• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.028 seconds

2D Transconductance to Drain Current Ratio Modeling of Dual Material Surrounding Gate Nanoscale SOl MOSFETs

  • Balamurugan, N.B.;Sankaranarayanan, K.;John, M.Fathima
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.2
    • /
    • pp.110-116
    • /
    • 2009
  • The prominent advantages of Dual Material Surrounding Gate (DMSG) MOSFETs are higher speed, higher current drive, lower power consumption, enhanced short channel immunity and increased packing density, thus promising new opportunities for scaling and advanced design. In this Paper, we present Transconductance-to-drain current ratio and electric field distribution model for dual material surrounding gate (DMSGTs) MOSFETs. Transconductance-to-drain current ratio is a better criterion to access the performance of a device than the transconductance. This proposed model offers the basic designing guidance for dual material surrounding gate MOSFETs.

Design of Current-Type Readout Integrated Circuit for 160 × 120 Pixel Array Applications

  • Jung, Eun-Sik;Bae, Young-Seok;Sung, Man-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.221-224
    • /
    • 2012
  • We propose a Readout Integrated Circuit (ROIC), which applies a fixed current bias sensing method to the input stage in order to simplify the circuit structure and the infrared sensor characteristic control. For the sample-and-hold stage to display and control a signal detected by the infrared sensor using a two-dimensional (2D) focal plane array, a differential delta sampling (DDS) circuit is proposed, which effectively removes the FPN. In addition, the output characteristic is improved to have wider bandwidth and higher gain by applying a two-stage variable gain amplifier (VGA). The output characteristic of the proposed device was 23.91 mV/$^{\circ}C$, and the linearity error rate was less than 0.22%. After checking the performance of the ROIC using HSPICE simulation, the chip was manufactured and measured using the SMIC 0.35 um standard CMOS process to confirm that the simulation results from the actual design are in good agreement with the measurement results.

Ultrahigh-Resolution Spectral Domain Optical Coherence Tomography Based on a Linear-Wavenumber Spectrometer

  • Lee, Sang-Won;Kang, Heesung;Park, Joo Hyun;Lee, Tae Geol;Lee, Eun Seong;Lee, Jae Yong
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.55-62
    • /
    • 2015
  • In this study we demonstrate ultrahigh-resolution spectral domain optical coherence tomography (UHR SD-OCT) with a linear-wavenumber (k) spectrometer, to accelerate signal processing and to display two-dimensional (2-D) images in real time. First, we performed a numerical simulation to find the optimal parameters for the linear-k spectrometer to achieve ultrahigh axial resolution, such as the number of grooves in a grating, the material for a dispersive prism, and the rotational angle between the grating and the dispersive prism. We found that a grating with 1200 grooves and an F2 equilateral prism at a rotational angle of $26.07^{\circ}$, in combination with a lens of focal length 85.1 mm, are suitable for UHR SD-OCT with the imaging depth range (limited by spectrometer resolution) set at 2.0 mm. As guided by the simulation results, we constructed the linear-k spectrometer needed to implement a UHR SD-OCT. The actual imaging depth range was measured to be approximately 2.1 mm, and axial resolution of $3.8{\mu}m$ in air was achieved, corresponding to $2.8{\mu}m$ in tissue (n = 1.35). The sensitivity was -91 dB with -10 dB roll-off at 1.5 mm depth. We demonstrated a 128.2 fps acquisition rate for OCT images with 800 lines/frame, by taking advantage of NVIDIA's compute unified device architecture (CUDA) technology, which allowed for real-time signal processing compatible with the speed of the spectrometer's data acquisition.

60 GHz Optical Carrier Generator using Quasi-Velocity-Matching Technique (Quasi-Velocity-Matching물 이용한 60 GHz 광캐리어 발생기)

  • Kim, W.K.;Yang, W.S.;Lee, H.M.;Lee, H.Y.;Jeong, W.J.;Kwon, S.W.
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.181-185
    • /
    • 2006
  • A novel 60GHz optical carrier generator with a polarization domain-inverted structure is suggested and is demonstrated. The two arms of the Mach-Zehnder optical waveguide are periodically poled for quasi-phase velocity matching between the optical wave at 1550nm and the RF wave at 30 GHz. The center frequency of band-pass modulation and the 3 dB bandwidth of the fabricated modulator were measured to be 30.3 GHz and 5.1 GHz, respectively. Sub-carriers with the frequency difference of 60GHz waeregenerated under appropriate DC biac voltage application while the carrier was suppressed to lead to the power ratio between the modulated sub-carrier and the suppressed fundamental carrier of 28 dB, which proves that double sideband- suppressed carrier(DSB-SC) operation can be realized by the suggested single device.

Analysis of Electromagnetic Wave Characteristics of Microwave Nondestructive Device for Inspecting Human Lower Leg (마이크로파 비파괴 검사를 위한 인체 하지에 대한 전자파특성 분석)

  • Kim, Byung-Mun;Lee, Sang-Min;Park, Young-Ja;Hong, Jae-Pyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.2
    • /
    • pp.385-394
    • /
    • 2021
  • In this paper, a new equation of electromagnetic wave transmission matrix was proposed to calculate the reflected power and transmitted power for the multi-layered planar lossy structure. The applied human leg was modeled as a four-layer planar structure of skin, fat, muscle and bone. The complex dielectric constant to consider the loss of each of these layers was calculated using the 4-pole cole-cole model parameter. When electromagnetic waves were incident on the skin surface, total reflected and transmitted power, and human body loss were calculated for a frequency band of 0.1 to 20.0 GHz. And for various muscle thicknesses, the power reflected only from the outermost bone and re-radiated from the skin was calculated. It was confirmed that at the muscle thickness of 3.0 mm and the frequency of 4.6 GHz the return loss was -6.13 dB, which was 3.42 dB lower than the average value.

