• Title/Summary/Keyword: Diagnostic ultrasound

Search Result 434, Processing Time 0.04 seconds

Malignant Anterior Uveal Melanoma Masquerading as Limbal Melanoma in a Shih-Tzu Dog with Recurrences of Hyphema

  • Susanti, Lina;Seo, Kangmoon;Kang, Seonmi
    • Journal of Veterinary Clinics
    • /
    • v.37 no.5
    • /
    • pp.282-285
    • /
    • 2020
  • A 14-year-old neutered-male Shih-Tzu was referred for glaucoma and hyphema accompanied by systemic hypertension. After topical corticosteroid and antiglaucoma medications, the left eye (OS) progressed phthisically, but ocular hypertension redevelop one-year-and-seven-months later. Suspected limbal melanoma developed in peripheral cornea/limbal sclera with heavily pigmented cornea OS. Ultrasound biomicroscopy and ocular ultrasonography differentiated ciliary body origin-heterogeneous mass from limbal mass. Persistent hyphema and pigmented cornea might obscure intraocular lesion and advanced diagnostic methods played a crucial role. Unlike the generally benign limbal melanoma, aggressive treatment was recommended for uveal tumor. Histopathology of enucleated OS confirmed malignant uveal melanoma with chronic hypertensive vasculopathy.

Bioengineering Approaches to Quantitation of Diagnosis and Treatment Monitoring for Patients with Liver Cancer: Ultrasonic Image Processing by Kalman Filtering (의공학적 기법에 의한 간암의 검진과 치료경과의 정량 : 칼만 필터링 기법에 의한 초음파 영상 처리)

  • 우광방;남상일
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.1
    • /
    • pp.5-12
    • /
    • 1985
  • In this paper Kalman filtering technique is applied to ultrasound signal to improve resolution capability, Ivhlch is in use of diagnostic imaging systems. The main advantage of Kalman filter algorithm for the analysis of reflected ultrasound signal is its recursive structure which can be easily adapted to tlme varing system. Because soft-tissues, such as liver, act as distributed acoustic low-pass filters which continually change the propagating pulse. tIne can put to practical use above advantage to find a suitable signal generallng model. In state-space description of the system, the 6th order system produces tl)e 1)esc spectral approximation to the source pulse As a result of spectrum analysis, 6th order estimator for two closely spaced ((p.5 mm) reflectors enhances resolution by 4dB-lOdB. By using this result, the possibility to detect even minute tumor is demonstrated.

  • PDF

Suppurative mastoid lymphadenitis mimicking mastoiditis: a case report

  • Tymofieiev, Oleksii O.;Ushko, Natalia O.;Fesenko, Ievgen I.;Tymofieiev, Olexander O.;Yarifa, Maria O.;Cherniak, Olha S.
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.5
    • /
    • pp.398-402
    • /
    • 2021
  • Mastoid lymph node inflammation is a rare entity. Pathological conditions in the vicinity of the mastoid processes can be challenging for maxillofacial head-neck surgeons to address. We report a case of suppurative mastoid lymphadenitis in an 18-year-old Caucasian male. To our knowledge, there are no publications that highlight the clinical, ultrasonographic, intra-, and postoperative data for any pathologic process that presented as mastoiditis.

Diagnosis of Nonmigrating Metallic Foreign Bodies in the Abdomen Using Ultrasound: An Alternative Approach Using a Traditional Method

  • Pak, Seong Min;Lee, Yeoun Joo;Hwang, Jae Yeon
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.1
    • /
    • pp.87-91
    • /
    • 2022
  • Ingestion of foreign bodies (FBs) is a common phenomenon among young children. Plain radiography is the first step diagnostic modality to detect the radio-opaque FBs. And computed tomography has been recommended by several guidelines as useful modalities for diagnosing ingested FBs. However, there is a risk of radiation exposure, making it burdensome to use in asymptomatic patients. Ultrasound (US) is not a commonly used technique for diagnosing ingested foreign bodies. However, US can provide real-time imaging with good resolutions without radiation exposure in pediatric patients. Herein, we report two pediatric cases of metallic foreign body ingestion that were successfully diagnosed using US for localizing foreign bodies. This study indicates that US may be used as an alternative method for detecting the localization of metallic foreign bodies in the gastrointestinal tract without exposure of radiation, particularly in pediatric patients.

