• Title/Summary/Keyword: Deterioration facilities

Search Result 255, Processing Time 0.031 seconds

A Study on Risk Evaluation Method of Ground Subsidence around Sewer (하수관로 주변 도로함몰 위험도 평가 방법에 관한 연구)

  • Kim, Jinyoung;Choi, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.7
    • /
    • pp.13-18
    • /
    • 2018
  • Recently, road subsidence has been increasing in urban areas, threatening the safety of citizens. In the lower part of the road, various road facilities such as water supply and drainage pipelines and telecommunication facilities are buried, and the deterioration of the facilities causes the road subsidence. In particular, in the case of old sewer pipes which are attracting attention as a main cause of road subsidence, the management of sewer pipe replacement, repair and reinforcement is being performed depending on the burial year. Therefore, in this study, we tried to suggest a reliable road subsidence risk assessment method considering various sewer specifications and surrounding environment information and CCTV exploration result and GPR exploration result.

A Study on Activation methods of Traditional Market in Jinju City -Focused on Joongang and Seobu Market- (진주시 전통시장 개선방안 연구 -중앙시장과 서부시장을 중심으로-)

  • Kang, Seok-Jin
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • The purpose of this study is to consider activation methods of traditional markets in Jinju city through questionnaire and field survey. Research framework is summarized into two categories: physical environment and operation program. The results are as follows: 1) the gross profit on sales has been decreased continuously and the main causes of that have been recognized as insufficiency of parking lots and convenient facilities and deterioration of environment in spite of facilities modernization project; 2) consumers visited a traditional market because of proper price and reliance on goods, etc. However, they were not satisfied with the physical environment such as parking lots and resting spaces and the operation program such as cultural event and performance. In conclusion it was thought that activation methods of traditional market would be related to the improvement plan in the physical aspect such as parking lots, walkway, convenient and crime prevention facilities and in the operation program aspect such as cultural event, marketing, management consulting, information infrastructure, and delivery system.

A Study on the Multiplex Use of Elementary School Facilities for Revitalizing Local Communities (지역 커뮤니티 활성화를 위한 초등학교시설 복합화 방안에 관한 연구)

  • Lee, Si-Won;Chu, Beom
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.23 no.2
    • /
    • pp.11-22
    • /
    • 2024
  • Rapid urbanization has led to the decline of local communities in old city centers and the deterioration of school facilities, resulting in an increased need for school complexes. School complexes are currently growing, with various policies being proposed. However, integrating additional facilities into the existing infrastructure in schools can lead to a range of issues. To mitigate these issues, additional traffic flow paths and complex integration strategies are required. This study categorizes school complex projects into various types based on themes and examines the relationships between each type and community revitalization factors. Through this analysis, the study recommends desirable directions for the implementation of elementary school complex projects to revitalize local communities.

The Ultraviolet Generation Characteristics of porcelain and Polymer Insulators by Corona Discharge (코로나 방전에 의한 자기 및 폴리머 애자의 자외선 발생특성)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Kim, Young-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.147-152
    • /
    • 2008
  • This paper describes the breakdown poperties of porcelain and polymer insulators using the UV camera. The experiment was carried out using condition of voltage at the KS C IEC 60060-1(2006). As these results, corona discharge in porcelain insulator was generated the weakness point of insulator union. And the corona discharge of polymer insulator happened in union of power source. Also, we could confirm easily weakness part of these insulators by ultraviolet image through the corona discharge. Besides, in the comparison with the exciting technique of ultrasonic detection, it confirmed that deterioration steps are corrected. These steps are possible to judge the deterioration of power facilities through reliable date. Hereafter, this study as the diagnostic technology suitable for the sites is used.

The Maintenance and Management Method of Deteriorated Facilities Using 4D map Based on UAV and 3D Point Cloud (3D Point Cloud 기반 4D map 생성을 통한 노후화 시설물 유지 관리 방안)

  • Kim, Yong-Gu;Kwon, Jong-Wook
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.3
    • /
    • pp.239-246
    • /
    • 2019
  • According to the survey on the status of aged buildings in Korea, A number of concrete buildings deterioration such as houses and apartment buildings has been increased rapidly. To solve this problem, the research related to the facility management, that is one of the importance factor, for monitoring buildings has been increased. The research is divided into Survey-based and Technique-based. However, the problem is that Survey-based research is required a lot of time, money and manpower for management. Also, safety cannot be guaranteed in the case of high-rise buildings. Technique-based research has limitations to applying to the current facility maintenance system, as detailed information of deteriorated facilities is difficult to grasp and errors in accuracy are feared. Therefore, this paper contribute to improve the environment of facility management by 4D maps using UAV, camera and Pix4D mapper program to make 3D model. In addition, it is expected to suggest that residents will be offered easy verification to their buildings deterioration.

Relationship between the Tidal Range in Sea Level and Damage of Domestic Port Facility (해수면 조위차와 항만시설물의 손상과의 관계 분석)

  • Binna Lee;Jong Suk Lee;Sung Jin Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.55-61
    • /
    • 2023
  • In this study, a basic research was conducted to establish a maintenance plan considering the environmental factors and deterioration characteristics of port facilities. The precise safety diagnosis reports for Incheon and Busan port facilities were referenced to examine the extent of deterioration and damage. The relationship with the degradation environmental assessment presented in the current guidelines was also analyzed. The analysis of the damage level of Incheon and Busan port facilities revealed that Incheon Port exhibited approximately three times higher damage rate compared to Busan Port. In the case of Incheon Port, reinforcement corrosion and external damage showed similar proportions, while in Busan Port, reinforcement corrosion had a higher proportion compared to external damage. On the other hand, when comparing with the degradation environmental assessment presented in the guidelines, it was found that there were some limitations in performing quantitative evaluation based on the guidelines for assessing port facilities. Therefore, an analysis based on tidal range was conducted by referring to existing literature. The analysis of tidal range in Incheon and Busan regions showed that Incheon had approximately five times higher difference compared to Busan. It is considered that this can be utilized as a differentiated item from existing degradation environmental assessment criteria.

