• 제목/요약/키워드: Diagnostic ultrasound

검색결과 434건 처리시간 0.039초

Diagnostic Performance of Core Needle Biopsy for Characterizing Thyroidectomy Bed Lesions

  • So Yeong Jeong;Jung Hwan Baek;Sae Rom Chung;Young Jun Choi;Dong Eun Song;Ki-Wook Chung;Won Woong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • 제23권10호
    • /
    • pp.1019-1027
    • /
    • 2022
  • Objective: Thyroidectomy bed lesions frequently show suspicious ultrasound (US) features after thyroid surgery. Fine-needle aspiration (FNA) may not provide definitive pathological information about the lesions. Although core-needle biopsy (CNB) has excellent diagnostic performance in characterizing suspicious thyroid nodules, no published studies have evaluated the performance of CNB specifically for thyroidectomy bed lesions. Therefore, we aimed to evaluate the diagnostic performance and safety of CNB for characterizing thyroidectomy bed lesions. Materials and Methods: A total of 124 thyroidectomy bed lesions in 113 patients (79 female and 34 male; age, 23-85 years) who underwent US-guided CNB between December 2008 and December 2020 were included. We reviewed the US imaging features of the target lesions and the histories of previous biopsies. The pathologic results, diagnostic performance for malignancy, and complications of CNB were analyzed. Results: All samples (100%) obtained by CNB were adequate for pathological analysis. Pathological analysis revealed inconclusive results in two lesions (1.6%). According to the reference standard, 50 lesions were ultimately malignant (40.3%), and 72 were benign (58.1%), excluding the two inconclusive lesions. The performance of CNB for diagnosing malignant thyroidectomy bed lesions in the 122 lesions had a sensitivity of 98.0% (49/50), a specificity of 100% (72/72), positive predictive value of 100% (49/49), and negative predictive value of 98.6% (72/73). Eleven lesions were referred for CNB after prior inconclusive FNA results in thyroidectomy bed lesions, for all of which CNB yielded correct conclusive pathologic diagnoses. According to the pathological analysis of CNB, there were various benign lesions (58.9%, 73/124) besides recurrence, including benign postoperative lesions other than suture granuloma (32.3%, 40/124), suture granuloma (15.3%, 19/124), remnant thyroid tissue (5.6%, 7/124), parathyroid lesions (4%, 5/124), and abscesses (1.6%, 2/124). No major or minor complications were associated with the CNB procedure. Conclusion: US-guided CNB is accurate and safe for characterizing thyroidectomy bed lesions.

한의사의 면허 외 행위 판단 기준에서 "진단의 보조 수단"의 의미 - 대법원 2023. 8. 18. 선고 2016두51405 판결 - (Meaning of "an auxiliary method of diagnosis" in the judgment of unlicensed medical practice by Korean medical doctors - Supreme Court Decision 2016Du51405 on August 18, 2023 -)

  • 최혁용
    • 의료법학
    • /
    • 제24권3호
    • /
    • pp.125-153
    • /
    • 2023
  • 대법원 2022. 12. 22. 선고 2016도21314 전원합의체 판결은 한의사의 진단용 의료기기 사용이 면허된 것 이외의 의료행위에 해당하는지를 판단하는 새로운 기준을 제시하고, 이 기준에 따라 한의사의 초음파 사용을 무면허 의료행위가 아니라고 판단하였다. 대법원 2023. 8. 18. 선고 2016두51405 판결은 새로운 판단기준을 적용하여 뇌파계를 파킨슨병과 치매 진단에 사용한 행위가 한의사로서 면허된 것 이외의 의료행위에 해당하지 않는다고 판단한 첫 번째 사안이다. 대법원은 판례변경을 통해 의료기기 사용에 서양 의학적 지식과 기술이 필요하지 않아야 한다는 종전 기준을 폐기하였지만, 진단용 의료기기를 사용한 한의사의 서양 의학적 진단행위를 진단의 보조수단으로 볼 것인지는 불투명한 상태였다. 이에 대법원은 뇌파계를 활용하여 파킨슨병과 치매, 즉 서양 의학적 진단을 한 한의사의 행위를 면허된 것 이외의 의료행위가 아니라고 판단함으로써 진단의 보조수단이 가지는 의미를 명확히 정리하였다. 이외에도 대상 판결은 뇌파계의 개발, 제작 원리와 뇌파계 검사 결과의 자동 추출 및 자동 판독 여부 또한 판단기준에서 배제함으로써 한방의료행위의 의미가 수범자인 한의사의 관점에서 명확하고 엄격하게 해석되어야 한다는 죄형법정주의 관점을 더욱 투철하게 적용하고 진단용 의료기기가 한의학적 의료행위 원리와 관련 없음이 명백한 경우가 아닌 한 형사처벌 대상에서 제외됨을 분명히 하였다.

