• Title/Summary/Keyword: Diagnostic rate

Search Result 1,220, Processing Time 0.025 seconds

Diagnostic approach of orthostatic dizziness/vertigo

  • Lee, Hyung;Kim, Hyun Ah
    • Annals of Clinical Neurophysiology
    • /
    • v.22 no.2
    • /
    • pp.75-81
    • /
    • 2020
  • This paper introduces new diagnostic criteria and differential diagnosis of orthostatic dizziness to help clinicians to diagnose hemodynamic orthostatic dizziness. Clinicians need to be able to discriminate hemodynamic orthostatic dizziness from other types of dizziness that are induced or aggravated when standing or walking. Measurements of the orthostatic blood pressure and heart rate are important when screening hemodynamic orthostatic dizziness. Detailed history-taking, a physical examination, and laboratory tests are essential for finding the cause of hemodynamic orthostatic dizziness. The differential diagnosis of hemodynamic orthostatic dizziness is crucial because it can be caused by various autonomic neuropathies.

Alternative accuracy for multiple ROC analysis

  • Hong, Chong Sun;Wu, Zhi Qiang
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.6
    • /
    • pp.1521-1530
    • /
    • 2014
  • The ROC analysis is considered for multiple class diagnosis. There exist many criteria to find optimal thresholds and measure the accuracy of diagnostic tests for k dimensional ROC analysis. In this paper, we proposed a diagnostic accuracy measure called the correct classification simple rate, which is defined as the summation of true rates for each classification distribution and expressed as a function of summation of sequential true rates for two consecutive distributions. This measure does not weight accuracy across categories by the category prevalence and is comparable across populations for multiple class diagnosis. It is found that this accuracy measure does not only have a relationship with Kolmogorov - Smirnov statistics, but also can be represented as a linear function of some optimal threshold criteria. With these facts, the suggested measure could be applied to test for comparing multiple distributions.

Cardio-Angiographic Sequence Coding Using Neural Network Adaptive Vector Quantization (신격회로망 적응 VQ를 이용한 심장 조영상 부호화)

  • 주창희;최종수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.4
    • /
    • pp.374-381
    • /
    • 1991
  • As a diagnostic image of hospitl, the utilization of digital image is steadily increasing. Image coding is indispensable for storing and compressing an enormous amount of diagnostic images economically and effectively. In this paper adaptive two stage vector quantization based on Kohonen's neural network for the compression of cardioangiography among typical angiography of radiographic image sequences is presented and the performance of the coding scheme is compare and gone over. In an attempt to exploit the known characteristics of changes in cardioangiography, relatively large blocks of image are quantized in the first stage and in the next stage the bloks subdivided by the threshold of quantization error are vector quantized employing the neural network of frequency sensitive competitive learning. The scheme is employed because the change produced in cardioangiography is due to such two types of motion as a heart itself and body motion, and a contrast dye material injected. Computer simulation shows that the good reproduction of images can be obtained at a bit rate of 0.78 bits/pixel.

  • PDF

Chest Wall Implantation of Lung Cancer after Percutaneous Fine Needle Aspiration - Report of one case - (경피적 폐생검술후 흉벽에 전이된 폐암;1례 보고)

  • 원태희
    • Journal of Chest Surgery
    • /
    • v.25 no.7
    • /
    • pp.707-710
    • /
    • 1992
  • Percutaneous needle aspiration has been widely used in the diagnosis of pulmonary lesions, because it is a fairly simple procedure with good diagnostic accuracy and low complication rate. Among its complications, the spread of malignant cells along the needle tract is rare but serious one. We report a case of chest wall implantation of lung cancer after the percutaneous fine needle aspiration biopsy. A 57-year-old man had undergone a right upper lobectomy for squamous cell carcinoma [T2N0M0] of the lung, 3 months after the operation, a growing mass, located far from the previous thoracotomy incision, developed on the right anterior chest wall where the diagnostic thin needle biopsy had been performed before the lobectomy. A wide excision of the chest wall mass was performed, and permanent histology showed squamous cell carcinoma as noted before.

  • PDF

Studies on Enzyme-linked Immunosorbent Assay(ELISA) for Detection of Antibody to Mycobacterium bovis in Serum and Milk (Enzyme-linked Immunosorbent Assay(ELISA)를 이용한 혈청 및 원유 중의 Mycobacterium bovis 항체 검출에 관한 연구)

  • 심항섭;국정희;박병옥;김성열;박유순
    • Korean Journal of Veterinary Service
    • /
    • v.20 no.2
    • /
    • pp.133-142
    • /
    • 1997
  • In order to supplement a diagnostic method for detection of infectious cattle to bovine tuberculosis, performed ELISA for detection of antibody to if bovis in serum and milk. The diagnostic efficacy of the established ELISA was compared with test of the tuberculin skin test for bovine tuberculosis. The positive corresponding rate of serum ELISA and tuberculin skin test showed 84.3%, milk ELISA and tuberculin skin test showed 75.0%, milk ELISA and serum ELISA showed 75.0% respectively. Comparison of the serum and milk to tuberculin antibody concentration in tuberculin positive cattle, the milk contained 1/100-1/150 concentration compared serum tuberculin concentration. The established ELISA was considered efficient for detection of antibodies to M bovis in serum and milk.

