• Title/Summary/Keyword: Diagnostic Information

Search Result 1,412, Processing Time 0.029 seconds

Diagnostic Performance of HPV E6/E7 mRNA and HPV DNA Assays for the Detection and Screening of Oncogenic Human Papillomavirus Infection among Woman with Cervical Lesions in China

  • Wang, Hye-young;Lee, Dongsup;Park, Sunyoung;Kim, Geehyuk;Kim, Sunghyun;Han, Lin;Yubo, Ren;Li, Yingxue;Park, Kwang Hwa;Lee, Hyeyoung
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7633-7640
    • /
    • 2015
  • Background: Human papillomavirus (HPV) is the most common sexually transmitted infection worldwide and it is responsible for most cases of cervical uterine cancer. Although HPV infections of the cervix do not always progress to cancer, 90% of cervical cancer cases have been found to be associated with high risk HPV (HR-HPV) infection. HPV DNA testing is widely used, along with Papanicolaou (Pap) testing, to screen for cervical abnormalities. However, there are no data on the prevalence of genotype-specific HPV infections assessed by measuring HPV E6/E7 mRNA in women representative of the Chinese population across a broad age range. Materials and Methods: In the present study, we compared the results with the CervicGen HPV RT-qDx assay, which detects 16 HR-HPV genotypes (Alpha-9: HPV 16, 31, 33, 35, 52, and 58; Alpha-7: HPV 18, 39, 45, 51, 59, and 68; and Alpha-5, 6: HPV 53, 56, 66, and 69), and the REBA HPV-ID assay, which detects 32 HPV genotypes based on the reverse blot hybridization assay (REBA) for the detection of oncogenic HPV infection according to cytological diagnosis. We also investigated the prevalence and genotype distribution of HPV infection with a total of 324 liquid-based cytology samples collected in western Shandong province, East China. Results: The overall HPV prevalences determined by HPV DNA and HPV E6/E7 mRNA assays in this study were 79.9% (259/324) and 55.6% (180/324), respectively. Although the positivity of HPV E6/E7 mRNA expression was significantly lower than HPV DNA positivity, the HPV E6/E7 mRNA assay showed greater specificity than the HPV DNA assay (88.6% vs. 48.1%) in normal cytology samples. The prevalence of Alpha-9 (HPV 16, 31, 33, 35, 52, and 58) HPV infection among these women accounted for up to 80.3% and 76.1% of the high-grade lesions detected in the HPV mRNA and DNA tests, respectively. The HR-HPV genotype distribution, based on HPV DNA and E6/E7 mRNA expression by age group in patients with cytologically confirmed lesions, was highest in women aged 40 to 49 years (35.9% for cytologically confirmed cases, Pearson correlation r value=0.993, p<0.001) for high-grade lesions. Among the oncogenic HR-HPV genotypes for all age groups, there was little difference in the distribution of HPV genotypes between the HPV DNA (HPV -16, 53, 18, 58, and 33) and HPV E6/E7 mRNA (HPV -16, 53, 33, 58, and 18) assays. HPV 16 was the most common HPV genotype among women with high-grade lesions. Conclusions: Our results suggest that the HPV E6/E7 mRNA assay can be a sensitive and specific tool for the screening and investigation of cervical cancer. Furthermore, it may provide useful information regarding the necessity for early cervical cancer screenings and the development of additional effective HPV vaccines, such as one for HPV 53 and 58. Additionally, gaining knowledge of HPV distribution may also inform us about ecological changes in HPV after the vaccination.

Quantitative Comparisons in $^{18}F$-FDG PET Images: PET/MR VS PET/CT ($^{18}F$-FDG PET 영상의 정량적 비교: PET/MR VS PET/CT)

