• 제목/요약/키워드: Diagonal tensile(Shear) strength

검색결과 36건 처리시간 0.018초

석탄회 인공경량골재를 사용한 고강도 콘크리트 보의 전단성능 (Shear Performance of High-Strength Reinforced Concrete Beams using Fly-Ash Artificial Lightweight Aggregate)

  • 정수영;윤현도;박완신
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권4호
    • /
    • pp.233-242
    • /
    • 2002
  • This study is to investigate experimentally the shear capacity of high-strength lightweight-aggregate reinforced concrete beams subjected to monotonic loading. Ten beams made of fly-ash artificial lightweight high-strength concrete were tested to determine their diagonal cracking and ultimate shear capacities. The variables in the test program were longitudinal reinforcement ratio; which variabled (between 0.83 and 1.66 percent), shear span-to-depth ratio (a/d=1.5, 2.5 and 3.5), and web reinforcement(0, 0.137, 0.275 and 0.554 percent). Six of the test beams had no web reinforcement and the other six had web reinforcement along the entire length of the beam. Most of beams failed brittly by distinct diagonal shear crack, and have reserved shear strength due to the lack of additional resisting effect by aggregate interlocking action after diagonal cracking. Test results indicate that the ACI Building Code predictions of Eq. (11-3) and (11-5) for lightweight concretes are unconservative for beams with tensile steel ratio of 1.66, a/d ratios greater than 2.5 without web reinforcement. Through a more rational approach to compute the contribution of concrete to the shear capacity, a postcracking shear strength in concrete is observed.

강섬유 혼입율이 강섬유보강 고강도 콘크리트의 작업성과 강도특성에 미치는 영향 (Influence of Steel Fiber Volume Ratios on Workability and Strength Characteristics of Steel Fiber Reinforced High-Strength Concrete)

  • 김윤일;이양근;김명성
    • 한국건축시공학회지
    • /
    • 제8권3호
    • /
    • pp.75-83
    • /
    • 2008
  • In this paper, concrete material tests were carried out to investigate influence of steel fiber volumn ratios on variations of workability and strength characteristics of steel fiber reinforced high-strength concrete, $50MPa{\sim}90MPa$ of compressive strength, according to increase of fiber volume. Test specimens were arranged with six levels of concrete compressive strength and fiber volumn ratios, 0.0%, 0.5%, 1.0%, 1.5%, 2.0%. The test results showed that steel fiber reinforced high-strength concrete($70MPa{\sim}90MPa$, 1.5% fiber volumn ratio) with good workability of slump 20cm could be used practically and effects of steel fiber reinforcement in improvement of concrete strength and toughness characteristics such as splitting tensile strength, flexural strength, and diagonal tensioned shear strength, were more distinguished in high-strength concrete than general strength concrete. And the test results indicated that splitting tensile strength of fiber reinforced concrete was proportioned to the product of steel fiber volumn ratios, $V_f(%)$ and sqare root of compressive strength, $\sqrt{f_{ck}}$, and the increasing rate was in contrast with that of flexural strength, and increase of diagonal tensioned shear strength was remarkable at steel fiber volumn ratio, 0.5%.

고강도 경량콘크리트를 사용한 철근콘크리트 T 형보의 전단성능 (A Study on Shear Capacity of High Strength Lightweight Reinforced Concrete T-Beams)

  • 김진수;김원호;박성무
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.220-225
    • /
    • 1993
  • This paper is an experimental study on shear capacity of the high strength lightweight reinforced concrete beams with shear-depth ratio between 1.5 and 2.5. Thirteen T & rectangular beams were tested to determine their diagonal cracking and ultimate shear capacity. The major variables are shear span-depth ratio (a/d=1.5, 2.0, 2.5), concrete compressive strength(f'c=210, 24., 270㎏/㎠) and tensile steel ratio( =0.6, 1.2%). Based on results obtained from experiment of high strength lightweight reinforced concrete Beam & normal concrete, the following conclusions were drawn. (1) The shear capacity of high-strength lightweight concrete is less 15% than that of normal concrete under same condition. (2) As the results of Comparing this experimental datas with other various formulas. It is regarded that ACI 318-89 shear strength formula related tensile strength is proper to design formula of shear strength of high-strength lightweight reinforced concrete using lightweight concrete.

