• Title/Summary/Keyword: Diagnostic ultrasound

Search Result 434, Processing Time 0.02 seconds

Comparing the effectiveness of ultrasound guided versus blind genicular nerve block on pain, muscle strength with isokinetic device, physical function and quality of life in chronic knee osteoarthritis: a prospective randomized controlled study

  • Cankurtaran, Damla;Karaahmet, Ozgur Zeliha;Yildiz, Sadik Yigit;Eksioglu, Emel;Dulgeroglu, Deniz;Unlu, Ece
    • The Korean Journal of Pain
    • /
    • v.33 no.3
    • /
    • pp.258-266
    • /
    • 2020
  • Background: The genicular nerve block (GNB) is demonstrated from several reports to alleviate pain and improve knee functionality in patients with chronic knee osteoarthritis (OA). Ultrasound (US)-guided GNB has been the most used imaging method. This study aimed to compare the effectiveness of US-guided versus blind GNB in the treatment of knee OA. Methods: This prospective, randomized clinical trial included patients with knee OA based on American College of Rheumatology diagnostic criteria. The patients were evaluated for clinical and dynamometer parameters at the baseline, 4 weeks after treatment, and 12 weeks after treatment. The patients underwent blind injection or US-guided injection. Results: When compared with the baseline, both groups showed significant improvement in pain, physical function, and quality of life parameters. Significant differences were observed between the groups for clinical parameters (30-second chair stand test, 6-minute walk test) in favor of the US-guided group. On the other hand, blind injection was more significantly effective on some parameters of the Nottingham Health Profile. There wasn't any significant improvement in isokinetic muscle strength for either group. Conclusions: This study demonstrated that both US-guided and blind GNB, in the treatment of knee OA, were effective in reducing symptoms and improving physical function. GNB wasn't an effective treatment for isokinetic muscle function. US-guided injections may yield more effective clinical results than blind injections.

Ovarian volume is more closely related to the different manifestations of polycystic ovary syndrome than follicle number per ovary

  • Shazia Afrine;Jasmine Ara Haque;Md Shahed Morshed;Hurjahan Banu;Ahmed Hossain;Muhammad Abul Hasanat
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.50 no.3
    • /
    • pp.200-205
    • /
    • 2023
  • Objective: Polycystic ovary (PCO), a diagnostic component of polycystic ovary syndrome (PCOS), requires either an ovarian volume (OV) criterion or a follicle number per ovary (FNPO) criterion. This study investigated the association of OV and FNPO criteria with various manifestations of PCOS. Methods: This cross-sectional study was conducted at a university hospital among 100 patients newly diagnosed with PCOS (according to the revised Rotterdam criteria). Fasting blood samples were collected to measure glucose, total testosterone (TT), luteinizing hormone (LH), follicle-stimulating hormone (FSH), lipid, insulin, and hemoglobin A1c levels. An oral glucose tolerance test was performed. Transabdominal or transvaginal ultrasound of the ovaries was done, depending on patients' marital status. All investigations were conducted in the follicular phase of the menstrual cycle. OV >10 mL and/or FNPO ≥12 indicated PCO. A homeostasis model assessment of insulin resistance (IR) value ≥2.6 indicated IR, and metabolic syndrome (MS) was defined according to the international harmonization criteria. Results: Seventy-six participants fulfilled the OV criterion, 70 fulfilled the FNPO criterion, and 89 overall had PCO. Both maximum OV and mean OV had a significant correlation with TT levels (r=0.239, p=0.017 and r=0.280, p=0.005, respectively) and the LH/FSH ratio (r=0.212, p=0.034 and r=0.200, p=0.047, respectively). Mean OV also had a significant correlation with fasting insulin levels (r=0.210, p=0.036). Multivariate binary logistic regression analysis showed that IR (odds ratio [OR], 9.429; 95% confidence interval [CI], 1.701 to 52.271; p=0.010) and MS (OR, 7.952; 95% CI, 1.821 to 34.731; p=0.006) had significant predictive associations with OV alone, even after adjustment for age and body mass index. Conclusion: OV may be more closely related to the androgenic and metabolic characteristics of PCOS than FNPO.

