DOI QR코드

DOI QR Code

Diagnostic Performance of Core Needle Biopsy for Characterizing Thyroidectomy Bed Lesions

  • So Yeong Jeong (Department of Radiology, Hanyang University Medical Center, Hanyang University Medical College) ;
  • Jung Hwan Baek (Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Sae Rom Chung (Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Young Jun Choi (Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Dong Eun Song (Department of Pathology, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Ki-Wook Chung (Department of Surgery, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Won Woong Kim (Department of Surgery, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Jeong Hyun Lee (Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center)
  • Received : 2021.10.10
  • Accepted : 2022.06.30
  • Published : 2022.10.01

Abstract

Objective: Thyroidectomy bed lesions frequently show suspicious ultrasound (US) features after thyroid surgery. Fine-needle aspiration (FNA) may not provide definitive pathological information about the lesions. Although core-needle biopsy (CNB) has excellent diagnostic performance in characterizing suspicious thyroid nodules, no published studies have evaluated the performance of CNB specifically for thyroidectomy bed lesions. Therefore, we aimed to evaluate the diagnostic performance and safety of CNB for characterizing thyroidectomy bed lesions. Materials and Methods: A total of 124 thyroidectomy bed lesions in 113 patients (79 female and 34 male; age, 23-85 years) who underwent US-guided CNB between December 2008 and December 2020 were included. We reviewed the US imaging features of the target lesions and the histories of previous biopsies. The pathologic results, diagnostic performance for malignancy, and complications of CNB were analyzed. Results: All samples (100%) obtained by CNB were adequate for pathological analysis. Pathological analysis revealed inconclusive results in two lesions (1.6%). According to the reference standard, 50 lesions were ultimately malignant (40.3%), and 72 were benign (58.1%), excluding the two inconclusive lesions. The performance of CNB for diagnosing malignant thyroidectomy bed lesions in the 122 lesions had a sensitivity of 98.0% (49/50), a specificity of 100% (72/72), positive predictive value of 100% (49/49), and negative predictive value of 98.6% (72/73). Eleven lesions were referred for CNB after prior inconclusive FNA results in thyroidectomy bed lesions, for all of which CNB yielded correct conclusive pathologic diagnoses. According to the pathological analysis of CNB, there were various benign lesions (58.9%, 73/124) besides recurrence, including benign postoperative lesions other than suture granuloma (32.3%, 40/124), suture granuloma (15.3%, 19/124), remnant thyroid tissue (5.6%, 7/124), parathyroid lesions (4%, 5/124), and abscesses (1.6%, 2/124). No major or minor complications were associated with the CNB procedure. Conclusion: US-guided CNB is accurate and safe for characterizing thyroidectomy bed lesions.

