• Title/Summary/Keyword: Diagnostic Information

Search Result 1,412, Processing Time 0.033 seconds

Gadoteridol's Signal Change according to TR, TE Parameters in T1 Image (T1영상에서 TR, TE 매개변수에 따른 Gadoteridol의 신호강도 변화)

  • Jeong, Hyun Keun;Jeong, Hyun Do;Nam, Ki Chang;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.9
    • /
    • pp.117-124
    • /
    • 2015
  • In this paper, we introduce how to control TR, TE physical MR parameters for managing $H_1$ spin's SI(Signal Intensity) which is combined with gadolinium following administration MR agent in T1 effect for diagnostic usefulness. we used MRI phantom made with 0.5 mol Gadoteridol. This phantom was scanned by FSE sequence with different TR, TE parameters. In this study, to make T1 effect, TR was 200, 250, 300, 350, 400, 450, 500, 550, 600 msec. In addition to, TE was 6.2, 12.4, 18.6, 21.6 msec. The results were as follows ; Each RSP(Reaction Starting Point) was 100, 50, 40, 30 mmol in TE 6.2, 12.4, 18.6, 21.6 msec being irrelevant to TR. In MPSI(Max Peak Signal Intensity), 4 mmol was showed in TR 200 msec while peak signal was decreased to low concentration mol in TR 250-600 msec. In terms of RA(Reaction Area), the highest SI was TE 6.2 msec in TR 200-600msec. According to the study, we are able to recognize it is possible to control enhance rates by managing TR and TE of MR parameters; moreover, we expect that enhanced T1 image in MR clinical field can be performed in a practical way with this quantitative data.

The Study of Technical Error Analysis on BMD Using DEXA (이중 에너지 X선 흡수 계측법을 이용한 BMD 검사 시 발생할 수 있는 기술적인 오류 분석)

  • Kang, Yeong-Han;Jo, Gwang-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.229-236
    • /
    • 2006
  • Purpose: This study was conducted to search for the type of technical error in DEXA(dual-energy X-ray absorptiometry) and the effect of error to measurement of BMD. Materials and Methods: The changes of BMD($g/cm^2$, T-score) by patients information(Age, Weight, Height, Manopause age) input error and Confirming ROI error were investigated. Using spine phantom, we canned 10 times by age(5, 10), weight(10, 20 kg), height(5, 10 cm), manopause age(5, 10) increase & decrease respectively. Scanning region(L-spine, femur, Forearm) of 10 patients was calculated by changing ROI respectively. Analysis of difference for mean(precision 1%) were carried out. Results: The error of patient information(Age, Weight, Height, Manopause age) was not changed differently. In confirming ROI, the BMD and T-score of L-spine involving T-12 was decreased to $0.063\;g/cm^2$, 0.3 and involving L-5 increased to $0.077\;g/cm^2$, 0.5. In narrowing 1 cm of vertical line of ROI, the BMD and T-score decreased to $0.006\;g/cm^2$, 0.1 and in 2 cm, $0.021\;g/cm^2$, 0.15, each. In hip ROI, Upper and left shift(0.5 cm) of line was not influenced BMD and T-score. In 0.5 cm lower shift(lesser trochanter below), the BMD and T-score increased $0.031\;g/cm^2$, 0.3 and in 1 cm $0.094\;g/cm^2$, 0.65, each. In forearm ROI, the BMD and T-score decreased $0.042\;g/cm^2$, 0.9 involving 1 cm lower wrist. And expanding 1 cm of vertical line, the BMD and T-score decreased $0.008\;g/cm^2$, 0.1 and in 2 cm, $0.021\;g/cm^2$, 0.3, each. The L-spine, hip, forearm ROI error was changed differently. Conclusion: There are so many kinds of technical error in BMD processing. Errors according to age, weight, height, manopause age did not influent to $BMD(g/cm^2)$ and T-score. There are mean differences BMD and T-score in confirming ROI. For the precision exam, in L-spine processing, L1-4 have to confirmed without shift of ROI vertical line. In hip processing, the ROI have to included greater trochanter, femur head and lesser trochanter. In forearm processing, the ROI have to included wrist, radius and ulnar.

