• 제목/요약/키워드: Diagnostic X-ray

검색결과 600건 처리시간 0.023초

Diagnostic reference levels in intraoral dental radiography in Korea

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Jung, Yun-Hoa;Yoon, Suk-Ja;Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • 제42권4호
    • /
    • pp.237-242
    • /
    • 2012
  • Purpose: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. Materials and Methods: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. Results: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 $mGycm^2$ (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 $mGycm^2$ (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). Conclusion: We recommend 3.1 mGy (PED), 87.4 $mGycm^2$ (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

방사성동위원소정맥촬영술(放射性同位元素靜脈撮影術)의 진단적(診斷的) 의의(意義) - X-선정맥조영술(線靜脈造影術)과의 비교(比較) 연구(硏究) - (Diagnostic Significance of Radionuclide Venography - A Comparison with X-ray Contrast Venography -)

  • 배상훈;박재형;한만청;조보연;고창순
    • 대한핵의학회지
    • /
    • 제15권2호
    • /
    • pp.19-25
    • /
    • 1981
  • Radionuclide venographies were performed in 138 limbs of 58 patients and X-ray contrast venographies were performed in 23 paitents of them. Positive radionuclide venography findings were area of decreased sponding to the region of thrombosis, abnormal collateral flows below the lesion. The success rate of radionulide venography was 89% and the overall concordance between radionuclide venography and X-ray contrast venography was 91%. Radionuclide venography is simple and easy to perform and less invasive than X-ray contrast venography. These results indicate that radionuclide venography is the most ideal screening test for the detection of venous thrombosis in patient with signs & symptoms of deep vein thrombosis.

  • PDF

다양한 X-ray 촬영조건을 이용하여 획득한 skull 영상에서의 Total Variation 알고리즘의 가능성 연구 (A Study on Feasibility of Total Variation Algorithm in Skull Image using Various X-ray Exposure Parameters)

  • 박성우;이종인;이영진
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.765-771
    • /
    • 2019
  • Skull X-ray 영상에서 노이즈의 발생은 불가피하며, 이는 영상 화질과 진단 정확도를 저하시키고 디지털 영상 장치의 특성상 오류를 증가시킨다. 이러한 노이즈는 선량을 증가시키면 쉽게 감쇠되긴 하지만 환자가 받는 피폭선량이 더 큰 문제를 야기할 수 있다. 그래서 선량문제를 해결하고 동시에 노이즈를 줄이기 위해저 선량에서 노이즈 감소 알고리즘이 활발히 연구되고 있는데, 초기에 개발되고 널리 사용되어진 median filter와 Wiener filter는 노이즈 감소 효율이 떨어지고 영상경계에 대한 정보가 많이 손실된다는 단점이 있다. 본 연구의 목적은 이전 노이즈 감소효율의 문제점을 보완할 수 있는 total variation (TV) 알고리즘을 skull X-ray 영상에 적용하여 정량적으로 평가하고 비교를 하는 것이다. 이를 위해 Siemens사의 X-ray 장치를 사용하여 성인 skull을 모사할 수 있는 팬텀을 통해 다양한 관전압과 관전류량을 사용하여 실제 skull X-ray 팬텀 영상을 획득하였다. 또한, 각각의 팬텀 영상에 noisy image, median filter, Wiener filter, TV 알고리즘을 적용하였을 때의 대조도 대 잡음비 (CNR)와 변동계수 (COV)를 비교 측정했다. 실험 결과 TV 알고리즘을 적용하였을 때, 모든 조건에서 CNR와 COV 특성이 우수함을 확인할 수 있었다. 결론적으로 이번 연구를 통해 TV 알고리즘을 사용하여 영상의 질을 높일 수 있는지에 대해 확인해 보았고, 이론적으로 CNR 값은 관전류량이 증가할수록 노이즈가 감소함으로 인해 증가하는 것을 알아볼 수 있었다. 반면에, COV는 관전류량이 증가할수록 감소하였으며 관전압이 증가하였을 때 noise는 감소하고 투과량이 증가하여 COV가 감소하는 것을 알아볼 수 있었다.