  • Lee, Moo Seok;Im, Young Hyun;Kim, Jae Hwan;Choe, Gyu O
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.68-80
    • /
    • 2012
  • Purpose : More recently, combined PET/MR scanners have been developed in which the MR data can be used for both anatometabolic image formation and attenuation correction of the PET data. For quantitative PET information, correction of tissue photon attenuation is mandatory. The attenuation map is obtained from the CT scan in the PET/CT. In the case of PET/MR, the attenuation map can be calculated from the MR image. The purpose of this study was to assess the quantitative differences between MR-based and CT-based attenuation corrected PET images. Materials and Methods : Using the uniform cylinder phantom of distilled water which has 199.8 MBq of $^{18}F$-FDG put into the phantom, we studied the effect of MR-based and CT-based attenuation corrected PET images, of the PET-CT using time of flight (TOF) and non-TOF iterative reconstruction. The images were acquired from 60 minutes at 15-minute intervals. Region of interests were drawn over 70% from the center of the image, and the Scanners' analysis software tools calculated both maximum and mean SUV. These data were analyzed by one way-anova test and Bland-Altman analysis. MR images are segmented into three classes(not including bone), and each class is assigned to each region based on the expected average attenuation of each region. For clinical diagnostic purpose, PET/MR and PET/CT images were acquired in 23 patients (Ingenuity TF PET/MR, Gemini TF64). PET/CT scans were performed approximately 33.8 minutes after the beginnig of the PET/MR scans. Region of interests were drawn over 9 regions of interest(lung, liver, spleen, bone), and the Scanners' analysis software tools calculated both maximum and mean SUV. The SUVs from 9 regions of interest in MR-based PET images and in CT-based PET images were compared. These data were analyzed by paired t test and Bland-Altman analysis. Results : In phantom study, MR-based attenuation corrected PET images generally showed slightly lower -0.36~-0.15 SUVs than CT-based attenuation corrected PET images (p<0.05). In clinical study, MR-based attenuation corrected PET images generally showed slightly lower SUVs than CT-based attenuation corrected PET images (excepting left middle lung and transverse Lumbar) (p<0.05). And percent differences were -8.01.79% lower for the PET/MR images than for the PET/CT images. (excepting lung) Based on the Bland-Altman method, the agreement between the two methods was considered good. Conclusion : PET/MR confirms generally lower SUVs than PET/CT. But, there were no difference in the clinical interpretations made by the quantitative comparisons with both type of attenuation map.

  • PDF

The Influence of Iteration and Subset on True X Method in F-18-FPCIT Brain Imaging (F-18-FPCIP 뇌 영상에서 True-X 재구성 기법을 기반으로 했을 때의 Iteration과 Subset의 영향)

  • Choi, Jae-Min;Kim, Kyung-Sik;NamGung, Chang-Kyeong;Nam, Ki-Pyo;Im, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.122-126
    • /
    • 2010
  • Purpose: F-18-FPCIT that shows strong familiarity with DAT located at a neural terminal site offers diagnostic information about DAT density state in the region of the striatum especially Parkinson's disease. In this study, we altered the iteration and subset and measured SUV${\pm}$SD and Contrasts from phantom images which set up to specific iteration and subset. So, we are going to suggest the appropriate range of the iteration and subset. Materials and Methods: This study has been performed with 10 normal volunteers who don't have any history of Parkinson's disease or cerebral disease and Flangeless Esser PET Phantom from Data Spectrum Corporation. $5.3{\pm}0.2$ mCi of F-18-FPCIT was injected to the normal group and PET Phantom was assembled by ACR PET Phantom Instructions and it's actual ratio between hot spheres and background was 2.35 to 1. Brain and Phantom images were acquired after 3 hours from the time of the injection and images were acquired for ten minutes. Basically, SIEMENS Bio graph 40 True-point was used and True-X method was applied for image reconstruction method. The iteration and Subset were set to 2 iterations, 8 subsets, 3 iterations, 16 subsets, 6 iterations, 16 subsets, 8 iterations, 16 subsets and 8 iterations, 21 subsets respectively. To measure SUVs on the brain images, ROIs were drawn on the right Putamen. Also, Coefficient of variance (CV) was calculated to indicate the uniformity at each iteration and subset combinations. On the phantom study, we measured the actual ratio between hot spheres and back ground at each combinations. Same size's ROIs were drawn on the same slide and location. Results: Mean SUVs were 10.60, 12.83, 13.87, 13.98 and 13.5 at each combination. The range of fluctuation by sets were 22.36%, 10.34%, 1.1%, and 4.8% respectively. The range of fluctuation of mean SUV was lowest between 6 iterations 16 subsets and 8 iterations 16 subsets. CV showed 9.07%, 11.46%, 13.56%, 14.91% and 19.47% respectively. This means that the numerical value of the iteration and subset gets higher the image's uniformity gets worse. The range of fluctuation of CV by sets were 2.39, 2.1, 1.35, and 4.56. The range of fluctuation of uniformity was lowest between 6 iterations, 16 subsets and 8 iterations, 16 subsets. In the contrast test, it showed 1.92:1, 2.12:1, 2.10:1, 2.13:1 and 2.11:1 at each iteration and subset combinations. A Setting of 8 iterations and 16 subsets reappeared most close ratio between hot spheres and background. Conclusion: Findings on this study, SUVs and uniformity might be calculated differently caused by variable reconstruction parameters like filter or FWHM. Mean SUV and uniformity showed the lowest range of fluctuation at 6 iterations 16 subsets and 8 iterations 16 subsets. Also, 8 iterations 16 subsets showed the nearest hot sphere to background ratio compared with others. But it can not be concluded that only 6 iterations 16 subsets and 8 iterations 16 subsets can make right images for the clinical diagnosis. There might be more factors that can make better images. For more exact clinical diagnosis through the quantitative analysis of DAT density in the region of striatum we need to secure healthy people's quantitative values.