  • PDF

Evaluation of Usefulness of Radio-iodine SPECT/CT in Differentiated Thyroid Cancer (분화성갑상선암에서 방사성요오드 SPECT/CT의 유용성 평가)

  • Lee, Jeong-Won;Lee, Ho-Young;Oh, So-Won;Kim, Seok-Ki;Jeong, Ki-Wook;Kim, Seon-Wook;Kang, Keon-Wook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.5
    • /
    • pp.350-358
    • /
    • 2007
  • Purpose: Localizing and differentiating a metastatic lesion of differentiated thyroid cancer (DTC) by using radio iodine whole body scan could be difficult because a whole body scan (WBS) lacks anatomic information. This study was performed to evaluate the usefulness of radio-iodine SPECT/CT for differentiating equivocal lesions. Materials & Methods: Among 253 patients with DTC who had undergone radio-iodine scan between February and July 2006, 26 patients were enrolled (M:F = 8:18, Age $50.7{\pm}12.5$ years) in this study. The patients had abnormal uptakes in the WBSs that necessitated precise anatomical localization for differentiating between a metastatic lesion and a false-positive lesion. SPECT/CT was performed for the region with abnormal uptake in the WBS. WBS and SPECT/CT were evaluated visually. Metastases were diagnosed based on the results of the radio-iodine scan along with the results of other radiological examinations and serological tests. Results: Based on the WBS images, 13 were suspected with cervical lymph node (LN) metastases in 16 patients with abnormal neck uptake, and in the 11 patients with abnormal extra-cervical uptakes, extra-cervical metastases were doubtful in all. After SPECT/CT was performed, the diagnostic results were altered for 16 patients (62%). SPECT/CT revealed that only 5 patients had cervical LN metastases, while 3 patients had extra-cervical (mediastinal) LN metastases. Overall, there was a 58% (15/26) change in diagnoses and plans for treatment due to SPECT/CT. Among 8 patients suspected with metastases on SPECT/CT, 6 patients underwent another radio-iodine therapy. In 96% (24/25) of the patients, the results of SPECT/CT corresponded with those of further radiological examinations and with other clinical information. Conclusion: Radio-iodine SPECT/CT images permitted the differentiation of abnormal radio-iodine uptake and improved anatomical interpretation in DTC.

Characteristics of Biological Agent and relavent case study (생물무기 특성과 사례연구)

  • Park, Minwoo;Kim, Hwami;Choi, Yeonhwa;Kim, Jusim
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.442-454
    • /
    • 2017
  • Biological weapon is manipulated and produced from microorganisms such as bacteria, virus, rickettsia, fungi etc. It is classified as one of the Weapons of Mass Destruction (WMD) along with chemical weapon and radiological weapon. Biological weapon has a number of operational advantages over the other WMDs including ease of development and production, low cost and possibility of covert dissemination. In this study we analyze the history of biological weapon's development and the existing biological threats. Then, we predict the social impact of biological attack based on the physical properties of biological agent and infection mechanisms. By analyzing the recognition, dispersion pattern of agents, characteristics of the diseases in the biological weapon related historical events such as Sverdlovsk anthrax accident, 2001 anthrax attack, we found out some of the facts that biological attack would not likely to be recognized rapidly, produce large number of the exposed, increase number of paients who suffed from severe respiratory illness. It would lead the public health and medical service providers to be struggled with hugh burden. Base on the facts that we found from this case study, we suggested the main capabilities of public health required to respond to bioterrorism event efficiently. Syndromic surveillance and other reporting system need to be operated effeciently so that any suspicious event should be detected promptly. the pathogen which suspected to be used should be identified through laboratory diagnostic system. It is critical for the public health agency to define potentially exposed population under close cooperation with law enforcement agencies. Lastly, massive prophylaxis should be provided rapidly to the people at need by operating human and material resources effeciently. If those capacities of public health are consistantly fortified we would be able to deal with threat of bioterrorism successfully.

Application of Weed Species as the Diagnostic Indicator Plants of Environmental Pollution (환경오염(環境汚染) 진단(診斷) 지표식물(指標植物)로서 잡초종(雜草種)의 활용(活用)에 관(關)한 연구(硏究))

  • Kang, Byeung-Hoa;Shim, Sang-In;Lee, Sang-Gak
    • Korean Journal of Environmental Agriculture
    • /
    • v.15 no.1
    • /
    • pp.46-69
    • /
    • 1996
  • The studies were conducted to obtain the basic information of the effects of pollutants on plant species and to select the plant species showing specific responses to the pollutants. For these purposes, paraquat, ammonium, and cadmium as a source of oxidative stress, nitrogen toxicity, and heavy metal toxicity respectively were treated to the plant species. Among the tested plants, Lamiaceae, Brassicaceae, and Caryophyllaceae were tolerant to paraquat, whereas Poaceae and Asteraceae were sensitive. Especially Mosla dianthera of Lamiaceae, Hemistepta lyrata and Aster pilosus of Asteraceae, and Paspalum thunbergii of Poaceae showed higher tolerance than others. Paraquat resistance was related with life style, overwintering capacity, so perennial and biennial species showed higher tolerance than annual species. In response to ammonium, Poaceae showed higher resistance while Fabaceae and Caryophyllaceae showed sensitiveness. Weed species having tolerance to ammonium were Echinochloa crus-galli var. praticola, Panicum dichotomiflorum, Setaria glauca, Chenopodium album, and Solanum nigrum, while Mosla dianthera, Arenaria serpyllifolia and Perilla frutescens var. japonica showed sensitiveness. In the response of plant species to cadmium, Digitaria sanguinalis, Amaranthus lividus showed higher resistance, whereas Galinsoga parviflora, Plantago asiatica, Ambrosia trifida, and Paspalum thunbergii showed sensitiveness. The injured degree on germination stage by pollutants did not related with injured degree on matured stage. During germination, the root elongation was more sensitive than shoot elongation by pollutants, paraquat, ammonium, and cadmium.