종합병원 일반 및 특수촬영유니트의 건축계획에 관한 연구 (A Study on the Architectural Planning of the X-ray Unit in General Hospital)

  • 윤우용;채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제12권3호
    • /
    • pp.27-34
    • /
    • 2006
  • Planning for the space of the Media Medical Department requires the details about the efficiency of the equipment and the operation in professional sector. For that, as designing, it is necessary to keep communicating with the experts on the technology and the officials from the company producing the equipment. One of the common concerns is not only how to insure enough room for the future extension and the upgrade of the equipment, as concerning the scale of the hospital, but the plan to cover movie cameras. As technology has been developed, despite the fact that machinery tend to be small, it can be possible to require continuously about the concerns of the scale because the camera taking body-picture tend to be much bigger and more complicated than before. Currently used diagnostic media techniques are divided by the method and the feature of the equipment such as Diagnostic X-ray, Ultrasound, CT, MRI, Angiography. The general and special photographing units which are used more than the other diagnostic parts, must be planned not for experiencing any inconvenience and unnecessary risks for the patients and must accept technical requirements. Also, it must be designed not to be seen as a clinic zone, as concerning the psychological stability of the patients. However, study of the general and special photographing units among the domestic general hospitals is insufficient. Also, as there is shortage of the material considering the development of the equipment, when planning, it's involving a lot of difficulties. Thus, this study has got a purpose on giving the basic material which is essential for further study, as suggesting the planning guidelines and the alternative plans for the general and special photographing units in a general hospital.

  • PDF

Application of X-ray Computer Tomography (CT) in Cattle Production

  • Hollo, G.;Szucs, E.;Tozser, J.;Hollo, I.;Repa, I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제20권12호
    • /
    • pp.1901-1908
    • /
    • 2007
  • The aim of this series of experiments was to examine the opportunity for application of X-ray computer tomography (CT) in cattle production. Firstly, tissue composition of M. longissimus dorsi (LD) cuts between the $11-13^{th}$ ribs (in Exp 1. between the $9-11^{th}$ ribs), was determined by CT and correlated with tissue composition of intact half carcasses prior to dissection and tissue separation. Altogether, 207 animals of different breeds and genders were used in the study. In Exp. 2 and 3, samples were taken from LD cuts, dissected and chemical composition of muscle homogenates was analysed by conventional procedures. Correlation coefficients were calculated among slaughter records, tissues in whole carcasses and tissue composition of rib samples. Results indicated that tissue composition of rib samples determined by CT closely correlated with tissue composition results by dissection of whole carcasses. The findings revealed that figures obtained by CT correlate well with the dissection results of entire carcasses (meat, bone, fat). Close three-way coefficients of correlation (r = 0.80-0.97) were calculated among rib eye area, volume of cut, pixel-sum of adipose tissue determined by CT and intramuscular fat or adipose tissue in entire carcasses. Estimation of tissue composition of carcasses using equations including only CT-data as independent variables proved to be less reliable in prediction of lean meat and bone in carcass ($R^2 = 0.51-0.86$) than for fat (($R^2 = 0.83-0.89$). However, when cold half carcass weight was also included in the equation, the coefficient of determination exceeded $R^2 = 0.90$. In Exp. 3 tissue composition of rib samples by CT were compared to the results of EUROP carcass classification. Findings revealed that CT analysis has higher predictive value in estimation of actual tissue composition of cattle carcasses than EUROP carcass classification.

국내 동물병원의 진단용 방사선 발생장치 및 방사선 관계종사자 안전관리에 관한 융복합적 분석 (Convergence analysis of safety management for radiation workers and diagnostic radiation-generator devices of animal hospital in Korea)

  • 강경묵;서태영;김용상;윤선종
    • 한국융합학회논문지
    • /
    • 제11권4호
    • /
    • pp.55-61
    • /
    • 2020
  • 다양한 종류의 방사선 발생장치가 동물병원에서 사용되면서 방사선 관계종사자들의 안전이 중요해지고 있으나 방사선 발생장치 및 방사선 관계종사자들에 대한 안전관리 정보가 없는 실정이다. 이에 본 연구에서는 방사선 검사기관 및 측정기관, 시·군·구에서 조사되어진 방사선 발생장치 및 관계종사자, 피폭선량 등을 조사, 분석하였다. 최근 6년간 동물병원에서의 방사선 발생장치와 관계종사자 수는 각각 2,138대에서 2,972대, 2,644명에서 5,733명으로 증가하였다. 2019년 방사선 발생장치의 수는 일반 X-ray, CT, C-arm, 이동형 X-ray, 치과용 X-ray는 각각 2,204대, 58대, 67대, 770대, 14대인 것으로 조사되었다. 2019년 방사선 관계종사자 수는 수의사 4,236명, 수의간호사 1,080명, 업무보조원 404명, 기타 13명인 것으로 조사되었다. 2018년 방사선 관계종사자 연간평균피폭선량은 표층선량 0.21mSv, 심부선량 0.18mSv인 것으로 나타났다. 본 연구는 동물병원에서 사용하고 있는 방사선 발생장치 및 방사선 관계종사자의 안전관리에 대한 기초 자료가 될 것으로 기대한다.