  • PDF

Diagonal Tension Failure Model for RC Slender Beams without Shear Reinforcement Based on Kinematical Conditions (I) - Development

  • 유영민
    • 한국해양공학회지
    • /
    • 제21권6호
    • /
    • pp.7-15
    • /
    • 2007
  • A mechanical model was developed to predict the behavior of point-loaded RC slender beams (a/d > 2.5) without stirrups. It is commonly accepted by most researchers that a diagonal tension crack plays a predominant role in the failure mode of these beams, but the failure mechanism of these members is still debatable. In this paper, it was assumed that diagonal tension failure was triggered by the concrete cover splitting due to the dowel action at the initial location of diagonal tension cracks, which propagate from flexural cracks. When concrete cover splitting occurred, the shape of a diagonal tension crack was simultaneously developed, which can be determined from the principal tensile stress trajectory. This fictitious crack rotates onto the crack tip with load increase. During the rotation, all forces acting on the crack (i.e, dowel force of longitudinal bars, vertical component of concrete tensile force, shear force by aggregate interlock, shear force in compression zone) were calculated by considering the kinematical conditions such as crack width or sliding. These forces except for the shear force in the compression zone were uncoupled with respect to crack width and sliding by the proposed constitutive relations for friction along the crack. Uncoupling the shear forces along the crack was aimed at distinguishing each force from the total shear force and clarifying the failure mechanism of RC slender beams without stirrups. In addition, a proposed method deriving the dowel force of longitudinal bars made it possible to predict the secondary shear failure. The proposed model can be used to predict not only the entire behavior of point-loaded RC slender shear beams, but also the ultimate shear strength. The experiments used to validate the proposed model are reported in a companion paper.

주인장 철근을 가진 HPFRCC 보 부재 전단 강도 예측 모델 (Shear Strength Model for HPFRCC Beams with Main Longitudinal Tensile Reinforcements)

  • 이성철;신경준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권2호
    • /
    • pp.60-67
    • /
    • 2020
  • 최근 HPFRCC의 구조 거동에 대한 연구가 많이 이루어져 왔으나, 휨 거동에 대한 연구가 주로 수행된 반면, 전단 거동에 대한 연구는 많이 부족한 상황이다. 이 연구에서는 전단 철근이 없는 HPFRCC 보 부재의 전단 강도를 합리적으로 예측할 수 있는 모델을 개발하였다. 모델을 개발하기 위해 HPFRCC 보 부재를 휨 모멘트에 저항하는 상·하현재와 전단력에 저항하는 복부 전단 요소로 간단히 이상화하였다. 이후 HPFRCC의 인장 거동 특성을 바탕으로 전단 파괴 시 복부 전단 요소의 주압축대 기울기 및 전단 응력을 산정하였으며, 이로부터 HPFRCC 보부재의 전단 강도를 산정할 수 있는 모델을 제안하였다. 제안 모델의 검증을 위해 기존의 전단 파괴된 48개의 HPFRCC 보 부재의 실험 결과와 비교하였다. 실험과 비교한 결과, 제안 모델이 실제 전단 강도를 평균 1.045, 변동계수 0.125로서 상당히 합리적으로 예측하는 것으로 나타났다. 이 연구의 주요 내용은 향후 HPFRCC가 적용되는 부재 또는 구조물에 대한 관련 연구 및 설계에 유용할 것으로 기대된다.

횡보강근이 없는 콘크리트 부재의 전단강도 (Shear Strength of Concrete Members without Transverse Steel)

  • 김장훈
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.57-66
    • /
    • 2000
  • The truss analogy for the analysis of beam-columns subjected of shear and flexure is limited by the contribution of transverse and longitudinal steel and diagonal concrete compression struts. However, it should be noted that even though the behavior of reinforced concrete beam-columns after cracking can be modeled with the truss analogy, they are not perfect trusses but still structural elements with a measure of continuity provided by a diagonal tension field. The mere notion of compression field denotes that there should be some tension field coexisting perpendicularly to it. The compression field is assumed to form parallel to the crack plane that forms under combined flexure and shear. Therefore, the concrete tension field may be defined as a mechanism existing across the crack and resisting crack opening. In this paper, the effect of concrete tensile properties on the shear strength and stiffness of reinforced concrete beam-columns is discussed using the Gauss two-point truss model. The theoretical predictions are validated against the experimental observations. Although the agreement is not perfect, the comparison shows the correct trend in degradation as the inelasticity increases.

합성 전단벽에 대한 대각 압축 응력장 접근법

  • 이어진;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.5-6
    • /
    • 2010
  • 본 연구에서는 균열 이후의 콘크리트 벽체에 대해 대각 일축 압축장과 세 삼각형으로 구성된 두 개의 균질한 삼각형 응력장을 고려하고, 이에 대해 직각방향으로 발생되는 강판의 인장응력의 조합을 가정하여 세장한 합성 전단벽의 전단강도를 추정하는 것을 목적으로 한다.

