• 제목/요약/키워드: Diagnostic X-ray

검색결과 600건 처리시간 0.024초

Femoral Metastasis in Bone Mineral Densitometry

  • Han-Kyung Seo;Do-Cheol Choi;Cheol-Min Shim;Jin-Hyeong Jo
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.7-8
    • /
    • 2023
  • A 50-year-old female patient referred by the department of breast and thyroid surgery was recommended for orthopedic surgery because lesion like herniation pit was found in the left proximal femur in bone mineral densitometry (BMD). She was later diagnosed with bone metastasis on biopsy in orthopedic surgery. Pelvic X-ray and Lt thigh MRI were performed . Intra-medually nail was operated later. The BMD is a diagnostic method that determines the results by numerical values, so it is inevitable to neglect to observe the bone shape, but as shown in the above case, the examiner's observation of changes in bone shape can return to beneficial treatment for patients.

  • PDF

의료영상용 방사선방호를 위한 무납차폐체 개발 (Development of Lead Free Shielding Material for Diagnostic Radiation Beams)

  • 최태진;오영기;김진희;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제21권2호
    • /
    • pp.232-237
    • /
    • 2010
  • 본 연구에서는 의학영상장치의 방사선에너지스펙트럼과 중원자번호 물질의 방사선흡수특성을 이용하여 경량 재질의 무납차폐체를 개발하였다. 개발된 차폐체는 중량비율로 주석 34.1%, 안티몬 33.8%, 요오드 26.8%와 Polyisoprene 5.3%를 혼합하여 가로$\times$세로$\times$두께 $200{\times}200{\times}1.5\;(mm^3)$로 제작되었으며 밀도는 $3.2\;g/cm^3$이다. 무납차폐체의 무게는 표준납차폐체 무게의 84%로 연당량 0.42 mm에 해당되며, 제작된 무납차폐체는 일차선과 산란선에 대해 표준납차폐체(연당량 0.5 mm 두께)의 투과율과 비교하였다. 일차선 에너지는 50 kVp에서 20 kVp씩 증가하여 110 kVp까지 조사 되었으며, 표준납 차폐체의 투과율은 0.1%, 0.9%, 3.2%, 4.8%였고, 무납차폐체는 각각 0.3%, 0.6%, 2.0%, 4.2%를 보였으며, 오차는 ${\pm}0.1$%이었다. 표준납차폐체와 동등한 연당량의 무납차폐체의 투과율은 각각 0.1%, 0.3%, 1.0%와 2.4%로 저에너지에서는 납과 동일한 감쇠를 나타내었으나 높은 에너지영역 에서는 납의 30~50%의 투과율로 측정되어 차폐효과가 뛰어남을 알 수 있었다. 인체팬텀의 측방산란선에 대한 비교결과는 표준납차폐체가 2.4%, 2.5%, 4.2%, 5.1%를 보였고, 무납차폐체는 각각 2.4%, 3.3%, 4.6%와 5.9%이며 각 오차는 ${\pm}0.2%$였다. 혼합성분의 무납차폐체의 연당량을 표준납차폐체까지 올리는 경우 낮은 에너지에서 뿐만 아니라 높은 에너지 영역에서 납에 비해 월등히 감쇠효과가 있음을 주장하며, 방사선구역의 특성에 따라 경량의 차폐체를 이용함으로써 방사선피폭을 효과적으로 차폐할 수 있을 것이다.

급성기 Mycoplasma 폐렴의 항체가와 검사소견에 관한 고찰 (Clinical Evaluation of Mycoplasma pneumoniae Antibody Titer and Laboratory Tests in Acute Mycoplasma pneumoniae Pneumonia)

