• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.043 seconds

Post-annealing Effect of Giant Magnetoresistance-Spin Valve Device for Sensor (센서용 거대자기저항 스핀밸브소자의 열처리 효과)

  • Lee, Sang-Suk;Park, Sang-Hyun;Soh, Kwang-Sup;Joo, Ho-Wan;Kim, Gi-Wang;Hwang, D.G.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.172-177
    • /
    • 2007
  • In order to detect of the magnetic property in the cell unit, we studied the GMR-SV (giant magnetoresistance-spin valves) biosensor, which was depended on the micro patterned features according to two easy directions of longitudinal and transversal axes. Here, the multi layer structure was glass/NiO/NiFe/CoFe/Cu/CoFe/NiFe. The uniaxial anisotropy direction was applied to the patterned biosensor during the deposition and vacuum post-annealing at $200^{\circ}C$ under the magnitude of 300 Oe, respectively. Considering the magnetic shape anisotropy effect, the size of micro patterned biosensor was a $2{\times}5{\mu}m^2$ after the photo lithography process. By our experimental results, we confirmed that the best condition of GMR-SV biosensor should be the same direction of the axis sensing current and the easy axis of pinned NiO/NiFe/CoFe triple layer oriented to the width direction of device, and the direction of the easy axis of free CoFe/NiFe bilayer was according to the longitudinal direction of device.

Risk Assessment of Heavy Metals through Modified Milk Powder and Formulas (조제분유 및 조제식 중 중금속 위해성 평가)

  • Choi, Hoon;Kim, Hyung-Soo;Park, Sun-Hee
    • Food Science of Animal Resources
    • /
    • v.33 no.5
    • /
    • pp.617-625
    • /
    • 2013
  • The present study was carried out to assess dietary exposure and risk for the infant population by lead (Pb), cadmium (Cd), and arsenic (As) exposure through modified milk powder and formulas. Analysis of heavy metals was performed using a microwave device and inductively coupled plasma-mass spectrometry, the method for which was fully validated. Various samples (n=204), including modified milk powder, modified milk, follow-up modified milk powder, infant formula and follow- up formula, were collected from retail outlets and markets across Korea. The mean contents of heavy metals were Pb 0.0004 (modified milk)-0.010 (infant formula) mg/kg, Cd 0.002 (modified milk)-0.007 (follow-up formula) mg/kg, and As 0.004(modified milk)-0.040 (infant formula) mg/kg, respectively. For risk assessment, daily intakes of heavy metals through maximum intake of modified milk powder and formulas were calculated and compared with reference doses established by JECFA and WHO. The dietary exposures of heavy metals were $0.78-1.04{\mu}g$ Pb/d, $0.65-0.87{\mu}g$ Cd/d, and $2.25-3.00{\mu}g$ As/d, corresponding to 2.0-4.5%, 7.1-16.0%, and 0.4-0.9% of reference doses, respectively. Therefore, the level of overall dietary exposure to heavy metals for Korean infant through food intake was below 20% of the reference dose, indicating a low risk to infant consumers.

OFD(Over Flow Drain) pixel architecture design of the CIS which has wide dynamic range with a CMOS process (넓은 동적 범위를 가지는 CMOS Image Sensors OFD(Over Flow Drain) 픽셀 설계)

  • Kim, Jin-Su;Kwon, Bo-Min;Jung, Jin-Woo;Park, Ju-Hong;Kim, Jong-Min;Lee, Je-Won;Kim, Nam-Tae;Song, Han-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.77-85
    • /
    • 2009
  • We propose a new image pixel architecture which has OFD(Over Flow Device) node by improving conventional 3TR pixel structure. Newly designed pixel consists of photo diode which is verified with HSPICE simulation, PMOS reset transistor, several NMOS and several PMOS transistors. Photodiode signals from each PMOS and NMOS are detected by Reset PMOS. These output signals give enough chances to detect wide operation coverage because OFD node has overflow photocurrent. According to various light intensity, we analyzed characteristic of the output voltage with a SPICE tool. Proposed pixel output has specific value which can detect possible from $0.1{\mu}W/cm^2$ to $10W/cm^2$ light intensity. It has wide-dynamic range of 160 dB.