  • PDF

A study on the Interfacial Properties of Electrodeposited Single Carbon Fiber/Epoxy Composites Using Tensile and Compressive Fragmentation Tests

  • Park, Joung-Man;Kim, Jin-Won
    • Macromolecular Research
    • /
    • 제10권1호
    • /
    • pp.24-33
    • /
    • 2002
  • Interfacial and microfailure properties of carbon fiber/epoxy composites were evaluated using both tensile fragmentation and compressive Broutman tests. A monomeric and two polymeric coupling agents were applied via the electrodeposition (ED) and the dipping applications. A monomeric and a polymeric coupling agent showed significant and comparable improvements in interfacial shear strength (IFSS) compared to the untreated case under both tensile and compressive tests. Typical microfailure modes including cone-shaped fiber break, matrix cracking, and partial interlayer failure were observed under tension, whereas the diagonal slipped failure at both ends of the fractured fiber appeared under compression. Adsorption and shear displacement mechanisms at the interface were described in terms of electrical attraction and primary and secondary bonding forces.

전단경간비와 주인장철근비가 철근콘크리트 보의 최소전단철근비에 미치는 영향 (Effects of Shear Span-to-depth Ratio and Tensile Longitudinal Reinforcement Ratio on Minimum Shear Reinforcement Ratio of RC Beams)

  • 이정윤;김욱연;김상우;이범식
    • 콘크리트학회논문집
    • /
    • 제16권6호
    • /
    • pp.795-803
    • /
    • 2004
  • 현행 구조설계기준식에서는 취성적으로 파괴하는 최소전단보강철근 파괴를 방지하기 위하여 철근콘크리트 보에 최소전단보강철근을 배근하도록 규정하고 있다. 최소전단철근비는 콘크리트의 압축강도와 함께 주인장철근비와 전단경간비에 영향을 받는다. 이 연구에서는 주인장철근비와 전단경간비가 철근콘크리트 보의 최소전단철근비에 미치는 영향을 파악하기 위하여 14개의 철근콘크리트 보를 실험하였다. 실험에 의하면 전단 여유율은 주인장철근비가 증가할수록 증가하였고, 전단경간비가 증가할수록 감소하였다. 실험 결과는 ACI 318-02 기준식과 선행 연구의 제안식과 비교되었다.

산업부산물을 활용한 고강도 경량콘크리트 보의 전단강도에 대한실험 연구 (Experimental Studies on Shear Strength of High-Strength Lightweight Concrete Beam using the Industrial by-products)

  • 이승조;박정민;김화중
    • 콘크리트학회논문집
    • /
    • 제18권5호
    • /
    • pp.621-630
    • /
    • 2006
  • 산업부산물을 활용한 고강도 경량 콘크리트 보의 역학적 거동 구명과 함께 경량 콘크리트 보의 이론식을 바탕으로 합리적인 전단강도식을 제안하였다. 보는 경량 골재를 사용한 고강도 경량 콘크리트 보(L) 8개와 일반 골재를 사용한 고강도콘크리트 보(H) 4개의 실험체를 제작하였다. 그리고 전단스팬비(a/b=1.5, 2.5, 3.5, 4.5), 인장철근비(${\rho}$=0.57, 1.0, 1.59, 2.3%), 콘크리트의 압축강도(35.4, 65.3MPa)를 주요 변수로 설정하여 실험하였다. 이로부터 보에 대한 하중-처짐관계 및 변형률 분포, 파괴성상, 최대내력 등에 대하여 측정하였다. 또한 보의 전단강도식의 제안을 위하여 사인장 균열 강도와 극한전단강도로 세분화하여 기존 제안식과 규준식에 적용시켜 상호 비교 분석을 하였다. $V_{cr}$에 있어서는 a/b=2.5 이상에서는 ACI 규준식과 Zsutty제안식에서 감소하는 결과였지만, Mathey의 제안식에서는 약간의 상승 경향을 보였다. 또한, ${\rho},\;f_c$의 증가에 따라 $V_{cr,\exp}/V_{cr,cal}$은 과대평가의 경향이 나타났다. 한편, $V_{u, \exp}/V_{u,cal}$에서는 통계적인 방법으로 유도된 Zsutty의 제안식이 실험결과와의 일치성에서 좋은 결과를 보였다. 이 식으로부터 유도 수정된 전단강도에 대한 제안식은 $V_{cr},\;V_u$에서 합리적으로 예측할 수 있음을 알 수 있었다. 따라서 본 연구에서 제안된 전단강도 식은 경량 콘크리트의 전단스팬비, 인장철근비, 콘크리트 압축강도의 변화에 따른 전단내력을 합리적으로 평가하는데 유용하게 활용될 수 있을 것으로 사료된다.