Evaluation Method of Deterioration Grade for Remodeling Old Educational Facilities(III) - Synthetic Judgment Method of Deterioration Grade of Finished Materials - (교육시설(敎育施設)의 리모델링을 위한 구성재료(構成材料)의 노후화(老朽化) 판정기준(判定基準) 작성(作成)(III) - 주요(主要) 마감재료(材料)의 노후도(老朽度) 종합판정방법(綜合判定方法) 제시(提示) -)

  • Seo, Chee-Ho;Choi, Min-Kwon;Choi, Soo-Kyung;Oh, Se-Chul;Kwon, Yong-Kyun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.1
    • /
    • pp.15-23
    • /
    • 2004
  • Deterioration of the educational facilities built before 1985 is a serious situation. The purpose of this study is to present the efficient remodeling method of old educational facilities. This paper, part III, presents the systemic and synthetic judgment method of deterioration grade of finished materials. Evaluation of the deterioration is carried out in every eight classrooms or building elements divided by the use. And classrooms are divided by several parts for example floor, wall and ceiling etc.. The whole deterioration of the building judges the result of every part collectively.

Evaluation Method of Deterioration Grade for Remodeling Old Educational Facilities(II) - Synthetic Judgment Method of Deterioration Grade of Structural Components - (교육시설(敎育施設)의 리모델링을 위한 구성재료(構成材料)의 노후화(老朽化) 판정기준(判定基準) 작성(作成)(II) - 주요(主要) 구성부재(構造部材)의 노후도(老朽度) 종합판정방법(綜合判定方法) 제시(提示) -)

  • Seo, Chee-Ho;Choi, Min-Kwon;Choi, Soo-Kyung;Oh, Se-Chul
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.10 no.5
    • /
    • pp.15-22
    • /
    • 2003
  • Deterioration of the educational facilities built before 1985 is a serious situation. The purpose of this study is to present the efficient remodeling method of old educational facilities. This paper, part II, presents the systemic and synthetic judgment method of deterioration grade of structural components. Deterioration grade of the whole structural components are judged by synthetic evaluation score which is the total of the score of ten evaluation items. And we added the importance coefficient of the viewpoint of four performance to each evaluation item.

Deterioration Evaluation of Railway Line Segments for Budget Distribution (예산배분을 위한 철도선로구간의 노후도 평가)

  • Kim, Seong-Ho;Choi, Chan-Yong;Na, Hee-Seung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1802-1809
    • /
    • 2011
  • A distribution method of limited budget for rail line facility improvement is to use investment priorities of rail line segments based on their deterioration. In this paper we present an evaluation method of rail line segment deterioration which can be used to distribute limited budget. Rail line facilities include rail track, crossing, road bed, bridge, tunnel. These facilities deterioration and line shape can affect line segment deterioration. Deterioration evaluation method we present is a weighted sum of each component deterioration scores. The component weight can be obtained from experts using analytic hierarchy process.

  • PDF

Deterioration Diagnostic Techniques for Power Facilities by Analyzing Pulse-Height of leakage current (누설전류 파고분석에 의한 전력설비의 열화진단 기술)

  • 한주섭;김명진;손원진;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.367-370
    • /
    • 2001
  • This paper proposes a new deterioration diagnostic technique for power facilities by analyzing the pulse-height analysis of leakage current. Until now, various deterioration diagnostic techniques to prevent power system failures by deterioration of power facilities are suggested, and most of which measures leakage current amplitude only as a estimation parameter. In this experiment, it is known that the pulse heights of the leakage current are increased according to deterioration progress as well as there comes remarkable changes in pulse height distribution thereto. Therefore, the use of pulse height distribution in deterioration diagnostic technique makes more accurate diagnosis than the conventional method by using only leakage current value. From the application test, it is confirmed that the proposed technique has sufficient performance to diagnose deterioration of power facilities.

  • PDF

A Study on the Establishment of the Deterioration Process Model of Roof Waterproofing in the Education facilities (교육시설의 옥상방수 열화도 진행 모델에 관한 연구)

  • Lee, Kang-Hee;Chae, Chang-U;Ryu, Soo-Hoon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.6
    • /
    • pp.11-18
    • /
    • 2017
  • Education facilities have much affect to make a good condition for the learning environment. Therefore, various approaches have been conducted to improve the physical, social and educational achievement. Especially, the physical aspect is very important to get rid of the building defect and improve the student their learning environment. For these, it needs to explain the performance and function of components and materials, which is linked with the deterioration degree. The deterioration degree is a imperative factor to make a decision whether the component would be repaired or not and to provide the repair scope of its component. In this paper, it aimed at making the deterioration degree model of roof proof under the hypothesis of which deterioration degree would be equal the repair cost at this time. Results of the study are shown that first, the $3^{rd}$ function is most proper to explain the deterioration degree model among 11 functions in view of resulted statistics. Second, the inflection of deterioration is shown at 15yr of the elementary school and 13yr of the middle and high school. This study has a limit of disclassification of the component or materials and it is, therefore, favorable to include the classification of waterproof material and work. These results would make a change from the breakdown maintenance to preventive maintenance and give a decent the learning environment for student.