  • PDF

Micrographic Comparison of Proglottids and Ova in Some Tapeworms(Family: Diphyllobothridae) from Man (인체기생 열두조충류의 형태비교 및 진단적 소견)

  • 류장근;양용상;강성구;백승한;임신영
    • Biomedical Science Letters
    • /
    • v.4 no.1
    • /
    • pp.65-72
    • /
    • 1998
  • Recently there have been frequent reports on human infection caused by the Diphyllobothridae in Korea. The adequate opportunities for Koreans to eat raw fish, the primary infection medium of cestodes and the human infection through drinking water by cyclops, the first intermediate host are believed to be main reasons for the infection. The first task of this study was to classify and diagnose the species by differentiating morphological characteristic between scolex and proglottids of cestodes. However, the initially available diagnosis was done with the patient's symptoms and the eggs obtained from his stool. It is important to differentiate the species by the eggs of Diphyllobothrium latum especially in that it can help get advance information for a more reliable analysis in the near future. The morphological and diagnostic results from proglottids and eggs of Diphyllobothrium latum, Diphyllobothrium latum parvum and Spirometra erinacei are as follows; In each kind of cestodes from the patient's stool, the shape and size of 50 eggs were measured. Eggs of Diphyllobothrium latum had an operculum and were ovoidal or ellipsoid to elliptical in shape. Eggs of Diphyllobothrium latum parvum were more ovoidal in shape and smaller in size than Diphyllobothrium latum. And eggs of Spirometra erinacei were asymmetrical in width and long and slender in shape. The average lengths and widths of Diphyllobothrium latum, Diphyllobothrium latum parvum and Spirometra erinacei were 61.4$\times$41.7 $\mu\textrm{m}$, 55.9$\times$41.4 $\mu\textrm{m}$ and 66.7$\times$36.4 $\mu\textrm{m}$, respectively. After the segments of each cestode were fixed, embedding and hematoxylin-eosin dyeing on a microtome-made specimen were done. The micrographs of the semicon's aceto-carmine dyed specimen showed that Diphyllobothrium latum and Diphyllobothrium latum parvum had a centrally-located genital gland and an opened uterine pore. The yolks were observed on both sides of proglottids and had a typical rosette pattern. Yet, Diphyllobothrium latum parvum was shown smaller than Diphyllobothrium latum in the micrograph. Proglottids of Spirometra erinacei displayed that the uterus was rolled spirally more than five to seven times, and connected successively to the seminal vesicle in the cirrus sac. Shown above, this study was performed to measure the size of eggs and analyze the morphological characteristics of proglottids and provided the measurements of three types of cestodes obtained by a light microscope.

  • PDF

Impacts of Two Types of El Niño on Hydrologic Variability in Annual Maximum Flow and Low Flow in the Han River Basin (두 가지 El Niño 형태에 따른 한강 유역의 연최대홍수량 및 저유량의 변화 분석)

  • Kim, Jong-Suk;Yoon, Sun-Kwon;Lee, Joo-Heon
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.10
    • /
    • pp.969-981
    • /
    • 2012
  • In this study, we analysed hydrologic variability in quantity and onset of annual maximum flow and low flow by impacts of the different phases of ENSO (El Ni$\tilde{n}$o Southern Oscillation) over the Han River Basin. The results show that annual maximum flow has increased statistically significant about 48.3% of all over the watershed. The onset of annual maximum flow was delayed in the west of the Han River basins and in the east of the basins was likely to be rapid onset. Also, this study shows that 7-day low flow was deceased statistically significant about 26.0% of the total area in the Han River Basin, and onset of 7-day low flow tends to be faster in the upper-middle basins of the Han River. The onset of annual maximum flow shows similar pattern during the CT (Cold tongue)/WP (Warm-pool) El Ni$\tilde{n}$o years, but annual maximum flow appeared less in 89.0% of all basins during the CT El Ni$\tilde{n}$o years. In addition, the onset of 7-day low flow tended to be faster about 17 days on average during the WP El Ni$\tilde{n}$o years, and 72.7% of the basins show significant increase during the CT El Ni$\tilde{n}$o years. Consequently, it was found that the different phases of CT/WP El Ni$\tilde{n}$o have effects on sensitivity to variability in quantity and onset of water resources over the Han River Basin. We expect that the present diagnostic study on hydrological variability during different phases of ENSO will provide useful information for long-term prediction and water resources management.

