Analysis on SFCL's Impedance for Protective Coordination in Large Transformer installed in Distribution Substation (배전변전소에 대용량변압기로 교체 적용시 보호협조를 위한 초전도 전류제한기의 임피던스 분석)

  • Kim, Jin-Seok;Kim, Myoung-Hoo;You, Il-Kyoung;Moon, Jong-Fil;Lim, Sung-Hun;Kim, Jae-Chul;Ahn, Jae-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1479-1484
    • /
    • 2009
  • The introduction of the large transformer due to the large power demand has increased the fault current in power distribution system. The increased fault current can exceed the cut-off ratings of the circuit breaker. As the methods to solve this problem, the superconducting fault current limiter(SFCL) has been notified. However, the limited fault current by SFCL affects the operational characteristics of the protective device such as overcurrent relay. Therefore, the selection of the proper impedance for the SFCL is required to keep overcurrent relay's protective coordination with the SFCL when a large transformer is introduced into the distribution system. In this paper, the SFCL's impedance for protective coordination was investigates in that a large transformer is introduced.

Protection Coordination Strategy of Microgrid Demonstration Site (마이크로그리드 실증사이트의 보호협조 전략)

  • Jin, Dae-Geun;Choi, Won-Jun;Won, Dong-Jun;Lee, Hak-Ju;Chae, Woo-Kyu;Park, Jung-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.966-973
    • /
    • 2012
  • In microgrid demonstration site, distributed generations can make bidirectional power flows on the system. If an accident occurs, the fault current from the inverter based distributed generation is small. However, the conventional protection scheme in distribution network is designed to operate at high fault current. This means that the traditional protection of distribution network is no longer applicable and new protection methods must be developed. In this paper, for two cases, algorithms for protection coordination of demonstration site is proposed and verified through PSCAD/EMTDC simulation. In first case, protection devices are assumed to have the abilities of directional relaying and communication. In second case, protection devices do not have those abilities. Proposed protection coordination algorithms detect the fault locations and protect the microgrid fairly well.

Energy Coordination between Cascaded Voltage Limiting Type SPDs in Surge Currents due to Direct Lightning Flashes (종속 접속된 전압제한형 SPD의 직격뢰 서지전류에 대한 에너지협조)

  • Lee, Bok-Hee;Um, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.68-75
    • /
    • 2014
  • Cascaded applications of surge protective devices(SPDs) are required in order to reduce the stress on the electrical and electronics equipment being protected, and the energy coordination between the cascaded SPDs is very important. This paper deals with the experimental results obtained from the installation conditions of full-scale SPDs. The energy coordination between the upstream Class I SPD and the downstream Class II SPD was measured using a $10/350{\mu}s$ impulse current due to direct lightning flashes. The distances between the cascaded SPDs were 3, 10, and 50m, and the maximum test current was 12.5kA. As a result, the energy sharing between cascaded SPDs was dependent on the voltage protection level of each SPD and the distance between two SPDs. An overview of how to select SPD ratings in applications of cascaded SPDs system was discussed based on the energy coordination between the two SPDs. The proposed test results for the energy coordination between two-stage cascaded SPDs can be used in effective applications of SPDs.

An Accurate Model of Multi-Type Overcurrent Protective Devices Using Eigensystem Realization Algorithm and Practice Applications

  • Cheng, Chao-Yuan;Wu, Feng-Jih
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.9-19
    • /
    • 2016
  • Accurate models of the characteristics of typical inverse-time overcurrent (OC) protective devices play an important role in the protective coordination schemes. This paper presents a novel approach to determine the OC protective device parameters. The approach is based on the Eigensystem Realization Algorithm which generates a state space model to fit the characteristics of OC protective devices. Instead of the conventional characteristic curves, the dynamic state space model gives a more exact fit of the OC protective device characteristics. This paper demonstrates the feasibility of decomposing the characteristic curve into smooth components and oscillation components. 19 characteristic curves from 13 typical and 6 non-typical OC protective devices are chosen for curve-fitting. The numbers of fitting components required are determined by the maximum absolute values of errors for the fitted equation. All fitted equations are replaced by a versatile equation for the characteristics of OC protective devices which represents the characteristic model of a novel flexible OC relay, which in turn may be applied to improve the OC coordination problems in the sub-transmission and distribution systems.

Coordination of Cascaded Metal Oxide Varistor-Based Surge Protective Devices (종속 접속된 산화아연바리스터 기반의 서지방호장치의 협조)

  • Kim, Tae-Ki;Shin, Hee-Kyung;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.70-77
    • /
    • 2015
  • This paper describes the experimental results obtained from various installation conditions of cascaded metal oxide varistor(MOV)-based SPDs with the objectives to analyze the coordination of the cascaded surge protective devices(SPDs) and to propose the proper selection and installation methods of the cascaded SPDs. The residual voltage, discharge current and energy sharing between the upstream and downstream SPDs in the $10/350{\mu}s$ direct lightning current wave were measured and discussed. The coordination of cascaded MOV-based SPDs is closely related to the varistor voltage and installation methods of SPDs. In cascaded SPDs without dedicated decoupling elements, the natural impedance of leads connecting two SPDs can act as a decoupler for the coordination of MOV-based SPDs. Even if the varistor voltage of the upstream SPD is higher than that of the downstream SPD at long distances between two SPDs, the energy coordination of cascaded SPDs could effectively be fulfilled in the conditions of large surge currents and the optimum voltage protection level can be achieved. Consequently, if the distance between voltage limiting type SPDs is long, the coordination of the cascaded SPDs should be determined by taking into account the decoupling effects due to the intrinsic inductance of leads connecting the upstream and downstream SPDs.

