• 제목/요약/키워드: Diagnostic X-ray

검색결과 600건 처리시간 0.028초

객혈 환자에서 기관지경술이나 기관지동맥색전술 시행 전의 다중절편 전산화 단층촬영의 유용성 (Usefulness of Multi-Detector Computed Tomography before Bronchoscopy and/or Bronchial Arterial Embolization for Hemoptysis)

  • 이신재;노지영;유승민;김만득;이지현;김은경;조영아;이상민
    • Tuberculosis and Respiratory Diseases
    • /
    • 제68권2호
    • /
    • pp.80-86
    • /
    • 2010
  • Background: Recently, many institutions have acquired multi-detector computed tomography (MDCT) systems. This made it easier and more convenient to use MDCT as a initial diagnostic modality for hemoptysis. The purpose of this study was to evaluate the usefulness of MDCT before bronchoscopy and/or bronchial arterial embolization (BAE) for hemoptysis. Methods: We studied a total of 125 patients with hemoptysis who underwent, between 2006 and 2008, MDCT in a routine protocol before bronchoscopy and/or BAE. One hundred two patients underwent bronchoscopy and 29 patients underwent BAE. We compared the usefulness of MDCT and bronchoscopy for detecting the bleeding site and identifying the cause. We also evaluated our ability, using MDCT, to detect instances where the bronchial artery caused hemoptysis. Results: The rate of detection of a bleeding site was 75.5% on MDCT and 50.9% on bronchoscopy. MDCT and bronchoscopy detected the bleeding site in agreement in 62.7% of patients. MDCT alone found the bleeding site in 27.5% of cases. MDCT identified the cause of hemoptysis in 77.5% and bronchoscopy in 11.8%. In 29 patients who underwent BAE, we detected a total of 37 hypertrophied bronchial arteries that were causing hemoptysis. Of 37 bronchial arteries, 23 (62.2%) were depicted on MDCT. Conclusion: MDCT is superior to bronchoscopy for detecting the bleeding site and identifying the cause of hemoptysis. MDCT can also predict the side of affected bronchial artery with depiction of hypertrophied bronchial artery and localizing the bleeding site. Doing MDCT before bronchoscopy and BAE can provide a guideline for the next step.

Digital Radiography(DR)에서 검출기의 X선 조건에 따른 흡수선량 및 영상화질 변화에 관한 연구 (Study on the Change of Absorbed Dose and Image Quality according to X-ray Condition of Detector in Digital Radiography(DR))

  • 황준호;정재호;김현수;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제17권9호
    • /
    • pp.99-106
    • /
    • 2017
  • 본 연구는 진단용 검출기가 결함이 발생하는 경우 환자의 방사선 피폭과 영상의 화질에 영향을 줄 수 있다는 점에 착안하여 실험을 진행하였고 선량분석을 통해 검출기 성능을 신호 대 잡음비와 대조도 대 잡음비로 평가하였다. 선량계, 조직등가팬텀을 이용해 흡수선량과 신호 대 잡음비, 대조도 대 잡음비를 측정하였다. 실험방법은 팬텀 후면에 부착하여 나온 선량 값과 검출기 뒤에 부착한 선량 값이 일치하는지를 비교하였고 두개부 흉부 복부의 조건을 각각 75 kVp 25 mAs, 110 kVp에 8 mAs, 80 kVp에 20mAs로 설정하고 검사하였다. 그 결과 검출기의 뒤쪽에 부착한 선량값은 0.004 mGy, 0.006 mGy, 0.003 mGy로 나타났고, 팬텀 후면은 0.006 mGy, 0.016 mGy, 0.017 mGy로 차이가 있었다. 두 값을 일치시키기 위해서 조건이 증가하였고 신호 대 잡음비와 대조도 대 잡음비는 88.32, 88.10, 4.09, 1.63, 87.94, 79.97에서 93.87, 93.75, 4.91, 4.03, 92.02, 84.92로 증가하였다. 본 연구를 통해 검출기가 노후화 되는 경우 기기의 수명단축과 환자의 선량증가의 원인이 되었으며 또한 영상화질의 개선효과도 미비하다는 것을 알 수 있었다.