  • 이은희;이소라;김화인;김종덕
    • Pediatric Infection and Vaccine
    • /
    • 제6권1호
    • /
    • pp.93-100
    • /
    • 1999
  • 목 적 : Mycooplasma 폐렴은 소아과 영역에서 통상 사용하지 않는 macrolide 계열의 항생 제에 감수성이 있어서 초기에 신속한 진단이 중요한데, 이에 저자들은 발병 1주일 이내의 Mycoplasma 폐렴 환아에서 Mycoplasma 항체역가, 냉혈응집소역가, ESR, CRP 등과 임상 소견을 검토하여 진단에 어떤 의의가 있는지 알아보고자 하였다. 방 법 : 1997년 1월부터 12월까지 원광의대병원 소아과에 입원하여 Mycoplasma 폐렴으로 진단되어 치료를 받았던 환아 중에 입원 전에 발열과 기침이 7일 이내였던 환아 56명을 대상으로 M. pneumoniae 균의 항체검사를 시행하였다. 대상 환아를 항체역가가 1:320 미만이었던 어린이 33명(A군)과 1:640 이상이었던 어린이 23명(B군)으로 나누어 입원시에 총 백혈구수와 분획, 혈구 침강속도 및 CRP와, 냉혈응집소치, 흉부 X-선 소견을 비교 검토하였다. Mycoplasma 폐렴의 진단 기준은 기침과 발열 등의 임상증상과 흉부 청진상수포음의 존재, 흉부 X-선 소견상 폐 실질에 침윤을 보이며 indirect particle agglutination test로 측정한 Mycoplasma 항체가가 1:640 이상이거나, 1주일 후에 재검사에서 4배 이상 역가가 증가한 경우로 하였으며 냉혈응집소는 역가가 1:64 이상인 경우를 양성 판정하였다. 결 과 : 1) 남녀 비는 1:1.4이었고 평균연령은 $5.8{\pm}2.96$세 이었다. 2) 내원시 평균 체온은 $38.5{\pm}0.1^{\circ}C$이었으며 52례(93%)에서 객담성 기침이 관찰되었다. 3) 총백혈구수는 Mycoplasma 항체 역가가 640이상으로 높았던 어린이군에서 $10,470{\pm}877.0/mm^3$로 320 이하이었던 어린이군 $7,761{\pm}508.5/mm^3$에 비해 의의 있게 높았다(P<0.014). 4) 혈구침강속도와 CRP는 각각 $27.2{\pm}26.82/mm/hr$, $39.9{\pm}41.50ng/mL$로 의미 있는 상승을 보이지 않았다. 5) 입원시 흉부 X-선 소견상 폐 침윤은 우측폐에 24례(43%)로 가장 흔하게 볼 수 있었고 이중에서도 우측 하엽에서 10례로 가장 흔하였다. 6) 냉혈응집소 역가는 Mycoplasma 항체 역가와 의의 있는 상관 관계를 보이지 않았고 25례(45%)에서 냉혈응집소 역가가 1:64 미만이었다. 결 론 : 발병초기 Mycoplasma 폐렴의 진단은 임상증상, 흉부 X-선 소견 및 항체검사가 유용하며 초기 항체 역가는 임상소견의 정도와는 무관하므로 항체검사가 필수적이며 냉혈응 집소검사는 양성률이 낮아서 발병초기에 Mycoplasma 폐렴의 진단에 도움을 주지 못할 것으로 사료된다.

  • PDF

X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석 (Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model)