심장전산화단층촬영을 이용한 관상동맥 죽상경화반의 분류 : 혈관내초음파 결과를 통한 후향적 분석 (Analysis of Coronary Artery Atheromatous Plaque by Cardiac Computed Tomographic Angiography : Retrospective Analysis of Intravascular Ultrasound Results)

  • 최재성;한재복;최남길
    • 한국콘텐츠학회논문지
    • /
    • 제12권10호
    • /
    • pp.349-356
    • /
    • 2012
  • 관상동맥 죽상경화반(atheromatous plaque)의 진단에 있어 혈관내초음파(Intravascular Ultrasound: IVUS)와 비교하여 심장전산화단층촬영(Cardiac Computed Tomographic Angiography: CCTA)의 진단 정확도를 알아보고, IVUS에서 발견된 죽상경화반의 성상을 CCTA에서 전산화단층촬영 수치(Hounsfield Unit: HU)로 구하고자 하였다. 2006년 4월부터 2008년 8월까지 관상동맥질환(Coronary Artery Disease: CAD)으로 확진 되었거나 CAD가 의심스러운 환자들 중 CCTA를 시행하여 죽상경화반을 발견하고 추후 IVUS를 시행한 200명의 환자를 대상으로 하였다. CCTA후 IVUS를 시행한 200명의 환자에서 476개의 죽상경화반이 발견되었으며, CCTA에서는 460개의 죽상경화반이 발견되었다. IVUS의 결과는 soft plaque(n; 84), fibrous plaque(n; 63), mixed plaque(n; 97), calcific plaque(n; 232)이었다. 이 결과에 따라 IVUS에서 분류된 죽상경화반의 HU는 soft plaque : $53.8{\pm}10.5$, fibrous plaque : $108.1{\pm}20.0$, mixed plaque : $371.2{\pm}113.1$, 그리고 calcific plaque : $731.0{\pm}160.4$ 이었으며, CCTA에서 민감도와 신뢰구간은 97%, 95.0-98.3이었다. CCTA를 이용한 관상동맥 죽상경화반의 진단을 위한 이번 연구에서 IVUS와 비교하여 높은 민감도와 신뢰구간을 확인할 수 있었고, IVUS 결과를 기준으로 CCTA에서 분석한 HU를 통해 죽상경화반의 성상을 구분할 수 있어 CAD 환자의 치료에 도움을 줄 수 있을 것으로 기대된다.

Incidence of Fever Following Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

