• 제목/요약/키워드: Deterioration facilities

검색결과 255건 처리시간 0.023초

교육시설(敎育施設)의 리모델링을 위한 구성재료(構成材料)의 노후화(老朽化) 판정기준(判定基準) 작성(作成)(III) - 주요(主要) 마감재료(材料)의 노후도(老朽度) 종합판정방법(綜合判定方法) 제시(提示) - (Evaluation Method of Deterioration Grade for Remodeling Old Educational Facilities(III) - Synthetic Judgment Method of Deterioration Grade of Finished Materials -)

  • 서치호;최민권;최수경;오세출;권용균
    • 교육시설
    • /
    • 제11권1호
    • /
    • pp.15-23
    • /
    • 2004
  • Deterioration of the educational facilities built before 1985 is a serious situation. The purpose of this study is to present the efficient remodeling method of old educational facilities. This paper, part III, presents the systemic and synthetic judgment method of deterioration grade of finished materials. Evaluation of the deterioration is carried out in every eight classrooms or building elements divided by the use. And classrooms are divided by several parts for example floor, wall and ceiling etc.. The whole deterioration of the building judges the result of every part collectively.

교육시설(敎育施設)의 리모델링을 위한 구성재료(構成材料)의 노후화(老朽化) 판정기준(判定基準) 작성(作成)(II) - 주요(主要) 구성부재(構造部材)의 노후도(老朽度) 종합판정방법(綜合判定方法) 제시(提示) - (Evaluation Method of Deterioration Grade for Remodeling Old Educational Facilities(II) - Synthetic Judgment Method of Deterioration Grade of Structural Components -)

  • 서치호;최민권;최수경;오세출
    • 교육시설
    • /
    • 제10권5호
    • /
    • pp.15-22
    • /
    • 2003
  • Deterioration of the educational facilities built before 1985 is a serious situation. The purpose of this study is to present the efficient remodeling method of old educational facilities. This paper, part II, presents the systemic and synthetic judgment method of deterioration grade of structural components. Deterioration grade of the whole structural components are judged by synthetic evaluation score which is the total of the score of ten evaluation items. And we added the importance coefficient of the viewpoint of four performance to each evaluation item.

예산배분을 위한 철도선로구간의 노후도 평가 (Deterioration Evaluation of Railway Line Segments for Budget Distribution)

  • 김성호;최찬용;나희승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1802-1809
    • /
    • 2011
  • A distribution method of limited budget for rail line facility improvement is to use investment priorities of rail line segments based on their deterioration. In this paper we present an evaluation method of rail line segment deterioration which can be used to distribute limited budget. Rail line facilities include rail track, crossing, road bed, bridge, tunnel. These facilities deterioration and line shape can affect line segment deterioration. Deterioration evaluation method we present is a weighted sum of each component deterioration scores. The component weight can be obtained from experts using analytic hierarchy process.

  • PDF

누설전류 파고분석에 의한 전력설비의 열화진단 기술 (Deterioration Diagnostic Techniques for Power Facilities by Analyzing Pulse-Height of leakage current)

  • 한주섭;김명진;손원진;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 추계종합학술대회
    • /
    • pp.367-370
    • /
    • 2001
  • 본 논문에서는 누설전류 파고분석을 이용한 전력선비의 새로운 열화 진단법을 제안하였다. 현재까지 여러가지 열화 진단법이 제안되었으며, 평가요소로 누설전류의 크기만을 이용하는 것이 일반적이었다. 본 연구에서는 피뢰기, 케이블 등의 전력설비들이 열화가 진전됨에 따라 누설전류의 파고분포도 크게 달라짐을 알 수 있었다. 따라서 전력설비의 열화진단에 누설전류의 파고분포를 이용하면 기존의 누설전류의 크기만을 이용하는 방법보다 더 정확한 평가가 가능하다. 피뢰기, 케이블을 이용한 여러 가지 적용실험으로부터 제안한 열화 진단법은 충분한 성능이 있음을 확인하였다.

  • PDF

교육시설의 옥상방수 열화도 진행 모델에 관한 연구 (A Study on the Establishment of the Deterioration Process Model of Roof Waterproofing in the Education facilities)

  • 이강희;채창우;류수훈
    • 교육시설 논문지
    • /
    • 제24권6호
    • /
    • pp.11-18
    • /
    • 2017
  • Education facilities have much affect to make a good condition for the learning environment. Therefore, various approaches have been conducted to improve the physical, social and educational achievement. Especially, the physical aspect is very important to get rid of the building defect and improve the student their learning environment. For these, it needs to explain the performance and function of components and materials, which is linked with the deterioration degree. The deterioration degree is a imperative factor to make a decision whether the component would be repaired or not and to provide the repair scope of its component. In this paper, it aimed at making the deterioration degree model of roof proof under the hypothesis of which deterioration degree would be equal the repair cost at this time. Results of the study are shown that first, the $3^{rd}$ function is most proper to explain the deterioration degree model among 11 functions in view of resulted statistics. Second, the inflection of deterioration is shown at 15yr of the elementary school and 13yr of the middle and high school. This study has a limit of disclassification of the component or materials and it is, therefore, favorable to include the classification of waterproof material and work. These results would make a change from the breakdown maintenance to preventive maintenance and give a decent the learning environment for student.