  • PDF

Prevalence of anatomical alar band (콧방울띠의 유병율)

  • Kim, Jung Suk;Kim, Cheol Soon;Cha, Jung Yul;Kim, Hee Jin;Hwang, Chung Ju
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.4-12
    • /
    • 2015
  • Purpose: Due to the presence of various muscles around lips, variety of facial expression can be made and changes from aging process such as wrinkles can develop on the facial skin by the action of multiple muscles. In animals, skin and muscles are developed in the entire body. On contrast, they are well developed only in the face and just one is present in the neck and the palm. Alar band was defined as outer wrinkle formed by zygomaticus minor muscle, which is common in Koreans. This study aimed to investigate clinical prevalence of alar band. Materials & Methods: Subjects were chosen from 780 new patients who visited private clinic in Gyeonggi province for orthodontic treatment. Presence of alar band was examined from the smile extraoral photos. Correlation among skeletal form, lip protrusion, gender, and age were evaluated. Results: Prevalence of alar band was higher in women (27.9%) than in men (18.5%) with statistical significance (p<0.05). With respect to age, prevalence of alar band was 19.4% in age 0-9 y, 16.9% in age 10-19 y, 31.2% in age 20-29 y, 39.5% in age 30-39, 56.5% in age 40-49. Prevalence was gradually increased from patients in their 20s to patients in their 40s and statistical significance was found (p<0.001). Concerning SN_NP, prevalence was 26.2% in normodivergent facial type, 22.0% in hyperdivergent facial type, and 32.2% in hypodivergent facial type. Hypodivergent facial group had higher prevalence but statistical significance was not observed. Statistically significant difference was not found regarding upper lip. However, prevalence of the alar band was 26% in patients with normal lower lip, 14.7% in patients with pretruded lower lip, and 33.3% in retruded lower lip. The prevalence was higher in patients with retruded lower lip with statistical significance (p<0.05). Conclusions: 27.8% on previous anatomical study and this study showed 27.8% prevalence of alar band in clinical smile photographs. Clinical photograph study showed that alar band was more prominent in women, older people, and people with retruded lips with statistical significance. This will provide valuable diagnostic information for esthetic consideration.

Liver Splitting Using 2 Points for Liver Graft Volumetry (간 이식편의 체적 예측을 위한 2점 이용 간 분리)

  • Seo, Jeong-Joo;Park, Jong-Won
    • The KIPS Transactions:PartB
    • /
    • v.19B no.2
    • /
    • pp.123-126
    • /
    • 2012
  • This paper proposed a method to separate a liver into left and right liver lobes for simple and exact volumetry of the river graft at abdominal MDCT(Multi-Detector Computed Tomography) image before the living donor liver transplantation. A medical team can evaluate an accurate river graft with minimized interaction between the team and a system using this algorithm for ensuring donor's and recipient's safe. On the image of segmented liver, 2 points(PMHV: a point in Middle Hepatic Vein and PPV: a point at the beginning of right branch of Portal Vein) are selected to separate a liver into left and right liver lobes. Middle hepatic vein is automatically segmented using PMHV, and the cutting line is decided on the basis of segmented Middle Hepatic Vein. A liver is separated on connecting the cutting line and PPV. The volume and ratio of the river graft are estimated. The volume estimated using 2 points are compared with a manual volume that diagnostic radiologist processed and estimated and the weight measured during surgery to support proof of exact volume. The mean ${\pm}$ standard deviation of the differences between the actual weights and the estimated volumes was $162.38cm^3{\pm}124.39$ in the case of manual segmentation and $107.69cm^3{\pm}97.24$ in the case of 2 points method. The correlation coefficient between the actual weight and the manually estimated volume is 0.79, and the correlation coefficient between the actual weight and the volume estimated using 2 points is 0.87. After selection the 2 points, the time involved in separation a liver into left and right river lobe and volumetry of them is measured for confirmation that the algorithm can be used on real time during surgery. The mean ${\pm}$ standard deviation of the process time is $57.28sec{\pm}32.81$ per 1 data set ($149.17pages{\pm}55.92$).