  • Kim, Seo Yun;Lee, Jin woo;Park, Young Sik;Lee, Chang-Hoon;Lee, Sang-Min;Yim, Jae-Joon;Kim, Young Whan;Han, Sung Koo;Yoo, Chul-Gyu
    • Tuberculosis and Respiratory Diseases
    • /
    • 제80권1호
    • /
    • pp.45-51
    • /
    • 2017
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive diagnostic method for mediastinal and hilar lymphadenopathy. This study aimed to investigate the incidence of fever following EBUS-TBNA. Methods: A total of 684 patients who underwent EBUS-TBNA from May 2010 to July 2012 at Seoul National University Hospital were retrospectively reviewed. The patients were evaluated for fever by a physician every 6-8 hours during the first 24 hours following EBUS-TBNA. Fever was defined as an increase in axillary body temperature over $37.8^{\circ}C$. Results: Fever after EBUS-TBNA developed in 110 of 552 patients (20%). The median onset time and duration of fever was 7 hours (range, 0.5-32 hours) after EBUS-TBNA and 7 hours (range, 1-52 hours), respectively, and the median peak body temperature was $38.3^{\circ}C$ (range, $137.8-39.9^{\circ}C$). In most patients, fever subsided within 24 hours; however, six cases (1.1%) developed fever lasting longer than 24 hours. Infectious complications developed in three cases (0.54%) (pneumonia, 2; mediastinal abscess, 1), and all three patients had diabetes mellitus. The number or location of sampled lymph nodes and necrosis of lymph node were not associated with fever after EBUS-TBNA. Multiple logistic regression analysis did not reveal any risk factors for developing fever after EBUS-TBNA. Conclusion: Fever is relatively common after EBUS-TBNA, but is transient in most patients. However, clinicians should be aware of the possibility of infectious complications among patients with diabetes mellitus.

개에서 췌장염이 병발한 간외성 담관계 페쇄 치료를 위한 경피적 초음파 유도하 담낭 천자술 2예 (Percutaneous Ultrasound-Guided Cholecystocentesis for Treatment of Extrahepatic Biliary Tract Obstruction Concurrent with Pancreatitis in Two Dogs)

  • 조항묘;천행복;김주형;전혜영;김태훈;강지훈;한태성;나기정;양만표;김근형;장동우
    • 한국임상수의학회지
    • /
    • 제25권4호
    • /
    • pp.295-302
    • /
    • 2008
  • Two dogs were referred to Veterinary Medical Center, Chungbuk National University with the clinical signs of vomiting, diarrhea, anorexia, and jaundice. Both dogs were diagnosed as extrahepatic biliary tract obstruction(EHBO) with concurrent pancreatitis based on dilated common bile duct and hyperechoic or mixed-echoic pancreas in abdominal ultrasonographic examination and serum biochemical abnormalities, such as high serum bilirubin, cholesterol, and increased cholestatic enzyme activity. Percutaneous ultrasound-guided cholecytocentesis(PUCC) was performed to examine bile and decompress the gall bladder. After PUCC with medical therapy, both dogs were steadily improved clinical signs of jaundice and anorexia. Also, cholestatic enzyme activity and serum bilirubin concentration decreased. Any complications that have been described in previous studies, such as peritonitis resulting from bile leakage and hemorrhage, were not identified. It is assumed that percutaneous ultrasound guided cholecystocentesis may be an useful diagnostic and therapeutic tool in canine gallbladder disease and can be used easily and safely to gain bile for diagnosis of bacterial cholecytitis.

췌장 지방 침착 정도에 따른 초음파 영상 평가 (Ultrasonic image assessment of the degree of pancreatic fat deposition)

  • 박혜인;박승훈;백윤승;이선빈;이은솔;허영대;조진영;고성진
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.490-492
    • /
    • 2016
  • 췌장 초음파 영상은 췌장비대증, 췌장지방증, 췌장암 등을 진단하기 위해서 사용된다. 췌장지방증의 진단은 췌장 초음파 영상에서 비장 실질보다 췌장 에코음영이 밝아진 경우 지방이 침착된 것으로 판단한다. 그리고 췌장암의 초음파 영상에 관한 연구는 활발히 이루어 졌지만 췌장 지방증에 관한 연구 사례는 미흡하다. 또한 췌장지방증은 그 진단 기준이 모호하고 숙련자의 주관적인 진단에 따른 오류가 많다. 이에 본 연구에서는 정상과 지방췌장의 영상에 GLCM algorithm을 적용하여 영상의 특징을 추출하고 추출된 특징값을 parameter를 이용하여 정량적인 분석을 하였다. GLCM algorithm을 이용하여 정상 89증례, 중등도 89증례, 고도 89증례 총 영상 267증례에 관심영역($5{\times}5pixel$)을 설정하고, 각 영상에서 Autocorrelation, Sum average, Sum of squares, Sum varience 4가지 parameter를 이용하여 분석하였다.

