• 제목/요약/키워드: Diagnostic tests

검색결과 816건 처리시간 0.028초

신생아 혈액 응고질환: 출혈 경향을 보이는 신생아에 대한 진단적 접근 (Neonatal Coagulation Disorder: Diagnostic Approaches for Bleeding Neonates)

  • 김천수
    • Neonatal Medicine
    • /
    • 제18권1호
    • /
    • pp.6-13
    • /
    • 2011
  • All newborn infants with clinically significant bleeding should be evaluated for a hemostatic deficit. Medical history should include the following data: familial bleeding disorders, maternal illness and medication, age of bleeding onset, and prophylactic administration of vitamin K. The first essential step for evaluating bleeding neonates is determining whether the baby is sick or well. The physician should also evaluate the extent of the bleeding, features of bleeding lesions, and other abnormal findings from the physical examination. Skeletal anomalies may provide diagnostic clues. Depending on the clinical features and results of screening tests, other tests including coagulation factors may be useful for determining the diagnosis. All laboratory results must be considered in the context of age-related reference values. The platelet function analyzer provides a promising alternative to bleeding time. Fibrin degradation products and D-dimers are used for screening and specially testing fibrinolytic activity, respectively. The Apt test may help to rule out factors derived from maternal blood. Radiologic imaging studies are important because asymptomatic intracranial hemorrhages are common in neonates.

대용량 수치발전기의 절연진단에 의한 절연상태평가 (Assessment of Insulation Condition for Hydro-generator)

  • 이광호;박종진;김기원;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1810-1812
    • /
    • 2002
  • This test was performed to assess the insulation deterioration condition of the stator winding of Chung-Ju hydrogenerator #4 and Dae-Cheong hydrogenerator #2 which had been in service after being constructed 1980. The insulation diagnostic tests include resistance polarization index(P.I.) AC current, dissipation factor(Tan ${\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to factory test measurements.

  • PDF

수력발전기의 절연보강 전${\cdot}$후 절연상태 비교평가 (Assessment of Insulation Condition between Diagnosis and Impregnation for Hydro-Generator)

  • 변일환;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1124-1126
    • /
    • 2004
  • The measurements were performed to assess the insulation deterioration condition of the stator winding of Dae-Cheong hydro-generator ${\sharp}2$ which had been in service after being constructed 1980. After repair of the stator winding insulation. we conducted insulation diagnostic tests which include resistance, polarization index(P. I). AC current, dissipation factor($Tan{\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to the previous records. On the basis of these test results. this paper tried to present the importance of insulation repair for the generator stator winding.

  • PDF

고압유도전동기의 절연상태 평가 (Evaluation of Insulation Condition for High Voltage Induction Motor)

  • 이광호;임재일;김기원;정진달;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.783-785
    • /
    • 2003
  • This test was performed to assess the insulation deterioration condition of the stator winding of 3.3kV class induction motors which have been in service for 15 years after being installed in 1988. The insulation diagnostic tests include resistance, polarization index(P.I). dissipation factor(${\Delta}tan{\delta}$) and maximum partial discharges(Qmax). The results of diagnostic tests were compared to the visual inspection in overhaul.

  • PDF

대용량 수차발전기의 절연진단과 절연보수 상관관계 평가 (Assessment of Insulation Condition between Diagnosis and Impregnation for Hydro-Generator)

  • 오봉근;정진달;이광호;김현일;곽희진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.39-41
    • /
    • 2004
  • The measurements were performed to assess the insulation deterioration condition of the stator winding of Dae-Cheong hydro-generator #2 which had been in service after being constructed 1980. After repair of the stator winding insulation, we conducted insulation diagnostic tests which include resistance, polarization index(P.I), AC current, dissipation factor($Tan\delta$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to the previous records. On the basis of these test results, this paper tried to present the importance of insulation repair for the generator stator winding.

  • PDF

광견병 진단시약 및 예방백신의 국제표준 (Standard Diagnostic Tests and Vaccines for Rabies)

  • 강영배;이재진
    • 대한수의사회지
    • /
    • 제30권3호
    • /
    • pp.162-171
    • /
    • 1994
  • 이 자료는, 국제수역사무국(Office de International Epizooties : O.I.E.)에서 발행한 Manual of Standards for Diagnostic Tests and Vaccines for List A and List B Diseases of Mammals, Birds and Bees(1992) (포유류, 조류, 꿀벌에 있어서의 A급 및 B급 질병에 대한 진단시약 및 예방백신에 대한 표준지침) 중에서 광견병(B8, Rabies)에 관한 내용(Chapter 22, 205-215)을 우리나라의 광견병 방역대책 수립과 생물학적 제제개발을 위한 참고자료로 활용하기 위하여 번역 소개한 것이다. 본래의 원저자는 프랑스의 Dr J. Blancou로서 프랑스 국립수의식품연구원(CNEVA) 산하의 광견병 및 야생동물 병리연구소(Laboratoire d'Etudes sul la Rage et de la Pathologie des Animaux Sauvages)에 책임자로 재직한 바 있으며, 1991년 이후 현재에는 국제수역사무국(O.I.E)의 사무총장(Director-general)직을 맡고 있다.

  • PDF

Modality-Specific Working Memory Systems Verified by Clinical Working Memory Tests

  • Park, Eun-Hee;Jon, Duk-In
    • Clinical Psychopharmacology and Neuroscience
    • /
    • 제16권4호
    • /
    • pp.489-493
    • /
    • 2018
  • Objective: This study was to identify whether working memory (WM) can be clearly subdivided according to auditory and visual modality. To do this, we administered the most recent and universal clinical WM measures in a mixed psychiatric sample. Methods: A total of 115 patients were diagnosed on the basis of DSM-IV diagnostic criteria and with MINI-Plus 5.0, a structured diagnostic interview. WM subtests of Korean version of Wechsler Adult Intelligence Scale-IV and Korean version of Wechsler Memory Scale-IV were administered to assess WM. Confirmatory factor analysis (CFA) was used to observe whether WM measures fit better to a one-factor or two-factor model. Results: CFA results demonstrated that a two factor model fits the data better than one-factor model as expected. Conclusion: Our study supports a modality model of WM, or the existence of modality-specific WM systems, and thus poses a clinical significance of assessing both auditory and visual WM tests.

Application of Laboratory Medicine in the Field of Oral Medicine

  • Moon-Jong Kim
    • Journal of Oral Medicine and Pain
    • /
    • 제47권4호
    • /
    • pp.167-173
    • /
    • 2022
  • Various diseases of the orofacial region that are treated in the field of oral medicine not only are associated with local factors but may also be affected by systemic factors. Knowledge about laboratory medicine is needed to identify the systemic factors that can influence these diseases. Therefore, oral medicine specialists should be able to use diagnostic tests of laboratory medicine and interpret the results in diagnosing and treating diseases in the field of oral medicine. The aim of this article is to examine the diagnostic tests used in laboratory medicine that might be applied to assess the systemic aspect of diseases in the field of oral medicine and to interpret the significance of the findings.

Comparative Assessment of Diagnostic Performances of Two Commercial Rapid Diagnostic Test Kits for Detection of Plasmodium spp. in Ugandan Patients with Malaria

  • Bahk, Young Yil;Park, Seo Hye;Lee, Woojoo;Jin, Kyoung;Ahn, Seong Kyu;Na, Byoung-Kuk;Kim, Tong-Soo
    • Parasites, Hosts and Diseases
    • /
    • 제56권5호
    • /
    • pp.447-452
    • /
    • 2018
  • Prompt diagnosis of malaria cases with rapid diagnostic tests (RDTs) has been widely adopted as an effective malaria diagnostic tool in many malaria endemic countries, primarily due to their easy operation, fast result output, and straightforward interpretation. However, there has been controversy about the diagnostic accuracy of RDTs. This study was conducted to evaluate the diagnostic performances of the 2 commercially available malaria RDT kits, RapiGEN Malaria Ag Pf/Pv (pLDH/pLDH) and Asan $EasyTest^{TM}$ Malaria Ag Pf/Pv (HRP-2/pLDH) for their abilities to detect Plasmodium species in blood samples collected from Ugandan patients with malaria. To evaluate the diagnostic performances of these 2 RDT kits, 229 blood samples were tested for malaria infection by microscopic examination and a species-specific nested polymerase chain reaction. The detection sensitivities for P. falciparum of Malaria Ag Pf/Pv (pLDH/pLDH) and Asan $EasyTest^{TM}$ Malaria Ag Pf/Pv (HRP-2/pLDH) were 87.83% and 89.57%, respectively. The specificities of the 2 RDTs were 100% for P. falciparum and mixed P. falciparum/P. vivax infections. These results suggest that the 2 RDT kits showed reasonable levels of diagnostic performances for detection of the malaria parasites from Ugandan patients. However, neither kit could effectively detect P. falciparum infections with low parasitaemia (<$500parasites/{\mu}l$).

Comparison the Diagnostic Value of Dilatation and Curettage Versus Endometrial Biopsy by Pipelle - a Clinical Trial

  • Sanam, Moradan;Majid, Mir Mohammad Khani
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권12호
    • /
    • pp.4971-4975
    • /
    • 2015
  • Background: Several methods have been presented for the evaluation of the endometrium in patients with abnormal uterine bleeding, which include minimal invasive and invasive approaches such as diagnostic curettage or endometrial biopsy by Pipelle. Many studies have been performed in order to compare two methods; diagnostic curettage and outpatient endometrial biopsy. This investigation compared sampling adequacy, endometrial histopathology, failure rates, duration and costs between diagnostic curettage in a hospital and endometrial biopsy. Materials and Methods: This single blind clinical trial was performed on 130 patients older than 35 years who was referred to Amir training hospital in 2013 for elective diagnostic curettage because of abnormal uterine bleeding. For all patients eligible for the study, an endometrial sample by Pipelle was taken without anesthesia or dilatation. Then under general anesthesia diagnostic curettage was performed by sharp curette. Sampling duration was calculated and both samples were sent to the same pathologist. The diagnostic values of two methods in the diagnosis of normal endometrium, endometrial hyperplasia and carcinoma were compared. The costs of these two methods were also compared. Data analysis was performed by SPSS (version 16.0) software. Chi-Square, Fisher, and Pearson tests were used and were considered statistically significant at P values less than 0.05. Results: Two methods were agreed upon 88% of sampling adequacy and 94% of pathological results. Specificity of 100% and sensitivity of 90% for detection of proliferative endometrium, secretory endometrium, simple hyperplasia without atypia and 100% for cancer were recorded. Pipelle diagnostic accuracy in comparison with curettage, have been reported over 97%, so the failure rate in this study was below 5%. Sensitivity of Pipelle for detection of atrophic endometrium was reported below 50%. Duration and cost was lower in Pipelle versus curettage. Conclusions: It is concluded that due to high agreement and cohesion coefficient between curettage and Pipelle on the issue of sampling adequacy, histopathology finding (except atrophic endometrium), low failure rate, duration of sampling and cost, Pipelle can be introduced as a suitable alternative of diagnostic curettage.