• Title/Summary/Keyword: Diagnostic system

Search Result 2,396, Processing Time 0.041 seconds

Prevalence of Voiding Dysfunction and Constipation in Children with Attention Deficit Hyperactivity Disorder (주의력결핍 과잉운동장애 소아에서 배뇨장애와 변비의 유병률)

  • Kim, Joon Young;Lee, Eun Seob;Bang, Ji Seok;Oh, Yeon Joung;Lee, Yong Ju;Sung, Tae-Jung;Lee, Kon-Hee;Lee, Jung Won
    • Childhood Kidney Diseases
    • /
    • v.18 no.2
    • /
    • pp.71-76
    • /
    • 2014
  • Purpose: Attention deficit hyperactivity disorder (ADHD) has been associated with impairments in frontal inhibitory function and the catecholaminergic system. ADHD is diagnosed in 3-5% of children. Children with ADHD seem develop various forms of urinary problems such as nocturnal enuresis, dysfunctional voiding, and diurnal incontinence. However, no data exist to confirm the presence of these problems in Korean children with ADHD. We investigated the clinical findings of voiding dysfunction in children with ADHD. Methods: Between October 2009 and March 2011, a total of 63 children (33 with ADHD, 30 with an upper respiratory infection, as a control group) were enrolled. ADHD was diagnosed using the diagnostic and statistical manual of mental disorders (DSM)-IV criteria. A comprehensive survey of voiding and defecation was administered. Results: The patient group included 28 boys and 5 girls; the control group comprised 20 boys and 10 girls. The mean age was $9.09{\pm}2.8$ years in the ADHD group and $8.58{\pm}3.1$ years in the control group. Children with ADHD had a statistically significantly higher incidence of urgency (P =0.017), urge incontinence (P =0.033), and constipation (P =0.045). There was no significant difference in the incidence of straining, intermittency, holding maneuvers, or nocturnal enuresis. Conclusion: Children with ADHD in Korea have significantly higher rates of urgency, urge incontinence, and constipation than those without ADHD.

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

Adoption and Efficacy of ISO 15189 in Medical Laboratories for Diagnostic and Research (메디컬시험기관에서 ISO 15189 도입의 필요성과 시행의 효용성)

  • Yang, Man-Gil;Lee, Won Ho;Jun, Jin Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.158-167
    • /
    • 2016
  • The requirements for medical laboratories ISO 15189 is examined in organization and a quality management system, stressing the importance of evidence, document control, and control of records and clinical material. Medical services are provided from the areas of resource management, and pre-examination, examination and post-examination processes. The main goal of ISO 15189 accreditation is to improve the quality of laboratory services provided for patients and clinical users not only through compliance with consensually developed and harmonized requirements but also by adopting the philosophy of continual improvement using the Plan-Do-Check-Act cycle. Laboratory quality should be evaluated and improved in all steps of the testing process as the state-of-the art indicates that the pre- and post-analytical phases are more vulnerable to errors than the intra-analytical phase. The Korea Laboratory Accreditation Scheme (KOLAS), a national accreditation body, provides medical laboratory accreditations for appropriate approaches to evaluating the competence of a medical laboratory in providing effective services to its customers and clinical users. Adoption of ISO 15189 in 2010s as a government policy has been delayed, and only 5 laboratories have been accredited to date in Korea. The medical laboratories should seek the adoption of ISO 15189 with a positive attitude for quality improvement and strengthening of international competitiveness.

Egg Antibody Farming and IgY Technology for Food and Biomedical Applications (식품과 생의학을 위한 계란 항체생산과 IgY 기술의 활용)

  • Sim, Jeong S.;Sunwoo, Hoon H.
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2003.07b
    • /
    • pp.37-54
    • /
    • 2003
  • It has been recognized that the hen. like its mammalian counterparts. provides young chicks with antibodies as protection against hostile invaders. This system facilitates the transfer of specific antibodies from serum to egg yolk. and provides a supply of antibodies called immunoglobulin Y(IgY) to the developing embryo and the hatched chick. The protection against pathogens that the relatively immuno-incompetent newly hatched chick has. is through transmission of antibodies from the mother via the egg. Egg yolk. therefore. can be loaded with a large amount of IgY against pathogens which can immobilize the existing or invading pathogens during the embryo development or in day-old chicks. Thus. the immunization of laying hens to various pathogens results in production of different antigen-specific IgY in eggs. Egg yolk contains 8~20 mg of immunoglobulins (IgY) per $m\ell$ or 136~340 mg per yolk suggesting that more than 30 g of IgY can be obtained from one immunized hen in a year. By immunizing laying hens with antigens and collecting IgY from egg yolk. low cost antibodies at less than $10 per g compared to more than $20.000 per g of mammalian IgG can be obtained. This IgY technology opens new potential market applications in medicine. public health veterinary medicine and food safety. A broader use of IgY technology could be applied as biological or diagnostic tool. nut-raceutical or functional food development. oral-supplementation for prophylaxis. and as pathogen-specific antimicrobial agents for infectious disease control. This paper has emphasized that when IgY-loaded chicken eggs are produced and consumed. the specific antibody binds. immobilizes and consequently reduces or inhibits the growth or colony forming abilities of microbial pathogens. This concept could serve as an alternative agent to replace the use of antibiotics. since today. more and more antibiotics are less effective in the treatment of infections. due to the emergence of drug-resistant bacteria.

