• Title/Summary/Keyword: Device Profile

Search Result 423, Processing Time 0.024 seconds

A study on the Normal Steady State Operation Characteristics of PV System Based on the Test Device (태양광전원용 시험장치를 이용한 정상상태 운용특성에 관한 연구)

  • Hasan, Md.Mubdiul;Munkbaht, Munkbaht;Kim, Byung-Ki;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.512-516
    • /
    • 2012
  • Recently the Korean government's green energy growth policy has been taken at the national level due to the sufficient supply of renewable energy. Some specific technique should be taken in consideration for the operation of the grid voltage and power quality management. In this case, there may have some chance of operational problems. Typical problems arise when grid-connected solar power produced by Pacific sunshine. The power flow in the reverse direction can create overvoltage on the distribution line and gives value of malfunction on the system. Line voltage and overvoltage adjustment practice can stop these symptoms occurred. Under these circumstances, this paper presents an interconnection test devices for photovoltaic(PV) systems composed of distribution system simulator, PV system simulator and control and monitoring systems using the LabVIEW S/W, and simulates the customer voltage characteristics considering the 3 parameters on the introduction capacity for PV systems, system configuration and Power factor. This paper also proposes a new calculation algorithm for voltage profile to make comparison between calculation values and test device values. The results show that the simulation results for the normal operation characteristics of PV systems which are very practical and effective.

  • PDF

Preparation of Biodegradable PHBV Devices Containing Gentamicin Sulfate (PHBV를 이용한 황산겐타마이신 서방성 제형의 제조와 방출거동)

  • 최학수;김상욱;윤덕일;강길선;이종문;김용식;이해방
    • Polymer(Korea)
    • /
    • v.25 no.3
    • /
    • pp.334-342
    • /
    • 2001
  • Gentamicin sulfate (GS)-loaded poly(3-hydroxybutyrate-co-3-hydroxyvalerate)(PHBV) devices were prepared for controlled-release of antibiotics. In this study, the effects of thickness, hydroxyvalerate (HV) content, initial drug-loading ratio, and additive content on the release profile have been investigated. The morphology of devices was examined with scanning electron microscope (SEM) before and after in vitro release; their highly porous surface and cross-sectional were observed. It could be suggested that device would be affected by the packing of the HV and additive content, which would depend on their structure. A high performance liquid chromatography (HPLC) was used to detect and quantify the release of GS from the device. The drug release from all the devices showed biphasic release patterns, and some matrices released the incorporated antibiotic throughout 30 days with a near zero-order release rate. The release patterns were shown to be changed by altering the thickness, copolymer ratio, and additive content.

  • PDF

A Study on Optimal Design of 100 V Class Super-junction Trench MOSFET (비균일 100V 급 초접합 트랜치 MOSFET 최적화 설계 연구)

  • Lho, Young Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.109-114
    • /
    • 2013
  • Power MOSFET (metal-oxide semiconductor field-effect transistor) are widely used in power electronics applications, such as BLDC (Brushless Direct Current) motor and power module, etc. For the conventional power MOSFET device structure, there exists a tradeoff relationship between specific on-state resistance and breakdown voltage. In order to overcome the tradeoff relationship, a non-uniform super-junction (SJ) trench MOSFET (TMOSFET) structure for an optimal design is proposed in this paper. It is required that the specific on-resistance of non-uniform SJ TMOSFET is less than that of uniform SJ TMOSFET under the same breakdown voltage. The idea with a linearly graded doping profile is proposed to achieve a much better electric field distribution in the drift region. The structure modelling of a unit cell, the characteristic analyses for doping density, and potential distribution are simulated by using of the SILVACO TCAD 2D device simulator, Atlas. As a result, the non-uniform SJ TMOSFET shows the better performance than the uniform SJ TMOSFET in the specific on-resistance at the class of 100V.