A Study on Developing a Management System of Maintenance Historical Data for Effective Maintenance Performance of Building Managers (시설 관리자의 효율적인 유지관리 업무 수행을 위한 건축물 유지관리 이력정보관리 시스템 개발 연구)

  • Lee, Chun-Kyong;Park, Tae-Keun
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.312-315
    • /
    • 2007
  • This study is aimed at developing a web-based management system of maintenance historical data, for effective maintenance performance and smooth exchange of information and communication between public facilities and public educational facilities managers. The current management state of maintenance historical data and its business process were investigated and analyzed, through interviewing with the persons in charge of managing each facility, by recognizing problems of maintenance historical data management that is able to be applied as a basis to judge facility deterioration and performance. In addition, this study suggests a maintenance historical data system of which DB may be applied to the practical business, by reflecting requests of the persons in charge of managing facilities, setting up the scope of system usage by facility, business phase and level of facility managers, and establishing a maintenance business process system.

  • PDF

A Study on the Architectural Planning of Nurseries - With emphasis on planning of spatial organization - (보육시설의 건축계획에 관한 연구 - 공간구성계획을 중심으로 -)

  • Chung, Ji-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.5 no.1
    • /
    • pp.33-43
    • /
    • 1998
  • With increased social participation of married women and with the notion of importance of pre-school childhood on human development, the importance of nurseries is being emphasized. The transformation of the traditional family system into a nuclear family system and the deterioration of the traditional child education have also put nurseries as a primal social interest. But, at present, at the end of 1994, only 10% of the children have benefitted from such facilities, the supply not being able to meet demand. Also, the spatial organization and the management of such facilities has been unsatisfactory. In this perspective, this study aims to grasp the present condition of nurseries, to investigate and analyse case studies, to suggest standards and reform measures, and based on these, to produce basic information for the formation of an architectural spatial model. We've selected investigation of present conditions and case studies, interviews, and observation as investigative methods and through these we've assessed tangible spatial planning and spatial proportion by parts. 1. The most preferred grouping method is toddler/preschooler type, and the group size and staff-to-child ratios vary according to the children's age 2. The younger children's activity rooms are located in the lower level, and the activity room of the children on the similar development stages are located adjacent to one another 3. Most of the facilities do not have the public spaces(indoor playrooms, dinning rooms, napping rooms, bathrooms, sickrooms) For dinning and napping, activity rooms are being used, and for sickrooms, director's room or staff rooms 4. As for the correlations of the spaces(home bases, activity rooms and its outdoor spaces, day-care-centers and its community), closed plan type is 90% over, and modified open plan is 10% min.

  • PDF

Risk Assessment and Contact Angle Measure According to Surface Deterioration of PVC and Phenolic Resin (PVC와 페놀수지의 표면열화에 따른 접촉각 측정과 위험성 평가)

  • Shong, Kil-Mok;Han, Woon-Ki;Kim, Young-Seok;Jung, Jin-Su;Jung, Jong-Wook;Kim, Sun-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.458-462
    • /
    • 2007
  • It is necessary to study a conductive characteristics of electrical facilities covered with particulate for the analysis of electrical accidents in vulnerable area where are included market place, a sawmill and so on. Therefore, there are studied on risk assessment and contact angle measure(CAM) according to surface deterioration of PVC and phenolic resin Through the contact angle measure of samples, there are ascertain whether hydrophobicity or not. These data would used to be judged by the causes of electrical accidents.

  • PDF

A Study on the Environment Planning of Exhibition Space for Conservation of Collection in a Museum (박물관자료의 보존을 위한 전시공간 환경계획에 관한 연구)

  • Jung, Sung-Wook
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.2
    • /
    • pp.91-101
    • /
    • 2008
  • The purpose of this study is to suggest the design guidelines of exhibition space for conservation of collection in a museum. With the purpose of this study, examined the concept and a condition of conservation which is focused on deterioration in a exhibition space, investigated the actual condition of total 42 facilities and analyzed the specific instance which is excellent by factor of environment plan. Hereupon, the results of this study are as follows. First, exhibition space should be equipped with sufficient 'Filtering Space' before the outdoor and located central territory in a museum facility. Second, exhibition space should be partition off an area into the quality of collection, and then controlled by each of them. Third, in consideration of the annual air fluctuation of our country, the database which is adaptable for setting up the standard of temperature and RH must be prepared. Fourth, it is necessary to establish a 'Reference Exhibition Room' which is formed cellular type and a 'Garnering Exhibition Center'. Fifth, for the prevention of deterioration which is generated in exhibition space, the showcase must be high air-tight. Sixth, it is necessary to reduce a inside space of high air-tight showcase. Seventh, art-sorb is suitable for control the organic matter of collection and a except of fiber optics is not suitable for lighting of showcase. Eighth, wall-type showcase should be have air-chamber which is formed like museum storage and run over 8 hours a day.