• 제목/요약/키워드: Dew-Point

검색결과 192건 처리시간 0.031초

주파수변조장치를 이용한 열펌프식 공기조화기의 냉방-난방에 관한 실험적 연구 (An Experimental Study on the Performance of Heat Pump Air Conditioner according to Frequency Modulator for Cooling and Heating)

  • 이대우;조진호
    • 설비공학논문집
    • /
    • 제1권3호
    • /
    • pp.203-209
    • /
    • 1989
  • This paper is an experimental study on the pleasantly suitable cool/warm air conditioning system in order to minimize the energy consumption by attaching the electronic-controlled device to the heat pump air conditioning system.While the cool/warm air conditioning, the air temperatures in the entrance and exit of the indoor heat exchangers should be checked and when the surface of heat exchanger is reached to the dew point temperature, a speed of the compressor is to be automatically controlled by anti-dewing system in order to minimize the energy consumption.At the result of this study, the energy consuming amount is saved about 5% more than that of the conventional air conditioning system by prevent unnecessary dew forming.

  • PDF

이그루 탄약고 결로문제 해결에 대한 물리적 고찰 (내부온도를 높여서 상대습도를 낮추는 방안에 대하여) (A Physical Study on the Dew Problem of Igloo Type Military Magazine)

  • 이성태
    • 한국군사과학기술학회지
    • /
    • 제8권3호
    • /
    • pp.111-115
    • /
    • 2005
  • The compact storage of ammunitions in magazine causes serious dew problem on the surface of the shell. Lots of previous studies try to solve this problem by increasing the temperature of air in military magazine. They tried to reduce relative humidity by increasing the temperature of air, but all of them failed. One of the major reasons of these failures is analysed based on the point of view of physics.

다성분 탄화수소혼합물 포화물성해석 수렴도 향상 연구 (Study on the Convergency Improvement Method for the Saturation-Property Calculation of Multi-Component Hydrocarbon Systems)

  • 신창훈;안승희;이정환;성원모
    • 대한기계학회논문집B
    • /
    • 제34권10호
    • /
    • pp.947-955
    • /
    • 2010
  • 대부분의 석유 가스전은 탄화수소혼합물과 일반기체 등 저류층 내부 유체의 성분조성에 따라 저류층내 상거동 특성이 매우 민감하게 변화한다. 석유 가스전의 평가와 개발 생산계획을 수립함에 있어, 이러한 상거동에 따른 기체와 액체의 성분비 결정과 석유와 가스의 이상유동 해석을 위한 저류유체의 PVT관계 및 포화물성의 규명은 필수적이다. 이중에서 특히, 포화물성의 계산은 수렴성이 나빠, 이상 유동의 해석적 연구에 있어서 많은 어려움을 초래하는 원인이 되고 있다. 이에 본 연구에서는 포화물성 의 계산에 있어서 수렴도 향상을 위한 새로운 초기값 추정 방법과 근 탐색 알고리듬을 제안하고, 성능비교 등을 통한 수렴도 영향인자에 대한 분석을 시도하였다. 결과적으로, 제안된 방법을 통해 포화물성 해석 수렴성을 개선하였고 GUI 기반의 새로운 다성분 다상거동해석 시뮬레이터의 개발에 적용하였다.

통계적 모형을 통한 법주사와 선암사 목조건축물의 기상인자에 대한 상관성 분석 (Correlation Analysis of Meteorological Factors for Wooden Building in Beopjusa and Seonamsa Temples by Statistical Model)

  • 김영희;김명남;임보아;이정민;박지희
    • 보존과학회지
    • /
    • 제34권5호
    • /
    • pp.387-396
    • /
    • 2018
  • 국내 목조건축문화재는 자연환경에 그대로 노출되어 있어 생물피해와 여러 환경요인에 의해 피해가 가속화되고 있다. 이에 본 연구에서는 보은 법주사와 순천 선암사에 기상인자 모니터링을 위한 자동기상측정장비를 설치하여 기상데이터를 수집하였다. 이들 데이터에 통계 모형을 적용하여 기상인자를 예측하고 기상인자별 예측성능을 비교하였다. 그 결과, 법주사와 선암사 두 곳 모두에서 대기온도와 이슬점온도의 상관계수가 0.95 이상으로 가장 높게 나타났으며 상대습도의 상관계수는 0.65로 낮게 나타났다. 결과적으로 일반선형모형은 대기온도와 이슬점온도를 예측하기에 적합하다는 것을 확인하였다. 기상인자들 사이의 상관성을 분석한 결과, 법주사와 선암사 모두 대기온도와 이슬점온도, 일사량과 증발량 사이에 강한 양의 상관성을 보였으며, 법주사에서는 대기온도와 증발량이 약한 양의 상관성을 나타내었고 선암사에서는 풍속이 대기온도와 상대습도에 대하여 약한 음의 상관성을 나타내었다. 선암사의 풍속은 겨울에 높고 여름에 평균 이하로 낮아지는 패턴을 보이는데, 이것은 대기온도와 상대습도가 높은 여름철에 수분의 증발을 막고 정체시키는 역할을 하는 것으로 판단되며, 결과적으로 이것이 선암사의 목조건축물 피해를 가속화시키는 것으로 판단된다.

