• Title/Summary/Keyword: Diagnostic Information

Search Result 1,412, Processing Time 0.03 seconds

Usefulness of F-18 FDG PET/CT in Adrenal Incidentaloma: Differential Diagnosis of Adrenal Metastasis in Oncologic Patients (부신 우연종에서 F-18 FDG PET/CT의 유용성: 악성 종양 환자에서 부신 전이의 감별진단)

  • Lee, Hong-Je;Song, Bong-Il;Kang, Sung-Min;Jeong, Shin-Young;Seo, Ji-Hyoung;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.421-428
    • /
    • 2009
  • Purpose: We have evaluated characteristics of adrenal masses incidentally observed in nonenhanced F-18 FDG PET/CT of the oncologic patients and the diagnostic ability of F-18 FDG PET/CT to differentiate malignant from benign adrenal masses. Materials and Methods: Between Mar 2005 and Aug 2008, 75 oncologic patients (46 men, 29 women; mean age, $60.8{\pm}10.2$ years; range, 35-87 years) with 89 adrenal masses incidentally found in PET/CT were enrolled in this study. For quantitative analysis, size (cm), Hounsfield unit (HU), maximum standardized uptake value (SUVmax), SUVratio of all 89 adrenal masses were measured. SUVmax of the adrenal mass divided by SUVliver, which is SUVmax of the segment 8, was defined as SUVratio. The final diagnosis of adrenal masses was based on pathologic confirmation, radiologic evaluation (HU<0 : benign), and clinical decision. Results: Size, HU, SUVmax, and SUVratio were all significantly different between benign and malignant adrenal masses.(P < 0.05) And, SUVratio was the most accurate parameter. A cut-off value of 1.0 for SUVratio provided 90.9% sensitivity and 75.6% specificity. In small adrenal masses (1.5 cm or less), only SUVratio had statistically significant difference between benign and malignant adrenal masses. Similarly a cut-off value of 1.0 for SUVratio provided 80.0% sensitivity and 86.4% specificity. Conclusion: F-18 FDG PET/CT can offer more accurate information with quantitative analysis in differentiating malignant from benign adrenal masses incidentally observed in oncologic patients, compared to nonenhanced CT.

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF

Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay (뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성)

  • Byun, Jae-Hu;Park, Myung-Hwan;Lee, Jin-Wan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF

A Survey on Treatment of Breast Cancer Patients with Korean Medicine: Preliminary Research for Clinical Practice Guidelines (한의표준임상진료지침 개발을 위한 유방암 보완치료 실태조사)

  • Kim, Nam-Hoon;Kang, Na-Hoon;Yoo, Eun-Sil;Park, Nam-Chun;Lee, Jin-Wook;Park, Kyoung-Sun;Lee, Jin-Moo;Lee, Chang-Hoon;Jang, Jun-Bock;Jang, Bo-Hyoung;Hwang, Deok-Sang
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.31 no.4
    • /
    • pp.165-178
    • /
    • 2018
  • Objectives: To determine the current status of the treatment of breast cancer patients by Korean Medicine doctors (KMDs) and to examine the need for clinical practice guidelines (CPGs) for the supportive care of these patients. Methods: This cross-sectional study used a self-administered questionnaire. Participants were asked about their experience in treating breast cancer patients; the number of breast cancer patients they currently treat; the main complaints expressed by, diagnoses of, and treatments used for such patients; and their opinions about Korean Medicine (KM) as the basis for providing supportive care for breast cancer. Results: The data for this study were collected from 322 respondents. 84 of whom reported having ever treated patients with breast cancer. Most breast cancer patients who visited the KM clinic were classified as stage I or II, and their major complaints were fatigue, general weakness and musculoskeletal pain. The major diagnostic strategies were syndrome differentiation and pulse diagnosis. The major treatments administered were herbal medicine, acupuncture, and moxibustion. KMDs cited a need for medical information, such as CPGs, as their most important concern with regard to the treatment of breast cancer patients. Conclusions: This survey determined the prevalence of the use of KM for Korean breast cancer patients. Our results underscore the need for clinical practice guidelines for using of KM as the basis of supportive care for breast cancer and for informing clinicians and patients about this approach.

A new diagnostic method for diabetic neuropathy using $TcpO_2$ ($TcpO_2$ 이용한 당뇨병성 신경병증 환자의 조기진단)