  • PDF

견관절 전방 통증 환자에서 초음파 유도하 견쇄관절 소염약침요법 병행 치료의 효과: 후향적 연구 (The Effectiveness of Ultrasound-Guided Soyeom Pharmacopuncture Therapy at Acromioclavicular Joint of Shoulder in Patients with Anterior Shoulder Pain: A Retrospective Study)

  • 김상우;전동휘;김병준;박정욱;오민석
    • 한방재활의학과학회지
    • /
    • 제31권3호
    • /
    • pp.95-104
    • /
    • 2021
  • Objectives The purpose of this study was to observe effectiveness of ultrasound-guided Soyeom pharmacopuncture therapy at acromioclavicular joint of shoulder in patients with anterior shoulder pain. Methods We analyzed medical records of 9 patients hospitalized with anterior shoulder pain who had admitted to Department of Korean Rehabilitation Medicine, College of Korean Medicine, Daejeon University from March 1, 2021 to June 13, 2021. 9 patients were treated the treatment of Soyeom pharmacopuncture therapy on acromioclavicular joint under ultrasonic guidance with Korean medicine treatment (such as herbal medicine, acupuncture, moxabustion, etc). The study was conducted as a retrospective observation study which analyze the patient's medical records. We used numeric rating scale (NRS) to evaluate pain reduction and the shoulder range of motion (ROM) to evaluate function improvement twice (before pharmacopuncture treatment and 5 days later treatment). Statistical analysis was performed using the IBM SPSS Statistics version 25 program (IBM Co., Armonk, NY, USA). Results The average of numeric rating scale reduced statistically significantly from 5.56±1.13 to 3.11±1.36 (p=0.004). The average of shoulder flexion ROM increased statistically significantly from 166.67±8.17° to 175.00±8.37° (p<0.05). And the average of shoulder abduction ROM increased statistically significantly from 158.57±20.35° to 172.86±12.53° (p<0.05). Both NRS and shouler ROM showed statistically significantly improve after treatment. Conclusions This study shows ultrasound-guided Soyeom pharmacopuncture therapy at acromioclavicular joint of shoulder has a meaningful clinical effect on the improving shoulder pain and ROM especially on flexion and abduction.

초음파검사에서 인체모의 매질팬텀을 이용한 온도 변화와 TI MI 분석 (An Analysis of Temperature Change and TI MI using Tissue Mimicking Phantom in Ultrasonic Examination)

  • 전철민;한재복;곽종길;송종남
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.751-759
    • /
    • 2022
  • 현재 진단 초음파 및 건강검진 목적의 초음파 검사는 널리 이용되고 있고 건강보험 적용으로 더욱 증가 추세를 보이고 있다. 하지만 초음파검사의 위해성은 현재까지 명확히 밝혀진 바가 없어 초음파 검사 시 인체 조직의 온도가 상승하는 열효과를 알아보고자 본 연구에서는 인체 모의 매질 팬텀을 이용해 주파수, 모드별에 따른 표면과 심부 온도 변화를 시간별로 측정하였고 TI, MI 값도 비교하였다. 인체와 유사한 음향 특성 있는 카파 카라기난 분말과 고형화를 위해 염화칼륨을 소량 첨가하여 모의 팬텀 제작하였고 표면 온도계와 탐침용 온도계를 사용하여 표면과 심부 온도 변화를 측정하였다. 그 결과 저주파수를 사용하는 Convex Probe가 고주파를 사용하는 Linear Probe보다 높은 온도 상승을 보여 유의미한 차이를 보였고 표면에서 온도 상승이 가장 높았으며 1 cm의 낮은 깊이는 일시적 온도상승은 나타내지만 유의미한 온도변화는 없었다. 5 cm ~ 15 cm의 심부온도 변화는 없었으며 검사 시간동안 TI, MI값은 변화가 없었다. 이는 15분 실험동안 표면온도만 상승하였고 심부에는 온도변화가 없었기 때문에 인체에 유해할 만큼의 온도 변화를 나타내지 않을 것으로 사료되며 통상적인 진단초음파의 15분의 검사시간은 임상에서의 사용에는 무리가 없을 것으로 생각되지만 특정 부위의 장시간 검사는 온도 상승을 일으킬 수 있으므로 지양해야 될 것으로 사료된다.