Characteristics of Plasma Plume with a Cylindrical Syringe Plasma Jet Device (원통형 바늘 구조의 플라즈마 제트 방출 특성)

  • Lim, H.K.;Jin, D.J.;Kim, J.H.;Han, S.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.1
    • /
    • pp.14-21
    • /
    • 2011
  • The plasma emission characteristics are investigated in cylindrical syringe plasma jet device. Cylindrical syringe electrode is applied AC power using inverter. In the center of syringe is injected into a inert gas and plasma jet occurs. If there is no ground electrode, firing voltage is 3 kV and plasma column length is 10 mm. According to high firing voltage and large current, the plasma column length control is difficult. The case of an internal ground electrode, firing voltage is 1 kV. Because of the losing current from internal ground, even if a higher input voltage, plasma emission does not occur. The case of an external ground electrode, the plasma column can be controlled between 0~10 mm with change the applied voltage from 1 to 2 kV, and the discharging current changed from 1 to 4 mA.

Improved Solubility and Characterization of Photovoltaic Properties D/A Copolymers based on Rigid Structure of Phenothiazine-Quinoxaline (Rigid한 Phenothiazine-Quinoxaline D/A 공액 고분자 구조의 용해성 향상 연구 및 유기박막태양전지로의 특성 분석)

  • Seong, Ki-Ho;Yun, Dae-Hee;Park, Yong-Sung
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.415-424
    • /
    • 2014
  • In this study, two kinds of polymer (PPQX-2hdPTZ (P1), POPQX-2hdPTZ (P2)) were synthesised by Suzuki coupling reaction based on phenothiazine derivative as electron-donor and quinoxaline derivative as electron-acceptor. Microwave synthesis workstation was used to shorten the polymerization time and increase the degree of polymerization. The physical, thermal stability, optical and electrochemical properties of the synthesized polymer were confirmed. The thermal stability of two polymers was outstanding as the initial decomposition temperature was $323-328^{\circ}C$. And additional substituted alkoxy chain on P2 showed higher degree of polymerization. An analysis of electrochemical properties, all polymer had similar HOMO energy level values. Device was fabricated by ITO/PEDOT:PSS/active layer/$BaF_2$/Al structure and photovoltaic properties were confirmed. Each device has a different film thickness and the resulting change in PCE was confirmed. As a result the thinner thickness of the film showed a high efficiency ($PCE_{max}:P1=1.0%$, P2 = 1.1%).

A Study on the Status of Practical Application of Oral Hygiene Devices :with labor of the D heavy industries (D중공업 근로자의 구강위생용품 사용실태 조사)

  • Park, Hong-Ryurn
    • Journal of dental hygiene science
    • /
    • v.6 no.2
    • /
    • pp.93-99
    • /
    • 2006
  • This study was carried out to investigate practical application status of oral hygiene devices through making a survey of labor of the D industrial company-about carefully curing oral disease in home, the status of practical application of tooth brush, the status of practical application of fluoridated toothpaste, status of practical application of auxiliary oral hygiene devices, a motive use or unuse of auxiliary oral hygiene devices. 1. In home, carefully curing oral disease is dental caries(62.4%). 2. Status of practical application toothbrush showed the highest user ratio of mideum size(79.6%). 3. Showed the highest user ratio of horizontal plane toothbrush(73.5%). 4. Answerd don't take a prudent attitued in choice of fluoridated toothpaste(73.5%). 5. In the status of reconition of oral hygiene devices, showed the highest user ratio of eletric toothbrush(77.0%). 6. In the status of reconition of auxiliary oral hygiene devices, showed the highest user ratio of wooden wedge stimulator(89.4%)and gargle liquid(84.5%). In using of oral hygiene devices, showed the highest user ratio of electric toothbrush(13.3%), toohbrush for periodontal patients(2.7%). In using of auxiliary, wooden wedge stimulator (58.4%)and gargle liquid(41.2%). In effect using of oral hygiene devices showed the highest user ratio of denture brush(50.0%)and eletric toothbrush(43.3%), in effect using of auxiliary oral hygiene devices showed the highest user ratio of water pick(80.0%) and dental floss(75.8%). 6. A motive of the use auxiliary oral hygiene device is choice by oneself through TV, advertisement, public information(57.6%), and the reason-they don't use of auxiliary oral hygiene devicebecause of they don't know proper to them the kind of auxiliary oral hygiene device.

  • PDF

An Experimental Study on Pressure-resistant Performance of a Re-fillable LPG Cylinder (LPG 재충전 소형 용기의 내압성능에 관한 실험적 연구)

  • Yim, Sang-Sik;Jang, Kap-Man;Lee, Jin-Han
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.2
    • /
    • pp.16-20
    • /
    • 2014
  • In this paper, the performance of pressure-resistance is validated by experiment on LPG re-fillable cylinder which has increased demands for spreading of camp culture. Propane has increased suppliable requirements as fuel because of easily vaporizing effect of low boiling point. However, propane can be occurring safety problems inevitably by high vapor pressure. So, the priority is that safe cylinder should furnish in order to be circulated as safe fuel. LPG re-fillable cylinder for high pressure is tried to furnish internationally, that is restricted by safe issues. For these reasons, the pressurization and rupture are performed by using pressurizing device that is operated by hydraulic system. Also, this paper will offer rupturable characteristics comparing with vapor pressure of propane. This paper is expected as basis research for developing re-fillable cylinder and using standard for supplying them.