  • Hong, Hyun-Ki;Kim, Sung-Woo;Nam, Ki-Chang;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.3
    • /
    • pp.1-8
    • /
    • 2007
  • PDiabetic neuropathy is one of the most common diabetes related complications including diabetic nephropathy and retinopahty. In clinical practices, nerve conduction velocity (NCV) has been used as a standard method for diagnosing diabetic neuropathy. However, it applies maximum current of 100mA to nerves causing stress and pain to patients. In this study, as a non-invasive method, $TcpO_2$ was utilized to investigate the difference and relationship between $TcpO_2$ and $SpO_2$ of normal and diabetic neuropathy subjects. In addition, a new method of diagnosing diabetic neuropathy using $TcpO_2$ is suggested. 50 normal subjects and 50 diabetic patients with neuropathy diagnosed by NCV participated in this study. Parameters used in this study were $TcpO_2$, $TcpCO_2$, and $SpO_2$. As a result of the $TcpO_2$ measurements, statistical significances were found from $TcpO_2$ of hands and feet from normal and patients group(p<0.01). $SpO_2$ measured from index finger of normal and patient groups showed no statistical significance(p>0.05). On the other hand, $SpO_2$ measured from great toes of normal and patient groups showed statistical significance(p<0.01). Correlation coefficient between $SpO_2$ of finger and $TcpO_2$ of hand was 0.400 (p<0.01) and $SpO_2$ of toe and $TcpO_2$ of foot was 0.471(p<0.01). Both correlation values were statistically significant. Sensitivities and specificities of the $TcpO_2$ method were found to be 66 % and 92 %, respectively. If the suggested $TcpO_2$ method is used periodically, prevention and early diagnosis of diabetic neuropathy would be possible.

Genome-wide Association Study Identification of a New Genetic Locus with Susceptibility to Osteoporotic Fracture in the Korean Population

  • Hwang, Joo-Yeon;Lee, Seung-Hun;Go, Min-Jin;Kim, Beom-Jun;Kim, Young-Jin;Kim, Dong-Joon;Oh, Ji-Hee;Koo, Hee-Jo;Cha, My-Jung;Lee, Min-Hye;Yun, Ji-Young;Yoo, Hye-Sook;Kang, Young-Ah;Oh, Ki-Won;Kang, Moo-Il;Son, Ho-Young;Kim, Shin-Yoon;Kim, Ghi-Su;Han, Bok-Ghee;Cho, Yoon-Shin;Koh, Jung-Min;Lee, Jong-Young
    • Genomics & Informatics
    • /
    • v.9 no.2
    • /
    • pp.52-58
    • /
    • 2011
  • Osteoporotic fracture (OF), along with bone mineral density (BMD), is an important diagnostic parameter and a clinical predictive risk factor in the assessment of osteoporosis in the elderly population. However, a genome-wide association study (GWAS) on OF has not yet been clarified sufficiently. To identify OF-associated genetic variants and candidate genes, we conducted a GWAS in a population-based cohort (Korean Association Resource [KARE], n=1,427 [case: 288 and control: 1139]) and performed a de novo replication study in hospital-based individuals (Asan and Catholic Medical Center [ACMC], n=1,082 [case: 272 and control: 810]). In a combined meta-analysis, a newly identified genetic locus in an intergenic region at 10p11.2 (near genes FZD8 and ANKRD30A ) showed the most significant association (odd ratio [OR] = 2.00, 95% confidence interval [CI] = 1.47~2.74, p=$1.27{\times}10^{-6}$) in the same direction. We provide the first evidence for a common genetic variant influencing OF and genetic information for further investigation in bone metabolism.

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

Environmental Tobacco Smoking, Parental Allergy History and Pediatric Asthma and Wheezing (부모에 의한 간접흡연 및 부모의 알레르기성 질환력과 소아 천식과의 관계에 관한 연구)

  • Lee, Keun-Bok;Lee, Weon-Yong
    • Journal of agricultural medicine and community health
    • /
    • v.34 no.2
    • /
    • pp.175-187
    • /
    • 2009
  • Objectives: This study was conducted to investigate whether joint effects between family allergy history and environmental tobacco smoke(ETS) by parents were associated with pediatric asthma and wheezing. Methods: The study objects of this study were 2301 element school students and their parents in an urban-rural areas of Gyeonggi-do. Pediatric asthma and wheezing were identified by measures of International Study of Asthma and Allergies in Childhood (ISAAC) questionnaires. We investigated history of parental allergy, ETS, and other socioeconomic status of both parent. Data were analyzed using logistic regression methods. Results: After adjusting other variables, children with maternal asthma history were more likely to be reported life time wheezing (OR: 3.79 95%CI:2.43-5.90), recent wheezing (OR:4.09 95%CI:2.28-7.38), and diagnostic asthma (OR:2.61 95%CI: 1.44-4.75). Paternal asthma history increasing risk of life time wheezing (OR 2.01 95%CI:1.19-3.38) and recent wheezing (OR:2.38 95%CI:1.24-4.56). Joint effect between parental allergy history and ETS significantly effected on child's life time wheezing and recent wheezing. The risks of life time wheezing (OR:2.47 95%CI:1.64-3.717) and recent wheezing (OR: 2.51 95%CI:1.34-4.69) were significantly higher than others without both factors. The risk of recent wheezing of children with maternal recent smoking and parental allergy history (OR:4.83 95%CI:1.89-12.33) was higher than their counterpart. Conclusions: The result of this study implies that children with family allergy history and passive smoking are more likely to be get asthma and wheezing than children with family allergy history and non-passive smoking. This study provide the object information to increase the efficiency of non-smoking campaign and education for decreasing pediatric asthma risk.