학교건물(學校建物) 건축설비(建築設備)시스템의 노후도(老朽度) 평가(評價) 기준(基準)마련을 위한 기초연구(基礎硏究) (Evaluation of Deterioration Grade for Remodeling Architectural Facilities in Old Schools)

  • 조민관;조창근;박종수
    • 교육시설
    • /
    • 제13권4호
    • /
    • pp.15-23
    • /
    • 2006
  • The purpose of this study is to establish the objective deterioration grades and evaluation criteria of building equipment system of educational facilities available for reasonable maintenance and remodeling of them. For the purpose of it, the actual conditions of building equipment systems of the 148 buildings of 84 middle and high schools in Seoul 20 years after construction are investigated and surveyed through one-on-one interviews and questionnaires. And, deterioration grades of them are estimated by the evaluation criteria which is proposed in this study. As a result of this study, the 10 deterioration grades and the 4 evaluation criteria of the 6 performances of building equipment system, which are heating and cooling, water supply and drainage, hot water supply and electrical power performance, are suggested. And, as a result of the survey, it showed that 24% of the investigated school buildings were estimated C grade which needs partial remodelling, and 51% of the school buildings were estimated D grade which needs extensive remodelling. And, 25% of the school buildings were estimated E grade which needs overall remodelling or alteration of building equipment system.

화학적 침식을 받은 하수처리시설 콘크리트 구조물의 성능저하에 대한 미세구조적 관찰 (Microstructural Observations on the deterioration of Concrete Structure for Wastewater Treatment Facilities Subjected to Chemical Attack)

  • 김성수;이승태;박광필;봉원용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.547-550
    • /
    • 2005
  • Recently, there has been a intensive social interest for concrete structures with respect to durability by carbonation, chemical attack etc. Specially, the deterioration of concrete due to chemical attack in environments such as Wastewater Treatment Facilities is important factors degrading the durability of concrete structure. The purpose of this paper is to evaluate on deterioration of Wastewater Treatment Facilities concrete to chemical attack through instrumental analysis such as XRD, SEM and EDS. According to the results of this study. Wastewater Treatment Facilities concrete to chemical attack due to $So_{4}^{2-},\;Mg^{2+}$ ions founded out to appear deterioration materials peak : ettringite/thaumasite. gypsum and brucite peak.

  • PDF

농촌마을 공동시설 리모델링 및 관리 프로세스 구축에 관한 연구 (The Study on the Establishment of Rural Community Facility Remodeling and Management Process)

  • 김상범;신재선;김은자
    • 한국농촌건축학회논문집
    • /
    • 제17권3호
    • /
    • pp.63-70
    • /
    • 2015
  • Recently, the rural village development projects are proceeding as enhancement of the rural landscape as the interest toward rural tourism and rural immigrant has increased. However, the projects are solely to support construction of community space and there has been a lack of community facility remodeling in term of both deterioration facilities and abandoned facilities. Thus in this study proposes rural community facility remodeling process to utilize remodeling of rural deterioration facilities and abandoned facilities. For setting rural community remodeling process, this study analysed preceding research data and suggested rural community remodeling process stage ; planning, spacial resolution, remodeling factor analysis, implementation, maintenance control, based on research data. For systematic performed this process, this study regulated role of local resident, expert and local government on remodeling process stage.

AHP를 활용한 철도선로구간 노후도 평가 (Deterioration Evaluation of Railway Line Segments Using Analytic Hierarchy Process)

  • 김성호
    • 한국철도학회논문집
    • /
    • 제14권6호
    • /
    • pp.569-574
    • /
    • 2011
  • 정된 예산으로 철도선로시설을 개선하고자 할 때 사용할 수 있는 효과적인 예산배분 방법 중 하나는 가장 노후도가 심각한 선로구간부터 우선적으로 예산을 투입하는 것이다. 본 논문에서는 예산배분에 사용할 수 있는 선로구간 노후도 평가방법을 제시한다. 선로구간의 노후도는 궤도, 분기기, 노반, 교량, 터널 등 요소 시설물의 노후도로 결정되며 궤도의 선형 또한 선로구간 노후도에 영향을 준다. 본 논문에서 제시하는 노후도 평가 방법은 각 요소의 노후도 점수에 AHP로 구한 요소 가중치를 반영하여 선로구간 노후도 점수를 구하는 것이다.

학교시설물의 노후화 현상 및 지진.화재.풍수해의 피해에 대한 사례 조사연구 (A investigation study on the site analysis damaged by disaster and deterioration reason of school facilities)

  • 윤유혁;신이철;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.21-26
    • /
    • 2008
  • We investigate the various factors such as earthquake, fire, flood and deterioration factors such as carbonation, salt attack, freezing thawing, alkali-aggregate reaction effects on the school facilities. As the consequence of this study we can see that there are very relative relation between deterioration factors and disaster factors. It is the aim of this study to investigate the site analysis damaged by disaster and deterioration factors of school facilities.

  • PDF