  • 김도일;김성현;호동수;최보영;서태석;이재문;이형구
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.202-209
    • /
    • 2004
  • 현재 평판 디텍터를 이용한 디지털 방사선 촬영기술은 방사선 진단 기술 분야에 있어서 매우 중요하고 유용하게 사용되고 있다. 비정질 실리콘 광센서를 사용하는 디지털 방사선 촬영기에는 흡수되는 방사선 에너지를 가시광선으로 변환하는 신틸레이터로 보통 CsI(TI)를 사용한다. 신틸레이터에서 만들어진 가시광선은 이차원 평면으로 구성된 비정실 실리콘 광 다이오드에서 전기적 신호로 전환된다. 좋은 질의 영상을 얻기 위해서는 디지털 방사선 촬영기(Digital Radiography, DR) 디텍터의 방사선에 대한 세부적인 특성 연구가 필수적이다. 이러한 이유로 조사선량과 디지털 방사선 촬영기의 신호의 관계에 대해서 많은 연구가 이루어졌지만 현재까지의 연구에서는 고정된 관전압의 조건에서 두 변수의 관계에 대한 연구가 이루어졌다. 이에 본 연구에서는 X선 스펙트럼 모델인 SPEC-78을 사용하여 조사선량 대신 디텍터에 흡수되는 에너지와 디지털 방사선 촬영기의 신호와의 관계를 규명하였다. SPEC-78의 주요 입력변수인 X-ray 튜브의 고유 필터 값을 구하기 위해 조사선량을 측정하여 계산한 조사선량과 비교하였다. 물질에 흡수되는 X-ray의 에너지를 계산하는 알고리즘을 상정하여 디텍터에 흡수되는 에너지를 계산하고 다양한 조건에서 실제 X선 영상의 화소값을 획득하였다. 두변수의 관계를 이용해 특성곡선을 얻었으며 이 결과를 검증하기 위해서 물과 알루미늄으로 제작된 팬텀을 이용하였다. 다양한 조건에서 팬텀 영상의 화소값을 측정하였고 특성곡선과 비교하였다 이러한 과정으로 진행된 연구의 결과로 디텍터에 흡수되는 에너지와 디지털 방사선 촬영기의 신호는 거의 선형적임을 알 수 있었다. 또한 팬텀을 이용한 실험에서도 산란된 광자의 영향으로 유발된 약간의 오차에도 불구하고 측정되어진 화소값은 특성곡선과 잘 일치하였다 본 연구를 통해 규명되어진 두 변수의 관계는 예상과 거의 일치하였지만 산란선에 대한 부분은 흡수에너지 계산 알고리즘에서 빠져있어 더 연구가 되어야 할 부분이다. 본 연구를 통해 얻어진 자료들은 디지털 방사선 촬영기의 전처리 과정에 있어서 중요한 정보를 제공할 수 있을 것이라 생각된다.

  • PDF

Down the Rabbit Hole-Considerations for Ingested Foreign Bodies

  • Brown, Jerry;Kidder, Molly;Fabbrini, Abigail;deVries, Jonathan;Robertson, Jason;Chandler, Nicole;Wilsey, Michael
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제22권6호
    • /
    • pp.619-623
    • /
    • 2019
  • We report the case of a seven-year-old boy with an ingested foreign body, which was retained within the appendix for a known duration of ten months, ultimately requiring appendectomy. The ingested foreign body was incidentally discovered by abdominal x-ray at an emergency room visit for constipation. Despite four bowel cleanouts, subsequent x-rays showed persistence of the foreign body in the right lower quadrant. While the patient did not have signs or symptoms of acute appendicitis, laparoscopic appendectomy was performed due to the risk of this foreign body causing appendicitis in the future. A small metallic object was found within the appendix upon removal. This case highlights the unique challenge presented by foreign body ingestions in non-verbal or developmentally challenged children and the importance of further diagnostic workup when concerns arise for potential retained foreign bodies.

인체 각 부위의 PET/MRI와 PET/CT의 SUV 변화 (Comparison of SUV for PET/MRI and PET/CT)