Development and Implementation of a Skill Transfer System for a Self-Tapping Screw-Tightening Operation

  • Matsumoto, Toshiyuki;Doyo, Daisuke;Shida, Keisuke;Kanazawa, Takashi
    • Industrial Engineering and Management Systems
    • /
    • v.10 no.3
    • /
    • pp.209-220
    • /
    • 2011
  • Self-tapping screws have some operational peculiarities. In spite of their economical advantage that requires no prior tapping operation, a weakness of self-tapping screw-tightening operations is that screws can easily be tightened at a non-right angle, thus resulting in an improper tightening strength. Increases in outsourced workers have reduced labor costs, but the accompanying high worker fluidity means that new workers are more frequently introduced into factories. It is necessary to train new workers for self-tapping screw-tightening operations, which occupies a considerable portion of ordinary assembly works. The purpose of this study is to develop and implement a skill transfer system for the operation. This study (1) proposes a set of characteristic values for evaluating the quality of the operation and develops a device that can measure these values; (2) proposes criteria for evaluating the resultant quality of the tightening; and (3) develops a skill training system for better work performance. Firstly, sets of characteristic values for evaluating the quality of the operation, namely, torque, vertical pressure forces and horizontal vibration forces, are proposed. A device that can measure these values is developed. Secondly, criteria for evaluating the resultant quality of the tightening are identified, involving tightening torque, maximum vertical pressure and timing, vibration area during the processing and tightening period, and work angle. By using such parameters, workers with the proper aptitude can be identified. Thirdly, a skill training system for the operation is developed. It consists of screwdriver operation training and screw-tightening training with feedback information about the results of the operation. Finally, the validity of the training system is experimentally verified using new operators and actual workers.

Implementation of Personalized Music Recommendation System using Time-weighting in Mobile Environment (모바일 환경에서 시간에 따른 가중치 부여를 이용한 개인화된 음악 추천 서비스)

  • Park, Won Ik;Kang, Sang Kil
    • Journal of Information Technology and Architecture
    • /
    • v.10 no.2
    • /
    • pp.251-261
    • /
    • 2013
  • The appearance of various mobile Internet environment access to existing networks of mobile devices is easier to tell. In addition, mobile device users to use the wireless environment than a wired environment, user profile information is readily available features. Mobile devices have features that use alone. These characteristics of mobile devices to apply the personalization service is the best system. This paper proposes for mobile device users a personalized mobile music content recommendation service. This service propose to utilizes the user's access history information using time-weighting and collaborative filtering. Access history information can find out information of user interest. Using this information, consider the preference of music genre and time-weighted based on the recommendations makes the music. This method the problem of the traditional music recommendation system, point user's favorite music genre is changing over time do not consider that to solve the problem.

Basic Dose Response of Fluorescent Screen-based Portal Imaging Device (섬광판을 사용하는 조사문영상기구의 기본적인 선량반응성)

  • Yeo, In-Hwan J.;Yohannes, Yonas;Zhu,Yunping
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.249-255
    • /
    • 1999
  • Purpose : The purpose of this study is to investigate fundamental aspects of the dose response of fluorescent screen-based electronic portal imaging devices (EPIDS). Materials and Methods : We acquired scanned signal across portal planes as we varied the radiation that entered the EPID by changing the thickness and anatomy of the phantom as well as the air gap between the phantom and the EPID. In addition, we simulated the relative contribution of the scintillation light signal in the EPID system. Results : We have shown that the dose profile across portal planes is a function of the air gap and phantom thickness. We have also found that depending on the density change within the phantom geometry, errors associated with dose response based on the EPID scan can be as high as $7\%$. We also found that scintillation light scattering within the EPID system is an important source of error. Conclusion : This study revealed and demonstrated fundamental characteristics of dose response of EPID, as relative to that of ion chambers. This study showed that EPID based on fluorescent screen cannot be an accurate dosimetry system.

  • PDF

Design of Variable Optical Attenuators Incorporating Large Core Polymer Waveguides (대형 코어 폴리머 광도파로를 이용한 가변 광감쇠기 설계)

  • Cho, Su-Hong;Oh, Min-Choel
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.254-260
    • /
    • 2005
  • By incorporating large core polymer waveguides, which have been developed for increased alignment tolerance in passive fiber attachment, highly efficient variable optical attenuators are proposed. In order to find optimum device structures, 3-dimensional beam propagation method (BPM) simulations are performed. Heat distribution over the polymer film is calculated to find the 3-dimensional index profile data for the BPM simulation. Due to the small index contrast between the core and cladding materials in the large core waveguide, heat-induced radiation occurs for small heating power. While the ordinary VOA needs the temperature to change over $150^{\circ}C$ for 20 dB attenuation, the large core VOA requires only $70^{\circ}C$. In addition to the merit of passive fiber attachment, the proposed VOA has enhanced attenuation efficiency for the lower temperature change.

