• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.039 seconds

A 45 nm 9-bit 1 GS/s High Precision CMOS Folding A/D Converter with an Odd Number of Folding Blocks

  • Lee, Seongjoo;Lee, Jangwoo;Song, Minkyu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.4
    • /
    • pp.376-382
    • /
    • 2014
  • In this paper, a 9-bit 1GS/s high precision folding A/D converter with a 45 nm CMOS technology is proposed. In order to improve the asymmetrical boundary condition error of a conventional folding ADC, a novel scheme with an odd number of folding blocks is proposed. Further, a new digital encoding technique is described to implement the odd number of folding technique. The proposed ADC employs a digital error correction circuit to minimize device mismatch and external noise. The chip has been fabricated with 1.1V 45nm Samsung CMOS technology. The effective chip area is $2.99mm^2$ and the power dissipation is about 120 mW. The measured result of SNDR is 45.35 dB, when the input frequency is 150 MHz at the sampling frequency of 1 GHz. The measured INL is within +7 LSB/-3 LSB and DNL is within +1.5 LSB/-1 LSB.

A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography (C-arm CT의 필수 성능평가 기준 마련을 위한 연구)

  • Kim, Eun-Hye;Park, Hye-Min;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Hemodynamic effects of Chunwangbosim-dan - A 3-dimensional radial pulse tonometry device study (3차원 맥영상 검사로 살펴본 천왕보심단이 심혈관계에 미치는 영향)

  • HeeJung KANG;YoungSang KUN;Tae Hun KU;Gyeung Cheul KIM
    • Journal of Convergence Korean Medicine
    • /
    • v.6 no.1
    • /
    • pp.5-20
    • /
    • 2024
  • Objectives: This study was aimed to evaluate the hemodynamic feasibility using pulse parameters as a way to establish safe dose guidelines for Chunwangbosim-dan, and to provide a foundation for developing evidence-based guidelines for clinical use. Methods: Forty-one volunteers were recruited to participate in a study examining the changes in pulse wave characteristics following the ingestion of Chunwangbosim-dan, over a period of 2 weeks, and pulse wave measurements were taken before and after the administration. Pulse wave parameters were measured in this study using a 3-dimensional radial pulse tonometry device(DMP-Lifeplus). In addition, questionnaire, blood pressure, temperature, and body composition were also measured as secondary measures. Results: Fifteen minutes after administration of Chunwangbosim-dan, the non-adverse event group(non-AE) exhibited a statistically significant increase in several power and pressure-related parameters, including h1, h3, h4, h5, SA, PA and PW, while the adverse event group(AE) showed a trend of decreasing stroke volume and increasing Systemic Vascular Resistance Index(SVRI) and applied pressure. After 2 weeks of administration, non-adverse event group(non-AE) exhibited significant changes in standard deviation of pulse rate and HRV_LH ratio. Notably, there are significant differences between AE group and non-AE group in h4/h1, w/t, applied pressure, SV and pulse rate. Conclusion: These findings suggest that pulse parameters may be a useful way to establish safe dosing guidelines for Chunwangbosim-dan. Further research is needed to confirm these results and to develop evidence-based guidelines for clinical use.

  • PDF

Forgery Protection System and 2D Bar-code inserted Watermark (워터마크가 삽입된 이차원 바코드와 위.변조 방지 시스템)

  • Lee, Sang-Kyung;Ko, Kwang-Enu;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.6
    • /
    • pp.825-830
    • /
    • 2010
  • Generally, the copy protection mark and 2D bar-code techniques are widely used for forgery protection in printed public documents. But, it is hard to discriminate truth from the copy documents by using exisiting methods, because of that existing 2D-barcode is separated from the copy protection mark and it can be only recognized by specified optical barcord scanner. Therefor, in this paper, we proposed the forgery protection tehchnique for discriminating truth from the copy document by using watermark inserted 2D-barcord, which can be accurately distinguished not only by naked eye, but also by scanner. The copy protection mark consists of deformed patterns that are caused by the lowpass filter characteristic of digital I/O device. From these, we verified the performance of the proposed techniques by applying the histogram analysis based on the original, copy, and scanned copy image of the printed documents. Also, we suggested 2D-barcord confirmation system which can be accessed through the online server by using certification key data which is detected by web-camera, cell phone camera.

Design of Ultra Small Dual Cross-Dipole Antenna for Mobile Devices (모바일 기기를 위한 초소형 이중 교차 다이폴 안테나 설계)

  • Sa, Gi-Dong;Kim, Sa-Ung;Lim, Yeong-Seog
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.3
    • /
    • pp.489-496
    • /
    • 2019
  • In this paper, we design and fabricate an ultra small dual crossed dipole antenna operating at 2.4 GHz frequency. In order to miniaturize the size of the antenna so that it can be applied to a mobile device, a cross dipole is disposed on the upper two layers and a reflection plane, a horizontal matching circuit and a ground plane are arranged on each layer. The circuit was connected by a vertical through-hole. The size of the fabricated antenna is $21.61mm{\times}16.88mm{\times}1.27mm$, the measured reflection coefficient is -31.5 dB, and the bandwidth below -10 dB is 112 MHz. In addition, since the gain of the antenna is -4 dBi, it has the omnidirectional radiation characteristic, so it can be applied to various fields as an antenna for mobile devices.

MPEG-D USAC: Unified Speech and Audio Coding Technology (MPEG-D USAC: 통합 음성 오디오 부호화 기술)

  • Lee, Tae-Jin;Kang, Kyeong-Ok;Kim, Whan-Woo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.7
    • /
    • pp.589-598
    • /
    • 2009
  • As mobile devices become multi-functional, and converge into a single platform, there is a strong need for a codec that is able to provide consistent quality for speech and music content MPEG-D USAC standardization activities started at the 82nd MPEG meeting with a CfP and approved WD3 at the 88th MPEG meeting. MPEG-D USAC is converged technology of AMR-WB+ and HE-AAC V2. Specifically, USAC utilizes three core codecs (AAC ACELP and TCX) for low frequency regions, SBR for high frequency regions and the MPEG Surround tool for stereo information. USAC can provide consistent sound quality for both speech and music content and can be applied to various applications such as multi-media download to mobile device Digital radio Mobile TV and audio books.

A User-friendly Remote Speech Input Method in Spontaneous Speech Recognition System

  • Suh, Young-Joo;Park, Jun;Lee, Young-Jik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.2E
    • /
    • pp.38-46
    • /
    • 1998
  • In this paper, we propose a remote speech input device, a new method of user-friendly speech input in spontaneous speech recognition system. We focus the user friendliness on hands-free and microphone independence in speech recognition applications. Our method adopts two algorithms, the automatic speech detection and the microphone array delay-and-sum beamforming (DSBF)-based speech enhancement. The automatic speech detection algorithm is composed of two stages; the detection of speech and nonspeech using the pitch information for the detected speech portion candidate. The DSBF algorithm adopts the time domain cross-correlation method as its time delay estimation. In the performance evaluation, the speech detection algorithm shows within-200 ms start point accuracy of 93%, 99% under 15dB, 20dB, and 25dB signal-to-noise ratio (SNR) environments, respectively and those for the end point are 72%, 89%, and 93% for the corresponding environments, respectively. The classification of speech and nonspeech for the start point detected region of input signal is performed by the pitch information-base method. The percentages of correct classification for speech and nonspeech input are 99% and 90%, respectively. The eight microphone array-based speech enhancement using the DSBF algorithm shows the maximum SNR gaing of 6dB over a single microphone and the error reductin of more than 15% in the spontaneous speech recognition domain.

  • PDF

A 2-Tier Server Architecture for Real-time Multiple Rendering (실시간 다중 렌더링을 위한 이중 서버 구조)

  • Lim, Choong-Gyoo
    • Journal of Korea Game Society
    • /
    • v.12 no.4
    • /
    • pp.13-22
    • /
    • 2012
  • The wide-spread use of the broadband Internet service makes the cloud computing-based gaming service possible. A game program is executed on a cloud node and its live image is fed into a remote user's display device via video streaming. The user's input is immediately transmitted and applied to the game. The minimization of the time to process remote user's input and transmit the live image back to the user and thus satisfying the requirement of instant responsiveness for gaming makes it possible. However, the cost to build its servers can be very expensive to provide high quality 3D games because a general purpose graphics system that cloud nodes are likely to have for the service supports a single 3D application at a time. Thus, the server must have a technology of 'realtime multiple rendering' to execute multiple 3D games simultaneously. This paper proposes a new architecture of 2-tier servers of clouds nodes of which one group executes multiple games and the other produces game's live images. It also performs a few experimentations to prove the feasibility of the new architecture.

Using Skeleton Vector Information and RNN Learning Behavior Recognition Algorithm (스켈레톤 벡터 정보와 RNN 학습을 이용한 행동인식 알고리즘)

  • Kim, Mi-Kyung;Cha, Eui-Young
    • Journal of Broadcast Engineering
    • /
    • v.23 no.5
    • /
    • pp.598-605
    • /
    • 2018
  • Behavior awareness is a technology that recognizes human behavior through data and can be used in applications such as risk behavior through video surveillance systems. Conventional behavior recognition algorithms have been performed using the 2D camera image device or multi-mode sensor or multi-view or 3D equipment. When two-dimensional data was used, the recognition rate was low in the behavior recognition of the three-dimensional space, and other methods were difficult due to the complicated equipment configuration and the expensive additional equipment. In this paper, we propose a method of recognizing human behavior using only CCTV images without additional equipment using only RGB and depth information. First, the skeleton extraction algorithm is applied to extract points of joints and body parts. We apply the equations to transform the vector including the displacement vector and the relational vector, and study the continuous vector data through the RNN model. As a result of applying the learned model to various data sets and confirming the accuracy of the behavior recognition, the performance similar to that of the existing algorithm using the 3D information can be verified only by the 2D information.

Angular-based Measurement for Quantitative assay of Albumin in three-dimensional Paper-based analytical Device (회전각도를 이용한 알부민 농도 측정용 3차원 종이 칩)

  • Kim, Dong-Ho;Jeong, Seong-Geun;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.58 no.2
    • /
    • pp.286-292
    • /
    • 2020
  • This study presents an angular-based measurement on three-dimensional paper-based analytical devices (3D-PADs) for quantitative detection of albumin without using an image analyzer. We demonstrate a simple quantitative and straightforward approach based on the angle of the discolored area as detection criteria. 3D-PADs are rapidly fabricated by the wax-printing and laminating process. The 3D-PADs are treated with citrate buffer and tetrabromophenol blue to react with albumin in a sample solution. Dropping sample solution into sample pad in the 3D-PAD, fluid flows toward the assay zone laterally and vertically by capillary action. We find that the change of angle of the discolored area correctly reflects the concentration of albumin and is reliable determinant for the measurement of the albumin concentration. It is the first demonstration of angular-based detection as a simple, inexpensive, and equipment-free approach for point-of-care diagnosis.