A Survey on the Conception and Cognition about Enuresis of Primary Care Physicians in Daegu City (대구 지역 일차 진료를 담당하는 의사의 야뇨증에 대한 인식 평가)

  • Choi, Jung-Youn;Kim, Sae-Yoon;Lee, Kyung-Soo;Park, Yong-Hoon
    • Childhood Kidney Diseases
    • /
    • v.12 no.1
    • /
    • pp.78-87
    • /
    • 2008
  • Purpose: Recently, the conception and cognition that enuresis was resolved spontaneously, have changed. We reviewed the attitudes of the primary care physicians who make diagnose and treat nocturnal enuresis. Methods: From January 2006 to February 2007, a total of 293 primary care physicians in Daegu city participated in this survey. Questionnaires included questions about physicians' opinions on the appropriated age for diagnosis of enuresis, the likely causes of enuresis, etc. Physicians are grouped in two according to whether enuresis is major field of their subspecialty; the pediatrician & urologist group and the other physician group. Results: 59.2% of pediatricians and urologists thought that enuresis is defined as the nightly involuntary release of urine by children of the age of 5 to 6, while 49.6% of other physicians did. For the causes of enuresis, most of clinicians checked "yes" to the question that "Under-developed bladder and nerve" and "Emotional problems". In the patient's behavioral reactions related to enuresis, "Lack of concentration in home and school" and "Frequent urination" were most responded. Attendance to the education program of enuresis in last five years and willing to participate in education program was statistically different among pediatricians-urologists and other physicians. Regarding the treatment of enuresis, most physicians used imiprarnin widely, but pediatricians and urologists preferred desmopressin. Alarm was the last one in treatment modality. Conclusion: This study revealed that pediatricians and urologists are attending more to the educational places and knowing much about the recent information on enuresis when compared to other primary care physicians, regarding the diagnostic age and treatment modality of enuresis. The education of enuresis for primary physicians is more needed.

  • PDF

The Differentiation of Benign from Maligant Soft Tissue Lesions using FDG-PET: Comparison between Semi-quantitative Indices (FDG-PET을 이용한 악성과 양성 연부조직 병변의 감별: 반정량적 지표간의 비교)

  • Choi, Joon-Young;Lee, Kyung-Han;Choe, Yearn-Seong;Choi, Yong;Kim, Sang-Eun;Seo, Jai-Gon;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.90-101
    • /
    • 1997
  • The purpose of this study is to evaluate the diagnostic accuracy of various quantitative indices for the differentiation of benign from malignant primary soft tissue tumors by FDG-PET. A series of 32 patients with a variety of histologically or clinically confirmed benign (20) or malignant (12) soft tissue lesions were evaluated with emission whole body (5min/bed position) PET after injection of [$^{18}F$]FDG. Regional 20min transmission scan for the attenuation correction and calculation of SUV was performed in 16 patients (10 benign, 6malignant) followed by dynamic acquisition for 56min. Postinjection transmission scan for the attenuation correction and calculation of SUV was executed in the other 16 patients (10 benign, 6 malignant). The following indices were obtained. the peak and average SUV (pSUV, aSUV) of lesions, tumor-to-background ratio acquired at images of 51 min p.i. ($TBR_{51}$), tumor-to-background ratio of areas under time-activity curves ($TBR_{area}$) and the ratio between the activities of tumor ROI at 51 min p. i. and at the time which background ROI reaches maximum activity on the time-activity curves ($T_{51}/T_{max}$). The pSUV, aSUV, $TBR_{51}$, and $TBR_{area}$ in malignant lesions were significantly higher than those in benign lesions. We set the cut-off values of pSUV, aSUV, $TBR_{51},\;TBR_{area}$ and $T_{51}/T_{max}$ for the differentiation of benign and malignant lesions at 3.5, 2.8, 5.1, 4.3 and 1.55, respectively. The sensitivity, specificity and accuracy were 91.7%, 80.0%, 84.4% by pSUV and aSUV, 83.3%, 85.0%, 84.4% by $TBR_{51}$, 83.3%, 100%, 93.8% by $TBR_{area}$ and 66.7%, 70.0%, 68.8% by $T_{51}/T_{max}$. The time-activity curves did not give additional information compared to SUV or TBR. The one false negative was a case with low-grade fibrosarcoma and all four false positives were cases with inflammatory change on histology. The visual, analysis of FDG-PET also detected the metastatic lesions in malignant cases with comparable accuracy In conclusion, all pSUV, aSUV, $TBR_{51}$, and $TBR_{area}$ are useful metabolic semi-quantitative indices with good accuracy for the differentiation of benign from malignant soft-tissue lesions.