치료방사선 조사가 잡종 백색마우스의 대장에 미치는 병리조직학적 영향 (The Effect of Total Dose of Radiation on Normal Colon of Hybrid Mice)

  • 조길호;김명세
    • Radiation Oncology Journal
    • /
    • 제4권2호
    • /
    • pp.99-105
    • /
    • 1986
  • 암의 방사선 치료는 단독, 혹은 수술이나 화학요법과의 병합치료를 통하여 좋은 생존율을 보여주고 있으나 정상 조직의 손상으로 인한 후유증은 아직도 해결되지 못하고 있는 문제중의 하나이다. 그러므로 정상조직의 손상에 대한 연구는 암 조직의 방사선에 대한 연구와 함께 필수적이며, 근래에 계속되고는 있으나 실제 임상에서 사용되고 있는 방법과 같은 분할조사에 대한 계통적인 연구는 매우 드물다. 이에 저자는 60마리의 백색 마우스를 사용하여 $2\times3cm$의 조사야로 고식적인 방법으로 분할 조사한 후 전 조사량에 따른 병리조직학적인 변화를 분석하고 잠혈반응 검사와의 상관관계를 규명하여, 직장에 심한 후유증이 오지 많을 수 있는 가능한 최대 내 선량을 추정하여 임상치료에 이용할 수 있는 기본 자료로 삼고자 하였으며 그 결과는 다음과 같다. 점막 및 점막하 부종은 1,000 rad군에서부터 관찰되었다. 소혈관 울혈은 2,000 rad군에서 현저하였고 염증세포의 침윤은 3,000 rad군에서 현저하였다. 점막의 탈락은 3,000 rad군에서부터 관찰되기 시작하였다. 잠혈반응은 점막탈락, 혹은 괴양의 정확한 척도로 삼기에는 부적당하였으나 총 조사량의 증가와 함께 잠혈반응의 양성도도 증가하는 추세를 보여 간접적인 지표로 삼을 수는 있으리라고 생각되었다. 소낭선세포의 분열상이 5,000 rad군에서도 관찰되는 것으로 미루어 5,000 rad의 조사에서도 재생능력이 남이 있음을 시사하였다.

  • PDF

Generator 컬럼용 68GeO2 합성 및 68Ga3+의 거동에 관한 연구 (Study on Synthesis of 68GeO2 and Behavior of 68Ga3+ for Generator Column)

  • 김건균;이준영;김상욱;허민구;양승대;박정훈
    • 방사선산업학회지
    • /
    • 제10권4호
    • /
    • pp.189-192
    • /
    • 2016
  • $^{68}Ga$ has emerged as a promising candidate for non-invasive diagnostic imaging within Positron Emission Tomography (PET) because of its advantageous radiochemical characteristics ($t_{1/2}=68min$, ${\beta}^+$ yield ~89%). $^{68}Ga$ forms a stable chelation with various ligands and it is possible to be quickly and easily study using a $^{68}Ge/^{68}Ga$ generator. Commercial $^{68}Ge/^{68}Ga$ generators are chromatographic system using the inorganic materials such as alumina and tin dioxide which are employed as column matrixes for $^{68}Ge$. In this study, we tried out to make $^{68}Ge/^{68}Ga$ generator system with the $^{68}GeO_2$ microstructures for column matrix. $^{68}Ge$ tends to have stable bond with oxide as $^{68}GeO_2$ microstructures. The $^{68}GeO_2$ has been synthesized by hydrolysis of $GeCl_4$ (sol-gel method) and characterized by X-ray diffraction and scanning electron microscope for geometrical analysis. The stability of $GeO_2$ was tested using eluents with diverse solvents(water, ethanol and 0.1 N HCl). The radioactivity of $^{68}Ga^{3+}$ in eluate through $GeO_2$ was measured to prove a function as column material for a generator.