축방향 서브 나이퀴스트 샘플링 기반의 횡탄성 영상 기법 (Shear-wave elasticity imaging with axial sub-Nyquist sampling)

  • 오우진;윤희철
    • 한국음향학회지
    • /
    • 제42권5호
    • /
    • pp.403-411
    • /
    • 2023
  • 탄성 영상과 미세 혈류 도플러 영상과 같은 기능성 초음파 영상은 조직의 기계적, 기능적 정보를 제공함으로써 진단 성능을 향상시킨다. 그러나 기능성 초음파 영상의 구현은 데이터 획득 및 처리 시 대용량 데이터 저장과 같은 한계를 야기한다. 본 논문에서는 효율적인 횡탄성 영상 기법을 위해 데이터 획득 양을 절감시키는 서브 나이퀴스트 접근법을 제안한다. 제안하는 방법은 기존 나이퀴스트 샘플링 속도보다 1/3배 낮은 샘플링 속도로 데이터를 획득하고, 주파수 스펙트럼의 주기성을 이용하여 대역 통과 필터링 기반의 보간을 통해 재구성된 Radio Frequency(RF) 신호를 사용하여 횡파 신호를 추적한다. 이때 RF 신호는 67 % 미만의 비대역폭으로 제한된다. 제안하는 접근법을 검증하기 위해 기존 샘플링 속도로 획득한 횡파 추적 데이터를 이용하여 서브 나이퀴스트 샘플링된 RF 신호를 재현하고, 기존 접근법과 횡파 속도 영상을 재구성한다. 정량적 평가를 위해 재구성한 횡파 속도 영상의 군속도, 대조도 잡음 비, 그리고 구조적 유사성 지수를 비교하였다. 우리는 서브 나이퀴스트 샘플링 기반 횡탄성 영상의 가능성을 정성적, 정량적으로 입증하였고, 향후 실시간 3차원 횡탄성 영상 기술에 유용하게 적용 가능할 것으로 기대된다.

애매한 초음파 결과를 보인 소아 환자에서 충수돌기염을 감별하는데 유용한 초음파 소견: 구조화 판독문에 기초한 분석 (Useful Ultrasound Findings of Pediatric Patients with Equivocal Results of Appendicitis: Analysis Based on a Structured Report Form)

  • 최지영;김혁중;장석기;김현진;연재우
    • 대한영상의학회지
    • /
    • 제82권1호
    • /
    • pp.182-193
    • /
    • 2021
  • 목적 애매한 초음파 결과를 보인 소아 환자들에서 충수돌기염을 감별하는 데 도움이 되는 초음파 소견들을 알아보고자 한다. 대상과 방법 2012년 11월부터 2017년 10월 사이에 충수돌기염이 의심되어 초음파를 시행한 소아 환자 중 애매한 결과를 보인 53명의 환자를 대상으로 하였다. 초음파 검사는 정해진 구조화 판독문을 사용했으며 충수돌기염의 가능성은 5가지로 분류되었다. 그중 3등급과 4등급을 애매한 결과로 간주하였다. 결과 53명의 환자 중 각각 25명(47.2%)과 28명(52.8%)이 3등급과 4등급으로 분류되었다. 각 초음파 소견 중 충수돌기 벽의 혈류 증가와 충수돌기 주변의 지방 침윤이 충수돌기염을 진단하는 데 다변량 로지스틱 회귀분석에서 의미 있는 소견이었고(p = 0.005, p = 0.045), 진단적 정확도도 높았다(69.8%, 62.3%). 결론 충수돌기 벽의 혈류 증가와 충수돌기 주변의 지방 침윤은 애매한 초음파 결과를 보인 소아 환자들에서 의미 있는 충수돌기염의 예견 인자이다.