• Title/Summary/Keyword: Dew Point Temperature

Search Result 133, Processing Time 0.024 seconds

A Study on the Effects of System Pressure on Heat and Mass Transfer Rates of an Air Cooler

  • Jung, Hyung-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.696-702
    • /
    • 2002
  • In the present paper, the effects of inlet pressure on the heat and mass transfer rates of an air cooler are numerically predicted by a local analysis method. The pressures of the moist air vary from 2 to 4 bars. The psychrometric properties such as dew point temperature, relative humidity and humidity ratio are employed to treat the condensing water vapor in the moist air when the surface temperatures are dropped below the dew point. The effects of the inlet pressures on the heat transfer rate, the dew point temperature, the rate of condensed water, the outlet temperature of air and cooling water are calculated. The condensation process of water vapor is discussed in detail. The results of present calculations are compared with the test data and shows good agreements.

Earth Science Prospective Teachers' Perceptions on the Relationship between Absolute Humidity and Dew Point Temperature (절대 습도와 이슬점 온도의 관계에 대한 지구과학 예비 교사들의 인식)

  • Kang, So Ra;Seo, Eun-Kyoung;Kim, Dong Young
    • Journal of the Korean earth science society
    • /
    • v.40 no.6
    • /
    • pp.624-638
    • /
    • 2019
  • A questionnaire was administered, and all responses were analyzed to examine prospective teachers' conceptual understanding of the relationship between dew point temperature and absolute humidity in air parcels. The responses revealed that many prospective teachers have substantial misconceptions about the relationship. For example, some thought that the absolute humidity and the dew point temperature are proportional to each other, and that the dew point temperature is proportional to the water vapor mass in the parcel. The misconceptions seemingly stemmed from inadequate descriptions on the relationship in middle-school science textbooks of the 7th and 2007 revised curricula. The study notes that the first year students' textbook of the 2015 revised curriculum introduced the concepts of evaporation, condensation, and volume changes as a function of gaseous pressure and temperature, from a perspective of molecular motion. It is suggested that keeping this perspective in the middle school curriculum, while introducing water vapor pressure as the measure of water vapor amount and dew point temperature, should help prevent middle school teachers and students from having misconceptions. There should be a concerted effort to make the science curriculum more consistent and coherent across the grade levels.

A Study on the Mass Collection Efficiency in Collector Step of Electrostatic Precipitator by Physical Gas Characterization (전기집진장치에서 가스의 물리적인 특성에 따른 포집구역내의 입자포집율 연구)

  • Ha, Sang-An;Im, Gyeong-Taek;Sin, Nam-Cheol
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.36-40
    • /
    • 1998
  • This study was carried out to investigate the collection Efficiency of mass in collector step at the different of physical gas characterization. This work has focused on the dependence of the collection efficiency of mass in the collector zone of a two-stage set up field with gas temperature T and the dew point tmeperature. To identify the dependence of the mass collection efficiency on the Bounded plate of the collector zone MP.k by the spectre electric resistance of dust $p_e$. and the relative humidify ${\varphi}$, 20 at- tempts have been made with three different gas temperature ($50{\circ}C, 80{\circ}C, 110{\circ}C$) at different dew point. At the specific electric resistance of dust $p_e$=$10^6{\Omega}m$ which relative humidity corresponds to $\phi$ > 15%, a easy rise of the sounded plate secluded dust mass share was measured atwain. As the result of the higher cohesion imprisonment power due to the adsorbtion of particle, the rinse of the relative humidity developed on the particle surface. Therefore, the collection efficiency of mass was not predominant the high temperature T in the collector zone, neither was the pecific ellectric resistance of dust dependent.

  • PDF

A Study on the Measurement of SOx-Dew Point (About the Corosin of Briquet -Burning Hot Water Boiler) ($SO_x^-$ 노점 측정에 관한 연구 (연탄 온수보일러의 부식문제에 관하여))

  • Chae Jae-Ou;Yong Gee-Joong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.4
    • /
    • pp.252-263
    • /
    • 1983
  • In the briquet-burning hot water boiler the $SO_x$-dew point is calculated and found to be between $130^{\circ}C\;and\;154^{\circ}C$. The corrosion rate depends on the surface temperature and the concentration of the condensate on the surface. The concentration of the condensate is decided acoording to the difference detween $SO_x$-dew point and the surface temperature. When the surface temperature is $80^[\circ}C$, the concentration of the condensate is also high (0.15N). Therefore the high concentration and high temperature promote the high corrosion rate of $14{\times}13^{-3}g/100cm^2{\cdot}hr$ on the SS41 material. On the other hand, when the surface temperatures are $60^{\circ}C\;and\;40^{\circ}C$, the concentrations and the co..sion rates are reduced dramatically to $0.11\;N,\;8.6{\tiems}10^{-3}g/100cm^2{\cdot}hr$ and $5{\tiems}10^{-4}g/100cm^2{\cdot}hr$ respectively.