LDH 나노입자 기반의 바이오 이미징 소재 (Layered Double Hydroxide Nanoparticles for Bio-Imaging Applications)

  • 김문희;하성진;이동기;박대환
    • Korean Chemical Engineering Research
    • /
    • 제57권4호
    • /
    • pp.445-454
    • /
    • 2019
  • Layered double hydroxides (LDHs) 나노입자는 특유의 층상형 결정구조에서 기인된 물리화학적 물성 및 생체친화성을 바탕으로 나노-바이오 분야에서 주목을 받고 있다. 바이오 이미징은 질병의 진단과 치료(테라노스틱스, theranostics=therapy+diagnosis)에 다양하게 활용될 수 있는 핵심적인 분야로 차세대 맞춤의학으로의 새로운 패러다임 실현을 위해서 보다 정확하고 빠른 진단기술이 절실히 요구되고 있다. 이를 실현하기 위한 대안으로 나노기술이 접목된 고감도 분자영상 관련 연구들이 활발히 진행되고 있다. 본 총설에서는 LDH 나노입자를 기반으로 하는 바이오 이미징 시스템의 개발동향에 관하여 소개하고 바이오 이미징에 적합한 나노소재의 구조 및 합성 방법에 대하여 설명하였다. 또한 임상 의학에서 현재 많이 사용되고 있는 형광을 이용한 광학영상, 자기공명영상(MRI), 핵의학영상(PET), 컴퓨터 단층 촬영(CT) 등 다양한 분야에서 어떻게 LDH 나노입자를 이용하여 나노 프로브 개발을 할 수 있는지 연구사례를 기술하면서 나노기술과 첨단영상기술이 융합된 획기적인 고감도 나노 바이오 이미징 시스템 개발 및 그 잠재력에 대하여 전망해 보았다.

Utility of Computed Tomography in a Differential Diagnosis for the Patients with an Initial Diagnosis of Chronic Obstructive Pulmonary Disease Exacerbation

  • Park, Hyung Jun;Kim, Soo Han;Kim, Ho-Cheol;Lee, Bo Young;Lee, Sei Won;Lee, Jae Seung;Lee, Sang-Do;Seo, Joon Beom;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • 제82권3호
    • /
    • pp.234-241
    • /
    • 2019
  • Background: The utility of computed tomography (CT) in the differential diagnosis of patients with chronic obstructive pulmonary disease (COPD) exacerbation remains uncertain. However, due to the low cost associated with CT scan along with the impact of Koreas' health insurance system, there has been a rise in the number of CT scans in the patients with initial diagnosis of COPD exacerbations. Therefore, the utility of CT in the differential diagnosis was investigated to determine whether performing CT scans affect the clinical outcomes of the patients with an initial diagnosis of COPD exacerbation. Methods: This study involved 202 COPD patients hospitalized with an initial diagnosis of COPD exacerbation. We evaluated the change in diagnosis or treatment after performing a CT scan, and compared the clinical outcomes of patient groups with vs. without performing CT (non-CT group vs. CT group). Results: After performing CT, the diagnosis was changed for two (3.0%) while additional diagnoses were made for 27 of the 64 patients (42.1%). However, the treatment changed for only one (1.5%), and six patients (9.3%) received supplementary medication. There were no difference in the median length of hospital stay (8 [6-13] days vs. 8 [6-12] days, p=0.786) and intensive care unit care (14 [10.1%] vs. 11 [16.7%], p=0.236) between the CT and non-CT groups, respectively. These findings remained consistent even after the propensity score matching. Conclusion: Utility of CT in patients with acute COPD exacerbation might not be helpful; therefore, we do not recommend chest CT scan as a routine initial diagnostic tool.

방사선 일반 정면검사에서 허리뼈 추간판 계측 값에 따른 입사각 적용 (Application of Incidence Angle on Lumbar Spine Anteroposterior General Radiography Image according to Measured Intervertebral Disc Angle)