The Utility of Contrast Enhanced Ultrasound and Elastography in the Early Detection of Fibro-Stenotic Ileal Strictures in Children with Crohn's Disease

  • Sarah D. Sidhu ;Shelly Joseph;Emily Dunn;Carmen Cuffari
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.26 no.4
    • /
    • pp.193-200
    • /
    • 2023
  • Purpose: Crohn's disease (CD) is a chronic, idiopathic bowel disorder that can progress to partial or complete bowel obstruction. At present, there are no reliable diagnostic tests that can readily distinguish between acute inflammatory, purely fibrotic and mixed inflammatory and fibrotic. Our aim is to study the utility of contrast enhanced ultrasound (CEUS) in combination with shear wave elastography (SWE) to differentiate fibrotic from inflammatory strictures in children with obstructive CD of the terminal ileum. Methods: Twenty-five (19 male) children between 2016-2021 with CD of the terminal ileum were recruited into the study. Among these patients, 22 had CEUS kinetic measurements of tissue perfusion, including wash-in slope (dB/sec), peak intensity (dB), time to peak intensity (sec), area under the curve (AUC) (dB sec), and SWE. In total, 11 patients required surgery due to bowel obstruction. Histopathologic analysis was performed by a pathologist who was blinded to the CEUS and SWE test results. Results: Patients that underwent surgical resection had significantly higher mean area under the curve on CEUS compared to patients responsive to medical therapy (p=0.03). The AUC also correlated with the degree of hypertrophy and the percent fibrosis of the muscularis propria, as determined by histopathologic grading (p<0.01). There was no difference in the mean elastography measurements between these two patient groups. Conclusion: CEUS is a useful radiological technique that can help identify pediatric patients with medically refractory obstructive fibrotic strictures of the terminal ileum that should be considered for early surgical resection.

Inter-device agreement between spectral domain optical coherence tomography, ultrasound biomicroscopy, and gonioscopy in evaluating the iridocorneal angle in normotensive dogs

  • Su An Kim;Jaeho Shim;Seonmi Kang;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.4
    • /
    • pp.34.1-34.12
    • /
    • 2023
  • Background: There has not been a thoroughly reported study of the comparison between spectral domain-optical coherence tomography (SD-OCT) with both ultrasound biomicroscopy (UBM) and gonioscopy on the evaluation of the iridocorneal angle (ICA) in dogs. Objectives: To investigate the diagnostic value of SD-OCT for the early detection of narrowing ICA by comparing and assessing inter-device agreement in anterior chamber angle (ACA) measurements obtained by SD-OCT and UBM, and ICA evaluations by gonioscopy. Methods: A total of 28 eyes from 28 client-owned dogs with normal intraocular pressure were included for examination. The ACA and angle opening distance (AOD) were measured from the SD-OCT and UBM images, and gonioscopy images were analyzed using the ICA grade and ZibWest angle index. Results: The mean ACA and AOD for SD-OCT were 28.31° ± 5.37° and 658.42 ± 219.90 ㎛, and for UBM, 28.34° ± 5.82° and 859.29 ± 221.80 ㎛, respectively. The mean difference in ACA between the average values of SD-OCT and UBM measurements was 0.03° with a 95% limit of agreement (LoA) span of 16.2°, indicating positive agreement; that in AOD was 200.85 ㎛ with a 95% LoA span of 1,110.95 ㎛, indicating poor agreement. The Pearson correlation coefficient of the ACA of SD-OCT and ZibWest indices of gonioscopy was 0.624, indicating strong agreement; that of UBM and gonioscopy was 0.43, indicating moderate agreement. Conclusions: SD-OCT is well tolerated by canine patients due to its non-contact method and might be an alternative option for early screening of ICA narrowing in clinical settings.

Breast Imaging Reporting and Data System (BI-RADS): Advantages and Limitations (유방영상 판독과 자료체계: 장점과 한계)

  • Ji Soo Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.3-14
    • /
    • 2023
  • Breast Imaging Reporting and Data System (BI-RADS) is a communication and data tracking system that standardizes and controls the quality of reporting by presenting lexicon descriptors, assessment categories, and recommendations for managing breast lesions. Using standardized terminology recommended by BI-RADS, radiologists can concisely and reproducibly communicate breast imaging results to clinicians. They can also provide the estimated malignant probability of the lesions found and guide management for them by determining the final assessment category. The limitations of BI-RADS 5th edition currently in use are that there are some areas for which standardized terminologies still need to be established, and that the diagnostic criteria of MRI assessment categories 3 and 4 are ambiguous compared to those for mammography or ultrasound. The next revision of BI-RADS is expected to include solutions for overcoming current limitations.

Incidental double duct sign: Should we be worried? Results from a long-term follow-up study

  • Lu Yao;Hoda Amar;Somaiah Aroori
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.28 no.1
    • /
    • pp.53-58
    • /
    • 2024
  • Backgrounds/Aims: Double duct sign (DDS) (dilated common bile and pancreatic duct) is synonymous with pancreatic head/peri-ampullary tumor (PHPAT). There is limited evidence on whether incidental DDS (I-DDS) is associated with an increased risk of malignancy. This study aimed to evaluate 5-year outcomes of I-DDS. Methods: Patients were categorized according to their risk of malignancy. 'Low-risk' patients, including those with I-DDS between 2010 and 2015, were analyzed in this study. The primary outcome was incidence of PHPAT within five years of identification of DDS. Histology results from endoscopic ultrasound-guided biopsy were considered diagnostic. Secondary outcomes were incidence of benign causes, extent of follow-up investigations, and clinical indicators of malignancy in patients with DDS. Results: Among 103 patients with DDS, 20 had I-DDS. Subsequent follow-up of these 20 patients found no patient with PHPAT, two (10%) patients with chronic pancreatitis, and 18 (90%) patients with no cause found. The median follow-up duration for 'low-risk' patients was 7.3 years (range, 6-11 years). The mean number of follow-up investigations per patient was two (range, 0-9). Investigations included computed tomography (n = 27), magnetic resonance cholangiopancreatography (n = 23), endoscopy (n = 16), and ultrasound (n = 14). Patients with jaundice were more likely to have malignancy (p < 0.01). Those with abdominal pain were more likely to have a benign cause (p < 0.01). Hyperbilirubinemia and/or deranged liver enzymes and raised CA19-9 were more likely to be associated with PHPAT (p < 0.01). Conclusions: Patients with I-DDS have a low risk of developing PHPAT within five years.

Combined Predictors of Long-Term Outcomes of Kasai Surgery in Infants with Biliary Atresia

  • Anna Degtyareva;Medan Isaeva;Elena Tumanova;Elena Filippova;Anna Sugak;Alexander Razumovsky;Nadezhda Kulikova;Marina Albegova;Denis Rebrikov
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.4
    • /
    • pp.224-235
    • /
    • 2024
  • Purpose: Biliary atresia (BA) is the leading cause of neonatal cholestasis (25-45%). The primary treatment is hepatic portoenterostomy (Kasai procedure), but only 20-40% provide long-term benefits. This study aimed to develop a predictive model for surgical efficacy by comparing preoperative and early postoperative indicators in infants with different outcomes. Methods: We enrolled 166 infants with BA (93 girls, 73 boys) who underwent the Kasai procedure between September 2002 and December 2021, dividing them into favorable or adverse outcome groups. Over 40 parameters were measured, and the diagnostic significance of the prognostic model was evaluated. Results: Kasai surgery was efficacious in 69 patients (42%) and non-efficacious in 97 (58%). Our model assesses efficacy by day 14 after surgery, improving on the <34 µmol/L direct bilirubin threshold established for 3-6 months after the procedure. Including the Desmet fibrosis score refined the model. Conclusion: Blood cholesterol below 5.41 mmol/L, direct bilirubin below 56.3 µmol/L on postoperative days 14±3, and a low Desmet score indicate a high probability of efficacious Kasai surgery in infants with BA.