Interference Coordination for Device-to-Device (D2D) under Multi-channel of Cellular Networks

  • Zulkifli, Aunee Azrina;Huynh, Thong;Kuroda, Kaori;Hasegawa, Mikio
    • Journal of Multimedia Information System
    • /
    • v.3 no.4
    • /
    • pp.135-140
    • /
    • 2016
  • To improve the throughput of Device-to-Device (D2D) communication, we focus on the scenario where D2D pair can reuse multi-channel of cellular communication. However, as sharing same channel with cellular communication can cause interference between D2D communication and cellular communication, a proper interference management is needed. In this paper, we propose interference-based channel allocation to select the channels to be used by D2D communication and a solution from game theory perspective to optimize the D2D communication throughput under multi-channel as well as guarantee the interference from it to cellular network. The simulation results verify the stability of the proposed method.

Coordination between Voltage-Limiting Surge Protective Devices in Surge Currents Caused by Direct Lightning Flashes

  • Shin, Hee-Kyung;Lee, Jae-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.116-125
    • /
    • 2015
  • This paper presents experimental results obtained from actual installation conditions of surge protective devices (SPDs), with the aim of understanding the coordination of cascaded Class I and Class II SPDs. This paper also proposes effective methods for selecting and installing coordinating cascaded SPDs. The residual voltage of each SPD and the energy sharing of an upstream Class I tested SPD and a downstream Class II tested SPD were measured using a $10/350{\mu}s$ current wave. In coordinating a cascaded voltage-limiting SPD system, it was found that energy coordination can be achieved as long as the downstream SPD is a metal oxide varistor with a higher maximum continuous operating voltage than the upstream SPD; however, it is not the optimal condition for the voltage protection level. If the varistor voltage of the downstream SPD is equal to or lower than that of the upstream SPD, the precise voltage protection level is obtained. However, this may cause serious problems with regard to energy sharing. The coordination for energy sharing and voltage protection level is fairly achieved when the cascaded SPD system consists of two voltage-limiting SPDs separated by 3 m and with the same varistor voltage.

Development of a Washout Algorithm for a Vehicle Driving Simulator Using New Tilt Coordination and Return Mode

  • You Ki Sung;Lee Min Cheol;Kang Eugene;Yoo Wan Suk
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.spc1
    • /
    • pp.272-282
    • /
    • 2005
  • A vehicle driving simulator is a virtual reality device which makes a man feel as if he drove an actual vehicle. Unlike actual vehicles, the simulator has limited kinematical workspace and bounded dynamic characteristics. So it is difficult to simulate dynamic motions of a multi-body vehicle model. In order to overcome these problems, a washout algorithm which controls the workspace of the simulator within the kinematical limitation is needed. However, a classical washout algorithm contains several problems such as generation of wrong sensation of motions by filters in tilt coordination, requirement of trial and error method in selecting the proper cut-off frequencies and difficulty in returning the simulator to its origin using only high pass filters. This paper proposes a washout algorithm with new tilt coordination method which gives more accurate sensations to drivers. To reduce the time in returning the simulator to its origin, an algorithm that applies selectively onset mode from high pass filters and return mode from error functions is proposed. As a result of this study, the results of the proposed algorithm are compared with the results of classical washout algorithm through the human perception models. Also, the performance of the suggested algorithm is evaluated by using human perception and sensibility of some drivers through experiments.

A study of coordination under short-circuit conditions between circuit-breakers (저압차단기의 차단보호협조 특성연구)

  • Oh, J.S.;Na, C.B.;Ham, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.476-478
    • /
    • 2001
  • Coordination under short-circuit conditions is a systematic application of protective devices in the electrical power system, which, in response to a fault, will remove only a minimum amount of equipment from service. The objective is not only to minimize the equipment damage and process outage costs, but also to protect personnel from the effects of these failures. The coordination study of an electric power system consists of an organizes time-current study of all devices in series from the utilization device to the source. This study is a comparison of the time it takes the individual devices to operate when certain levels of normal or abnormal current pass through the protective devices. The objective of a coordination study is to determine the characteristics, ratings, and settings of overcurrent protective devices that will ensure that the minimum unfaulted load is interrupted when the protective devices isolate a fault or overload anywhere in the system. At the same time, the devices and settings selected should provide satisfactory protection against overloads on the equipment and interrupt short-circuit as rapidly as possible.

  • PDF

Improved Coordination Method for Back-up Protection Schemes Based on IEC 61850 (IEC 61850 기반 후비보호계전시스템 보호협조 개선방안)

  • Kim, Hyung-Kyu;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.43-49
    • /
    • 2011
  • A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome this problem clearly, this paper describes an improved backup protection coordination scheme using an IEC 61850-based distance relay for transformer backup protection. IEC 61850-based IED(Intelligent Electronic Device) and the network system based on the kernel 2.6 LINUX are realized to verify the proposed method. And laboratory tests to estimate the communication time show that the proposed coordination method is reliable enough for the improved backup protection scheme.