Usefulness about BSGI (Breast Specific Gamma Imaging) in Breast Cancer Patients (유방암 환자에서 Breast Specific Gamma Imaging (BSGI)의 유용성)

  • Cho, Yong-Gwi;Pyo, Seong-Jae;Kim, Bong-Su;Shin, Chea-Ho;Cho, Jin-Woo;Yeo, Ji-Yeon;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.92-101
    • /
    • 2009
  • Purpose: Scintimammography is one of the screening tests for the early diagnosis of breast cancer. It has been widely accepted as very useful in assessing masses that have not been detected in breast scanning. This method is highly sensitive and specific with respect to the diagnosis of primary and relapsing breast cancer. It has some difficulties, however, in detecting tumors sized 1 cm and below due to the radioactivity around the breast and the geometrical structure of the equipment. The recent introduction of high-resolution Breast-specific Gamma Imaging (BSGI) has made it possible to more accurately discriminate between malignant and benign tumors than with any other test method. Thus, the possibility of an unnecessary biopsy being performed has decreased. The purpose of this study was to examine the diagnostic capacity of mammography, breast sonography, and scintimammography, which are used for the early diagnosis of known breast cancer, and of BSGI, and to evaluate the skillfulness of radiologists. Materials and Methods: The 53 volunteers participants who had no clinical manifestation of breast cancer underwent the BSGI in February 2009. In the BSGI procedure, scanning images were obtained from the craniocaudal projection (CC) and the mediolateral Oblique projection (MLO), as well as from the additional $80{\times}80$-matrix-sized views at various angles in the Present Time method, 10 minutes after the 25 mCi $^{99m}Tc$-MIBI was injected. Results: The results of the BSGI showed that two participants had masses in their breast tissue. As the results of the diagnosis of four participants were not clear, they were retested and the results of the second test were negative. The results of the clinical screening test for breast cancer showed that the sensitivity of BSGI, scintimammography, mammography, and breast sonography was 86.5%, 77.8%, 85~90%, and 66.7%, respectively, and that their specificity was 92.4%, 84.2%, 20~42%, and 68%, respectively. Conclusion: The autodiagnosis and breast cancer screening test are needed for the early diagnosis of breast cancer. It was not easy, however, to accurately determine the presence of a mass in the breast using the existing breast cancer screening test. The patients with unclear test findings were made to undergo a histologic biopsy for a more accurate diagnosis. It is expected that the BSGI can provide useful information for the early diagnosis of breast cancer and of primary breast cancer, and will reduce the performance of unnecessary biopsies because of its higher sensitivity and specificity than existing breast cancer screening tests.

  • PDF

Need Assessment of Home-based Cancer Patients (재가암환자 요구도 조사)

  • Kim, Tae-Sook;Yang, Byung-Guk;Jeong, Eun-Kyeong;Park, No-Rai;Lee, Young-Sook;Lee, Young-Sung;Lee, Sok-Goo;Kim, Young-Taek;Yun, Young-Ho;Huh, Gil-Ja
    • Journal of Hospice and Palliative Care
    • /
    • v.2 no.1
    • /
    • pp.36-45
    • /
    • 1999
  • Purpose : Cancer, one of the major causes of death in Korea, tends to become chronic due to the rapid development of diagnostic and therapeutic methods. As a result, the number of home-based cancer patients is in the increasing trend. However, on account of the insufficiency of continuous and comprehensive cancer patient management system, a number of cancer patients are left in a defenseless state. This study was designed for need assessment of home-based cancer patient to establish the community-based health care system for the comprehensive and continuous health care service to improve the quality of life of cancer patients and reduce rare burdens of their families. Methods : Through making a survey for needs assessment toward the health care service, the 455 respondents among home-based cancer patients answered the given enquetes to analyze the management status and problems of home-based cancer patients Results : 1) Unsatisfaction rates of pain control is 25.5 percent for mild cases, 46.5 percent for severe cases. 2) According to the needs assessment of home-based cancer patients, most of the respondents want to receive economical support, alleviation for the pain and symptoms, and the information of health care and consultation. So these needs account for the main contents of the home-based cancer patient management plan. 3) In the aspect of the satisfaction rate for basic care need, most items account for $20{\sim}30%$ of satisfaction. And the proportion of need for special case is under 5%, satisfaction rate for special care need is about 50% of satisfaction. So the home-based cancer patients are not being cared sufficiently. Conclusion : According to the result of need assessment, many home-based cancer patients received inadequate pain and symptom management. And Satisfaction rate for basic and special care need is low. So development of comprehensive and continuous health care service to improve the quality of life of cancer patients and reduce care burdens of their families is very necessary.

  • PDF

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF