• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.039 seconds

Fluorescent Blue Materials for Efficient Organic Light-Emitting Diode with High Color Purity

  • Choi, Kyung-Sun;Lee, Chan-Hyo;Lee, Kwan-Hee;Park, Su-Jin;Son, Seung-Uk;Chung, Young-Keun;Hong, Jong-In
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.10
    • /
    • pp.1549-1552
    • /
    • 2006
  • We report a new series of blue dopants composed of both electron donating and electron accepting moieties in one molecule, based on nalidixic acid. The EL device derived from the dopant exhibits pure blue light emission (0.15, 0.14) The current efficiency is estimated to be 3.88 cd/A at 100 $cd/m^2$, which shows remarkable enhancement, compared to that of the host itself (2.5 cd/A at 100 $cd/m^2$) under the same conditions. These results demonstrate that the incorporation of a proper guest into the host in a guest-host doped system improves not only the purity of the fluorescent blue emission but also elevates its quantum efficiency, thus improving the OLED performance.

Comparison of Irrigation Methods for Upland Crops (전작물의 관개법에 관한 비교연구)

  • 정하우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.12 no.1
    • /
    • pp.1861-1871
    • /
    • 1970
  • This experiment was carried out to compare soil moisture contents and the amounts of irrigation water by varying irrigating methods for chinese cabbages. The irrigating methods were non-irrigation (Plot A), furrow irrigation(Plot B). fixed nozzle pipe irrigation(Plot C), subsoil pipeline irrigation at the depths of 15cm. and 30cm., laying out in the middle of the rows of chinese cabbages(Plot D) and subsoil pipeline irrigation at the depths of 15cm, and 30cm., laying out beneath the rows of the roots of chinese cabbages(Plot E). In this experiment soil moisture contents were measured by using a simple electric device. As a result, the fallowing items are derived; 1) A significionce of 5% was observed between the yields produced at the furrow irrigation plot and fixed nozzle pipe irrigation plot, and those at the non-irrigation plot and subsoil pipe-line irrigation plot. 2) In the subsoil pipe-line irrgatiion, the Plot D type was observed to be slightly better than the Plot E type in the effect of the growth of cabbages. 3) The ratio of the amounts of irrigation water applied in the furrow irrigation plot, fixed nozzle pipe irrigation plot and subsoil pipe-line irrigation plot is approximately 3.2:2.1.

  • PDF

The Optimization of Output Characteristics with High Repetition Rate Pulsed $CO_2$ Laser Using SMPS (SMPS 방식의 고반복 펄스형 $CO_2$레이저의 출력특성 최적화)

  • Lee, D.H.;Chung, H.J.;Kim, D.W.;Kim, W.Y.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2192-2194
    • /
    • 1999
  • In this study, We have accomplished a new approach to develope a cheap and compact pulsed $CO_2$ laser system. We used a fast SCR as switching device instead of a thyatron in the pulsed power supply. Using the Pulse transformer, energy in the condenser is tranferred to the secondary, electrodes of discharge tube, from the primary. An axial and water cooled type was adopted as the laser cavity. The laser performance characteristics as various parameters, such as gas pressure and pulse repetition rate, have been investigated. As a result, the maxium laser output was 12.3[W] at a pulse repetition rate of 120[pps] and a filling pressure of 12[Torr].

  • PDF

Performance Evaluation of a Two-Stage Compression Heat Pump System for District Heating (지역난방용 2단 압축 히트펌프 시스템 성능평가)

  • Park, Cha-Sik;Cha, Dong-An;Kwon, Oh-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.585-590
    • /
    • 2012
  • The objective of this study is to investigate the performance of a two-stage compression heat pump system for district heating. The experimental setup of heat pump consists of compressor, condenser, evaporator, expansion device, intercooler, flash tank, oil separator and accumulator. The experimental evaluations on the two-stage compression cycle were carried out under various operating conditions which were heat source temperature, the degree of compressor inlet superheat, and intermediate pressure. The temperature ranges of unutilized energy as the heat source were used in the test conditions. As the heat source temperature increased from $10^{\circ}C$ to $30^{\circ}C$, the COP and heating capacity of the heat pump system increased by 22.6% and 45.8%, respectively. The performance of the two-stage heat pump system increased by 5.2% with the variation of the intermediate pressure in the same heat source temperature conditions.

u-Manufacturing needs M2M (Machine to Machine) for Ubiquitous Computing World

  • Cha, Suk-Keun;Song, Jun-Yeob;Choi, Jin-Seok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1112-1114
    • /
    • 2005
  • Core position of the M2M (Machine to Machine) is device integration fusion using an emerging wireless and next internet technologies as well as IEEE 802.x, Bluetooth, Zigbee, DMB, Wibro etc. for ubiquitous environment that is complementary with IT839 strategy from Ministry of Information & Communication. This paper define and deploy about major functional requirements of M2M devices and middleware for how to it works, worldwide M2M technology trend & activities with its current & future application in manufacturing area that is called u-Manufacturing (Ubiquitous Manufacturing).

  • PDF

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.

