• Title/Summary/Keyword: Diagnose

Search Result 2,899, Processing Time 0.029 seconds

Analysis on Characteristics of Core and Winding Vibration in Cast Resin Transformer (몰드변압기 철심과 권선 진동 특성분석)

  • Kim, Chong-Min;Choi, Myung-Il;Kim, Young-Seog;Bang, Sun-Bae;Shong, Kil-Mok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.52-59
    • /
    • 2012
  • In this paper, The cast resin transformer's vibration is measured using noncontact raser vibrometer(LV110D). The vibration characteristics of transformer windings and core are analyzed for relation between vibration magnitude and cause. Using the analysis results, the technique is presented to diagnose cast resin transformer. which is able to diagnose transformer' deformation in winding and core geometry. The magnetostriction and electromagnetic force act on the core and windings, causing them to vibrate. The vibration from windings and core penetrates into transformer cast resin and reaches the outside walls. The fundamental frequency of the core and windings vibration signal is twice that of the power frequency(120Hz). The results show that the magnitude of core vibration is linear to driving voltage amplitude and magnitude of windings vibration is increased to loading current under the some level and then stabilized.

A Study on the Technology to Diagnose GIS with Acoustic Emission by Dropping Particles Method (이물 낙하법에 의한 GIS 초음파 진단 기술 연구)

  • Kim, Gwang-Hwa;Choe, Jae-Gu;Seon, Jong-Ho;Kim, Ik-Su;Yun, Jin-Yeol;Park, Gi-Jun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.6
    • /
    • pp.246-252
    • /
    • 2002
  • This paper describes the acoustic emission measurement method to diagnose GIS for particles. We measured and analyzed the signals of acoustic waves using acoustic two types sensors with 125KHz and 50KHz resonant frequency respectively when the particles were dropped on the surfaces of circular plates and inside of GlS tanks. We found that the difference between peak outputs of two sensors depended on the types and materials of particles and the conditions of dropping position. These results showed that the outputs of 125KHz sensor were higher than those of 50KHz sensor in circular plate and 362㎸ GIS tank made of steel and vice versa in circular plate and 800㎸ GIS tank made of aluminum. The ratios outputs of 125KHz sensor to those of 50KHz sensor were 1.4 - 2.37 in 800㎸ GIS tank and were 0.5 - 1.0 in 362㎸ GIS tank. Therefore we knew that adaption of two types acoustic sensors which had different resonant frequencies as a very useful method in diagnosis of GIS.

The Impacts of Photoperiods on Hypothalamic Proteins in the Reproductive Activities of Golden Hamsters

  • Choi, Don-Chan;Han, Eun-Hee
    • Development and Reproduction
    • /
    • v.14 no.3
    • /
    • pp.185-197
    • /
    • 2010
  • The reproduction of animals is a means to maintain their species. The golden hamsters are seasonal breeders, and their reproduction is regulated by the photoperiod. The shifts of the sexual functions imply the changes of the protein expression, and those are reflected by the proteome. Thus the present study was to examine via two dimensional polyacrylamide gel electrophoresis (2d PAGE), the physiological changes and the alterations of protein expressions in hypothalamus upon the reproductive situation related to the pineal gland. Among the pineal intact animals, the reproductive functions were sustained in animals housed in long photoperiod (LP) but regressed in animals housed in short photoperiod. And those pinealectomized animals showed high sexual activities regardless of photoperiod. Ultimately they were branched into dichotomy, sexually active and inactive animals. Apart from the changes of physiological parameters upon the reproductive conditions, there were obvious differences in proteins extracted from the hypothalamus. The hypothalamus of LP animals presented high levels of enzymes which are involved in the production of energy, glycolysis and Krebs cycle. The increased energy might be related to the GnRH synthesis in hypothalamus and indirectly to the constant cell divisions in spermatogenesis. Taken together, the impacts of the photoperiodic information controlling reproduction could be observed through 2d PAGE. Therefore, the present results suggest the potential of biomarkers collectively to diagnose the fertility and the infertility by way of proteomics in organs with regard to the reproductive system, further could be applied to diagnose various diseases.