Acoustic Power Measurement System of Array Probes for Ultrasonic Diagnostic Equipment Using Radiation Force Balance Methods (방사힘 측정법을 이용한 초음파 진단장치용 배열 탐침자의 음향파워 측정시스템)

  • Yun, Yong-Hyeon;Jho, Moon-Jae;Kim, Yong-Tae;Lee, Myoung-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.355-364
    • /
    • 2010
  • Considering biological safety, it is very important to measure acoustic power from ultrasonic array probe for diagnostic ultrasound imaging applications. In this paper, to measure acoustic power from each element on array probe for ultrasonic diagnostic equipment, we reconstruct and automate the acoustic power measurement system. The acoustic power from linear, phased and curved array were measured and analyzed. As a result of measurement, the effects caused by directivity of sound beam from curved array were founded. To remove these effects, we developed and applied the correction model. The proposed system is useful to evaluate characteristics of the acoustical output power of array probe.

Ulnar artery access for intracranial mechanical thrombectomy procedure: A salvage option after failed trans-femoral and trans-radial access

  • Muhammad U Manzoor;Abdullah A Alrashed;Ibrahim A Almulhim;Sultan Alqahtani;Fahmi Al Senani
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.4
    • /
    • pp.429-433
    • /
    • 2023
  • 84 years old gentle man with past medical history of hypertension and diabetes presented with sudden onset right sided weakness and aphasia for two hours. Initial neurological assessment revealed National Institute of Health Stroke Scale (NIHSS) 17. Computed tomography (CT) scan demonstrated minimal early ischemic changes along left insular cortex with occlusion of left middle cerebral artery (MCA). Based on clinical and imaging findings, decision was made to perform mechanical thrombectomy procedure. Initially, right common femoral artery approach was utilized. However, due to unfavorable type-III bovine arch, left internal carotid artery could not be engaged via this approach. Subsequently, access was switched to right radial artery. Angiogram revealed small caliber radial artery, with larger caliber ulnar artery. Attempt was made to advance the guide catheter through the radial artery, however significant vasospasm was encountered. Subsequently, ulnar artery was accessed and successful thrombolysis in cerebral infarction (TICI) III left MCA reperfusion was achieved with a single pass of mechanical thrombectomy via this approach. Post procedure neurological examination demonstrated significant clinical improvement. Doppler ultrasound 48 hours after the procedure demonstrated patent flow in radial and ulnar arteries with no evidence of dissection.

The Use of Diagnostic Ultrasound Devise by Oriental Medical Doctors (한의사의 초음파 진단기기 사용은 무면허의료행위인가? -대법원 2022. 12. 22. 선고 2016도21314 전원합의체 판결-)

  • Lee, Dongjin
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.1
    • /
    • pp.3-42
    • /
    • 2023
  • The Supreme Court en banc decision on December 12, 2022 (docket number 2016Do21314) ruled that the diagnosis of endometrial hyperplasia by an oriental medical doctor using a diagnostic ultrasound device was not an unlicensed medical practice for an oriental medical doctor, which shall be scrutinized by the article 27 (1) of the Korean Medical Service Act. This ruling did not determine that a specific medical practice, especially diagnosis, based on the radiology, which is a part of western medicine, was not an unlicensed medical practice for an oriental medical doctor. Rather, it intended to clarify that the prosecutor should specify and prove the way of diagnosis and he should not prosecute mere the use of a diagnostic ultrasound device itself. To that extent, the ruling is agreeable because, as the oriental medicine community has argued, there is no regulation prohibiting the use of certain devices. It is probable, however, that the way of diagnosis established in radiology, which is a part of western medicine, was actually used in the case. In that case, there is undeniably an unlicensed medical practice for an oriental medical doctor. While many of the cases where the demarcation between (western) medicine and oriental medicine have been problematized thus far have been experimental treatment in nature, the above practice of using ultrasound appears to be frequently done in many oriental clinics, and so it is necessary to cope with the possibility of a disguised unlicensed medical practice. Another problem is the prevention of unfair practice or the protection of medical consumers. In fact, many oriental medical clinics' practice appear to have a tendency of inducing medical consumers' misunderstanding that a diagnosis based on radiology, which is a part of western medicine, were provided. It is hard to respond to this problem with demarcation between (western) medicine and oriental medicine. A new regulation against unfair practice might be necessary to implement.

Usefulness of Ultrasound in Treatment of Patella Fracture (슬개골 골절 치료에서 초음파의 유용성)

  • Kim, Jung-Man;Nam, Ho-Jin;Ra, Ki-Hang;Park, Se-Wook
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.3 no.1
    • /
    • pp.26-31
    • /
    • 2010
  • Purpose: The purpose of this study is to evaluate the clinical usefulness of ultrasound in treatment of patella fracture. Material and Methods: Twenty cases of twenty patients with patella fracture radiographically from March, 2006 to September, 2009 were involved in this study, there were 8 males and 12 females, there were 13 right knees, 7 left knees, the average age was 43 years (range, 14~72 years). We decided the methods of treatment by using the ultrasound in conjunction with Drayer's test that examining the intactness of patella retinaculum. There were 10 transverse, 8 vertical and 2 comminuted fractures, we examined the patella retinaculum by using the ultrasound and performed Drayer's test. Results: In 12 cases of intact retinaculum, Drayer's test was negative and we allowed patients ambulation without surgical fixation especially. In 4 cases of completely ruptured retinaculum, Drayer's test was positive and we treated the patella fractures by the use of ORIF (open reduction and internal fixation) method, in 2 cases of partially ruptured retinaculum, Drayer's test was negative but displacement of fractures were more than 2 mm, we treated the patella fractures by the use of CRIF (closed reduction and internal fixation) method and obtained clinically satisfactory results. Conclusion: In conjunction with radiographs and Drayer's test, an ultrasound would be one of the useful diagnostic modality for determining treatment method of the patella fracture.

  • PDF

Diagnostic Correlation between Ultrasonography and CT Arthrography in Rotator Cuff Disease (회전근 개 질환에서 초음파 검사와 관절 조영 컴퓨터 단층 촬영의 진단적 가치 비교)

  • Park, Tae Soo;Yoon, Jong Pil;Kim, Hyung Sup;Jeong, Won-Ju
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.2
    • /
    • pp.53-59
    • /
    • 2013
  • Purpose: The aim of this study wasto evaluate the comparison of CT arthrography and ultrasonography, confirmed by the arthroscopic finding in patients with rotator cuff disease. Materials and Methods: We evaluated fifty seven patients with rotator cuff disease underwent CTA and arthroscopy, and twenty eight patients had taken ultrasonographyadditionally. The diagnostic value and prediction for tear size between CTA and ultrasonography were evaluated, as compared to arthroscopic findings. Results: CTA showed a sensitivity of 86.2% and a specificity of 100% in full thickness tear ofsupraspinatus, a sensitivity of 58.3% and a specificity of 87.8% in partial-thickness tear. CTA demonstrated good diagnostic value for full thickness tear, but there was relatively lower value for partial-thickness tear. Ultrasonography showed a sensitivity of 84.6% and a specificity of 86.7% for diagnosing in full thickness tear, a sensitivity of 84.6% and a specificity of 73.3% in partial-thickness tear. Ultrasonography provided good diagnostic value, but, there is lesser accurate result for prediction of tear size. Conclusion: CTA showedgood diagnostic tool of detection full-thickness tear of rotator cuff disease and predicting of tear size. Comparing with ultrasonography, CTA was inferior for detection of partial-thickness tear, but, provided better estimation for tear size.

  • PDF

Effect of a Deep Learning Framework-Based Computer-Aided Diagnosis System on the Diagnostic Performance of Radiologists in Differentiating between Malignant and Benign Masses on Breast Ultrasonography

  • Ji Soo Choi;Boo-Kyung Han;Eun Sook Ko;Jung Min Bae;Eun Young Ko;So Hee Song;Mi-ri Kwon;Jung Hee Shin;Soo Yeon Hahn
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.749-758
    • /
    • 2019
  • Objective: To investigate whether a computer-aided diagnosis (CAD) system based on a deep learning framework (deep learning-based CAD) improves the diagnostic performance of radiologists in differentiating between malignant and benign masses on breast ultrasound (US). Materials and Methods: B-mode US images were prospectively obtained for 253 breast masses (173 benign, 80 malignant) in 226 consecutive patients. Breast mass US findings were retrospectively analyzed by deep learning-based CAD and four radiologists. In predicting malignancy, the CAD results were dichotomized (possibly benign vs. possibly malignant). The radiologists independently assessed Breast Imaging Reporting and Data System final assessments for two datasets (US images alone or with CAD). For each dataset, the radiologists' final assessments were classified as positive (category 4a or higher) and negative (category 3 or lower). The diagnostic performances of the radiologists for the two datasets (US alone vs. US with CAD) were compared Results: When the CAD results were added to the US images, the radiologists showed significant improvement in specificity (range of all radiologists for US alone vs. US with CAD: 72.8-92.5% vs. 82.1-93.1%; p < 0.001), accuracy (77.9-88.9% vs. 86.2-90.9%; p = 0.038), and positive predictive value (PPV) (60.2-83.3% vs. 70.4-85.2%; p = 0.001). However, there were no significant changes in sensitivity (81.3-88.8% vs. 86.3-95.0%; p = 0.120) and negative predictive value (91.4-93.5% vs. 92.9-97.3%; p = 0.259). Conclusion: Deep learning-based CAD could improve radiologists' diagnostic performance by increasing their specificity, accuracy, and PPV in differentiating between malignant and benign masses on breast US.