Deep Learning-Based Lumen and Vessel Segmentation of Intravascular Ultrasound Images in Coronary Artery Disease

  • Gyu-Jun Jeong;Gaeun Lee;June-Goo Lee;Soo-Jin Kang
    • Korean Circulation Journal
    • /
    • v.54 no.1
    • /
    • pp.30-39
    • /
    • 2024
  • Background and Objectives: Intravascular ultrasound (IVUS) evaluation of coronary artery morphology is based on the lumen and vessel segmentation. This study aimed to develop an automatic segmentation algorithm and validate the performances for measuring quantitative IVUS parameters. Methods: A total of 1,063 patients were randomly assigned, with a ratio of 4:1 to the training and test sets. The independent data set of 111 IVUS pullbacks was obtained to assess the vessel-level performance. The lumen and external elastic membrane (EEM) boundaries were labeled manually in every IVUS frame with a 0.2-mm interval. The Efficient-UNet was utilized for the automatic segmentation of IVUS images. Results: At the frame-level, Efficient-UNet showed a high dice similarity coefficient (DSC, 0.93±0.05) and Jaccard index (JI, 0.87±0.08) for lumen segmentation, and demonstrated a high DSC (0.97±0.03) and JI (0.94±0.04) for EEM segmentation. At the vessel-level, there were close correlations between model-derived vs. experts-measured IVUS parameters; minimal lumen image area (r=0.92), EEM area (r=0.88), lumen volume (r=0.99) and plaque volume (r=0.95). The agreement between model-derived vs. expert-measured minimal lumen area was similarly excellent compared to the experts' agreement. The model-based lumen and EEM segmentation for a 20-mm lesion segment required 13.2 seconds, whereas manual segmentation with a 0.2-mm interval by an expert took 187.5 minutes on average. Conclusions: The deep learning models can accurately and quickly delineate vascular geometry. The artificial intelligence-based methodology may support clinicians' decision-making by real-time application in the catheterization laboratory.

Analysis of the Accuracy about Abdominal Ultrasonography and Clinical Chemical Test with Fatty Liver Patients on the Medical Examination (종합검진 후 지방간 환자의 복부 초음파 검사와 임상화학적 검사결과의 정확성 분석)

  • Kim, Young-Jae;Song, Jong-Nam;Kim, Min-Eui
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.183-189
    • /
    • 2012
  • Ultrasonography is one of the fields on the imaging studies within intra-abdominal organs. A blood test is a typical method of clinical chemical examination on the in vivo test of clinical symptoms. Fatty liver is performed simultaneously two kinds of diagnostics methods, intra-abdominal ultrasound and blood tests. At an implementing this, the standard of blood tests value was the TBIL, TC, AST, ALT, ALP, GGT, TG, HDL-C, GLU. In this study analyzing the accuracy of the two kinds of test, ultrasonography and blood test, on patients with fatty liver. From January to March 2012, patients 459 determined fatty liver within 1350, who received health examination simultaneously on the intra-abdominal ultrasonography and blood tests. Same result of ultrasonography and blood test's patients were 459 ie, 60.8%. and different result of those examinations was 280 ie, 39.2%. Consequently diagnostic accuracy was 60.8%. It presumably caused by differences in the diagnostic performance of ultrasound professionals(Radiologist or Radiological Technologist). In order to overcome this, ongoing educational and study will be needed.

The Clinical Usefulness of Ultrasound-Guided Fine Needle Aspiration Cytology in Thyroid Nodules (갑상선 결절에서 초음파 유도 미세침흡인검사의 임상적 유용성)

  • Kim, Mi-Young;Park, Young-Sun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.141-147
    • /
    • 2008
  • Thyroid nodules are a common disease in clinical practice. Fine needle aspiration (FNA) is an accurate and safe method for the diagnosis of thyroid nodules. One of the limitations of FNA is the variable rate of unsatisfactory specimens, especially in small sized, deep seated or complex cystic nodules. To overcome this problem, ultrasound-guided FNA (US-FNA) has been widely used. In this study, the clinical usefulness of US-FNA cytology in thyroid nodules was investigated. Female to male ratio was 6.58:1. The incidence of nodules were 157 (43.1%) cases on the right, 130 (35.7%) cases on the left and 9 (2.5%) cases in isthmus. Total 139 cases (38.2%) belong to less than 1cm and 225 cases (61.8%) belong to more than 1cm. As for the echo type in the nodules, solid types were 255(70.1%), cystic type 39 (10.7%) cases, and the percentage of mixed type was 19.2%. The results show that US-FNA reduces the possibility of unsatisfactory cytologic specimens and the rate of false-negative diagnosis, and improves the diagnostic accuracy in investigation thyroid nodules.

  • PDF