Fault prediction of wind turbine and Generation benefit evaluation by using the SVM method (SVM방법을 이용한 풍력발전기 고장 예측 및 발전수익 평가)

  • Shin, Jun-Hyun;Lee, Yun-Seong;Kim, Sung-Yul;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.60-67
    • /
    • 2014
  • Wind power is one of the fastest growing renewable energy sources. The blades length and tower height of wind turbine have been growing steadily in the last 10 years in order to increase the output amount of wind power energy. The amount of wind turbine energy is increased by increasing the capacity of wind turbine, but the costs of preventive, corrective and replacement maintenance are also increased accordingly. Recently, Condition Monitoring System that can repair the fault diagnose and repair of wind turbine in the real-time. However, these system have a problem that cannot predict and diagnose of the fault. In this paper, wind turbine predict methodology is proposed by using the SVM method. In the case study, correlation analysis between wind turbine fault and external environmental factors is performed by using the SVM method.

Design of radiation detection circuit for gamma column scanning (자동 감마 증류탑 검사 장치를 위한 방사선 계측장치 설계)

  • Kim, Jong-Beom;Jeong, Seong-Hui
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.612-615
    • /
    • 2003
  • In this paper, a design of radiation detector for gamma column scanner is introduced. Distillation column is important unit in Petro-chemical industries, and its on-line diagnose is very important. To get density profile measured by the radiation transmitted through column is well method for on-line diagnose as gamma scanning. For this purpose radiation detection circuit, radiation source and mechanical system for moving source and detector are required. Conventional radiation detection circuit for this application is sensitive to electric noise because of interface between the radiation circuit and the controller for mechanical system. The radiation detection system introduced here is using loop coil instead of slip ring to remove contact noise. Radiation detection system designed here for gamma scanning consist of BGO detector, high voltage circuit, PHA circuit and FSK modem. The BGO detector is used as radiation sensor, high voltage circuit and peak height analysis circuit is essential to process the signal generated from BGO detector. Micro controller convert measured data into ASCII data. FSK modem transmit ASCII data. Transmitted ASCH data is picked up in antenna coil and processed for combined function with mechanical system. This method gives good result by isolating the controlling circuit of mechanical system from radiation detecting circuit which is sensitive to noise.

  • PDF

Development of a Self-Diagnostic Measurement Index for ISO 26000 Social Responsibility

  • Lee, Myung-Goo;Cho, Han-Jin
    • Land and Housing Review
    • /
    • v.2 no.4
    • /
    • pp.325-344
    • /
    • 2011
  • On November 1, 2010, the release of ISO 26000 was announced. ISO 26000 does not require 3rd party verification. But even though it is a standard that is voluntarily adopted, because the international standard for social responsibility can be applied as a trade barrier or business condition between countries, it cannot be ignored. So it is clear that we need to be alerted and prepared for this. This paper offers to help with such needs through organizations by developing an index that organizations can use to understand their current situation and diagnose themselves. This paper conducts a comparative analysis between the 7 core subjects and issues of ISO 26000, the existing indexes used by national institutions and the guideline for sustainable management report, the GRI, with the goal of developing a self-diagnostic index that organizations can utilize in order to diagnose their level of social responsibility. It is divided into the 7 core subjects with 181 measurement issues. There are 7 quantitative issues and 164 qualitative issues. The core subjects, excluding governance, are each alloted 14 points, while governance is alloted with 16 points, for a total score of 100 points. This paper is significant in that it is the first index to make self-diagnostic possible.