Application of Pulsed Plasmas for Nanoscale Etching of Semiconductor Devices : A Review (나노 반도체 소자를 위한 펄스 플라즈마 식각 기술)

  • Yang, Kyung Chae;Park, Sung Woo;Shin, Tae Ho;Yeom, Geun Young
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.6
    • /
    • pp.360-370
    • /
    • 2015
  • As the size of the semiconductor devices shrinks to nanometer scale, the importance of plasma etching process to the fabrication of nanometer scale semiconductor devices is increasing further and further. But for the nanoscale devices, conventional plasma etching technique is extremely difficult to meet the requirement of the device fabrication, therefore, other etching techniques such as use of multi frequency plasma, source/bias/gas pulsing, etc. are investigated to meet the etching target. Until today, various pulsing techniques including pulsed plasma source and/or pulse-biased plasma etching have been tested on various materials. In this review, the experimental/theoretical studies of pulsed plasmas during the nanoscale plasma etching on etch profile, etch selectivity, uniformity, etc. have been summarized. Especially, the researches of pulsed plasma on the etching of silicon, $SiO_2$, and magnetic materials in the semiconductor industry for further device scaling have been discussed. Those results demonstrated the importance of pulse plasma on the pattern control for achieving the best performance. Although some of the pulsing mechanism is not well established, it is believed that this review will give a certain understanding on the pulsed plasma techniques.

The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Casting Gold Removal in Vitro (큐렛팁을 장착한 압전방식 초음파치석제거기의 작업조건에 따른 치과주조용 합금의 삭제에 관한 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.3
    • /
    • pp.531-542
    • /
    • 2001
  • Periodontal debridement is most important procedure in periodontal treatment, because periodontal disease is the biofilm infection. The use of ultrasonic instrument has many clinical advantages compared to classical hand instrument. The introduction of newly developed ultrasonic scaler tips made the use of ultrasonic scaler popular. However the study of tooth substance removal according to the working parameters of ultrasonic scaler with newly developed tips is not sufficient. The purpose of this study is to evaluate the effects of working parameters of piezoelectric ultrasonic scaler with curette tip on casting gold removal. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1.0 N, 2.0 N) and power setting was adjusted 2, 4, 8 in P mode and S mode and instrumentation time was 5 seconds. The defect depth and width were measured with profile meter and defect surface was examined by SME. The depth of defect was significantly large in S mode( $39.58{\pm}19.35{\mu}m$) compared to P mode( $8.37{\pm}6.98{\mu}m$). There was significant decrease of depth of defect between 1.0N($32.87{\pm}27.18{\mu}m$) and 2.0N( $14.86{\pm}15.04{\mu}m$). The area of defect was also significantly large in S mode($4482.42{\pm}3551.71{\mu}m^2$) compared to P mode( $922.06{\pm}960.32{\mu}m^2$). There was significant decrease of area of defect between 1.0N($3889.12{\pm}3936.00{\mu}m$) and 2.0N( $974.66{\pm}986.01{\mu}m$). The change of mode did not effect on the width of the defect. The change of power setting did not effect on the depth, width, and area of defect. In spite of limitation of this study it could be concluded that the use of piezoelectric ultrasonic scaler with curette tip on S mode could make significant tooth substance loss.

  • PDF

Studies on the properties of electrochromic films and the effect of migration barrier (Electrochromic 막의 특성과 물질이동 방지막의 효과에 대한 연구)

  • 황하룡;백지흠;허증수;이덕동;임정옥;장동식
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.3
    • /
    • pp.221-226
    • /
    • 2000
  • After manufacturing the electrochromic device (structure: ITO glass/$WO_3$/electrolyte/$V_2O_5$/ITO;glass) by using of sol-gel process and evaporation, optical properties and migration effect were investigated. The result shows that electrochromic device with heat treated (at water vapor ambient, $500^{\circ}C$, 1 hour) sol-gel coated $WO_3$ and $V_2O_5$ films had the highest transmittance variance. Electrochromic devices are based on the reversible insertion of guest atoms into structure of the host solid. But after cyclic operation, we find that the tungsten in $WO_3$ film and the indium in ITO film were migrated with each other. For the purpose of blocking migration, tungsten barrier film is inserted between ITO and $WO_3$ film. The result of cyclic voltamogram and the Auger depth profile show that the peak separation of cyclic voltamogram is reduced to below 1/10 and we could effectively block the indium and tungsten migration that is caused by flow of Li ions.

  • PDF