• 제목/요약/키워드: Diagnostic errors

검색결과 148건 처리시간 0.027초

마그네토스트릭션 효과를 이용한 발전기축의 비접촉 이상 진단 기법 (Non-contacting Diagnostic Techniques for Generator Shafts Using Magnetostrictive Effects)

  • 김윤영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.109-112
    • /
    • 2001
  • The specific goal of this research is to develop a non-contact measurement technique of stress waves propagating in a rotating shaft. This technique will enable on-line damage detection in shafts in power-generating systems. To minimize measurement errors due to shaft rotation, we have employed magnetostrictive sensors. The sensors are not only cost-effective but also insensitive to liftoff or fill factors. Several experimental results showed the effectiveness of the present technique. The damage location in a rotating shaft was accurately predicted by the wave signal measured by the present approach.

  • PDF

In-Situ Diagnosis of Vapor-Compressed Chiller Performance for Energy Saving

  • Shin Younggy;Kim Youngil;Moon Guee-Won;Choi Seok-Weon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1670-1681
    • /
    • 2005
  • In-situ diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the in-situ diagnosis is to predict the performance of a target chiller. Many models based on thermodynamics have been proposed for the purpose. However, they have to be modified from chiller to chiller and require profound knowledge of thermodynamics and heat transfer. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). The effect of sample data distribution on training the ANFIS is investigated. It is found that the data sampling over 10 days during summer results in a reliable ANFIS whose performance prediction error is within measurement errors. The reliable ANFIS makes it possible to prepare an energy audit and suggest an energy saving plan based on the diagnosed chilled water supply system.

균열이 있는 보의 모델링 및 동적 해석에 관한 연구 (A study on the Modeling and Dynamic Analysis of Cracked Beam Structures)

  • 홍성욱;김만달;이종원
    • 한국정밀공학회지
    • /
    • 제20권6호
    • /
    • pp.197-204
    • /
    • 2003
  • This paper presents an efficient modeling and dynamic analysis method for open cracked beam structures. An equivalent bending spring model is introduced to represent the structural weakening effect in the presence of cracks. The proposed method adopts the exact dynamic element method (EDEM) to avoid the inconvenience and numerical errors in association with re-meshing the structural model with the crack position changed. The proposed modeling method is validated through a series of simulation and experiments. First, the proposed method is rigorously compared with a commercial finite element code. Then, two kinds of experiments are performed to validate the proposed modeling method. Finally, a diagnostic scheme fur open cracked beam structures is proposed and demonstrated through a numerical example.

Quantitative Evaluation of Hepatic Steatosis Using Advanced Imaging Techniques: Focusing on New Quantitative Ultrasound Techniques

  • Junghoan Park;Jeong Min Lee;Gunwoo Lee;Sun Kyung Jeon;Ijin Joo
    • Korean Journal of Radiology
    • /
    • 제23권1호
    • /
    • pp.13-29
    • /
    • 2022
  • Nonalcoholic fatty liver disease, characterized by excessive accumulation of fat in the liver, is the most common chronic liver disease worldwide. The current standard for the detection of hepatic steatosis is liver biopsy; however, it is limited by invasiveness and sampling errors. Accordingly, MR spectroscopy and proton density fat fraction obtained with MRI have been accepted as non-invasive modalities for quantifying hepatic steatosis. Recently, various quantitative ultrasonography techniques have been developed and validated for the quantification of hepatic steatosis. These techniques measure various acoustic parameters, including attenuation coefficient, backscatter coefficient and speckle statistics, speed of sound, and shear wave elastography metrics. In this article, we introduce several representative quantitative ultrasonography techniques and their diagnostic value for the detection of hepatic steatosis.

병리추가조직검사 정보전달을 위한 업무프로세스 연구 (Study Focused on Task Process regarding Effective Information Transfer of Ancillary Tests in Diagnostic Pathology)

  • 고재남;박윤익;정진경;안상호;김재호;신화정;현지숙;김경호
    • 한국의료질향상학회지
    • /
    • 제22권2호
    • /
    • pp.95-108
    • /
    • 2016
  • Purpose: Ancillary tests such as immunohistochemistry or molecular testing for pathologic diagnosis are performed using ready-made tissue blocks for a histological examination. Various methods and processes during ancillary testing cause some of issues, particularly in the time required and the results reporting scheme. Methods: To solve these issues, we constructed real-time management software. When a pathologist or a clinician had ancillary tests examined using this software by selecting the codes of the needed ancillary tests on site and the system assigned the tests to each laboratory. Then, pathology technologists checked the referred tests and performed the examination. In clinical departments, serial number of each ancillary test can be matched the original pathologic ID. In the department of pathology, numbers of tissue blocks that needed additional tests could be indicated and detected using one-click detection system when a clinician referred the test. Results: Using this system resulted in simplifying the referral procedures from nine-steps to three-steps in each clinical department and from seven-steps to two-steps in department of pathology. Errors that happened on the paper-based request system were also reduced. Furthermore, the time required was saved by seven hours in pathologic laboratory on average. Mean durations from requesting to reporting of the ancillary test was reduced by three days for specimens of health promotion center. Conclusion: Construction of an effective information transfer system may be helpful for shortening the time required, reducing errors, and checking processing information of the tests in real time.