  • 문슬지아;김경립;조희정;성순기;곽종혁
    • 한국콘텐츠학회논문지
    • /
    • 제19권6호
    • /
    • pp.471-480
    • /
    • 2019
  • 정상인을 대상으로 체질량지수, 전만각도에 따른 L-spine 3~4, L-spine 4~5, L-spine 5~Sacrum 1의 각각의 추간판각도를 비교 분석하여 입사각을 제시하였다. 체질량지수의 L-spine 3~4, L-spine 4~5, L-spine 5~Sacrum 1의 정면 입사각도는 머리 쪽 방향으로 5.66도, 13.23도, 29.13도였으며, 전만각도의 L-spine 3~4, L-spine 4~5, L-spine 5~Sacrum 1의 정면 입사각도는 머리 쪽 방향으로 6.32도, 16.09도, 35.36도였다. 체질량지수, 전만각도에 따른 정면 입사각도에 따라 적용한 팬텀의 일반 전후방향 영상의 왜곡정도를 면적비율로 비교한 결과 L-spine 4~5, L-spine 5~Sacrum 1의 추간판각도에서 유의미한 차이가 있었고(p<0.05), 전만각도와 추간판각도는 양의 상관관계를 보였다(p<0.05). 팬텀의 전만각도에 따른 추간판각도 계측 값을 머리 쪽 방향으로 입사각을 L4는 11도, L5는 26도로 적용하여 영상의 유용성을 평가한 결과, 왜곡비율면적은 L4에서 14.90%에서 12.11%로 줄어들었고, L5에서는 15.25%에서 13.72%로 줄어들었다. 계측된 추간판 각도에 따른 입사각을 적용한 허리뼈 일반 전후방향 영상에서 허리뼈 4번, 5번을 목적으로 하는 허리뼈 정면 영상에서 왜곡을 줄여, 정확한 구조의 정면 추체상과 인접하는 관절 간 영상을 얻을 수 있었고, 목적하는 부위의 영상의 질과 진단적 정보를 향상시킬 수 있었다.

흉부 전산화단층촬영에서 우연히 발견된 유방 병변: 임상적 중요성 및 진료 의뢰가 필요한 특징적 영상 소견 (Incidental Breast Lesions on Chest CT: Clinical Significance and Differential Features Requiring Referral)

  • 최윤정;김태훈;차윤진;손은주;권혜미;박철환
    • 대한영상의학회지
    • /
    • 제79권6호
    • /
    • pp.303-310
    • /
    • 2018
  • 목적: 이 연구의 목적은 흉부 전산화단층촬영(CT)에서 우연히 발견된 유방 병변의 임상적 중요성을 평가하고 유방 전문 진료 의뢰가 필요한 영상 소견을 제안하는 것이다. 대상과 방법: 2009년 5월부터 2014년 4월까지 촬영된 조영증강 흉부 CT 중에서 판독문에 '유방'이라는 단어가 포함된 검사를 후향적으로 검토하였다. 이 중 우연히 발견된 유방 병변으로 유방 초음파와 유방 촬영술을 한 뒤, 병리학적 확인이나 1년 이상의 추적 관찰을 받은 총 86명의 환자(모두 여성, 평균 연령, $48.9{\pm}12.6$세)를 대상으로 하였다. 흉부 CT에서 유방 병변의 크기, 위치, 모양, 경계 및 조영 증강을 포함한 영상 특징을 평가하였다. 다양한 CT 특징과 병리소견과의 연관성을 평가하고 여러 조합의 CT 특징의 진단 정확도를 평가하였다. 결과: 흉부 CT에서 우연히 발견된 유방 병변 중 악성 종양은 16.3%(14/86)였다. 악성 병변은 양성 병변에 비해 불규칙한 모양, 불분명한 경계, 높은 조영증강을 보였다. CT 특징의 조합 중 불분명한 경계와 높은 조영증강의 조합이 악성 병변을 예측하는데 가장 높은 정확도를 보였다(97.7%). 결론: 흉부 CT에서 우연히 발견된 유방 병변의 16.3%는 악성이었으며, 불분명한 경계와 높은 조영증강을 동시에 보일 경우 악성 가능성이 높으므로, 정확한 진단을 위해 유방 전문 진료 의뢰가 필요하다.