Evaluation of Deterioration Grade for Remodeling Architectural Facilities in Old Schools (학교건물(學校建物) 건축설비(建築設備)시스템의 노후도(老朽度) 평가(評價) 기준(基準)마련을 위한 기초연구(基礎硏究))

  • Cho, Min-Kwan;Cho, Chang-Geun;Park, Jong-Soo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.13 no.4
    • /
    • pp.15-23
    • /
    • 2006
  • The purpose of this study is to establish the objective deterioration grades and evaluation criteria of building equipment system of educational facilities available for reasonable maintenance and remodeling of them. For the purpose of it, the actual conditions of building equipment systems of the 148 buildings of 84 middle and high schools in Seoul 20 years after construction are investigated and surveyed through one-on-one interviews and questionnaires. And, deterioration grades of them are estimated by the evaluation criteria which is proposed in this study. As a result of this study, the 10 deterioration grades and the 4 evaluation criteria of the 6 performances of building equipment system, which are heating and cooling, water supply and drainage, hot water supply and electrical power performance, are suggested. And, as a result of the survey, it showed that 24% of the investigated school buildings were estimated C grade which needs partial remodelling, and 51% of the school buildings were estimated D grade which needs extensive remodelling. And, 25% of the school buildings were estimated E grade which needs overall remodelling or alteration of building equipment system.

Microstructural Observations on the deterioration of Concrete Structure for Wastewater Treatment Facilities Subjected to Chemical Attack (화학적 침식을 받은 하수처리시설 콘크리트 구조물의 성능저하에 대한 미세구조적 관찰)

  • Kim Seoung Soo;Lee Seung Tae;Park Kwang Pil;Bong Won Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.547-550
    • /
    • 2005
  • Recently, there has been a intensive social interest for concrete structures with respect to durability by carbonation, chemical attack etc. Specially, the deterioration of concrete due to chemical attack in environments such as Wastewater Treatment Facilities is important factors degrading the durability of concrete structure. The purpose of this paper is to evaluate on deterioration of Wastewater Treatment Facilities concrete to chemical attack through instrumental analysis such as XRD, SEM and EDS. According to the results of this study. Wastewater Treatment Facilities concrete to chemical attack due to $So_{4}^{2-},\;Mg^{2+}$ ions founded out to appear deterioration materials peak : ettringite/thaumasite. gypsum and brucite peak.

  • PDF

The Study on the Establishment of Rural Community Facility Remodeling and Management Process (농촌마을 공동시설 리모델링 및 관리 프로세스 구축에 관한 연구)

  • Kim, Sang-Bum;Shin, Jae-Sun;Kim, Eun-Ja
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.3
    • /
    • pp.63-70
    • /
    • 2015
  • Recently, the rural village development projects are proceeding as enhancement of the rural landscape as the interest toward rural tourism and rural immigrant has increased. However, the projects are solely to support construction of community space and there has been a lack of community facility remodeling in term of both deterioration facilities and abandoned facilities. Thus in this study proposes rural community facility remodeling process to utilize remodeling of rural deterioration facilities and abandoned facilities. For setting rural community remodeling process, this study analysed preceding research data and suggested rural community remodeling process stage ; planning, spacial resolution, remodeling factor analysis, implementation, maintenance control, based on research data. For systematic performed this process, this study regulated role of local resident, expert and local government on remodeling process stage.

Deterioration Evaluation of Railway Line Segments Using Analytic Hierarchy Process (AHP를 활용한 철도선로구간 노후도 평가)

  • Kim, Seong-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.6
    • /
    • pp.569-574
    • /
    • 2011
  • An effective approach to distributing budget to railway line facility improvement is to use investment priorities of railway line segments based on their deterioration. In this paper we present an evaluation method of railway line segment deterioration which can be used to distribute limited budget. Railway line facilities include rail track, railroad switch, subgrade, bridge, tunnel. These facilities and line shape can affect line segment deterioration. Deterioration evaluation method we present is a weighted sum of each component deterioration scores. The component weight can be obtained from experts using analytic hierarchy process.

A investigation study on the site analysis damaged by disaster and deterioration reason of school facilities (학교시설물의 노후화 현상 및 지진.화재.풍수해의 피해에 대한 사례 조사연구)

  • Yun, Yoo-Hyuk;Shin, Yi-Chul;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.21-26
    • /
    • 2008
  • We investigate the various factors such as earthquake, fire, flood and deterioration factors such as carbonation, salt attack, freezing thawing, alkali-aggregate reaction effects on the school facilities. As the consequence of this study we can see that there are very relative relation between deterioration factors and disaster factors. It is the aim of this study to investigate the site analysis damaged by disaster and deterioration factors of school facilities.

  • PDF