항체가 건조상태로 고정된 면역진단키트의 안정화와 Shelf-Life 결정 (Stabilization of Dry Immuno-Diagnostic Kit with Immobilized Antibody and Determination of Its Shelf-Life)

  • 이창우;조정환;육순학;권오협;박영남;박세환
    • KSBB Journal
    • /
    • 제13권5호
    • /
    • pp.502-510
    • /
    • 1998
  • Stabilization of antibody, which is specific to Salmonella typhimurium antigens, present in dry states on membranes was accomplished, and its shelf-life, i.e., duration for maintaining minimum 90% of the initial activity, under optimal conditions was determined. To prepare two major components of an immuno-strip, the antibody was not only immobilized on nitrocellulose membrane surfaces but also placed within the pores of glass fiber membrane after conjugating it with old colloids as signal generator. Among potential stabilizers of the immuno-components, a disaccharide, trehalose, showed a significant protection effect of immunoglobulin structure from thermal energy. Optimal concentrations of trehalose for the respective component were significantly different (8-fold higher for the antibody-gold conjugate than for the immobilized antibody), which probably resulted from distinct densities and configurations of antibody present on the membranes. An additional requirement for the gold conjugate was freeze-drying of this substance such that the conjugate can be readily resolubilized upon contact with aqueous medium. By using the components prepared under optimal conditions, immuno-strips were constructed and exposed to thermal energy. Signals with less than 10% decrease in the intensity were maintained for approximately 21 days at 60$^{\circ}C$. Compared to previous reports, this result represented a 2-year shelf-life at room temperature. it was, however, two times longer if determined from thermal acceleration tests based on the theory of inactivation rate of protein. Such discrepancy between the two estimates could be mainly attributed to errors in accurately controlling temperatures and also to changes in the physical properties of membranes due to a high thermal energy.

  • PDF

암환자 700예의 진단 및 치료 CT 이용율과 CT 확대장치 (The Availability of Diagnostic and Treatment Planning Computer in 700 Cancer Patients and Magnification Devices for CT)

  • 이귀원;박주선;한용문;윤세철;신경섭
    • 대한방사선치료학회지
    • /
    • 제2권1호
    • /
    • pp.81-85
    • /
    • 1987
  • It has been evident since 1972 that computed tomography(CT) can play an important role in treatment and managment of the cancer patients as four steps; diagnosis, satging Treatment and follow-up. In this paper, we intended to investigate the availability of CT scan and treatment planning computer in 700 cancer patients who have undergone radiation therapy at the division of radiation therapy, Kangnam St. Mary's Hospital, Catholic Medical College between Mar. 1983 and Dec. 1985. The result were as follow; 1. Of 700 irradiated cancer patients, 342 patients ($48.9\%$) were performed CT scan prior to radiation therapy. 2. The distribution of lesions in 342 patients having CT scans was like this; CNS (83 of 104 patients, $79.8\%$), abdomen (44 of 76 patients, $57.9\%$), pelvis (100 of 188 patients, $53.2\%$) etc. in order. 3. The treatment planning computer were used in 280 cancer patients ($40\%$). 4. Of the 280 cancer patients using treatment planning computer, 167 patients ($59.6\%$) applied diagnostic CT scan and remaining 113 patients ($40.4\%$) were made body contour to be used for radiation therapy planning by the treatment planning computer. Authors also made some magnification devices used for small multiformat CT images to magnify into life size, consisting of overhead projector (3M) I.V. stand and mirror. These enabled us to make less errors in tracing the small-sized CT images during input of the anatomical data into the treatment planning computer.

