • Advances in pediatric surgery
    • /
    • 제2권2호
    • /
    • pp.133-137
    • /
    • 1996
  • A 17 month-old girl presented in the pediatric clinic on November 27th, 1990 with a neck mass. The mass was 2 cm in diameter, firm in consistency and movable on the upper pole of the thyroid cartilage in the midline. The technetium thyroid scan showed a hot reactivity at the compatible site of the mass, but no other radioactivity in either site of the normal thyroid positions. At her second visit on January 23th, 1996, the mass had enlarged up to 3.5cm in diameter in the same location of the neck. The follow up thyroid scan revealed a walnut sized, snowman-like radioactivity. One of the snowman-like double images seemed to be a lingual ectopic thyroid and the other a midline ectopic thyroid remnant in the infrahyoid level. This interpretation was supported by the computed tomography of the neck, which showed a ligual mass in the foramen cecum area and an another mass in the anterior comis-sure of the larynx in the mildline. Thyroid function test was normal except a slightly increased TSH. As a result of this changing pattern of thyroid radioactive images, a case of a lingual thyroid as well as another midline ectopic thyroid tissue at the infrahyoid level is reported.

  • PDF