Keywords

References

  1. Burgess JR, Tucker P. Incidence trends for papillary thyroid carcinoma and their correlation with thyroid surgery and thyroid fine-needle aspirate cytology. Thyroid 2006;16:47-53  https://doi.org/10.1089/thy.2006.16.47
  2. do Rosario PW, Fagundes TA, Maia FF, Franco AC, Figueiredo MB, Purisch S. Sonography in the diagnosis of cervical recurrence in patients with differentiated thyroid carcinoma. J Ultrasound Med 2004;23:915-920; quiz 921-922  https://doi.org/10.7863/jum.2004.23.7.915
  3. Lee YH, Lee NJ, Kim JH, Song JJ. US diagnosis of cervical recurrence in patients operated on thyroid cancer: sonographic features and clinical significance. Auris Nasus Larynx 2007;34:213-219  https://doi.org/10.1016/j.anl.2006.11.005
  4. Haugen BR, Alexander EK, Bible KC, Doherty GM, Mandel SJ, Nikiforov YE, et al. 2015 American Thyroid Association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer: the American Thyroid Association guidelines task force on thyroid nodules and differentiated thyroid cancer. Thyroid 2016;26:1-133  https://doi.org/10.1089/thy.2015.0020
  5. Bishop JA, Owens CL, Shum CH, Ali SZ. Thyroid bed fine-needle aspiration: experience at a large tertiary care center. Am J Clin Pathol 2010;134:335-339  https://doi.org/10.1309/AJCPD60AHRUCMDPF
  6. Frates MC, Parziale MP, Alexander EK, Barletta JA, Benson CB. Role of sonographic characteristics of thyroid bed lesions identified following thyroidectomy in the diagnosis or exclusion of recurrent cancer. Radiology 2021;299:374-380  https://doi.org/10.1148/radiol.2021201596
  7. Park DS, Cho JS, Park MH, Ryu YJ, Hwang MJ, Shin SH, et al. Malignant thyroid bed mass after total thyroidectomy. J Korean Surg Soc 2013;85:97-103  https://doi.org/10.4174/jkss.2013.85.3.97
  8. Shin JH, Han BK, Ko EY, Kang SS. Sonographic findings in the surgical bed after thyroidectomy: comparison of recurrent tumors and nonrecurrent lesions. J Ultrasound Med 2007;26:1359-1366  https://doi.org/10.7863/jum.2007.26.10.1359
  9. Yeon JS, Baek JH, Lim HK, Ha EJ, Kim JK, Song DE, et al. Thyroid nodules with initially nondiagnostic cytologic results: the role of core-needle biopsy. Radiology 2013;268:274-280  https://doi.org/10.1148/radiol.13122247
  10. Na DG, Kim JH, Sung JY, Baek JH, Jung KC, Lee H, et al. Core-needle biopsy is more useful than repeat fine-needle aspiration in thyroid nodules read as nondiagnostic or atypia of undetermined significance by the Bethesda system for reporting thyroid cytopathology. Thyroid 2012;22:468-475  https://doi.org/10.1089/thy.2011.0185
  11. Suh CH, Baek JH, Lee JH, Choi YJ, Kim JK, Sung TY, et al. The role of core-needle biopsy as a first-line diagnostic tool for initially detected thyroid nodules. Thyroid 2016;26:395-403  https://doi.org/10.1089/thy.2015.0404
  12. Kim JH, Lee JH, Shong YK, Hong SJ, Ko MS, Lee DH, et al. Ultrasound features of suture granulomas in the thyroid bed after thyroidectomy for papillary thyroid carcinoma with an emphasis on their differentiation from locally recurrent thyroid carcinomas. Ultrasound Med Biol 2009;35:1452-1457  https://doi.org/10.1016/j.ultrasmedbio.2009.04.009
  13. Ko MS, Lee JH, Shong YK, Gong GY, Baek JH. Normal and abnormal sonographic findings at the thyroidectomy sites in postoperative patients with thyroid malignancy. AJR Am J Roentgenol 2010;194:1596-1609  https://doi.org/10.2214/AJR.09.2513
  14. Shin JH, Baek JH, Chung J, Ha EJ, Kim JH, Lee YH, et al. Ultrasonography diagnosis and imaging-based management of thyroid nodules: revised Korean Society of Thyroid Radiology consensus statement and recommendations. Korean J Radiol 2016;17:370-395  https://doi.org/10.3348/kjr.2016.17.3.370
  15. Russ G, Bonnema SJ, Erdogan MF, Durante C, Ngu R, Leenhardt L. European Thyroid Association guidelines for ultrasound malignancy risk stratification of thyroid nodules in adults: the EU-TIRADS. Eur Thyroid J 2017;6:225-237  https://doi.org/10.1159/000478927
  16. Chung SR, Baek JH, Choi YJ, Sung TY, Song DE, Kim TY, et al. Diagnostic algorithm for metastatic lymph nodes of differentiated thyroid carcinoma. Cancers (Basel) 2021;13:1338 
  17. Baloch ZW, Barroeta JE, Walsh J, Gupta PK, Livolsi VA, Langer JE, et al. Utility of thyroglobulin measurement in fine-needle aspiration biopsy specimens of lymph nodes in the diagnosis of recurrent thyroid carcinoma. Cytojournal 2008;5:1 
  18. Borel AL, Boizel R, Faure P, Barbe G, Boutonnat J, Sturm N, et al. Significance of low levels of thyroglobulin in fine needle aspirates from cervical lymph nodes of patients with a history of differentiated thyroid cancer. Eur J Endocrinol 2008;158:691-698  https://doi.org/10.1530/EJE-07-0749
  19. Baldini E, Sorrenti S, Di Gioia C, De Vito C, Antonelli A, Gnessi L, et al. Cervical lymph node metastases from thyroid cancer: does thyroglobulin and calcitonin measurement in fine needle aspirates improve the diagnostic value of cytology? BMC Clin Pathol 2013;13:7 
  20. Chung SR, Baek JH, Choi YJ, Sung TY, Song DE, Kim TY, et al. The role of core needle biopsy for the evaluation of thyroid nodules with suspicious ultrasound features. Korean J Radiol 2019;20:158-165  https://doi.org/10.3348/kjr.2018.0101
  21. Ha EJ, Baek JH, Lee JH, Song DE, Kim JK, Shong YK, et al. Sonographically suspicious thyroid nodules with initially benign cytologic results: the role of a core needle biopsy. Thyroid 2013;23:703-708  https://doi.org/10.1089/thy.2012.0426
  22. Bin Saeedan M, Aljohani IM, Khushaim AO, Bukhari SQ, Elnaas ST. Thyroid computed tomography imaging: pictorial review of variable pathologies. Insights Imaging 2016;7:601-617  https://doi.org/10.1007/s13244-016-0506-5
  23. Park SH, Han JK, Lee CK, Jo SS, Kim HH, Bae WK, et al. Cervical thoracic duct cyst: a case report. J Korean Radiol Soc 2007;56:541-544  https://doi.org/10.3348/jkrs.2007.56.6.541
  24. Kang M, Ha SY, Cho HY, An J, Chung DH, Chung YS. Fine needle aspiration cytology of postoperative spindle cell nodule in neck after thyroidectomy: a case report. Korean J Pathol 2013;47:89-91  https://doi.org/10.4132/KoreanJPathol.2013.47.1.89
  25. Ku EJ, Park JW. A postoperative spindle cell tumor in the thyroid bed resembling recurrent papillary thyroid carcinoma: a 4.5-year follow-up case report. Int J Clin Exp Med 2020;13:8127-8131 
  26. Suh CH, Baek JH, Choi YJ, Kim TY, Sung TY, Song DE, et al. Efficacy and safety of core-needle biopsy in initially detected thyroid nodules via propensity score analysis. Sci Rep 2017;7:8242