A Study on Long Range Image Monitoring and Tracking System Using Laser Range-Gate Method in Inclement Weather Conditions (악천후 상황에서 Laser Range-Gate 방식을 이용한 원거리 영상 감시 및 추적 시스템에 대한 연구)

  • Oh, Sung-Kwun;Yoo, Sung-Hoon;Ku, Kyong-Wan;Kim, Su-Chan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.257-263
    • /
    • 2013
  • In case of image observation equipments, CCTV for short distance visual field is usually installed and operated mostly as the means of crime-prevention. However, the extensive demand for monitoring problems in case of the increase in intelligent crimes and disasters has led to the necessity of the development of long-distance observation equipments embedded with Night View functions. In case of the Night View equipments, the relevant market is set up to be focused mostly on Thermal Observation Device(hereinafter, TOD), but some shortcomings such as the limitation of image visibility and excessive maintenance cost, etc. have actually caused the necessity of new long distance Night View equipment. Moreover there might follow lots of difficulties in long-distance visualization in the event that irregular reflection is generated by minute particles in the atmosphere such as fog, smog, and dust, etc. These factors are motivate the work presented in this study. Our study is aimed at the realization of Pulsed Laser Illuminator and newly proposed Range-Gated image acquisition technology. And also the implementation of Tracker for continuous trace of the objects of interest from the obtained sequence images.

Risk Management and Telecommunications Research for customers of the accident location (사고선박의 고객위치파악용 위험관리 통신연구)

  • Kwak, Eun-young;Park, Dea-woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.331-335
    • /
    • 2016
  • When a boating accident, such as a January number three, the customer's risk management issues emerged. Ships and accident risk in confined spaces such as risk management to locate the customer and dangers of probation is available. In this paper, aboard after consent to obtain information for customers to wrist to customers, webbing or portable device embedded in devices and Wireless sensor information Input was attached, disposable consumer information. Customer on board the ship setting for location analysis and positioning according to information communication protocol, ships, each customer's real-time location information on the screen, 3 the foundation of d customers on the floor Can be designed to inform. Threshold designed to reduce the error of the information to analyze the position in current position and errors. Also, to system attacks would control the situation of accident and emergency jaenanguk server with real-time information transmission of information outside the emergency during a disaster, search and Disaster relief to be possible.

  • PDF

Objective Analysis of the Set-up Error and Tumor Movement in Lung Cancer Patients using Electronic Portal Imaging Device (폐암 환자에서 Electronic Portal Imaging Device를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정)

  • Kim, Woo-Cheol;Chung, Eun-Ji;Lee, Chang-Geol;Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.69-76
    • /
    • 1996
  • Purpose : The aim of this study is to investigate the random and systematic errors and tumor movement using electronic portal imaging device in lung cancer patients for the adequate margin in the treatment planning of 3-dimensional conformal therapy. Material and Methods : The electronic portal imaging device is matrix ion chamber type(Portal Vision, Varian). Ten patients of lung cancer treated with chest irradiation were selected for this study. Patients were treated in the supine position without immobilization device. All treatments were delivered by an 10 MV linear accelerator that had the portal imaging system mounted to its ganrty. AP or PA field Portal images were only analyzed. Radiation therapy field included the tumor, mediastinum and supraclavicular lymph nodes. A total of 103 portal images were analyzed for set-up deviation and 10 multiple images were analyzed for tumor movement because of respiration and cardiac motion. Result : The average values of setup displacements in the x, y direction was 1.41 mm, 1 78 mm, respectively. The standard deviation of systematic component was 4.63 mm, 4.11 mm along the x, y axis, respectively while the random component was 4.17 mm in the x direction and 3.31 mm in the y direction. The average displacement from respiratory movement was 12.2 mm with a standard deviation of 4.03 mm. Conclusion : The overall set-up displacement includes both random and systematic component and respiratory movement. About 10 mm, 25 mm margins along x, y axis which considered the set-up displacement and tumor movement were required for initial 3-dimensional conformal treatment planning in the lung cancer patients and portal images should be made and analyzed during first week of treatment, individually.

  • PDF