  • 김재일;전재환;김인수;이홍재;김진의
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.10-14
    • /
    • 2013
  • Purpose: Due to developed simultaneous PET/MRI, it has become possible to obtain more anatomical image information better than conventional PET/CT. By the way, in the PET/CT, the linear absorption coefficient is measured by X-ray directly. However in case of PET/MRI, the value is not measured from MRI images directly, but is calculated by dividing as 4 segmentation ${\mu}-map$. Therefore, in this paper, we will evaluate the SUV's difference of attenuation correction PET images from PET/MRI and PET/CT. Materials and Methods: Biograph mCT40 (Siemens, Germany), Biograph mMR were used as a PET/CT, PET/MRI scanner. For a phantom study, we used a solid type $^{68}Ge$ source, and a liquid type $^{18}F$ uniformity phantom. By using VIBE-DIXON sequence of PET/MRI, human anatomical structure was divided into air-lung-fat-soft tissue for attenuation correction coefficient. In case of PET/CT, the hounsfield unit of CT was used. By setting the ROI at five places of each PET phantom images that is corrected attenuation, the maximum SUV was measured, evaluated %diff about PET/CT vs. PET/MRI. In clinical study, the 18 patients who underwent simultaneous PET/CT and PET/MRI was selected and set the ROI at background, lung, liver, brain, muscle, fat, bone from the each attenuation correction PET images, and then evaluated, compared by measuring the maximum SUV. Results: For solid $^{68}Ge$ source, SUV from PET/MRI is measured lower 88.55% compared to PET/CT. In case of liquid $^{18}F$ uniform phantom, SUV of PET/MRI as compared to PET/CT is measured low 70.17%. If the clinical study, the background SUV of PET/MRI is same with PET/CT's and the one of lung was higher 2.51%. However, it is measured lower about 32.50, 40.35, 23.92, 13.92, 5.00% at liver, brain, muscle, fat, femoral head. Conclusion: In the case of a CT image, because there is a linear relationship between 511 keV ${\gamma}-ray$ and linear absorption coefficient of X-ray, it is possible to correct directly the attenuation of 511 keV ${\gamma}-ray$ by creating a ${\mu}$map from the CT image. However, in the case of the MRI, because the MRI signal has no relationship at all with linear absorption coefficient of ${\gamma}-ray$, the anatomical structure of the human body is divided into four segmentations to correct the attenuation of ${\gamma}-rays$. Even a number of protons in a bone is too low to make MRI signal and to localize segmentation of ${\mu}-map$. Therefore, to develope a proper sequence for measuring more accurate attenuation coefficient is indeed necessary in the future PET/MRI.

  • PDF

폐경 전후 여성의 요추 골밀도와 심혈관 위험인자와의 연관성 (The Relationship Between Lumbar Spine Bone Mineral Density and Cardiovascular Risk Factors in Premenopausal and Postmenopausal Women)

  • 김미영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권4호
    • /
    • pp.365-371
    • /
    • 2007
  • 최근 연구들은 골다공증과 동맥경화증의 병인 간의 연관성을 제시한다. 이 연구에서는 건강한 중년 여성에서 high-sensitivity C-reactive protein(hs-CRP), 지질 농도 등을 포함한 심혈관 위험인자들과 요추 골밀도의 상관관계를 분석하였다. 총 300명의 성인여성을 대상으로 하여 신체계측을 시행하였고, 공복혈당, 지질, hs-CRP를 포함한 심혈관질환 위험인자들을 측정하였다. 동맥경화지수는 총콜레스테롤 농도를 고밀도지단백 콜레스테롤 농도로 나누어서 계산하였다. Dual X-ray abosorptiometry를 이용하여 요추 골밀도를 측정하였다. 연구결과 연령, 수축기 및 이완기 혈압, 총 콜레스테롤, 고밀도지단백 콜레스테롤은 요추 골밀도와 음의 상관관계를 보였다. 통계적으로는 연령과 체질량지수, 고밀도지단백 콜레스테롤이 요추 골밀도와 의미 있는 상관관계를 보였다. 요추 골밀도에 영향을 미치는 심혈관 인자들은 연령과 고밀도지단백 콜레스테롤이 요추 골밀도($R^2=0.272$)의 독립적 위험인자로 나타났다.

  • PDF

이중에너지 X선 흡수계측법을 이용한 폐경기 여성의 요추 및 근위 대퇴부의 골밀도 비교 연구 (A Comparative Study on BMD of Lumbar Spine and Proximal Femur in Post-Menopausal Women Using Dual Energy X-ray Absorptiometry)

  • 윤한식;모은희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권2호
    • /
    • pp.41-46
    • /
    • 1999
  • Osteoporosis, which causes mainly fracture of the spine, proximal femur and distal radius by minimal trauma, is a major public health problem and its prevalence is steadily increasing in Korea according to the development of public health care. There are reliable methods for diagnosis based on bone densitometry. Early detection and intervention are important for reducing the incidence of fractures. A consensus definition of osteoporosis, based on bone density measurement, has been developed by the World Health Organization(WHO). In this study, bone mineral density(RMD) was measured by dual energy x-ray absorptiometry(DEXA) at the proximal femur and lumbar spine in 132 post-menopausal women. The purpose of this study is to find influential factors on the BMD of the proximal femur and the lumbar spine and to analyze correlation between BMD and the problematic factors. We obtained the following results : 1. Mean BMD score, T-score and Z-score of the proximal femur were $0.81(g/cm^2)$, -2.45(S.D.) and -2.09(S.D.) respectively and in the lumbar spine were $0.83(g/cm^2)$, -2.02(S.D.), -2.43(S.D.) respectively. 2. In correlation analysis between BMD and many factors, correlation coefficients were -0.467, 0.212, -0.321 and 0.241 in age, height, duration after menopause respectively. BMI and the residuals were comparatively small. 3. Correlation coefficients to age matched BMD, in height and body weight were 0.222 and 0.241, in age and duration after menopause were -0.268, -0.282. 4. The fracture threshold of proximal femur BMD to the 90th percentile was $0.845(g/cm^2)$. 5. At the result of multiple regression analysis, age, body weight, $BMI(kg/m^2)$ and duration after menopause described as significant variables.