  • PDF

Is $^{99m}Tc$-MDP Mammoscintigraphy Useful in Patients with Breast Mass Lesions? ($^{99m}Tc$-MDP 유방 스캔은 유방 종괴의 감별진단에 임상적인 유용성이 있는가?)

  • Park, Seok-Gun;Lee, Yeon-Hee;Rhyu, Jin-Woo;You, Sun-Mee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.151-160
    • /
    • 1998
  • Purpose: Piccolo et al. advocated the usefulness of $^{99m}Tc$-MDP breast scan in differential diagnosis of breast mass with high accuracy. But there are little or no follow-up studies about it as we know. We studied $^{99m}Tc$-MDP uptake pattern and lesion/background ratio in patients complaining palpable breast lesions to evaluate the clinical usefulness of $^{99m}Tc$-MDP scan. Materials and Methods: Total 34 patients were studied with physical examination, mammo-gram and $^{99m}Tc$-MDP scan prospectively. Anteroposterior and both lateral view of breast were obtained 5 minutes after iv injection of 740 MBq $^{99m}Tc$-MDP. Breast uptake pattern of $^{99m}Tc$-MDP was analyzed by a grade system: 0=no uptake, grade 1=bilateral diffuse uptake, grade 2=asymmetric faint uptake, grade 3=focal hot uptake. 20 cases were pathologically confirmed by excision biopsy or aspiration biopsy. 14 cases were normal in physical examination and mammogram. Results: Pathologic results showed 7 carcinomas, 6 benign solid tumors, and 7 fibrocystic changes. Grade 3 pattern of $^{99m}Tc$-MDP uptake was noted in 4/7 carcinomas, 3/6 benign solid tumors, and 1/7 fibrocystic changes. Grade 2 pattern was 217, 0/7, 3/7 respectively. The average L/B ratio was 1.66 in carcinomas, 1.68 in benign solid masses, 1.20 in fibrocystic diseases, 1.05 in normal patients. L/B ratio was higher in carcinoma and benign mass groups than in fibrocystic change and normal control groups(p=0.005). But there was no statistical difference between L/B ratio of malignant mass group and benign mass group. Conclusion: $^{99m}Tc$-MDP scan is not suitable to routine clinical use for breast mass diagnosis. It might be used in limited conditions when whole body bone scan is planned.

  • PDF

Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay (뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성)

  • Byun, Jae-Hu;Park, Myung-Hwan;Lee, Jin-Wan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF

A comparative Study of Changing Pattern of Cause of Death Analysis of Korean, Korean in Japan and Japanese (재일한국인의 생활문화의 이질화와 적응과정에 관한 보건학적 연구(제 1보 한국, 재일한국인, 일본의 사인구조분석)

  • 김정근;장창곡;임달오;김무채;이주열
    • Korea journal of population studies
    • /
    • v.15 no.2
    • /
    • pp.15-59
    • /
    • 1992
  • After world war II Japanese life expectancy has been improved remarkably, and reached the highest level in the world around late 1970's. The life expectancy of Korean has also shown tremendous improvement in recent years with about 20 year's gap from the Japanese. The reason of rapid improvement of life expectancy can be explained by changes in the structure of cause of death due to health system, living standard, social welfare, health behavior of individuals and so on. Korean in Japan is placed under different situations from both Korean in Korea and Japanese in these regards, and expected to show different picture of cause of death pattern. The objective of this study is the comparision of changing patterns of cause of death of three population groups, Korean in Japan, Korean in Korea and Japanese, and to investigate the reasons which effect to the structural difference of mortality cause with special emphasis on health ecological aspects. One of the major limitations of the Korean causes of death statistics is the under-registration which ranges about 10% of the total events, and inaccuracy of the exact cause of death. Some 20% of registered deaths were unable to classify by ICD. However, it is concluded that the Korean data are evaluated as sufficient to stand for over-viewing of trends of cause of death pattern. The evaluation is done by comparing data from registration and field survey over the same population sample. Population data of Korean in Japan differ between two sources of data; census and foreigner's registration. Correction is done by life table method under the assumption that age-specific mortality pattern would accord with that of the Japanese. The crude death rate was lowest among Korean in Japan, 5.7 deaths per 1,000 population in 1965. The crude death rates of Korean in Japan and Japanese are increasing recently influenced by age structure while Korean in Korea still shows decreasing tendency. The adjusted death rate is lowest among Japanese, followed by Korean in Japan, and Korean in Korea. The leading causes of death of Korean in Korea until 1960's was infectious diseases including pneumonia and tuberculosis. The causes of death structure changed gradually to accidents, neoplasm, hypertensive disease, cerebro-vascular disease in order. The main difference in cause of death between Korean and Japanese if high rate of liver diseases and diabetes for both Korean in Japan and Korea. A special feature of cause of death among Korean in Korea is remakably high rate of hypertensive disease, which is assumed to be caused by physicians tendency in choosing diagnostic categories. The low ischemic heart disease and high vasculo-cerebral disease are the distinctive characteristic of the three population groups compared to western countries. Specific causes of death were selected for detailed sex, age and ethnic group comparisons based on their high death rates. Cancer is the cause of death which showed most dramatical increase in all three population groups. In Korea 20.1% of all death were caused by cancer in 1990 compared with 10.5% in 1981. Cancer of the liver is the leading cause of cancer death among Korean in Japan for both sexes, followed by cancer of the lung and cancer of the stomach, while that of Korean in Korea is cancer of the stomach, followed by cancer of the liver and cancer of the lung for male. Causes of infant mortality were examined among the three population groups since 1980 on yearly bases. For both Japanese and Korean in Japan, leading cause of death ranks as conditions originating in the perinatal period, congenital anomalies, accidents and other violent causes. Trends since 1980 for these two population groups in the leading cause of infant mortality showed no changes. On the contrary, significant changes in leading cause of death structure in Korea were observed : the ranking of leading cause of death in 1981 were congenital asnomalies, pneumonia bronchitis, infectious disease, heart disease, conditions originating in the perinatal period, accident and other violent causes ; in 1990 the ranking shifted to congenital anomalies, accident, pneumonia bronchities, conditions originating in the perinatal period, infectious disease. The mortality rate by congenital anomalies in Korea continuously grew than any other causes. Larger increase ocurred during the 1990's

  • PDF

The Prognostic Indicies of Pneumocystis Carinii Pneumonia in Immunocompromised Patients other than Acquired Immune Deficiency Syndrome (비 AIDS 면역 결핍 환자들에서 발생한 주폐포자충 폐렴의 예후인자)

  • Park, Wann;Kim, Yoo-Kyum;Lee, Jin-Seong;Ahn, Jong-Jun;Hong, Sang-Bum;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.805-812
    • /
    • 1998
  • Background: Among the variety of opportunistic infections, pneumonia comprises the major morbidity in immunocompromised patients. Pneumocystis carnii pneumonia (PCP) and cytomegalovirus (CMV) pneumonia are common infectious illness of immunocompromised hosts. Although there are many reports regarding to the co-infection of PCP and CMV diagnosed by bronchoalveolar lavage (BAL) fluid examination, the effects of CMV co-infection on the outcome of PCP is still controversial. The purpose of this investigation is to evaluate the effects of CMV detected by BAL fluid examination on the clinical course of PCP in the immunocompromised patients other than human immunodeficiency virus infection. Method: Ten patients with PCP were enrolled and retrospective analysis of their medical records were done. HIV infected persons were excluded. The PCP was diagnosed by BAL fluid examination with Calcofluor-White staining. CMV was detected in BAL fluid by Shell-vial culture system. Chest radiographic findings were reviewed. We used Fisher's exact test and Mann-Whitney U test for statistical analysis of data. Results: The underlying disorders of patients were idiopathic pulmonary fibrosis (n=1), renal transplantation (n=4), necrotizing vasculitis (n=l), systemic lupus erythematosus (n=1), brain tumor (n=1), chronic myelogenous leukemia (n=1), unidentified (n=1). There were no difference in clinical course, APACHE III score, arterial blood gas analysis, white blood cell count, lymphocyte count, serum albumin concentration, chest radiographic findings and mortality between patients with PCP alone (n=4) and those with CMV co-infection (n=6). Univariate analysis regarding to the factors that associated with mortality of PCP were revealed that the application of mechanical ventilation (p=0.028), the level of APACHE III score (p=0.018) and serum albumin concentration (p=0.048) were related to the mortality of patients with PCP. Conclusion: The clinical course of PCP patients co-infected by CMV were not different from PCP only patients. Instead, accompanied respiratory failure, high APACHE III score and poor nutritional status were associated with poor outcome of PCP.

