• 제목/요약/키워드: Diagnistic

검색결과 3건 처리시간 0.017초

다중결함에 의한 부분방전 패턴특성 (PD Characteristics of Multi-Defects System)

  • 이준호;이철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2411-2413
    • /
    • 1999
  • Regarding the application of diagnistic technology using PD signal to power apparatus, it is necessary to discriminate the type of defect as well as to determine whether the PD occurs or not. In this research, PD characteristics of multi-defects insulating system were presented, the PD signals were detected from three kinds of electrode systems, IEC(b), needle-plane and CIGRE method II. To make multi-defect systems artificially, we combined three electrode systems and applied same test voltage simultaneously.

  • PDF

입력전원의 변화에 따른 X선 기기의 특성평가 (Characteristic of X-ray Equipment according to the Input Power Condition)

  • 김영표;김태곤;천민우;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.773-775
    • /
    • 2010
  • 의료용 X-선 고전압발생장치는 작동 시 높은 용량의 입력전원이 필요하며, 만약 전원환경이 적합하지 않을 경우 X-선 고전압발생장치를 사용하지 못하거나 불안정한 작동으로 인해 원활한 작동이 불가능해 진다. 전원환경에 따라 제품이 불안정 할 경우 환자 진료에 지장이 생길 수 있는 것을 감안하여 상용전원을 사용하지 않고 의료용 X-선 고전압발생장치를 작동 할 수 있는 전원장치를 배터리를 활용하도록 하였다. 전원회로를 설계한 후 시제품을 제작하여 본 논문에 제시된 방법에 따라 상용전원과 배터리 전원을 각각 비교하여 의료용 X-선 고전압발생장치가 입력전원방식에 따라 어떤 특성과 효율을 가지고 있는지 확인하였다.

  • PDF

Non Breathe Hold Technique를 이용한 MR 담도계조영술에 대한 고찰 : Prospective Acquisition Correction(PACE)기법과 Respiration Trigger Gating(RTG) 기법의 비교 (A Study on MR Cholangiography using Breathing Hold Target Techniqu by Prospective Acquisition Correction and Respiration Trigger Gating)

  • 구은희;정홍량;임청환;권대철;조정근;이만구
    • 대한디지털의료영상학회논문지
    • /
    • 제10권1호
    • /
    • pp.45-50
    • /
    • 2008
  • Recently, MR Cholangiography used mainly bu controlling of patient's breathing. There is breathing hold techniques to get images within shopt time and gating technique adjusted to respiration cycle for high resolution image. In this study, the aim of this experiment is to know on clinical usefulness compared with PACE and RTG thchniques. This study's period is from 2006 in November to 2007 in January. A total of 21 patients investigated at MAGNETOM Sonata 1.5T (SIEMENS Erlangen) with use of 12ch body coil. MR acquisition protocol used 3D turbo spin echo coronal sequence. Scan parameters applied to potimal setting in use as gating techniques, respectively. Analysis of consuming timing evaluated with rapidness. As analysis of quantity, the common bile duct, gall bladder measured in signal intensities, then these data were calculated by signal to noise ratio and contrast to noise ratio. Qualitative analysis, experienced 2radiologists and 3 RTs were evaluated into 3groups about artifact, accuracy of lesions, sharpness of the common bile duct or gall bladder. As a result of analysis, when compared to PACE, consuming time of the RTG took less than PACE, On both CNRs and SNRs, PACE technique was slightly high values than RTG(p<0.05). Qualitative analysis' results, discrimination of lesions in the common bile duct, gall bladder get a significance level in both RTG and PACE techniques but presence's artifact of breathing and pulsation highly demonstrate in PACE techniques. In conclusion, both PACE and RTG methods at MRCP provided prominently clinical information for the common bile duct, gall bladder. If machines have not limitation with performance, induction of breathing holding also will help getting diagnistic quality.

  • PDF