  • PDF

피부전기저항측정기(ABR-2000)의 맥진기(3D-MAC) 및 한방진단시스템(DSOM)과의 상관성 연구 (Study for Correlation of 3D-MAC and DSOM with ABR-2000)

  • 송정오;김민애;이인선
    • 대한한방부인과학회지
    • /
    • 제31권1호
    • /
    • pp.57-83
    • /
    • 2018
  • Purpose: This research has been carried out to find out correlation between test results of ABR-2000 and other diagnostic equipments to enhance significance of accurate diagnosis and clinical usage of ABR-2000. Methods: Duration of the 31 months from December 2012 to June 2015, records of 564 outpatients at gynecology department have been selected. The 564 patients were tested, using all 3 different test equipments of ABR-2000, DSOM, and 3D Blood Pressure Pulse Analyzer (3D-MAC) without test errors or mis-recordings. Correlation between 3D Blood pressure Pulse Analyzer, DSOM and ABR-2000 were analyzed by frequency & ratio factor of statistic data records of patients groups devided by 8 different disease symptom and by comparison of the groups in the form of Regulation and Graph presented on ABR-2000 equipment. Results: 1. The indicator L in all 1, 2, and 3 quadrant in the graph means the activity and reactivity of the upper body biodynamics detection rate is low and which result is very common symptom among gynecological patients. 2. The portion of patients with hypermenorrhea, endometritis, and menstrual pain symptom among the indicator L group in the reactivity 1-3 quadrantin is significantly high. 3. When 3D Mac analyzer indicates H, diastole decreases while systole increases and tachycardia increases then the blood circulation is expected to increase. In case of indication L, diastole increases and systole decreases then, the blood circulation is expected to decrease.

Clinical Effects of Korean Red Ginseng on Attention Deficit Hyperactivity Disorder in Children: An Observational Study

  • Lee, Suk-Hwa;Park, Woo-Sung;Lim, Myung-Ho
    • Journal of Ginseng Research
    • /
    • 제35권2호
    • /
    • pp.226-234
    • /
    • 2011
  • We investigated the clinical effects of Korean red ginseng on attention deficit hyperactivity disorder (ADHD) in children. Eighteen subjects aged between 6 and 14 diagnosed with ADHD based on the Diagnostic and Statistical Manual of Mental Disorders, fourth edition diagnosis criteria were enrolled. Korean red ginseng (Panax ginseng) at 1,000 mg b.i.d. was administered to the subjects for 8 weeks. Eighteen children completed the questionnaire and clinical assessment by visiting the hospital at baseline, then in the first, fourth and eighth weeks. Clinical assessments were performed by using the ADHD Diagnostic System (ADS, a computerized attention assessment program), the abbreviated Conners' rating scale in addition to psychiatric interviews. After 8 weeks, significant differences were found in the omisssion errors of ADS ($78.56{\pm}43.33$ at baseline, $55.17{\pm}21.44$ at 8 weeks, p<0.023), Conners ADHD Rating Scale ($13.78{\pm}6.32$ at baseline, $9.50{\pm}4.80$ at 8 weeks, p<0.042) and Spielberger State Anxiety Scale ($30.94{\pm}6.25$ at baseline, $28.83{\pm}6.23$ at 8 weeks, p<0.024). In the Korean Personality Inventory for Children, a significant reduction of score was found in the physical development scale ($56.44{\pm}9.63$ at baseline, $50.94{\pm}8.91$ at 8 weeks, p<0.017) and social dysfunction scale ($56.33{\pm}6.82$ at baseline, $51.94{\pm}7.13$ at 8 weeks, p<0.025). These results suggest that Korean red ginseng may be effective in improving inattentiveness in ADHD children, but it remains uncertain if it improves the general severity of ADHD, depression, anxiety personality and behavioral changes.

수압 측정에 기반하는 요류검사의 정확도 검증 (Accuracy Validation of Urinary Flowmetry Technique Based on Pressure Measurement)

  • 최성수;이인광;김군진;강승범;박경순;이태수;차은종;김경아
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.198-204
    • /
    • 2008
  • Uroflowmetry is a non-invasive clinical test useful for screening benign prostatic hyperplasia(BPH) common in the aged men. The current standard way to obtain the urinary flow rate is to continuously acquire the urine weight signal proportional to volume over time. The present study proposed an alternative technique measuring pressure to overcome noise problems present in the standard weight measuring technique. Experiments were performed to simultaneously acquire both weight and pressure changes during urination of 9 normal men. Noise components were separated from volume signals converted from both weight and pressure signals based on the polynomial signal model. Signal-to-noise ratio was defined as the ratio of the energies between signal and noise components of the measured volume changes, which was 8.5 times larger in the pressure measuring technique, implying that cleaner signal could be obtained, more immune to noisy environments. When four important diagnostic parameters were estimated, excellent correlation coefficients higher than 0.99 were resulted with mean relative errors less than 5%. Therefore, the present pressure measurement seemed valid as an alternative technique for uroflowmetry.