  • PDF

A Study on the Effective Controlling System of Radio-activity Ventilation (RI사용 의료기관의 효율적인 배기관리 방안)

  • Lee, Kyung-Jae;Lee, Jin-Hyung;Kim, Kyung-Hoon;Kwack, Dong-Woo;Jo, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.

  • PDF

Understanding the Legal Structure of German Human Gene Testing Act (GenDG) (독일 유전자검사법의 규율 구조 이해 - 의료 목적 유전자검사의 문제를 중심으로 -)

  • Kim, Na-Kyoung
    • The Korean Society of Law and Medicine
    • /
    • v.17 no.2
    • /
    • pp.85-124
    • /
    • 2016
  • The Human gene testing act (GenDG) in Germany starts from the characteristic features of gene testing, i.e. dualisting structure consisted of anlaysis on the one side and the interpretation on the other side. The linguistic distincion of 'testing', 'anlaysis' and 'judgment' in the act is a fine example. Another important basis of the regulation is the ideological purpose of the law, that is information autonomy. The normative texts as such and the founding principle are the basis of the classification of testing types. Especially in the case of gene testing for medical purpose is classified into testing for diagnostic purpose and predictive purpose. However, those two types are not always clearly differentiated because the predictive value of testing is common in both types. In the legal regulation of gene testing it is therefore important to manage the uncertainty and subjectivity which are inherent in the gene-analysis and the judgment. In GenDG the system ensuring the quality of analysis is set up and GEKO(Commity for gene tisting) based on the section 23 of GenDG concretes the criterium of validity through guidelines. It is also very important in the case of gene testing for medical purpose to set up the system for ensurement of procedural rationality of the interpretation. The interpretation of the results of analysis has a wide spectrum because of the consistent development of technology on the one side and different understandings of different subjects who performs gene testings. Therefore the process should include the communication process for patients in oder that he or she could understand the meaning of gene testing and make plans of life. In GenDG the process of genetic counselling and GEKO concretes the regulation very precisely. The regulation as such in GenDG seems to be very suggestive to Korean legal polic concerning the gene testing.

  • PDF

A Study of the Pattern of Skeletal Metastases and Renal Uptakes on Bone Scan in Renal Cell Carcinoma (골스캔상 신세포암의 골전이 양상과 신장섭취 형태에 관한 연구)

  • Chun, Hae-Kyung;Yang, Seoung-Oh;Shin, Joung-Woo;Won, Kyoung-Sook;Choi, Yun-Young;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.524-531
    • /
    • 1996
  • Purpose : To evaluate the pattern- of skeletal metastases and to classify the pattern of renal uptakes on bone scans in renal cell carcinoma. Materials and Methods : We reviewed the bone scans of 158 patients with RCC established pathologically. In order to identify individual scan lesion as a bone metastasis, we reviewed all available correlative radiological studies, follow-up bone scans, and biopsies for each lesion. The metastatic bone lesions were divided into seven anatomic regions; skull, spine, shoulder girdle, sternum, ribs, pelvis, and long bones of extremities. The individual scan lesions were divided into two groups as the pattern of uptakes, hot and cold lesion. In addition, the contours and uptakes of kidneys with RCC were classified into 6 groups ; normal uptake, photon-deficient lesion, faint up-take with enlargement, uneven uptake with enlargement, lateralization with crescentic shape, and increased uptake. Results : Twenty out of 158(12.7%) patients with RCC at varying stages showed 71 metastatic bone lesions at presentation and on follow- up bone scans. Nearly 80% of all metastatic lesions were in the axial skeleton with predominantly increased uptake of the radioactivity However a considerable number(22.5%) showed cold lesions on bone scan. A half of bone scans revealed abnormal uptake of involved kidney and much more(82.4%) in case of bone metastases. Two common patterns of abnormal renal uptake were photon-deficient lesion (50%) and faint uptake with enlargement(24.3%). In four patients with bone pain or pathologic fracture, bone scans were useful for the serendipitious localization of previously unrecognized primary lesion of RCC as well as for the detection of bone metastases from RCC. Conclusion : The understanding of the pat-terns of skeletal metastases and renal uptakes on bone scans in RCC is important for the useful information about primary lesion(RCC) as well as detection of bone metastases.

  • PDF