Design of a 2kW Bidirectional Synchronous DC-DC Converter for Battery Energy Storage System (배터리 에너지 저장장치용 고효율 2kW급 양방향 DC-DC 컨버터 설계)

  • Lee, Taeyeong;Cho, Byung-Geuk;Cho, Younghoon;Hong, Chanook;Lee, Han-Sol;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.312-323
    • /
    • 2017
  • This paper introduces the bidirectional dc-dc converter design case study, which employs silicon-carbide (SiC) MOSFETs for battery energy storage system (BESS). This converter topology is selected as bidirectional synchronous buck converter, which is composed of a half bridge converter, an inductor, and a capacitor, where the converter has less conduction loss than that of a unidirectional buck and boost converter, and to improve the converter efficiency, both the power stage design and power conversion architecture are described in detail. The conduction and switching losses are compared among three different SiC devices in this paper. In addition, the thermal analysis using Maxwell software of each switching device supports the loss analyses, in which both the 2 kW prototype analyses and experimental results show very good agreement.

A Novel Transflective Homogeneously Aligned Liquid Crystal Display Driven by Fringe-Field (Fringe-Field 구동형 새로운 반투과형 수평 배향 액정 디스플레이)

  • 정태봉;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.6
    • /
    • pp.501-509
    • /
    • 2003
  • We have designed transflective liquid crystal display(LCD) associated with in-plane switching of a LC director driven by fringe-field, unlike other LCD mode. Reflective area consists of a λ/2 compensation film and a LC cell with retardation value(dΔn) of λ/4 with their optic axes making an angle of 15$^{\circ}$ and 75$^{\circ}$ against polarizer, respectively. In the transmissive area, top and bottom polarizers are parallel each other, an LC has a dΔn of λ/2, and another λ/2 compensation film is inserted between the LC cell and bottom polarizer. With the configuration, both devices show dark state initially. When an incident light is 550nm, the device shows wide-viewing-angle characteristics such that in the reflective area the contrast ratio target than 5 exists up to 55$^{\circ}$ of polar angle in all directions and in transmissive area it exists about 100$^{\circ}$ in vortical direction and 110$^{\circ}$ in horizontal direction.

Development of an Augmented Reality Puzzle Game Detecting Hand Posture Using HSV Color Space in Real Time (HSV 컬러 영역을 이용한 실시간 손동작 검출 증강현실 퍼즐 게임 개발)

  • Kim, Minhyuk;Kim, Youngsik
    • Journal of Korea Game Society
    • /
    • v.14 no.5
    • /
    • pp.79-86
    • /
    • 2014
  • There have been many trials for development of games using augmented reality. This paper presents a 2D puzzle game system using HSV color space to detect hand posture from an input image by smart device's cameras in real time. The developed game in this paper brings smart devices and the computer vision closer. Also this game can be a new interactive technology utilizing both the mobility of smart devices and the tangible interactivity of virtual reality in education and entertainment environments.

A Study on the Insertional Coil of MRI Device for Diagnosis (진단용 자기공명영상장치의 삽입 코일에 관한 연구)

  • Lee, Yong-Moon;Lim, Keun-Ho;Seo, Dae-Keon;Kim, Wang-Gon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05d
    • /
    • pp.33-37
    • /
    • 2003
  • Endovaginal and endorectal receiver only surface coil were designed for MR imaging(MRI) and $^1H$ MR spectroscopy(MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round comer. The shape of endorectal coil wire was long elliptic shape during insertion and circular shape after insertion. Conventional spin echo and fast spin echo sequences were used as T1 and T2 weighted imaging sequences, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method. Using home-built endvaginal and endorectal coils, excellent T1 and T2 images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo $^1H$ MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF

Development of Wave Power Generator using Horizontal Motions of the Wave (파랑의 수평운동을 이용한 파력발전장치 개발)

  • Hwang, S.S.;Park, I.H.;Lee, D.S.;Yang, K.U.
    • Journal of Drive and Control
    • /
    • v.12 no.2
    • /
    • pp.7-13
    • /
    • 2015
  • In this study, we suggested the wave power generator using horizontal motions of the wave for use in the coastal sea. The length of the horizontal movement of the wave in the vicinity of the sea surface is larger than the length of the vertical reciprocating movement of the wave, hence the proposed device has a wave power transmission plate. In addition, because the motion of the wave is maximum to the sea surface, by arranging the buoyancy tanks at the top of the wave power transmission plate, it is always capable of vertical movement in accordance with the sea surface. To confirm the usefulness of the proposed wave power generator, we constructed a mathematical model of the wave power generator and carried out simulation using bondgraph. Furthermore, the efficiency was verified by measuring the degree of electrical energy production through a preliminary experiment.