A Study on the Design and Measurement of a Balancing Device for Unbalance Correction of Differential Gear Case in Automobile (자동차 Differential gear case 불평형 교정을 위한 balancing 장치설계 및 측정에 관한 연구)

  • Jang, T.H.;Gwon, J.U.;Eum, J.H.;Kim, J.A.;Kim, T.G.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.33 no.6
    • /
    • pp.303-309
    • /
    • 2020
  • A vehicle's differential gear is a device designed to allow the vehicle's outer wheels to turn faster than the inner wheels when turning on a curve. The differential gear case is the main component of the differential gear system, which is composed of ring gear, pinion gear and side gear, and is fastened by pinion shaft pins. The differential gear case rotates when the vehicle is running, so balancing calibration is very important. In this study, a balancing machine that can diagnose and correct the differential gear case and mass imbalance of various rotating bodies was designed. The differential gear case was rotated at high speed to accurately diagnose the location and value of the unbalanced mass, and it was designed to be balanced and corrected by removing the unbalanced mass by drilling. After calibration, it was confirmed that the unbalanced value of all the measured samples was reduced to less than 180g.mm, and the unbalance reduction ratio was improved to 60~70%.

Anomaly Diagnosis of Rotational Machinery Using Time-Series Vibration Data Based on Time-Distributed CNN-LSTM (시분할 CNN-LSTM 기반의 시계열 진동 데이터를 이용한 회전체 기계 설비의 이상 진단)

  • Kim, Min-Ki
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.11
    • /
    • pp.1547-1556
    • /
    • 2022
  • As mechanical facilities are interacting with each other, the failure of some equipment can affect the entire system, so it is necessary to quickly detect and diagnose the abnormality of mechanical equipment. This study proposes a deep learning model that can effectively diagnose abnormalities in rotating machinery and equipment. CNN is widely used for feature extraction and LSTMs are known to be effective in learning sequential information. In LSTM, the number of parameters and learning time increase as the length of input data increases. In this study, we propose a method of segmenting an input segment signal into shorter-length sub-segment signals, sequentially inputting them to CNN through a time-distributed method for extracting features, and inputting them into LSTM. A failure diagnosis test was performed using the vibration data collected from the motor for ventilation equipment installed at the urban railway station. The experiment showed an accuracy of 99.784% in fault diagnosis. It shows that the proposed method is effective in the fault diagnosis of rotating machinery and equipment.

Inter- and Intra- Rater Reliability of Navicular Drop Tests Position

  • Kim, So-yeon;Yoo, Jung-eun;Woo, Da-hyun;Jung, Bo-young;Choi, Bo-ram
    • Journal of Korean Physical Therapy Science
    • /
    • v.26 no.1
    • /
    • pp.9-14
    • /
    • 2019
  • Background: Pes planus, or flat foot, causes lower limb malalignment and foot pain during walking or exercise. Therefore, a highly reliable evaluation method to accurately diagnose flat feet is necessary. This study investigated the intra-and inter-rater reliability of the navicular drop test in different postures. Design: Cross sectional study. Methods: Forty healthy volunteers performed the navicular drop test in three different combinations of non-weight-bearing and weight-bearing postures (standing/standing, sitting/sitting, and sitting/standing). Two examiners alternately performed the measurements five times in each subject, and in each posture. Significant differences in measurements were obtained among the three postures, with the highest navicular drop being observed in the sitting/standing posture. Results: Inter-rater reliability was high in the sitting/standing and sitting/sitting postures. Intra-rater reliability was high in all three postures. In the sitting/sitting and sitting/standing postures, large navicular drop values and high inter- and intra-rater reliability were observed. Conclusion: Therefore, the sitting/standing and sitting/sitting postures are recommended for use in navicular drop tests to diagnose flat feet.

Development of diagnosis index for tick/click and tone noise of blower motor using vibration signals (진동 신호를 이용한 블로워 모터 틱/클릭과 톤 소음의 진단 지수 개발)

  • Lee, Songjune;Cheong, Cheolung;Lee, In-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.3
    • /
    • pp.363-369
    • /
    • 2019
  • Various studies have been conducted for the diagnosis of noise condition of complex rotary machines. In this study, diagnosis index using vibration signal is developed for the efficient and objective assessment of noise condition of a blower motor. The noise most commonly caused by the abnormal blower motor are Tick/Click noise and Tone noise. According to cause and noise characteristics, time-frequency analysis is used to diagnose Tick/Click noise, and smoothing in frequency domain is used to diagnose tone noise condition. The noise condition of the blower motors were diagnosed using the developed index and these results are compared with the diagnostic results by the experts. As a result, the agreement rate was about 95 %.