  • PDF

STUDY ON THE RELATIONSHIP BETWEEN ONTOGENY OF SEROTONIN SYSTEM AND PSYCHOPATHOLOGY IN CONDUCT DISORDER (행동장애에 있어서 Serotonin계의 개체발생적인 과정과 정신병리와의 상호관계에 관한 연구)

  • Shin, Sun-Woong;Shin, Min-Sup;Hwang, Jun-Won;Kim, Boong-Nyun;Cho, Soo-Churl
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.14 no.1
    • /
    • pp.112-122
    • /
    • 2003
  • Objectives:Considerable data indicate that diminished serotonergic activity is related to aggressive behavior. In order to understand the biological etiology in conduct disorder, we studied the relationships of plasma serotonin and 5-HIAA levels in conduct disorders to measures of aggression, violation of rules and oppositional defiant behavior. Methods:Subjects were selected from inpatients and outpatients department of the Division of Child and Adolescent Psychiatry of Seoul National University Hospital. 41 conduct disorders(18 childhoodonset type, 23 adolescent-onset type) and 23 normal controls were included in this study. For the assessment of aggression, rule violation and oppositional behavior, parents completed the rating scale for conduct disorder and oppositional behavior based on the DSM-IV diagnostic criteria. Plasma serotonin and 5-HIAA levels were determined by HPLC with electrochemical detection. Results:1) Plasma 5-HT and 5-HIAA levels were not significantly different among childhood-onset conduct disorder, adolescent-onset conduct disorder and normal control subjects. 2) No significant correlations were found between plasma 5-HT levels and aggression or rule violation. 3) Plasma 5-HT levels showed significant positive correlations with oppositional behavior both in childhood-onset conduct disorder and adolescent-onset conduct disorder. 4) Age-related changes were not found in plasma 5-HT and 5-HIAA levles. Conclusion:Our findings do not support the hypothesis that dysregulation of serotonergic function may be associated with aggresson. Instead, our data suggest that serotonergic function is more closely related with oppositional behavior than aggression.

  • PDF

Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography (소아 흉부촬영 시 나이와 체격에 따른 입사피부선량)

  • Shin, Gwi-Soon;Min, Ki-Yeul;Kim, Doo-Han;Lee, Kwang-Jae;Park, Ji-Hwan;Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • Exposure during childhood results in higher risk for certain detrimental cancers than exposure during adulthood. We measured entrance skin dose (ESD) under 7-year children undergoing chest imaging and compared the relationship between ESD and age, height, weight, chest thickness. Though it is important to measure chest thickness for setting up the exposure condition of chest examination, it is difficult to measure chest thickness of children. We set up exposure parameters according to age because chest thickness of children has correlation with age. In the exposure parameters, for chest A-P examination under 2 year-children, tube voltage (kVp) in hospital A was higher than that in hospital B while tube current (mAs) was higher in hospital B, thus the ESD values were about 1.7 times higher in hospital B. However, for chest P-A examination over 4 year-children, the tube voltage was 7 kVp higher in hospital B, the tube current were same in all two systems, and focus to image receptor distance (FID) in hospital B (180 cm) was longer than that in hospital A (130 cm), thus the ESD values were 1.4 times higher in hospital A. For same ages, the ESD values for chest A-P examinations were higher than those for chest P-A examinations. Comparing ESD according to age, ESD values were $154{\mu}Gy$, $194{\mu}Gy$ and $138{\mu}Gy$ for children under 1 year, 1 to under 4 years and 4 to under 7 years of age, respectively. These values were lower than reference level ($200{\mu}Gy$) recommended in JART (japan association of radiological technologists), however these were higher than reference values recommended by EC (european commission), NRPB (national radiological protection board) and NIFDS (national institute of food & drug safety evaluation). In conclusion, the values of ESD were affected by exposure parameters from radiographer's past experience more than x-ray system. ESD values for older children were not always higher than those for younger children. Therefore we need to establish our own DRLs (diagnostic reference levels) according to age of the children in order to optimize pediatric patient protection.