  • PDF

Abell 2261: a fossil galaxy cluster in a transition phase

  • Kim, Hyowon;Ko, Jongwan;Kim, Jae-woo;Smith, Rory;Song, Hyunmi;Hwang, Ho Seong
    • 천문학회보
    • /
    • 제43권1호
    • /
    • pp.58.2-58.2
    • /
    • 2018
  • Fossil groups of galaxies have characteristic features of a dominant central elliptical galaxy (${\Delta}M_{12}$ > 2 in $0.5R_{vir}$) embedded in highly relaxed X-ray halo, which indicates dynamically stable and evolved systems. These are thought as a final stage of the evolution of galaxy groups in the hierarchical structure formation scenario. However, the formation and evolution of fossil clusters are still unclear due to lack of detailed studies. Therefore, we perform a kinematic research of a known fossil cluster Abell 2261 (A2261 hereafter) using spectroscopic data of 589 galaxies in the A2261 field. Even though A2261 is known as a fossil cluster, previous studies found several unusual features such as quite high X-ray entropy for a stable cluster, and an elongated shape, which are not expected in standard fossil clusters. Using the caustic method, we identify cluster member galaxies and discover a second bright galaxy (${\Delta}M_{12}=1.68$) at ${\sim}1.5R_{vir}$. The presence of such a bright galaxy can break the current fossil state of cluster in the near future. In addition, with two independent substructure finding methods, we confirm that the previously detected elongated galaxy distribution of the cluster is a real feature. These findings indicate that A2261 is not in a fully stable state, unlike the existing fossil definition diagnostic. We require a more stringent criterion for the fossil definition to represent a genuinely final stage of cluster evolution.

  • PDF

Correlation between Bone Mineral Density Measured by Dual-Energy X-Ray Absorptiometry and Hounsfield Units Measured by Diagnostic CT in Lumbar Spine

  • Lee, Sungjoon;Chung, Chun Kee;Oh, So Hee;Park, Sung Bae
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권5호
    • /
    • pp.384-389
    • /
    • 2013
  • Objective : Use of quantitative computed tomography (CT) to evaluate bone mineral density was suggested in the 1970s. Despite its reliability and accuracy, technical shortcomings restricted its usage, and dual-energy X-ray absorptiometry (DXA) became the gold standard evaluation method. Advances in CT technology have reduced its previous limitations, and CT evaluation of bone quality may now be applicable in clinical practice. The aim of this study was to determine if the Hounsfield unit (HU) values obtained from CT correlate with patient age and bone mineral density. Methods : A total of 128 female patients who underwent lumbar CT for back pain were enrolled in the study. Their mean age was 66.4 years. Among them, 70 patients also underwent DXA. The patients were stratified by decade of life, forming five age groups. Lumbar vertebrae L1-4 were analyzed. The HU value of each vertebra was determined by averaging three measurements of the vertebra's trabecular portion, as shown in consecutive axial CT images. The HU values were compared between age groups, and correlations of HU value with bone mineral density and T-scores were determined. Results : The HU values consistently decreased with increasing age with significant differences between age groups (p<0.001). There were significant positive correlations (p<0.001) of HU value with bone mineral density and T-score. Conclusion : The trabecular area HU value consistently decreases with age. Based on the strong positive correlation between HU value and bone mineral density, CT-based HU values might be useful in detecting bone mineral diseases, such as osteoporosis.