Effect of Transverse Magnetic Field on Build-up Region of 6 MV Photon Beam (6 MV 광자선의 선량 상승 영역에 대한 자기장 영향)

  • Shin, Seong Soo;Choi, Wonsik;Ahn, Woo Sang;Kwak, Jungwon
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.1
    • /
    • pp.18-22
    • /
    • 2017
  • The purpose of this study was to present an improved method of dose modulation over the increase of build-up for existing 6 MV photon beam. Two neodymium permanent magnets with a strength of 0.5 T (Tesla) were applied with a magnetic field perpendicular to the photon beam. The effects of dose on build-up region with or without the magnetic field were measured according to the magnet-to-magnet distance (MMS) and the magnet-to-surface distance (MSD). For MMS = 6 cm and MSD = 2.5 cm, $D_{0mm}$, $D_{2mm}$, $D_{5mm}$, and $D_{10mm}$ showed improved doses of 6.8 %, 14.6 %, 6.9 %, and 2.1 %, respectively, as compared with 6 MV open beam. In this study, the device with low strength magnetic field can be applied directly to the outside of the human body when the target volume located close to the skin is delivered with radiation. It is expected that the method of build-up modulation using a low strength magnetic field will be feasible in the clinical applications.

Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle (마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발)

  • Kim, Jun-tae;Joo, Kyu-tai;Cha, Eun Jong;Kim, Myung-mi;Jeong, Jin-hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.394-402
    • /
    • 2021
  • The entry of an aging society and the extension of human life expectancy, the increasing interest in women's social advancement and men's appearance, and the natural interest in K-culture through media media, while receiving worldwide attention, Focus on K-Bueaty. Recently, looking at the occupation of the medical tourism field, in the case of aesthetic medicine tourism such as molding and dermatology, it has gained popularity not only in Asia such as China and Japan, but also in North America and Europe. The first external confirmation of human aging is the wrinkles on the skin of the face. Clean, wrinkle-free, elastic and healthy skin is a desire of most people. Skin condition and condition such as focused ultrasonic stimulation (HIFU: High Intensity Focused Utrasound) and low frequency, high frequency (RF: Radio Frequency), galvanic therapy using microcurrent, cryotherapy using rapid cooling, etc. Depending on the method of management, the effect of the treatment differs depending on the output and the stimulation site, etc., even in the treatment of medical equipment and beauty equipment using the same mechanism. In this research, in order to develop invasive high-frequency dermatological devices using a large number of beauty medical devices and microneedles of beauty devices, the international standards IEC 60601-2 (standards for individual medical devices) and MFDS (Ministry of) We designed and developed a high-frequency output device in compliance with the high-frequency stimulation standard announced in the Food and Drug Safety (Ministry of Food and Drug Safety). The circuit design consists of an amplifier (AMP: Amplifier) using Class-A Topology and a power supply device using Half-Bridge Topology. As a result of measuring the developed high-frequency output device, an average efficiency of 63.86% was obtained, and the maximum output was measured at 116.7W and 50.67dBm.

Wearable Robot System Enabling Gaze Tracking and 3D Position Acquisition for Assisting a Disabled Person with Disabled Limbs (시선위치 추적기법 및 3차원 위치정보 획득이 가능한 사지장애인 보조용 웨어러블 로봇 시스템)

  • Seo, Hyoung Kyu;Kim, Jun Cheol;Jung, Jin Hyung;Kim, Dong Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.10
    • /
    • pp.1219-1227
    • /
    • 2013
  • A new type of wearable robot is developed for a disabled person with disabled limbs, that is, a person who cannot intentionally move his/her legs and arms. This robot can enable the disabled person to grip an object using eye movements. A gaze tracking algorithm is employed to detect pupil movements by which the person observes the object to be gripped. By using this gaze tracking 2D information, the object is identified and the distance to the object is measured using a Kinect device installed on the robot shoulder. By using several coordinate transformations and a matching scheme, the final 3D information about the object from the base frame can be clearly identified, and the final position data is transmitted to the DSP-controlled robot controller, which enables the target object to be gripped successfully.

Measurements of Setup Error and Physiological Movement of Liver by Using Electronic Portal Imaging Device in Patients with Hepatocellular Carcinoma (간암환자에서 Electronic Portal Imaging Device(EPID)를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정)

  • Keum Ki Chang;Lee Sang-wook;Shin Hyun Soo;Kim Gwi Eon;Sung Jinsil Seong;Lee Chang Geol;Chu Sung Sil;Chang Sei-Kyung;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.107-113
    • /
    • 2000
  • Purpose : The goal of this study 닌as to improve the accuracy of three-dimensional conformal radiotherapy (3-D CRT) by measuring the treatment setup error and physiological movement of liver based on the analysis of images which were obtained by electronic portal imaging device (EPID). Materials and Methods : For 10 patients with hepatocellular carcinoma, 4-7 portal images were obtained by using EPID during the radiotherapy from each patient daiiy. We analyzed the setup error and physiological movement of liver based on the verification data. We also determined the safety margin of the tumor in 3-D CRT through the analysis of physiological movement. Results : The setup errors were measured as 3mm with standard deviation 1.70 mm in x direction and 3.7 mm with standard deviation 1.88 mm in y direction respectively. Hence, deviation were smaller than 5mm from the center of each axis. The measured range of liver movement due to the physiological motion was 8.63 mm on the average. Considering the motion of liver and setup error, the safety margin of tumor was at least 15 mm. Conclusion : EPID is a very useful device for the determination of the optimal margin of the tumor, and thus enhance the accuracy and stability of the 3-D CRT in patients with hepatocellular carcinoma.

  • PDF