Association Between Low Muscle Mass and Non-alcoholic Fatty Liver Disease Diagnosed Using Ultrasonography, Magnetic Resonance Imaging Derived Proton Density Fat Fraction, and Comprehensive NAFLD Score in Korea

  • Lee, Hun Ju;Chang, Jae Seung;Ahn, Jhii Hyun;Kim, Moon Young;Park, Kyu-Sang;Ahn, Yeon-Soon;Koh, Sang Baek
    • Journal of Preventive Medicine and Public Health
    • /
    • 제54권6호
    • /
    • pp.412-421
    • /
    • 2021
  • Objectives: Non-alcoholic fatty liver disease (NAFLD) is an increasingly prevalent metabolic disease. Muscle is known to influence NAFLD development. Therefore, this study aimed to determine the relationships among low muscle mass, NAFLD, and hepatic fibrosis using various definitions of low muscle mass and NAFLD diagnostic methods, including magnetic resonance imaging-based proton density fat fraction (MRI-PDFF). Methods: This cross-sectional study included 320 participants (107 males, 213 females) from the Korean Genome and Epidemiology Study on Atherosclerosis Risk of Rural Areas in the Korean General Population cohort. Muscle mass was assessed using whole-body dual-energy X-ray absorptiometry and adjusted for the height squared, body weight, and body mass index (BMI). NAFLD was diagnosed using ultrasonography (US), MRI-PDFF, and the comprehensive NAFLD score (CNS). Hepatic fibrosis was assessed using magnetic resonance elastography. Multivariable logistic and linear regression analyses were performed to determine the aforementioned associations. Results: According to US, 183 participants (57.2%) had NAFLD. Muscle mass adjusted for body weight was associated with NAFLD diagnosed using US (odds ratio [OR], 3.00; 95% confidence interval [CI], 1.70 to 5.31), MRI-PDFF (OR, 2.00; 95% CI, 1.13 to 3.53), and CNS (OR, 3.39; 95% CI, 1.73 to 6.65) and hepatic fibrosis (males: β=-0.070, p<0.01; females: β=-0.037, p<0.04). Muscle mass adjusted for BMI was associated with NAFLD diagnosed by US (OR, 1.71; 95% CI, 1.02 to 2.86) and CNS (OR, 1.95; 95% CI, 1.04 to 3.65), whereas muscle mass adjusted for height was not associated with NAFLD. Conclusions: Low muscle mass was associated with NAFLD and liver fibrosis; therefore, maintaining sufficient muscle mass is important to prevent NAFLD. A prospective study and additional consideration of muscle quality are needed to strengthen the findings regarding this association.

구내 촬영용 엑스선 장치의 관전류에 따른 영상 평가 (Image Evaluation according to Tube Current of X-ray Device for Intraoral Imaging)

  • 김아연;조병두;이승재
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.515-521
    • /
    • 2023
  • 치과 구내 촬영 시 사용하는 관전류 및 시간에 따라 환자가 받는 피폭선량은 달라진다. 영상의 질을 위해서는 많은 양의 관전류가 필요하지만, 환자에게 부여되는 방사선량은 그만큼 높아진다. 이에 본 연구에서는 시뮬레이션을 통한 치과 구내 촬영 시 사용하는 관전류에 따른 영상의 질 평가를 통해 영상의 질을 확보하면서 환자가 받는 피폭선량은 감소시킬 수 있는 최적의 관전류 양을 산출하였다. 치과 구내 촬영의 진단참고수준 가이드라인에 제시된 평균 관전류와 시간 및 관전압을 기본 촬영 조건으로 사용하고, 관전류만 변화시켰을 때 영상을 획득한 후 기본 영상과의 영상의 질 비교·분석을 통해 최적의 관전류 양을 산출하였다. 기본 조건은 63 kV, 6 mA, 0.29 s로 하고 관전류를 0.1, 0.5, 1, 2, 3, 4, 5 mA로 변경시켜 영상을 획득하였다. 획득한 영상은 ICY 프로그램을 사용하여 6 mA의 조건으로 촬영한 영상과 구조적 유사지수를 평가하였다. 그 결과 0.5 mA의 관전류 조건에서도 6 mA의 영상과 구조적 유사지수가 높은 것으로 평가되었다. 이러한 결과를 바탕으로 치과 구내 촬영 시 6 mA가 아닌 0.5 mA로 촬영한다면 환자에게 부여되는 피폭선량을 매우 감소시킬 수 있을 것으로 판단된다.