STANDARDIZATION OF WORD/NONWORD READING TEST AND LETTER-SYMBOL DISCRIMINATION TASK FOR THE DIAGNOSIS OF DEVELOPMENTAL READING DISABILITY (발달성 읽기 장애 진단을 위한 단어/비단어 읽기 검사와 글자기호감별검사의 표준화 연구)

  • Cho, Soo-Churl;Lee, Jung-Bun;Chungh, Dong-Seon;Shin, Sung-Woong
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.14 no.1
    • /
    • pp.81-94
    • /
    • 2003
  • Objectives:Developmental reading disorder is a condition which manifests significant developmenttal delay in reading ability or persistent errors. About 3-7% of school-age children have this condition. The purpose of the present study was to validate the diagnostic values of Word/Nonword Reading Test and Letter-Symbol Discrimination Task for the purpose of overcoming the caveats of Basic Learning Skills Test. Methods:Sixty-three reading-disordered patients(mean age 10.48 years old) and sex, age-matched 77 normal children(mean age 10.33 years old) were selected by clinical evaluation and DSM-IV criteria. Reading I and II of Basic Learning Skills Test, Word/Nonword Reading Test, and Letter-Symbol Discrimination Task were carried out to them. Word/Nonword Reading Test:One hundred usual highfrequency words and one hundred meaningless nonwords were presented to the subjects within 1.2 and 2.4 seconds, respectively. Through these results, automatized phonological processing ability and conscious letter-sound matching ability were estimated. Letter-Symbol Discrimination Task:mirror image letters which reading-disordered patients are apt to confuse were used. Reliability, concurrent validity, construct validity, and discriminant validity tests were conducted. Results:Word/Nonword Reading Test:the reliability(alpha) was 0.96, and concurrent validity with Basic Learning Skills test was 0.94. The patients with developmental reading disorders differed significantly from normal children in Word/Nonword Reading Test performances. Through discriminant analysis, 83.0% of original cases were correctly classified by this test. Letter-Symbol Discrimination Task:the reliability(alpha) was 0.86, and concurrent validity with Basic Learning Skills test was 0.86. There were significant differences in scores between the patients and normal children. Factor analysis revealed that this test were composed of saccadic mirror image processing, global accuracy, mirror image processing deficit, static image processing, global vigilance deficit, and inattention-impulsivity factors. By discriminant analysis, 87.3% of the patients and normal children were correctly classified. Conclusion:The patients with developmental reading disorders had deficits in automatized visuallexical route, morpheme-phoneme conversion mechanism, and visual information processing. These deficits were reliably and validly evaluated by Word/Nonword Reading Test and Letter-Symbol Discrimination Task.

  • PDF

Increase of Tc-99m RBC SPECT Sensitivity for Small Liver Hemangioma using Ordered Subset Expectation Maximization Technique (Tc-99m RBC SPECT에서 Ordered Subset Expectation Maximization 기법을 이용한 작은 간 혈관종 진단 예민도의 향상)

  • Jeon, Tae-Joo;Bong, Jung-Kyun;Kim, Hee-Joung;Kim, Myung-Jin;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.344-356
    • /
    • 2002
  • Purpose: RBC blood pool SPECT has been used to diagnose focal liver lesion such as hemangioma owing to its high specificity. However, low spatial resolution is a major limitation of this modality. Recently, ordered subset expectation maximization (OSEM) has been introduced to obtain tomographic images for clinical application. We compared this new modified iterative reconstruction method, OSEM with conventional filtered back projection (FBP) in imaging of liver hemangioma. Materials and Methods: Sixty four projection data were acquired using dual head gamma camera in 28 lesions of 24 patients with cavernous hemangioma of liver and these raw data were transferred to LINUX based personal computer. After the replacement of header file as interfile, OSEM was performed under various conditions of subsets (1,2,4,8,16, and 32) and iteration numbers (1,2,4,8, and 16) to obtain the best setting for liver imaging. The best condition for imaging in our investigation was considered to be 4 iterations and 16 subsets. After then, all the images were processed by both FBP and OSEM. Three experts reviewed these images without any information. Results: According to blind review of 28 lesions, OSEM images revealed at least same or better image quality than those of FBP in nearly all cases. Although there showed no significant difference in detection of large lesions more than 3 cm, 5 lesions with 1.5 to 3 cm in diameter were detected by OSEM only. However, both techniques failed to depict 4 cases of small lesions less than 1.5 cm. Conclusion: OSEM revealed better contrast and define in depiction of liver hemangioma as well as higher sensitivity in detection of small lesions. Furthermore this reconstruction method dose not require high performance computer system or long reconstruction time, therefore OSEM is supposed to be good method that can be applied to RBC blood pool SPECT for the diagnosis of liver hemangioma.