대전력 반도체 정류기 수냉식 냉각 설비 냉매 온도 제어시스템에 관한 연구 (The Study of Thyristor Valve Water Cooling Control Systems)

  • 임익헌;류호선
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.230-233
    • /
    • 1999
  • The design and implementation of thyristor water cooling control systems in considered in this pape Coolant water is pumped through the thyristor heat sinks where heat is transferred from the thyristo to the water. This water is then pumped through outdoor air-to-water heat exchangers where heat I transferred to the outside air. Since the water must be pure, it is filtered and de-ionized. Also the water temperature must be below dew-point temperature. Redundant pumps, outdoor heat exchangers, power supply system, controller monitoring system are provided for system reliability and availability.

  • PDF

7월의 부산지방의 이류무예보에 관하여 (Forecasting Advection Fog at Busan Area in the Month of July)

  • 한영호
    • 수산해양기술연구
    • /
    • 제9권1호
    • /
    • pp.19-23
    • /
    • 1973
  • The method of forecasting advection fog at Busan area in July is developed using the Spreen's scatter-diagraam technique. The used Parameters are (1) air temperature (2) dew-point temperature, (3) sea surface temperature (4) resultantt wind direction (5) resultant wind speed in Busan. The skill score and the pcr cent correct based on 4 yeare of dependent data are 0.79 and 90.3% respectively.

  • PDF

Influence of Nitrogen/Hydrogen Atmospheres on Sintered Properties of P/M Components

  • Philips, Thomas;Koh, Kyung-Sug
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.818-819
    • /
    • 2006
  • The effect of individual gas constituents in a sintering atmosphere is examined to optimize the sintered properties of Iron-Carbon P/M components. The influence of sintered properties is reviewed as a function of hydrogen percentages and dew point in the sintering zone. Microstructures, porosity, pore morphology and dimensional changes are the subject of this review. The effects of CO containing atmospheres are compared against the non CO atmospheres in terms of hardness, carbon control and dimensional changes.

  • PDF

R14와 질소 혼합유체를 사용하는 극저온 열사이펀의 과도상태 거동 (Transient behavior of cryogenic thermosiphon working with R14 and nitrogen mixture)

  • 이지성;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.66-70
    • /
    • 2010
  • The operational temperature range of thermosiphon is generally limited from the critical point to the triple point of the working fluid to maintain two-phase state. Thermosiphon with mixed working fluid has a potential to widen the operational temperature range. In this study, the physical behavior of mixed working fluid during the transient operation of thermosiphon was analyzed with temperature-mole fraction diagram. The condenser and the evaporator temperature variations were explained by the dew line and the bubble line of the mixture. It is encouraging that the thermosiphon operation commences early with larger fraction of high boiling point component, but the temperature gap between the condenser and the evaporator due to the separation of two components has a negative effect on the officient cool down process.

An Experimental Study on the Evaluation of Fastening Unit Insulation Developed for the Insulation of Curtain Wall

  • Kim, Bong-Joo;Kim, Kyeong-A
    • 한국건축시공학회지
    • /
    • 제12권2호
    • /
    • pp.243-256
    • /
    • 2012
  • This study is the experimental study to improve the insulation of the fastening unit system, which has the most vulnerable insulation in the curtain walls. The Fastening Units were designed and fabricated to minimize the connection part of mullions. In addition, slight movements were taken into account and the performance of the middle layer was evaluated by forming an insulation layer with the vibration-proof rubber and the silicon to satisfy the mechanical and thermal performance criteria. A total of 10 experiments were performed under various conditions, such as indoor-outdoor temperature difference, type of insulation material, thickness of insulation material, and others. using the fabricated Fastening Units. As a result, the vibration-proof rubber insulation showed the temperature difference of $2.2^{\circ}C-5.0^{\circ}C$, and the silicon insulation showed the temperature difference of $2.8^{\circ}C-4.5^{\circ}C$, compared to the non-insulated Fasteniirature difference, typesng Units. When these results were compared with the psychometric chart graph, the insulated Fastening Unit designed in this study can be considered to prevent the dew condensation.

도로 노면결빙 판정모델을 적용한 도로결빙 예측에 대한 연구 (A study on road ice prediction by applying road freezing evaluation model)

  • 임희섭;김상태
    • 한국응용과학기술학회지
    • /
    • 제37권6호
    • /
    • pp.1507-1516
    • /
    • 2020
  • 본 연구는 도로 노면결빙 판정 알고리즘을 적용하여 도로결빙 구간에 대한 시나리오를 분석하였다. 도로결빙 알고리즘 적용을 위해서, 도로 결빙에 대한 영향인자를 검토하고, 분석을 위해서 목감IC, 정릉터널, 성산대교, 염창교 등 4지점의 관측자료를 활용하였다. 관측소는 모두 고속화도로에 설치되어 있으며, 도로 결빙 특성 분석을 위하여 분류하였다. 도로 결빙 판정 알고리즘의 노면온도-노점온도 차가 3℃ 이하일 때 도로결빙 발생 구간을 확인하고 결빙 구간의 노면상태와 수막두께 변화를 통해 도로 결빙 판정을 도출하였다.