전파정류 방식을 사용한 의료용 X선 장치의 성능평가

  • 김영표;김태곤;이호식;천민우;박용필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.248-248
    • /
    • 2009
  • Diagnostic X-ray system has been contributed to wiping out disease to get a good quality images from patients. But, X-ray radiation could be exposed to patient and it is very harmful to the patient. In order to reduce being bombed, the many research and development is now advanced. This research has produced the high voltage occurrence system of full-wave rectification method by using the LC resonance inverter, and evaluated the irradiation reproducibility in order to use it in diagnosis of the patient.

  • PDF

환자 안전을 위한 비 계측 선량측정의 활용 : NDD-M (Non Dosimetry Measurements Use for Patients Safety : NDD-M)

  • 길종원;선종률;송월수
    • 대한안전경영과학회지
    • /
    • 제18권1호
    • /
    • pp.141-145
    • /
    • 2016
  • This study was to improve to utilization of non dosimetry measurements for X-ray radiography. Experiments was passed off varying the X-ray tube voltage and the thickness of the aluminum filter by actual dose. Calculated results was set to the first beam quality factors, calculated first correction coefficient by the Microsoft Excel program was set as the second beam quality factors. To make the non dosimetry measurements simply, the Excel program apply to the new beam quality factors, the error was compared to the previous studies, and the results verify the calculated value of smaller errors.

37.5kVA급 고주파 공진형 인버터식 진단 X선 전원장치 (A 37.5kV A Class Power Supply for Diagnostic X -ray by High-Frequency Resonant Inverter Type)

  • 김학성;유동욱;임근희;완충연
    • 전자공학회논문지B
    • /
    • 제33B권12호
    • /
    • pp.113-121
    • /
    • 1996
  • This paper presents a 37.5kVA (125kVp, 300mA) high frequency inverter type power supply for diagonostic X-ray generator with two HFHV (high-frequency high-voltage) isolating transformers. The output regulations, X-ray tuve voltage and tube current, are obtained by two high frequency inverters with the each other feedback PI controller and operating time switch for selecting shooting time and synchronizing two inverters. The operating modes and design consideration of the proposed power supply are given. Issues in the design of two HFHV isolating transformersfors high volage genrating and filament heating are discussed. Experimental results are presented to verify the performance of the designed power supply for varying load conditions. The proposed apparatus has several advnatages, e.g., the fast rising time of tube voltae, accuracy and reduced component size etc.

  • PDF

디지털 단층영상합성장치의 영상획득 조건에 따른 화질 분석 (Analysis of Image Quality According to Imaging Parameters in Digital Tomosynthesis)

  • 이다혜;이승완;김번영;임도빈;남기복;조정효
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.477-486
    • /
    • 2020
  • 본 연구는 디지털 단층영상합성장치에서 재구성 필터, X-선원 이동궤적 및 이동간격이 화질에 미치는 영향을 평가하고 임상적 검증을 수행하는 것을 목적으로 한다. 필터링후역투영법 재구성 시 Ramp, Shepp-Logan, Cosine, Hamming, Hann 및 Blackman 필터를 사용하였고, X-선원 이동궤적의 변화를 위해 1 × 36, 2 × 18, 3 × 12, 4 × 9 및 6 × 6 배열 형태의 이동궤적을 모사하였다. X-선원 이동간격에 따른 영향을 평가하기 위해 X-선원간 거리를 5, 10, 20, 30 및 40 mm로 변화시켰다. 재구성 영상의 깊이분해능, 공간분해능 및 잡음을 평가하기 위해 인공물확산함수, 반치폭 및 신호대잡음비를 측정하였다. 연구결과 Ramp 및 Blackman 필터를 사용하였을 때 각각 공간분해능 및 잡음 특성이 최대화 되었으며, X-선원 이동궤적의 형태가 1 × 36일 때 깊이분해능과 잡음 특성이 가장 우수하였다. 또한 X-선원 이동간격이 증가함에 따라 깊이분해능 및 잡음 특성은 향상되었고, 공간분해능은 저하되었다. 따라서 디지털 단층영상합성장치를 통한 3차원 영상획득 시 재구성 필터, X-선원 이동궤적 및 이동간격이 화질에 미치는 영향은 각기 다르며, 진단 목적에 부합하는 조건 설정이 필요하다.