  • PDF

On Interesting Correlation between Meteorological Parameters and COVID-19 Pandemic in Saudi Arabia

  • Haq, Mohd Anul;Ahmed, Ahsan
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.4
    • /
    • pp.159-168
    • /
    • 2022
  • The recent outbreak of COVID-19 pandemic cases around the globe has affected Saudi Arabia with around 15, 00,000 confirmed cases within the initial 4 months of transmission. The present investigation analyzed the relationship between daily COVID-19 confirmed cases and meteorological parameters in seventeen cities of KSA. We used secondary published data from the Ministry of Health, KSA daily dataset of COVID-19 confirmed case counts. The meteorological parameters used in the present investigation are temperature, humidity, dew point, and wind speed. Pearson correlation and Spearman rank correlation tests were utilized for data analysis. The incubation period of COVID-19 varies from 1 day to 14 days as per available information. Therefore, an attempt has been made to analyze the effects of meteorological factors with bins of 1, 3, 7, and 14 days. The results suggested that the highest number of correlations (15 cities) was observed for temperature (maximum, minimum, and average) and humidity (12 cities) (minimum and average). The dew point showed relationships for 7 cities and wind showed moderate correlations only for 2 cities. The study results might be useful for authorities and stakeholders in taking specific measures to combat the Covid-19 pandemic.

The Sintering Behaviour of Fe-Mn-C Powder System, Correlation between Thermodynamics and Sintering Process, Mn Distribution, Microstructure

  • Hryha, Eduard;Dudrova, Eva
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.839-840
    • /
    • 2006
  • Sintering behavior of the Fe-0.8Mn-0.5C powder system was studied on the specimens with a density of ${\sim}7.0g/cc$ sintered at $1120^{\circ}C$ for 30 min in a gas mixture of $7%H_2/93%N_2$ with the inlet dew point of $-60^{\circ}C$. During the atmosphere monitoring ($CO/CO_2$-content and dew point) was showed, that carbothermical reduction occurs in two different temperature ranges; three peaks of dew point profile also can be distinguished during sintering cycle as well. Following sintering the Mn-content distribution and microstructures around the Mn-source were micro-analytical evaluated; the results showed that manganese travels through porous iron matrix up to ${\sim}60{\mu}m$.

  • PDF

Experiment of frost growth on the parallel plates in the condition of laminar and low humidity (층류유동 저습도 조건에서의 평행평판형 냉각판 서리성장 실험)

  • 한흥도;노승탁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.440-447
    • /
    • 1999
  • The frosting characteristics on the vertical parallel plates with three cooling plates were experimentally investigated. The experimental parameters were the cooling plate temperature, the air humidity, the air temperature, the air Reynolds number, and the location. The frosting conditions were limited to air temperatures from 10 to $15^{\circ}C$ , air Reynolds numbers from 1600 to 2270, air humidity ratios from 0.00275 to 0.0037kgw/kga and cooling plate temperatures from -10 to $-20^{\circ}C$. Frost growth and density toward the front of the plate were more thick and dense than toward the rear. Frost growth increased with decreasing plate temperature and increasing humidity. In the conditions of the laminar flow, dew point below $0^{\circ}C$and non-cyclic frosting period, frost thickness increased with increasing air temperature. The reason of increasing frost thickness with increasing air temperature was sublimation-ablimation process. The average growth thickness along the locations showed little dependence on the Reynolds numbers.

  • PDF

Temporal and Spatial correlation of Meteorological Data in Sumjin River and Yongsan River Basins (섬진강 및 영산강 유역 기상자료의 시.공간적 상관성)

  • 김기성
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.6
    • /
    • pp.44-53
    • /
    • 1999
  • The statistical characteristics of the factors related to the daily rainfall prediction model are analyzed . Records of daily precipitation, mean air temperature, relative humidity , dew-point temperature and air pressure from 1973∼1998 at 8 meteorological sttions in south-western part of Korea were used. 1. Serial correlatino of daily precipitaiton was significant with the lag less than 1 day. But , that of other variables were large enough until 10 day lag. 2. Crosscorrelation of air temperature, relative humidity , dew-point temperature showed similar distribution wiht the basin contrours and the others were different. 3. There were significant correlation between the meteorological variables and precipitation preceded more than 2 days. 4. Daily preciption of each station were treated as a truncated continuous random variable and the annual periodic components, mean and standard deviation were estimated for each day. 5. All of the results could be considered to select the input variables of regression model or neural network model for the prediction of daily precipitation and to construct the stochastic model of daily precipitation.

  • PDF

Analysis of Water Transport through Measurement of Temperature and Relative Humidity in PEMFC at OCV (개방회로 상태 PEMFC 내부 온도와 습도 측정을 통한 수분투과 분석)

  • KIM, TAEHYEONG;HAN, JAESU;YU, SANGSEOK
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.4
    • /
    • pp.353-362
    • /
    • 2022
  • In this study, water diffusion in proton exchange membrane fuel cell at open circuit voltage (OCV) was analyzed through experiment. First, the reliability of the micro-sensor (SHT31) was verified. It was concluded the micro-sensor has an excellent reliability at 60℃ and 70℃. After the sensor reliability test, the temperature and relative humidity measurement in bipolar-plate was conducted at OCV. To analyze water distribution and water flux, the temperature and relative humidity was converted into dew point. To the end, it was found water concentration affects water diffusion.

Calculation of Adequate Remodeling Period for The Improvement of Thermal Insulation Performance of External Walls in Deteriorated Apartments

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • v.17 no.2
    • /
    • pp.5-12
    • /
    • 2017
  • Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.