  • PDF

Sjögren's Syndrome: an Update on Diagnostic, Clinical, and Basic Aspects for Oral Medicine Specialists

  • Lee, Kyung-Eun
    • Journal of Oral Medicine and Pain
    • /
    • v.43 no.4
    • /
    • pp.99-111
    • /
    • 2018
  • $Sj{\ddot{o}}gren^{\prime}s$ syndrome (SjS) is a common autoimmune disorder characterized by lymphocytic infiltration in the salivary and lacrimal glands, resulting in severe dry mouth or eyes. As a result, most of SjS patients suffer from oral dryness and can visit the department of oral medicine with or without diagnosis of SjS. Therefore, oral medicine specialists should know clues, which may indicate the diagnosis of SjS from the clinical and laboratory investigations. By the recent SjS criteria, SjS can be diagnosed by focus score, ocular staining, Schirmer's test, unstimulated whole saliva flow rate, and anti-SSA/Ro antibodies. The aim of this article is to review the diagnostic criteria, clinical investigation, and basic aspect related to SjS and to make oral medicine specialists play an important role in the detection of emerging SjS.

Design and Development of a Public Waste Battery Diagnostic Device

  • Kim, Sang-Bum;Lee, Sang-Hyun
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.281-286
    • /
    • 2022
  • In this study, design of an intuitive internal resistance diagnostic device is to diagnose the residual capacity and aging of the battery regardless of the model and the internal protocol of the waste battery through the method of measuring the internal resistance of a waste battery. In this paper, charging and discharging were continuously performed with 2A charging and 5A discharging in order to secure data on impedance changes that may occur in the charging and discharging process of various methods. As a result of the final experiment, it was confirmed that the impedance change occurred during charging and discharging, and the amount of change increased as the charging/discharging C-rate increased. In addition, it was confirmed that the waste battery aged or abnormal cell had a large change in the impedance value.

Development Cut-off Value for Yin-deficiency Questionnaire and Diagnostic Ability of Yin-deficiency in Xerostomia (구강건조증 환자에서 음허 측정 설문지 절단점 개발 및 진단능 평가)

  • Jang, Seung-Won;Kim, Jin-Sung
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.4
    • /
    • pp.483-497
    • /
    • 2014
  • Objectives: The aims of study were developing cut-off value of Yin-deficiency questionnaire (YDQ) for diagnosis of Yin-deficiency (YD) and compare diagnostic ability between YDQ and Yin-deficiency scale score (YDS) in xerostomia patients. Methods: We recruited 58 xerostomia patients. They were diagnosed YD or non-YD by 3 Korean medicine doctors (KMD). We assessed YD using YDQ and YDS. We evaluated xerostomia using VAS, Dry Mouth Symptom Questionnaire (DMSQ), Salivary Flow Rate (SFR), oral moisture on buccal mucosa and tongue surface (OMB and OMT). We surveyed tongue coatings using Winkel Tongue Coating Index (WTCI). Results: We diagnosed 23 patients YD and 35 patients non-YD. There were no significant differences of age, sex and body mass index between the YD and non-YD groups. Using receiver operating characteristic curve analysis, the optimal cut-off value of YDQ was defined as 304. Sensitivity, specificity and Youden index of YDQ were 86.96%, 71.43% and 1.5839 respectively. Using Cohen's coefficient of agreement, we found that degree of agreement between KMD and YDQ diagnosis was moderate (${\kappa}$=0.524, p<0.001). Using Pearson's correlation analysis, we found concurrent validity of YDQ and YDS were significant correlated. Using area under curve value, we found diagnostic ability between YDQ and YDS were not significantly different (p=0.505), but there were more strong correlations between DMSQ-symptoms and YDQ (r=0.731, p<0.001) than correlations between DMSQ-symptoms and YDS (r=0.418, p<0.01). Conclusions: The cut-off value of YDQ can diagnose YD in xerostomia and diagnostic ability of YDQ in xerostomia is better than YDS.

Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques

  • Campello, Andrea Fagundes;Goncalves, Lucio Souza;Guedes, Fabio Ribeiro;Marques, Fabio Vidal
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • Purpose: The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). Materials and Methods: An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using #1/2, #2, #4, and #6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chisquare test. Results: The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions(P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). Conclusion: CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy.

The Role of Endoscopic Retrograde Cholangiopancreatography (ERCP) in the Treatment of Traumatic Pancreas Injury (외상성 췌장 손상에서 내시경적 담췌관 조영술의 역할)

  • Jeong, Min-Young;Kim, Young-Hwan;Kyoung, Kyu-Hyouck;Lee, Sung-Koo;Hong, Suk-Kyung
    • Journal of Trauma and Injury
    • /
    • v.24 no.2
    • /
    • pp.136-142
    • /
    • 2011
  • Purpose: Blunt pancreatic injury has a high mortality rate, especially if adequate management is delayed. Although many guidelines exist for diagnosis and treatment, there is no consensus to date. Therefore, we analyzed the role of endoscopic retrograde cholangiopancreatography (ERCP) as a diagnostic and therapeutic tool for the treatment of traumatic pancreatic injury. Methods: We retrospectively reviewed the electronic medical records (EMR) database at Asan Medical Center (Seoul, South Korea) to identify all patients diagnosed with trauma to the pancreas between June 2003 and December 2010. Clinical and operative findings, CT (computed tomography) images, and ERCP findings were assessed. Results: A total of 40 patients were evaluated in this study. Of these, 14 patients underwent diagnostic ERCP, and 26 did not. Of the 14 patients who underwent diagnostic ERCP, 5 were found to have normal pancreatic ducts, thereby preventing a needless laparotomy in these patients. Of the patients diagnosed with ductal injury, four were treated with endoscopic intervention, and four underwent an exploratory laparotomy. The remaining patient was treated with radiologic intervention (percutaneous drainage) to manage pancreatic pseudocyst formation. Conclusion: Our findings suggest that ERCP is a beneficial diagnostic and therapeutic modality for the treatment of traumatic pancreatic injury.